MAURY USCG vessel records
← All vessels

HAMPSHIRE

HAMPSHIRE is a 1980 towing vessel. The Coast Guard has recorded 47 inspections since 1992, most recently in May 2026, along with 20 deficiencies, 1 operational control and 4 casualty investigations between 2006 and 2009.

Records from 1992 to 2026. Most recent: inspection, 15 May 2026.

Built
1980
Last inspected
15 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 15 May 2026
…with no type recorded26
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ3189
188099
Flag
UNITED STATES
Maury page id
psix-188099

Documentation record

Registered dimensions (L × B × D)46.0 ft × 20.0 ft × 6.7 ft
Registered tonnagegross 78 / net 53
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBALEHI MARINE INC · LACOMBE, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 22

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AXL 216 Tank Barge · MISLE 41248 · 26 January 2009 · activity 3401652AXL 221 Tank Barge · MISLE 48762 · 26 January 2009 · activity 3401652PTC 460 Freight Barge · MISLE 448290 · 21 August 2007 · activity 3036217DIMMIT Towing Vessel · MISLE 450674 · 21 August 2007 · activity 3036217MMI 2807 Tank Barge · MISLE 863625 · 21 August 2007 · activity 3036217SCC 103 Tank Barge · MISLE 46684 · 23 February 2006 · activity 2598616SCC 106 Tank Barge · MISLE 48306 · 23 February 2006 · activity 2598616LACB 116 Tank Barge · MISLE 622547 · 23 February 2006 · activity 2598616DECATUR Towing Vessel · MISLE 723052 · 23 February 2006 · activity 2598616RHA 2201 Tank Barge · MISLE 25404 · 11 February 2006 · activity 2597191SCC-100 Tank Barge · MISLE 45949 · 30 November 2001 · activity 726377MISS FAYE Towing Vessel · MISLE 81626 · 30 November 2001 · activity 726377CCI-75 Tank Barge · MISLE 43505 · 25 April 1998 · activity 13872SCC 106 Tank Barge · MISLE 48306 · 25 April 1998 · activity 13872KIRBY 28007B Tank Barge · MISLE 49344 · 25 April 1998 · activity 13872SCC 80 Tank Barge · MISLE 44289 · 18 November 1997 · activity 46222CAPT KENNY Towing Vessel · MISLE 72445 · 18 November 1997 · activity 46222WILLIAM J Freight Barge · MISLE 426183 · 18 November 1997 · activity 46222RHA 1702 Tank Barge · MISLE 46356 · 2 September 1997 · activity 83041N.M.S. NO. 1444 Freight Barge · MISLE 52067 · 2 September 1997 · activity 83041BAYOU RUNNER Towing Vessel · MISLE 79658 · 28 November 1995 · activity 117180HOLLYWOOD 2511 Tank Barge · MISLE 41057 · 6 July 1992 · activity 182660EVA Towing Vessel · MISLE 188421 · 6 July 1992 · activity 182660

Inspection history · 47

15 May 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8350689
14 May 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8135825
11 April 2024 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7892540
13 July 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7741572
6 June 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7511044
13 October 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7332117
13 August 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7285837
8 April 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7171018
8 September 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071811
20 May 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6956653
22 April 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942326
27 February 2019 Administrative Inspection · COI Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6640317
24 June 2014 Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4898554
19 May 2014 Deficiency Check · Risk-based Targeted Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4863565
15 May 2014 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4859642
2 August 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4399114
9 March 2010 Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3692677
14 February 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3419165
26 January 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3401652
9 December 2008 Administration
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3377573
21 August 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3036217
25 August 2006 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2762032
23 February 2006 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2591109
23 February 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2598616
11 February 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2597191
24 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2406178
29 July 2004 MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2150017
12 January 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982309
7 January 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982377
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1964269
23 June 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1824550
11 April 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1604093
30 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 726377
28 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771446
22 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 205566
29 May 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771426
23 May 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 205569
8 February 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274610
30 August 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 96668
21 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418357
25 April 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 13872
12 January 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 424485
18 November 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 46222
2 September 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 83041
21 August 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 514773
28 November 1995 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 117180
6 July 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 182660

Deficiency record · 20

02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 August 2025 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Inspection found watertight doors on messdeck starboard side and in engine room port side would not seal properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2025
Resolution: Received objective evidence of seals and doors adjusted properly. No light leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2025 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Inspection found that portable electric bilge pump would not meet the requirements needed in an emergency dewatering situation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2025
Resolution: Received objective evidence that a gas powered portable pump was placed onboard the vessel and was working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 August 2025 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided:High bilge levels. Inspection found high bilge level sensor location in the engine room but not properly mounted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2025
Resolution: Received objective evidence of bilge sensor being installed properly.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 August 2025 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Inspection found machinery space stbd exhaust fan self closing louvers would not close properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2025
Resolution: Received objective evidence that the louvers were able to close properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 August 2025 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided; Alarms must:Not interfere with night vision at the operating station. Inspection found emergency lighting, high bilge visual alarm, and low hydraulic steering oil visual alarm were installed on bridge that would interfere with night vision.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 28 August 2025
Resolution: Darkened lenses.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 August 2025 Resolved
A fixed fire pump must be capable of: being energized remotely from a safe place outside the engine room and at the pump. Inspection found no local controls at the pump in the machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2025
Resolved 28 August 2025
Resolution: Installed local fire pump controls.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 August 2025 Resolved
On vessels of less than 20 meters in length, the sidelights, shall be fitted with matte black inboard screens. Inspection found screens not painted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 10 September 2025
Resolution: Received objective evidence of repairs. Nav light screens were painted matte black.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 August 2025 Resolved
The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure Main engine RPM Main engine cooling water temperature Generator engine RPM Inspection found the above gauges missing for both MDE's and generators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 22 September 2025
Resolution: Received video evidence of gauges being installed at machinery.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 11 April 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Low hydraulic steering fluid levels. Install and test low hydraulic steering fluid alarm.46 CFR 143.230.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2024
Resolved 25 July 2024
Resolution: Received objective evidence of steering hydraulic fluid low lwvel alarm installed and tested.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 June 2022 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Fuel shut off did not close valve off all the way. 46 CFR 143.260
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2022
Resolution: Rcvd video
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 13 August 2021 Resolved
Each towing vessel must have a means to monitor and control the amount of thrust, rudder angle, and (if applicable) direction of thrust, at each operating station. Each towing vessel equipped with rudder(s) must have a means to monitor and control the position of the rudder(s) at each operating station. Vessel does not have means to monitor and control position of the rudder(s) at operating station. 46 CFR 143.225(a)(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2021
Resolved 13 October 2021
Resolution: Cleared pending regulatory guidance.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 April 2021 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing in case of fire. Each doorway, ventilator and annular space around funnels and oter openings into such spaces. No means to close/cover openings to machinery space. 46CFR144.605
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 23 April 2021
Resolution: Fabricated cover
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 April 2021 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Bilge alarm in machinery space but not at the operating station. 46CFR143.230(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 23 April 2021
Resolution: Installed audible/visual alarm at op station
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 May 2020 Resolved
Smoke detectors were found with expired batteries. Replace all expired batteries.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2020
Resolved 2 June 2020
Resolution: Batteries were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 May 2020 Resolved
02 distress signals were found expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2020
Resolved 2 June 2020
Resolution: expired flares were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2020 Resolved
Lifejacket lights were found expired on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2020
Resolved 2 June 2020
Resolution: Lifejacket lights were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2020 Resolved
Engineroom battery chargers were found with out proper covers on top to prevent debris and water from entering. Provide covers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2020
Resolved 2 June 2020
Resolution: Steel covers were installed on top of battery chargers.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 May 2014 Resolved
Vessel does not have a valid COD. Confirmed the same with NVDC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2014
Resolution: Vessel obtained a COD. MSU Paducah verified in MISLE.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 21 July 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 July 1998
Resolved 9 November 2006
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 21 July 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 August 1998
Resolved 9 November 2006

Casualty record · 4

11 February 2006Routine · role: Involved in a Marine Casualty · activity 2597191
23 February 2006Routine · role: Involved in a Marine Casualty · activity 2598616
21 August 2007Routine · role: Involved in a Marine Casualty · activity 3036217
26 January 2009Routine · role: Involved in a Marine Casualty · activity 3401652
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.