MAURY USCG vessel records
← All vessels

MAKOA

Built
1976
Last inspected
17 February 2009
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 17 February 2009
…with no type recorded28
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1982–2009)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-51926

Documentation record

Tonnage as PSIX records it2850 - Regulatory (Subpart C or D), Gross Ton
2850 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 77 inspections, each with its date, unit and type; 95 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KAILANI Towing Vessel · MISLE 146682 · 22 January 2004 · activity 1994358SOUTHERN DAWN Towing Vessel · MISLE 360332 · 7 January 1993 · activity 180589POINT DEFIANCE Towing Vessel · MISLE 191621 · 28 October 1992 · activity 59421

Inspection history · 77

17 February 2009 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3418863
10 February 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3415313
10 November 2008 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3360741
16 April 2008 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3185814
29 November 2007 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3112905
24 October 2007 Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3089525
8 November 2006 Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2803329
17 November 2004 MTSA Verification · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2241698
22 January 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1994358
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957678
23 October 2003 Periodic Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1922443
11 December 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1715796
26 November 2002 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1716616
23 October 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1696310
23 September 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1677544
25 October 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362503
13 September 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382029
19 November 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365462
17 November 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365407
19 September 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372362
16 January 1998 Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1424515
17 December 1997 Drydock Extension · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375217
12 October 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363814
12 April 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1392434
8 April 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1077935
16 March 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377649
8 February 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661249
10 January 1996 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387916
26 May 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414487
15 March 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363266
26 November 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358615
19 October 1994 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358577
8 September 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661245
8 September 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1178008
22 July 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374075
10 November 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1454044
10 February 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 829719
7 January 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 180589
7 January 1993 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354227
30 December 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1139185
11 November 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961346
28 October 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 59421
19 August 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 943416
6 January 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 946187
13 November 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 932286
13 November 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1243976
6 June 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 522794
3 May 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 461511
2 May 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 479522
19 April 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 901872
29 March 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 477656
28 March 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 521464
1 March 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 514122
28 February 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 535905
1 February 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 481530
21 January 1990 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1210874
4 December 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 510774
13 November 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 447789
28 August 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 496051
15 December 1988 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1209336
22 November 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1194295
18 October 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 516875
31 May 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 487147
16 December 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 478718
31 October 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 440920
26 October 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 499289
17 June 1987 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1310228
5 December 1986 Credit Drydock
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1316299
5 December 1986 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1322691
9 September 1986 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1313508
24 August 1986 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1000482
12 November 1985 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1298717
3 October 1985 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1299522
21 September 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970138
20 July 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277764
2 March 1982 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1277518
5 January 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 968749

Deficiency record · 95

Documentation › Safety/Response Plans/Programs › SOPEP
Issued 22 December 2008 Resolved
-The SOPEP must amend all references to Regulation 26 of Annex I, to reference Regulation 37 of Annex I of the International Convention for the Prevention of Pollution from Ships.
Due 22 January 2009
Resolved 14 May 2009
Resolution: SOPEP addressed deficiency and amended plan accordingly. SOPEP expires 11/14/2011
Construction/Loadline › Hull › Hull Plating
Issued 16 April 2008 Resolved
Make stbd fwd rake ready for inspection. Inspection to determine extent of damage prior to conducting operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 April 2008
Resolved 16 April 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 October 2007 Resolved
Starboard FWD Rake; Crop/renew two side longs FR # 2-3.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Hull Plating
Issued 24 October 2007 Resolved
STBD #1 Void; Crop/Renew BHD #3 along with side long #1 & #2. Crop/renew bottom long #21 and bilge long 17 & 20.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Bracket
Issued 24 October 2007 Resolved
STBD Void #2; FR #11 crop/renew "K" bracket and upper/lower diagonals.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 October 2007 Resolved
#4 STBD Void; Grind and reweld fracture at INBD diagonal deck FR connection FR #24.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Stool
Issued 24 October 2007 Resolved
STBD AFT RAKE; Replace wasted ladder. Crop/renew deck long #16 fracture at stern long.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 October 2007 Resolved
Port #1 Void; Crop/renew FR 6 1/2 to 7 BLKHD #5 wasted.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 October 2007 Resolved
Port #2 Void; Reweld fracture deck long #2 FR 11 - 12.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 October 2007 Resolved
Port #3 Void; FR's 18, 19 & 20 crop/renew at side longs 2 - 3.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Hull › Bracket
Issued 24 October 2007 Resolved
Port AFT Rake; Crop/renew stern log bracket #22 and FR #34 fracture.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 29 November 2007
Construction/Loadline › Markings › Load Line Mark
Issued 23 October 2003 Resolved
Permantly mark and paint loadline deck lines on both side shell. LEGACY COMPONENT DESC: Deck line
Condition: Improper/Lack of Maintenance
Due 10 November 2003
Resolved 31 October 2004
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 23 October 2003 Resolved
Replace torn fuel oil hose on port side of genertaor fuel oil tank.
Condition: Improper/Lack of Maintenance
Due 10 November 2003
Resolved 31 October 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 October 2003 Resolved
Prove satisfactory operation of port navigation light.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2003
Resolved 24 October 2003
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 23 October 2003 Resolved
Make #2 port and #4 port voids available for inspection of the centerline bulkhead. LEGACY COMPONENT DESC: #2 port and #4 port void
Due 10 November 2003
Resolved 31 October 2004
Stability › Watertight Integrity › General
Issued 23 October 2003 Resolved
Make main deck available for inspection. LEGACY COMPONENT DESC: Deck
Due 10 November 2003
Resolved 31 October 2004
Construction/Loadline › Markings
Issued 23 September 2002 Resolved
Repaint draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 23 October 2002
Resolved 23 October 2002
Resolution: Attended barge and observed satisfactory marks.
Construction/Loadline › Markings
Issued 23 September 2002 Resolved
Repaint loadline reference marks. LEGACY COMPONENT DESC: Load Line Mark
Due 23 October 2002
Resolved 23 October 2002
Resolution: Attended barge and observed satisfactory marks.
Deck/Cargo › Towing
Issued 23 September 2002 Resolved
Repair/replace damaged/corroded port & starboard top links on chain bridle. Note: Each 1st link is missing the center stud, and the 2nd & 3rd links are corroded. LEGACY COMPONENT DESC: Terminal Gear
Due 23 October 2002
Resolved 23 October 2002
Resolution: Attended barge and observed satisfactory towing bridle.
Engineering › Fuel Oil Service System
Issued 23 September 2002 Resolved
Label fuel oil emergency cut-off valve at exterior handle.
Due 23 October 2002
Resolved 23 September 2002
Resolution: Fuel oil cut-off valve was labeled.
Electrical › Electrical Distribution System (service)
Issued 23 September 2002 Resolved
Re-strap electrical power cableing as needed at forward bulkhead of deckhouse interior leading from generator box to port. LEGACY COMPONENT DESC: Cable
Due 23 October 2002
Resolved 23 October 2002
Resolution: Attended barge and observed satisfactory strapping and routing of electrical cable.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 September 2002 Resolved
Repair inoperative solar powered sternlight.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2002
Resolved 23 October 2002
Resolution: Solar panels cleaned and recharged. Sternlight is functional.
Construction/Loadline
Issued 17 November 1999 Resolved
Port #4 pump room: Crop and renew bottom shell plating IWO: frs 20-22 & longs 3-18; frs 23-24 & longs 9-10; frs 23-24 & longs 15-16; frs 25-26 & logs 14-18; frs 24-25 & longs 21-22. Plate sizes(16'x4')(8'x6')(16'x3') (19'x8')(5'x5')(6'x5')(4'x3')(10'x3')(3'x2').
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Starboard #1 void: Crop and renew side shell between frames 3 1/2-6 1/2 (4'x 20')
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #2 void: Crop and renew side shell plating between frames 7 1/2 and 12(6'x 35').
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #3 Ballast: Crop and renew side shell between frames 19-20 in way of side long #3 (5' x 3').
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #4 pump room: Crop and renew side shell between frames 20-24 in way ofside longs #1-4 (5' x 30')_x001C_ _x001C_
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #1 void: Crop and renew damaged framing associated with side shell renewal.
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Starboard forward rake: Crop and renew approx 120 sq ft of shaped knuckle wrapper plate at bottom of side shell connection between frames 0-3.
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #5 ballast tank: Crop and insert 6'x6' section of main deck straddlingcenterline bulkhead at aft end of #5 tank for access to space for internal repairs.
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port aft rake: Crop and rewnew side shell in way of frames 33 1/2-34 1/2 (8' x 4')
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Starboard #2 void: Crop and renew side shell plate between frames 7 1/2-11 (5'x 28')
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Starboard #5 ballast tank: Crop and renew main deck at bulkhead frame 31 inway of U/D longs #2-3 (4'x4')
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Starboard aft rake: Crop and renew side shell in way of frames 34 1/2-35 (3'x 4')
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port & Starboard aft rakes: Crop and insert two prior undersized unapprovedinserts in aft rake bottom plating in way of forward bulkhead; located approx. 20' to port & starboard of centerline (Both sized at 18" x 24")
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #2 void: Renew interal framing associated with side shell renewal.
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #3 ballast: Crop and renew approx. 70% of U/D framing between frames 17 thru 20.
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #5 ballast tank: Crop and renew approx. 70% of U/D framing between frames 26 thru 31.
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Starboard #3 ballast tank: Crop and renew approx. 70% of U/D framing between frames 14 thru 20._x001C_ _x001C_
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Starboard #5 ballast tank: Crop and renew approx 80% of the U/D framing between frames 28 thru 30.
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port Forward Rake: Crop and renew bottom 2' section of side shell between frames 1 1/2 (2.0'x 18") and lower 5' section of frame 2 1/2 (5.0"x 18")
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 17 November 1999 Resolved
Port #1 void: Crop and insert side shell plate in way of unapproved prior repair at frame 8 adjacent to bilge kuckle (4' x 4' x 1/2").
Condition: Unknown
Due 17 November 1999
Resolved 1 December 1999
Electrical
Issued 17 December 1997 Resolved
REMOVE LAGGING AND REPAIR EXHAUST LEAK ON DIESEL GENERATOR. COMPLETE NLT 23JAN97.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Construction/Loadline
Issued 17 December 1997 Resolved
DRAIN AND GAS FREE #5P & 5S BALLAST TANKS FOR COMPLETION OF ISE. COMPLETE NLT 03JAN98.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Documentation
Issued 12 October 1996 Resolved
Vessel does not have a Coast Guard approved SOPEP. The vessel is permittedto operate for thirty days pending Coast Guard approval of the vessel's SOPEP. Revise the SOPEP in accordance with Coast Guard HQ #16460 letter dated July 17, 1995 and submit to Coast Guard HQ for approval.
Condition: Unknown
Due 12 October 1996
Resolved 12 October 1996
Engineering
Issued 12 October 1996 Resolved
Found that exhaust insulation was missing from the exhaust manifolds and the piping on the generator. Properly install exhaust lagging.
Condition: Unknown
Due 12 October 1996
Resolved 12 October 1996
Engineering
Issued 12 October 1996 Resolved
Found that vsl engineer could not prove operation of generator low lube oilpressure, high jacket water temperature, and overspeed safety devices. Prove operation of all three safety devices.
Condition: Unknown
Due 12 October 1996
Resolved 12 October 1996
Electrical
Issued 12 October 1996 Resolved
Found that two blanks were missing from openings in power panel #1 labeled "Pump Room Feed Main Distribution Panel". Install the two blanks.
Condition: Unknown
Due 12 October 1996
Resolved 12 October 1996
Construction/Loadline
Issued 10 January 1996 Resolved
MAKE HULL MARKINGS LEGIBLE.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Construction/Loadline
Issued 10 January 1996 Resolved
REPLACE 2 BROKEN DOGS IN BALLAST TANK 5P.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Engineering
Issued 10 January 1996 Resolved
REPAIR EXHAUST GAS LEAK FROM DIESEL GENERATOR.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, crop and renew deepweb frames #1, #2 (from aft bulkhead) and associated sidelongs and brackets.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, V and Weld crack at top of longitudinal diagonal stiffener, first stanchion from outboard, going from deepweb transverse #2 to #3.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, V and Weld multiple cracks at bottom longitudinals at deepweb transverse #2, at first stanchion from outboard._x001C_
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, V and Weld crack at bottom longitudinal beneath 2nd transverse deepweb, at 2nd stanchion inboard.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, V and Weld fractured weld on longitudinal diagonal stiffener at first outboard deepweb longitudinal, second deepweb transversefrom aft bulkhead.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, V and Weld as necessary cracks at top of vertical stanchions at #2 deepweb transverse (from aft), at #2 deepweb longitudinal from centerline.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, at base of vertical stanchion at #2 deepweb transverse and #2 deepweb longitudinal, dye penetrant test for possible crack on aft side of I-beam at weld with deepweb transverse.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, Crop and Renew bottom of #2 aft bulkhead deepweb frame.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, Crop and renew bottom of #3 aft bulkhead deepweb frame.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port #1 Void, Crop and Renew Brackets and side longitudinals #3, #4, #5,at aft outer corner.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port #1 Void, Crop and Renew forward bulkhead, approximately 2' x 6', atsideshell.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port #1 Void, V and Weld cracks (4, marked) at tops of transverse and longitudinal deck stiffeners.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port #1 Void, Dye penetrant test possible cracks in areas at tops of longitudinal and transverse deck stiffeners marked with "???".
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port #1 Void, Crop and renew top of side deepweb frame #2 from aft.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port #4 'pumproom', Crop and renew frames #1, #2, #3 (from forward), the top six feet approximately.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Electrical
Issued 15 March 1995 Resolved
In Port #4 'pumproom', provide closure for electric panel box #2.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
For all spaces, repair and refurbish deck access hatches as necessary, to include, but not limited to, coamings, gaskets, and dogs.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Starboard #2 Void, Crop and renew aftmost deepwed frame, from approximately the second side longitudinal upward.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Starboard #1 Void, Crop and Renew deepweb frames #1, #2, #3, #4, #6, #7 as marked (numbered from aft).
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Starboard #1 Void, Crop and renew sideshell from first bay to sixth bay,numbered from aft, approximately 20' x 6'.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Starboard #1 Void, provide adequate soft patch for crack in sideshell atfourth footwell from bottom, at the side ladder. Provide photos of same for clearance. This requirement to be completed prior to sailing from Hilo, Hawaii.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Starboard #4 Void, Crop and renew sideshell in fifth bay from aft, at fourth and fifth side longitudinals, approximately 2' x 3'.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Starboard #5 Ballast, Crop and renew aft bulkhead at sideshell, approximately 2' x 4'.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Aft Rake, Crop and Renew two aftmost deepweb frames and associated internals.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 15 March 1995 Resolved
In Port Forepeak, V and Weld cracks in #2 vertical stanchion inboard on 2nddeepweb transverse from forward.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Construction/Loadline
Issued 19 October 1994 Resolved
CHALK TEST THE WATERTIGHT HATCH, THEN GAS FREE AND MAKE AVAILABLE FOR INTERNAL EXAMINATION THE AFT RAKE TO DETERMINE THE REASON FOR THE PRESENCE OF WATER.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Construction/Loadline
Issued 19 October 1994 Resolved
REPAINT IN CONTRASTING COLOR VESSEL NAME ON THE PORT AND STBD SIDES OF THE BOW.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Navigation
Issued 19 October 1994 Resolved
PROVE PROPER OPERATION OF THE STERN LIGHT PRIOR TO VESSEL SAILING.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Construction/Loadline
Issued 19 October 1994 Resolved
CROP AND RENEW BUCKLED SIDE SHELL STIFFENERS AT PORT FRAMES #22, 23 AND 24 LOCATED IN THE BALLAST PUMP ROOM, FOUR FEET BELOW THE MAIN DECK.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Construction/Loadline
Issued 19 October 1994 Resolved
PROVE OPERATION OF SEIZED DOGS ON WATERTIGHT DOOR AND ALL WATERTIGHT HATCHES.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Construction/Loadline
Issued 19 October 1994 Resolved
RENEW FAULTY GASKET ON #2 STBD VOID WATERTIGHT HATCH.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Construction/Loadline
Issued 19 October 1994 Resolved
RENEW DAMAGED WATERTIGHT HATCH COVER TO #2 STBD AFT BALLAST TANK.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Fire Fighting
Issued 19 October 1994 Resolved
PERFORM ANNUAL SERVICING ON THE FOLLOWING PORTABLE FIRE EXTINGUISHERS: CO2 IN GENERATOR SPACE, CO2 AND DRY CHEMICAL IN BALLAST PUMP ROOM.
Condition: Unknown
Due 19 October 1994
Resolved 19 October 1994
Electrical
Issued 22 July 1994 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIP ON THE S/S GENERATOR.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Construction/Loadline
Issued 7 January 1993 Resolved
RENEW SIDE SHELL PLATE BETWEEN FRAMES 14-18, INSERT WILL BE 22'x 8' AS MARKED IN VESSEL. REPAIR FRAMES #15, 16 AND 17 AS MARKED. REPAIR WILL BE A PERMANENT REPAIR, COMPLETED TO THE SATISFACTION OF OCMI OF HONOLULU AND THEATTENDING MARINE INSPECTOR NO LATER THAN 14JAN93.
Condition: Unknown
Due 12 January 1993
Resolved 12 January 1993
Electrical
Issued 11 November 1992 Resolved
INSTALL A REMOTE FUEL SHUT OFF FOR THE GENERATOR.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Electrical
Issued 11 November 1992 Resolved
CORRECT THE PARTIAL GROUND ON THE MAIN POWER DISTRIBUTION PANEL.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 11 November 1992 Resolved
PROPERLY MARK THE VESSEL'S NAME AND DRAFT MARKS.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Electrical
Issued 11 November 1992 Resolved
INSTALL A REMOTE GENERATOR SHUT DOWN.
Condition: Unknown
Due 11 November 1992
Resolved 11 November 1992
Construction/Loadline
Issued 13 November 1991 Resolved
CROP AND RENEW SECTION OF SIDE SHELL (APPROX. 7 FT. BY 5 FT., TOP END APPROX. 3 FT. BELOW MAIN DECK ON PORT SIDE) IN WAY OF TRANSVERSE BULKHEAD BETWEEN #2P VOID AND #3P SW BALLAST TANK, AND ALL ASSOCIATED DAMAGED INTERNALS.
Condition: Unknown
Due 13 November 1991
Resolved 13 November 1991
Electrical
Issued 13 November 1991 Resolved
LOCATE AND ELIMINATE CAUSE OF ELECTRICAL GROUND IN PHASE B CIRCUIT.
Condition: Unknown
Due 13 November 1991
Resolved 13 November 1991
Documentation
Issued 21 January 1990 Resolved
PROVIDE MSO HONOLULU WITH COPY OF GAUGING REPORT FROM CREDIT DRYDOCKING COMPLETED 21 JAN 90.
Condition: Unknown
Due 21 January 1990
Resolved 21 January 1990
Construction/Loadline
Issued 9 September 1986 Resolved
UPON COMPLETION OF OFFLOADING OF DECK CARGO OF PIPE, THE BARGE IS TO PRO- CEED UNLADEN TO DRY DOCK FACILITY FOR PERMANENT REPAIRS TO SIDE SHELL AND ASSOCIATED INTERNALS IN PORT FORWARD RAKE AND #1 PORT VOID.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Construction/Loadline
Issued 24 August 1986 Resolved
UPON COMPLETION OF OFFLOADING OF DECK CARGO OF PIPE THE BARGE IS TO PROCEEDUNLOADED TO DRY DOCK FACILITY FOR PERMANENT REPAIRS TO BOTTOM PLATING AND ASSOCIATED INTERNALS IN #3 & 4 PORT VOIDS NO LATER THAN 25 SEPT 1986.
Condition: Unknown
Due 24 August 1986
Resolved 24 August 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.