Records from 1985 to 1996. Most recent: inspection, 17 September 1996.
Inspection history · 64
17 September 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 153617
8 September 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 395073
18 June 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 392197
29 January 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 387369
29 January 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1079213
21 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 384168
13 July 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380593
6 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 500561
14 June 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 453495
10 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375202
8 February 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 510787
2 December 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 437285
1 December 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 373063
18 August 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1177568
1 August 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1171786
1 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1174789
21 June 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 367914
27 May 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 14885
24 May 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 198663
24 May 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 751836
19 April 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366196
10 November 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 470563
11 May 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1137240
4 April 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 357444
22 February 1993
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 834602
15 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355685
15 January 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1140823
27 November 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 512739
23 November 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 827598
13 October 1992
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1268719
24 June 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1267006
31 May 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 175645
31 May 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 961459
13 May 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1268810
21 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 518009
25 November 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 448472
4 November 1991
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 935155
11 September 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 934197
7 May 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 907070
22 March 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1244329
19 July 1990
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 924461
25 May 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 438001
4 December 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 523239
2 August 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 331860
14 June 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 472211
14 June 1989
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 896132
21 February 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 530448
16 December 1988
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1340141
10 June 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032360
4 December 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 454818
2 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 523541
2 October 1987
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1011241
10 July 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1322437
5 June 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1027851
5 June 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1335389
22 April 1987
Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010122
21 November 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 478260
29 September 1986
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1005115
10 September 1986
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1000576
8 September 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1332935
20 June 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 309649
6 February 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 472698
18 September 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 304273
5 June 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302317
Fire Fighting
Issued 29 January 1996
Resolved
PROVIDE CLASS REPORT AS TO REPAIRS AND PROPER OPERATION OF EMERGENCY FIRE PUMP AS REQUIRED BY SOLAS 60 II/56 TO SATISFACTION OF LOCAL U.S. COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 29 January 1996
Resolved 31 January 1996
Documentation
Issued 29 January 1996
Resolved
PROVIDE CLASS REPORT AS TO AMENDING OF CARGO TRANSFER PROCEDURES TO INCLUDEVCS PROCEDURES AS REQUIRED BY 46 CFR 39 TO SATISFACTION OF LOCAL U.S. COASTGUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Lifesaving
Issued 29 January 1996
Resolved
PROVIDE SPAN GAS FOR CALIBRATION OF EXPLOSIVE METER AS REQUIRED BY BCH CODE3.13 TO SATISFACTION OF LOCAL U.S. COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 2 July 1996
Resolved 2 July 1996
Deck/Cargo
Issued 29 January 1996
Resolved
PROVIDE TEST CERTIFICATE FOR P/V VALVES AS REQUIRED BY 33 CFR 156.170 TO SATISFACTION OF LOCAL U.S. COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Deck/Cargo
Issued 29 January 1996
Resolved
PROVIDE TEST CERTIFICATE FOR VACUMN AND CARGO HOSES AS REQUIRED BY 33 CFR 156.170 TO SATISFACTION OF LOCAL U.S. COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Deck/Cargo
Issued 29 January 1996
Resolved
PROVIDE CLASS REPORT ON REPAIRS AND SATISFACTORY OPERATION OF ALL HIGH LEVEL AND OVERFILL ALARMS AS REQUIRED BY 46 CFR 153.404/409 TO SATISFACTIONOF LOCAL U.S. COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Deck/Cargo
Issued 29 January 1996
Resolved
PROVIDE CLASS REPORT OF TESTING AND PROPER OPERATION OF HIGH/LOW VAPOR PRESSURE SENSING DEVICE AND ALARM AS REQUIRED BY 46 CFR 39.20-13 TO SATISFACTION OF LOCAL U.S. COAST GUARD OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Deck/Cargo
Issued 21 October 1995
Resolved
PROVE PROPER OPERATION OF HIGH LEVEL ALARMS IN CARGO TANKS 2C AND 3C PRIOR_x001C_TO CARRIAGE OF CARGO.
Condition: Unknown
Due 25 October 1995
Resolved 26 October 1995
Deck/Cargo
Issued 21 October 1995
Resolved
PROVE PROPER OPERATIO OF VESSEL'S HIGH PRESSURE ALARMS PRIOR TO USING VCS_x001C_ IN U.S. WATERS.
Condition: Unknown
Due 25 October 1995
Resolved 26 October 1995
Deck/Cargo
Issued 13 July 1995
Resolved
PRIOR TO USE OF VAPOR COLLECTION SYSTEM IN THE U.S., MAKE PERMANENT REPAIRSTO VCS LOW PRESSURE ALARM.
Condition: Unknown
Due 13 September 1995
Resolved 15 November 1995
Deck/Cargo
Issued 13 July 1995
Resolved
PROVIDE INDICATOR AT VAPOR CONNECTION VALVE TO INDICATE IF THE VALVE IS OPEN OR CLOSED AS REQUIRED BY 46 CFR 39.20-1(C).
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Deck/Cargo
Issued 13 July 1995
Resolved
PRIOR TO LOADING CARGOES REQUIRING HIGH LEVEL ALARMS IN THE U.S., HAVE HIGHLEVEL AND OVERFILL ALARMS TESTED IN WITNESS OF ATTENDING USCG INSPECTOR. NOTE: VESSEL IS PROCEEDING TO D/D TO HAVE WORK DONE IN CARGO TANKS. NO ALARMS WERE TESTED DURING EXAM DUE TO FACILITY RESTRICTION DURING PHENOL OP
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Documentation
Issued 13 July 1995
Resolved
HAVE DET NORSKE VERITAS CLASS SOCIETY MAKE CORRECTIONS IN THE VAPOR CONROL MANUAL REGARDING THE P/V PRESSURE AND VACUUM SET POINTS. INFORMATION IN MANUAL SHOULD REFLECT INSTALLED EQUIPMENT.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Deck/Cargo
Issued 13 July 1995
Resolved
PROVIDE 1x1/2" STUD AT EACH VAPOR COLLECTION CONNECTION AS REQUIRED BY 46 CFR 39.20-1(E).
Condition: Unknown
Due 29 August 1995
Resolved 29 August 1995
Deck/Cargo
Issued 13 July 1995
Resolved
PROVE OPERATION OF ESD.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Construction/Loadline
Issued 13 July 1995
Resolved
RE-PAINT VESSEL'S NAME ON BOW
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Lifesaving
Issued 13 July 1995
Resolved
REPLACE L/B RATIONS
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Lifesaving
Issued 13 July 1995
Resolved
LASH BARRELS ON DECK.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Lifesaving
Issued 1 August 1994
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS REPORT FOR THE REPAIRS TO THE EMERGENCY FLOOD LIGHTS ON THE BRIDGE WINGS FOR LIFEBOAT OPERATIONS.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Electrical
Issued 1 August 1994
Resolved
REPAIR BROKEN LIGHT GLOBE IN #2 FIRE LOCKER PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Deck/Cargo
Issued 1 August 1994
Resolved
PROPERLY MARK CARGO PUMP SHUTDOWN AT MANIFOLD TO READ "EMERGENCY SHUTDOWN STATION" PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Deck/Cargo
Issued 1 August 1994
Resolved
PROVIDE PROOF THAT MASTER AND MATES HAVE COMPLETED A VAPOR COLLECTION SYSTEM TRAINING PROGRAM THAT MEETS 46 CFR 39.10-11, PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Navigation
Issued 1 August 1994
Resolved
CALIBRATE STANDARD MAGNETIC COMPASS IN STEERING GEAR ROOM OR PROVIDE DEVIATION TABLE IN STEERING GEAR ROOM AND BRIDGE TO SHOW PROPER CORRECTION,PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Lifesaving
Issued 1 August 1994
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS REPORT TO THE SUITABILITY OF LIFEJACKETS STOWED ON THE PORT AND STBDSIDE BOAT DECK LOCKERS.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Fire Fighting
Issued 1 August 1994
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS REPORT FOR PROPER LIFELINES STOWED IN FIRE LOCKERS.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Deck/Cargo
Issued 1 August 1994
Resolved
PROVIDE UP TO DATE "OIL TRANSFER PROCEDURES" AS REQUIRED BY 33 CFR 155.750 PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Navigation
Issued 1 August 1994
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE CLASS REPORT FOR OPERATION OF LOW LEVEL HYDRAULIC FLUID ALARMS, BOTH AUDIBLE AND VISUAL ON THE BRIDGE AND MACHINERYSPACE.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Deck/Cargo
Issued 1 August 1994
Resolved
PROVIDE WARNING SIGN AT GANGWAY AS REQUIRED.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Navigation
Issued 1 August 1994
Resolved
PROVIDE LOCK NUT FOR STEERING GEAR LINKAGE.
Condition: Unknown
Due 23 August 1994
Resolved 23 August 1994
Construction/Loadline
Issued 24 June 1992
Resolved
Provide [name withheld] with a copy of the gauging report and repair work performed upon completion of the next scheduled drydock.
Condition: Unknown
Due 24 June 1992
Resolved 24 June 1992
Deck/Cargo
Issued 13 May 1992
Resolved
CONDUCT HYDROSTATIC TEST OF THE CARGO PIPING TO 1.5 TIMES THE MAWP AND STENCIL TEST PRESSURE AND DATE OF TEST ON CARGO PIPING PRIOR TO CARRRYING CARGO IN U.S. WATERS.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992
Resolved
MAKE WING BALLAST TANK AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Accommodation/Occupational Safety
Issued 7 May 1991
Resolved
OBTAIN APPROVAL OR PROVIDE DOCUMENTATION OF CERTIFICATION FOR MARINE SANITATION DEVICE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Unknown
Issued 14 June 1989
Resolved
REPAIRS TO OILY WATER SEPARATOR WHICH WAS CORRECTED PRIOR TO VESSELS DEPARTURE FROM HOUSTON, TEXAS.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 5 June 1987
Resolved
RENEW BRANCH LINE FIRE MAIN PIPING IN FOC'S'LE IN-WAY-OF SOFT PATCH.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Deck/Cargo
Issued 5 June 1987
Resolved
REPAIR AND PROVE OPERATION OF PORTABLE OXYGEN METER.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Navigation
Issued 5 June 1987
Resolved
INSTALL CONTINUOUS RECORDING DEVICE FOR ECHO DEPTH SOUNDER AS REQUIRED BY 33 CFR 164.35(I).
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Electrical
Issued 5 June 1987
Resolved
REPAIR PERMANENT WIRING AND REMOVE TEMPORARY WIRING TO ANCHOR LIGHT.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Accommodation/Occupational Safety
Issued 5 June 1987
Resolved
RENEW VENTILATION DUCTS IN FOC'S'LE IN-WAY-OF ALL WASTED AREAS.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Unknown
Issued 8 September 1986
Resolved
PRESSURE TEST FIXED CARGO PIPING SYSTEM AND LABLE SAME.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
RENEW FLAME SCREENS FOR FORWARD FUEL OIL VENTS AND AFT LUBE OIL TANK VENTS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
PRIOR TO LOADING CARGOES REQUIRING CLOSED GAUGING MAKE PERMANENT REPAIRS TOALL CLOSED GAUGING DEVICES AND DEMONSTRATE THEIR OPERATION TO A CG MARINE INSPECTOR.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
MAKE PERMANENT REPAIRS TO FIRE STATION VALVE LOCATED ON FORECASTLE.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
PRIOR TO CARRYING CARGOES REFERENCED BY 4.14 OF IMO CODE MAKE REPAIRS TO THE 96% AND 98% ALARMS AND DEMONSTRATE OPERATION OF SAME TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
PROVIDE CURRENT C&R LIST FROM COMDT (G-MTH-1) REFLECTING ISSUE DATE OF NEWIMO CERTIFICATE OF FITNESS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
MAKE PERMANENT REPAIRS TO DECK EYE WASH AND EMERGENCY SHOWER.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
MAKE TEMPORARY REPAIRS TO LEAK IN FIRE MAIN LOCATED JUST AFT OF DECK ISOLATION VALVE AMIDSHIPS, PERMANENT REPAIRS TO BE MAKE PRIOR TO ENTERING U.S. WATERS AFTER 22 SEP 86.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
PROVIDE FOUR (4) COMPLETE SOLAS FIREMAN'S OUTFITS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
FREE UP FIRE MAIN DECK ISOLATION VALVE LOCATED AMIDSHIP.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
INSTALL TWO (2) ISOLATION VALVE HAND WHEELS IN FIRE MAIN LOCATED JUST FORWARD OF HOUSE.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986
Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY FIRE PUMP.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Navigation
Issued 20 June 1986
Resolved
33CFR164.33(A)(2)(II) LIGHT LIST OUTDATED.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Navigation
Issued 20 June 1986
Resolved
33CFR88.05 NO INLAND NAVIGATION RULES ONBOARD.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Documentation
Issued 20 June 1986
Resolved
33CFR151.25(A) NO OIL RECORD BOOK PART II FOR CARGO/BALLAST OPERATIONS ONBOARD.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Deck/Cargo
Issued 20 June 1986
Resolved
33CFR156.130(A)(4) NO BOLT IN EVERY HOLE OF A PERMANENTLY CONNECTED FLANGE.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Navigation
Issued 20 June 1986
Resolved
33CFR164.33(A)(2)(I)COAST PILOT OUTDATED.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Documentation
Issued 20 June 1986
Resolved
33CFR151.19(D) NO SUPPLEMENT FORM B FOR TANKSHIPS TO THE IOPP CERTIFICATE.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Accommodation/Occupational Safety
Issued 20 June 1986
Resolved
33CFR159.7(C)(1) TYPE III MARINE SANITATION DEVICE INOPERABLE.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Navigation
Issued 20 June 1986
Resolved
33CFR164.33(A)(3)(II) TIDAL CURRENT TABLES OUTDATED.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Deck/Cargo
Issued 5 June 1985
Resolved
CARRYING CARGO THAT WAS NOT AUTHORIZED BY U.S.C.G.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Documentation
Issued 5 June 1985
Resolved
NO 46 CFR 35, 150, AND 153 ON BOARD, A VIOLATION OF 46 CFR 153.905.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Documentation
Issued 5 June 1985
Resolved
OPERATING A VESSEL WITHOUT A CERTIFICATE OF FINANCIAL RESPONCIBILITY, A VIOLATION OF 33 CFR 130.3
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Engineering
Issued 5 June 1985
Resolved
INADEQUATE FUEL/BULK LUBE OIL DISCHARGE CONTAINMENT, A VIOLATION OF 33 CFR 155.320.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Documentation
Issued 5 June 1985
Resolved
OIL RECORD BOOK NOT PROPERLY MAINTAINED, A VIOLATION OF 33 CFR 151.25(J).
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Documentation
Issued 5 June 1985
Resolved
OIL TRANSFER PROCEDURES WERE INCOMPLETE, A VIOLATION OF 33 CFR 155.720.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985