MAURY USCG vessel records Sign in
← All vessels

GSF HIGH ISLAND IV

GSF HIGH ISLAND IV is a 1980 mobile offshore drilling unit. The Coast Guard has recorded 97 inspections since 1983, most recently in February 2006, along with 172 deficiencies and 2 casualty investigations between 2002 and 2004.

Records from 1983 to 2006. Most recent: inspection, 2 February 2006.

Built
1980
Last inspected
2 February 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8751411 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
VANUATU
—
Maury page id
psix-52027

Inspections, by type

…with no type recorded28
Years with a record 24 calendar years (1983–2006)
The 97 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3520 - Regulatory (Subpart C or D), Net Ton
4483 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WYQ9879MMSI not assigned · expired · compulsorily equipped · granted 13 April 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BERTO L MILLER Offshore Supply Vessel · MISLE 501910 · 10 April 2003 · activity 1775720MR COLBY Offshore Supply Vessel · MISLE 486254 · 23 September 2000 · activity 60461

Inspection history · 97

2 February 2006 COC-MODU Annual
Type not classified · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2878771
29 May 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2392452
2 November 2004 COC-MODU Renew
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2226409
10 March 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2022327
28 May 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1804583
10 April 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1775720
28 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764318
20 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760194
30 August 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1676041
30 August 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1726629
12 August 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1660488
10 June 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1629237
11 February 2002 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1485522
4 December 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 773171
26 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073186
25 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073137
26 July 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070714
16 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065382
6 June 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1066140
8 May 2001 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1384762
16 March 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450581
23 September 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 60461
18 May 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 818102
11 April 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454789
6 March 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815789
7 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1201874
31 August 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116390
2 April 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 647026
16 March 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465456
10 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803840
25 January 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410015
19 January 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212911
8 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807939
28 May 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791727
19 May 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791681
20 April 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388517
13 February 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112165
2 December 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 775636
14 November 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 786268
2 September 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120205
24 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115856
10 July 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 778519
15 May 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1096964
1 April 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1101695
25 March 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441203
3 February 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1104069
10 December 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1093377
10 September 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 952523
22 May 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1084851
18 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212697
18 April 1996 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427198
14 November 1995 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1189348
14 August 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1183156
27 June 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1190890
10 May 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1208817
29 March 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431512
20 June 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1021476
28 March 1994 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1467860
10 January 1994 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 853423
7 June 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1139596
30 April 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1146748
29 March 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447228
12 May 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1269462
14 April 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267156
9 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236010
3 May 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1326655
4 April 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 918126
14 March 1991 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 913681
27 February 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234795
10 January 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 902648
2 May 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231610
26 April 1990 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 912520
16 January 1990 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1244153
12 December 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921276
27 June 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891434
2 June 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349787
23 May 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209520
11 April 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040393
7 April 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200332
22 March 1988 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1351142
22 December 1987 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1331552
10 February 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007399
13 June 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302067
12 May 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295161
22 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 981439
20 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1295328
16 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 982668
21 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979430
28 February 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 981018
28 February 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286470
12 February 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1283538
13 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280762
3 February 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278547
27 October 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279506
11 April 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966735
11 April 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277513
4 March 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1273570

Deficiency record · 172

Documentation › Certificates/Documents › MODU Safety Certificate
Issued 27 February 2007 Resolved
Provide valid Flag State and Class Certificates prior to departing port
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2007
Resolution: Received Interum Certificates from ABS.
Fire Fighting › Fire Pumps › Power Source
Issued 27 February 2007 Resolved
Prove proper operation of fire pumps
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 February 2007
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 27 February 2007 Resolved
Provide loss of purge alarm for pressurized PA System electrical box behind "A" Drawworks motor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 February 2007
Stability › Watertight Integrity › Weathertight Enclosure
Issued 27 February 2007 Resolved
Provide proper gaskets on watertight all doors located below the main deck.
Condition: Improper/Lack of Maintenance
Due 27 February 2007
Resolved 27 February 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 February 2007 Resolved
Renew fiber gasket on lower stairtower door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 February 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 February 2007 Resolved
Align emergency lighting to adequately illuminate exit paths.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2007
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 9 November 2004 Resolved
Remove temporary quarters or install to the satisfaction of flag state.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 28 April 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 November 2004 Resolved
Revise and clarify operating instructions on fixed CO2 system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 28 April 2006
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 9 November 2004 Resolved
Revise fire control plan for submittal to flag state.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 December 2004
Resolved 28 April 2006
Fire Fighting › Structural - A Class Divisions
Issued 10 June 2002 Resolved
Properly re-install structural fire protection insulation to original A-60 protection in the overhead of the mud pit room below the crews quarters. LEGACY COMPONENT DESC: Decks - Accommodation Spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 9 August 2002
Resolution: Received digital pictures of overhead in mud pit room where A-60 insullation has been reinstalled. Certificates for material used was faxed to MSO Mobile.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 10 June 2002 Resolved
Properly pack wire transits in passageway overhead on 01 level.
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 10 June 2002
Resolution: Re-examined transits and found all wire penetrations tight.
Lifesaving › Lifebuoys
Issued 10 June 2002 Resolved
Replace retro-reflective material on lifebuoys as necessary throughout vessel. LEGACY COMPONENT DESC: Retro reflective material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2002
Resolved 10 June 2002
Resolution: All retro reflective material was replaced on lifebuoys.
Engineering
Issued 8 May 2001 Resolved
CROP AND RENEW SALTWATER LINES WHERE HOLED AND LEAKING IN PORT STORE ROOM AND VOID #27.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 8 May 2001 Resolved
CROP AND RENEW HORIZONTAL FLANGE PLATES IN PRELOAD #28 AT FRAMES #21 AND #23.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 8 May 2001 Resolved
CROP AND RENEW WASTED AND/OR HOLED AREAS WHERE HOUSE MEETS MAIN DECK.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 8 May 2001 Resolved
CONDUCT PHASE II SEILODD.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 8 May 2001 Resolved
CROP AND RENEW WASTED BOTTOM PLATE OF PRELOAD #2 BETWEEN FRAMES 0 AND 1.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Construction/Loadline
Issued 8 May 2001 Resolved
CROP AND RENEW VERTICAL SIDE LONG IN PRELOAD #9 WHERE WASTED AND/OR HOLED.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Fire Fighting
Issued 16 March 2001 Resolved
Implement onboard training in the use of the unit's lifesaving and firefighting appliances to regular crew and service hands every two months or at the same interval as the drills. Document properly, Ref: 46 CFR 109.213(g)
Condition: Unknown
Due 14 April 2001
Resolved 17 May 2001
Lifesaving
Issued 16 March 2001 Resolved
Send in life raft #3 for annual servicing. Submit copy of service certificate to [name withheld].
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Fire Fighting
Issued 16 March 2001 Resolved
Make all interior fire doors self-closing and latching. Remove hold back devices.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Lifesaving
Issued 16 March 2001 Resolved
Have outdated SCBA air bottles hydrostatically tested and serviced; Steel bottles due every 5yrs.; Composite bottles due every 3yrs.
Condition: Unknown
Due 2 April 2001
Resolved 2 April 2001
Construction/Loadline
Issued 16 March 2001 Resolved
Crop and renew wasted hand rails and deck grating throughout rig as necessary.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Electrical
Issued 16 March 2001 Resolved
Conduct and log operational load test of emergency batteries every six (6) months.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Construction/Loadline
Issued 16 March 2001 Resolved
Crop and renew wasted door threshold at mud pits. Doors are to be self- closing and gas tight.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Accommodation/Occupational Safety
Issued 16 March 2001 Resolved
Remove unapproved temporary quarters building from rig.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Unknown
Issued 16 March 2001 Resolved
Complete Coast Guard issued worklist (attached) to the satisfaction of OCMIMorgan City.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Construction/Loadline
Issued 16 March 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Lifesaving
Issued 16 March 2001 Resolved
Conduct fire and abandonment drills in the presence of a Coast Guard marineinspector.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Accommodation/Occupational Safety
Issued 18 May 2000 Resolved
PROVIDE PROOF/DOCUMENTATION THAT FIBERGLASS GRATING IN WAY OF ESCAPE ROUTESAND LIFEBOAT EMBARKATION IS CG APPROVED AND INSTALLED I.A.W. CG POLICY. IFNOT CG APPROVED REMOVE AND REPLACE.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 11 April 2000 Resolved
Replace the quick-acting water tight door handle on the port side generatorroom.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Lifesaving
Issued 11 April 2000 Resolved
Remove all fiberglass grating from escape routes/embarkation stations.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 11 April 2000 Resolved
Plug and/or crop and renew holes in paint locker.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Construction/Loadline
Issued 11 April 2000 Resolved
Make permanent repairs to bilge pump room exhaust fan.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Electrical
Issued 11 April 2000 Resolved
Make permanent repairs to the raw water cooling line in way of #1 Generator.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Fire Fighting
Issued 11 April 2000 Resolved
International shore connection at fire station #10 - replace.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Construction/Loadline
Issued 25 January 1999 Resolved
COMPLETE UNDERWATER PORTION OF HULL EXAM. PROVIDE COPY OF DIVE REPORT AND VIDEO TO THE [name withheld].
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Construction/Loadline
Issued 25 January 1999 Resolved
PROVIDE COPY OF SURVEY REPORT AND REPAIR PROPSAL FOR THE SIDE SHELL, BOTTOMSHELL AND STIFFENERS TO BE REPLACED IN PRE-LOAD TANKS TO THE [name withheld].
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Unknown
Issued 28 May 1998 Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 1.1 TIMESTHE MASS OF THE BOAT WHEN LOADED WITH ITS FULL COMPLEMENT.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Lifesaving
Issued 20 April 1998 Resolved
Remove or provide valid documentation on approval for fiberglass deck grating in machinery space. Submit to [name withheld].
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 20 April 1998 Resolved
Renew wasted deck grating on outboard side of port leg well.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 20 April 1998 Resolved
Renew gaskets to hatches on life capsule number two.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Lifesaving
Issued 20 April 1998 Resolved
Conduct operational test of lifeboat release gear under a load of 1.1 timesthe mass of the boat when loaded with its full complement.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Deck/Cargo
Issued 25 March 1997 Resolved
REPLACE ALL BULK TANK RELIEF VALVES (3) THAT ARE MISSING THEIR MANUFACTURER'S DATA PLATES.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Electrical
Issued 25 March 1997 Resolved
AFTER COMPLETING MAJOR OVERHAUL OF #2 GENERATOR, PERFORM FOLLOWING SHUTDOWNS/TRIPS ON #2 GENERATOR: LOW LUBE OIL, OVERSPEED, AND REVERSE POWERRELAY. SUBMIT STATEMENT OF FACT TO MARINE SAFETY OFFICE PORT ARTHUR FROM OFFSHORE INSTALLATION MANAGER REGARDING RESULTS OF THE ABOVE TESTS.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Lifesaving
Issued 25 March 1997 Resolved
PERFORM IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR OR HAVE THIRD PARTY PERFORM A WEIGHT TEST OF BOTH LIFERAFT DAVITS. SUBMIT COPIES OF WEIGHT TEST RESULTS TO MARINE SAFETY OFFICE PORT ARTHUR.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Fire Fighting
Issued 25 March 1997 Resolved
INSTALL MISSING SUPPORT BRACKETS FOR CO2 BRANCH LINES IN MUDPIT ROOM.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Fire Fighting
Issued 25 March 1997 Resolved
POST PROPER OPERATING INSTRUCTIONS AT THE LOCAL ACTUATING STATION FOR THE CO2 SYSTEM TO THE ENGINEROOM AND MUDPIT ROOM.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Lifesaving
Issued 25 March 1997 Resolved
REPLACE AFT-MOST WINDOW IN LIFEBOAT #2.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Fire Fighting
Issued 25 March 1997 Resolved
REPAIR INOPERABLE SMOKE DETECTOR IN LOWER LEVEL CHANGE ROOM.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Electrical
Issued 25 March 1997 Resolved
INSTALL BLANKS IN ELECTRICAL PANEL L-22 IN RECREATION ROOM.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Construction/Loadline
Issued 10 December 1996 Resolved
COMPLETE 6 SEPARATE INSERTS ALONG OUTBOARD BULKHEAD IN PRELOAD TANK #8S AS PER REPAIR PROPOSAL ON FILE AT PATMS DATED 10DEC96.
Condition: Unknown
Due 10 December 1996
Resolved 10 December 1996
Construction/Loadline
Issued 10 September 1996 Resolved
BASED ON GAUGING REPORTS DATED 04SEP96 & 30MAY96, SUBMIT A REPAIR PROPOSAL FOR ALL WASTED AREAS TO THE COGNIZANT OCMI.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Documentation
Issued 10 September 1996 Resolved
SUBMIT FOR A COAST GUARD STABILITY REVIEW DUE TO RECENT WEIGHT CHANGES FROM1996 DRYDOCK.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Lifesaving
Issued 10 September 1996 Resolved
ACQUIRE SERVICE OF A STANDBY VESSEL UNTIL REPAIRS TO LIFEBOAT #2 ARE COMPLETE. SUBMIT COPY OF STANDBY VESSEL'S CERTIFICATE OF INSPECTION TO MSO PORT ARTHUR. VESSEL MUST MEET REQUIREMENTS IN 33 CFR 143.
Condition: Unknown
Due 11 September 1996
Resolved 12 September 1996
Lifesaving
Issued 10 September 1996 Resolved
PERFORM WEIGHT TEST OF LIFEBOAT #1.
Condition: Unknown
Due 10 September 1996
Resolved 10 September 1996
Lifesaving
Issued 10 September 1996 Resolved
MAKE NECESSARY REPAIRS TO LIFEBOAT #2 DUE TO WATER DAMAGE.
Condition: Unknown
Due 11 September 1996
Resolved 12 September 1996
Construction/Loadline
Issued 18 April 1996 Resolved
P-21, FWD: CROP AND RENEW BOTTOM FOUR OUTBOARD TRIP BRACKETS AT FRAME 20 AND ATTACHED BOTTOM FOUR LONGITUDINALS ON SIDE SHELL. PAD WELD PITS IN VICINITY AS NECESSARY. WELD TWO HOLES IN OVERHEAD/DECK.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
HATCH REPAIRS. P-21, FWD.: REPAIR KNIFE EDGE, CROP AND RENEW WASTED METAL, REPLACE GASKET. P-4: REPLACE DOGGING EARS/STRIKE PLATES.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
S-22, FWD.: RENEW BOTTOM LADDER SUPPORT ANGLE, INSTALL SOUNDING TUBE SUPPORT BRACKET, PAD WELD PITS IN SIDE SHELL, GUAGE PITTING ON AFT BKHD. 4 FT. OFF DECK, RENEW STIFFENER BRACKETS AROUND JACKING SUPPORT AS NEC.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
S-8: GUAGE BETWEEN 4 AND 8 FT. IN AFT BAY ON SIDE SHELL, AFT BKHD. AND INBOARD BKHD. RENEW REACH ROD SUPPORT BRACKETS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
P-4: PAD WELD PITS IN SIDE SHELL AS NECESSARY.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
P-29: CROP AND RENEW WASTED BILGE SUCTION PIPE.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
PERFORM UNDERWATER INSPECTION OF SPUD CANS AND CRITICAL CONNECTIONS TO THE SATISFACTION OF ATTENDING COAST GUARD INSPECTOR AT NEXT RIG MOVE.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
S-22, AFT: GUAGE SIDE SHELL AND STBD. SIDE OF AFT BKHD. BETWEEN #2 AND 3 HORIZONTAL STIFFENERS.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
REPLACE TWO BREATHING AIR BOTTLES WITH LOW PRESS. IN LIFE BOAT #2.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Lifesaving
Issued 18 April 1996 Resolved
PERORM 110% WEIGHT TESTS FOR LIFEBOATS #1 & 2 PER FALLS RENEWAL.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996 Resolved
SEACHEST VOID: REMOVE SCALE AND ARREST CORROSSION ON SEACHEST BOX AND SPOOLPIECE.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Unknown
Issued 29 March 1995 Resolved
OPEN, CLEAN AND GAS FREE VESSELS CEMENT AND BARTITE TANKS FOR INTERNAL EXAMINATION AT NEXT RIG MOVE OR PRIOR TO 29SEP95.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Construction/Loadline
Issued 20 June 1994 Resolved
COMPLETE REPLACEMENT OF ANGLE STIFFNERS AS REQUIRED BY ABS AS A RESULT OF THE UT TEST REPORT RESULTS TAKEN BY TEXAS NDT TECHNOLOGIES, INC BETWEEN 10-18 MAY 94. TANKS ENVOLVED WERE 3P, 8S, 9P, 15P, 16S, 21FP, 22FS. NOTIFY MSO PORT ARTHUR WHEN REPAIRS ARE COMPLETE. MSO PORT ARTHUR HAS FILE.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Construction/Loadline
Issued 10 January 1994 Resolved
PRIOR TO DEPARTURE FROM WC196 UPON COMPLETING DRILLING OPERATIONS UNIT MUSTCOMPLETE PHASE II OF SEILOD EXAM CONDUCTED ON 10JAN94. ITEMS TO COMPLETE ARE NDT OF ALL LEG TO CAN CRITICAL CONNECTIONS AND HAVE ALL MUD PIT DUMP VALVES OPEN FOR INSPECTION.
Condition: Unknown
Due 10 January 1994
Resolved 10 January 1994
Electrical
Issued 29 March 1993 Resolved
REWIRE DRILL FLOOR AS PER CURRENT HAZARDOUS LOCATION PLAN OR SUBMIT REVISEDPLAN IAW 46 CFR 111.105
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Fire Fighting
Issued 29 March 1993 Resolved
REPLACE FLANGE TO ELBOW PIPING FIRE STATION NO. 12. (LEAKING).
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 29 March 1993 Resolved
REPLACE FUEL VENTS (GOOSENECK) FROM DECK TO BELL ON FUEL TANKS 14 AND 31.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Electrical
Issued 29 March 1993 Resolved
RETEST TOTAL RIG SHUTDOWN FROM BOTH RIG FLOOR AND TOOLPUSHERS OFFICE.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Engineering
Issued 29 March 1993 Resolved
TEST FUEL TRANSFER PUMP SHUTDOWN (REMOTE).
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Fire Fighting
Issued 29 March 1993 Resolved
REPLACE FIRE PLUG NO. 8 FROM VALVE FLANGE TO DECK AND BRACKET/SUPPORT AS NECESSARY.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Fire Fighting
Issued 29 March 1993 Resolved
REPLACE ALL 1.5 INCH 75 FOOT FIRE HOSES WITH 50 FOOT HOSES.
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Electrical
Issued 14 April 1992 Resolved
INSTALL GUAQGE AT REGULATOR AND ENSURE PURGE SYSTEMS ARE INSTALLED IN ACCORDANCE WITH NFPA 496. TEST PURGE SYSTEMS IN PRESENCE OF USCG MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
MAKE FOLLOWING RPAIRS TO BOTH DAVIT LAUNCHED LIFERAFT INSTALLATIONS: RENEW CABLE RETRIEVING LINES, MARK CABLE WITH YELLOW LINE TO CORRESPOND TO DAVIT ARM YELLOW LINE, AND RENEW PULL LINES ON HOOK RELEASES(MAKE APPROXIMATELY 6' LONG)._x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
MAKE REPAIRS TO CRACKED WINDOW, AFT THROTTLE KNOB, AND LIFESAVING SIGNALS CHART COMING OFF WALL IN #2 (PORT) LIFEBOAT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Fire Fighting
Issued 14 April 1992 Resolved
FREE UP DIFFUSERS ON 4' APPLICATORS AT STATIONS #6,16, AND 17._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Accommodation/Occupational Safety
Issued 14 April 1992 Resolved
INSTALL GENERAL ALARM BELL IN SCR OFFICE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
PROVIDE THREE (3) PARACHUTE FLARES FOR RIG (ONLY NINE ON BOARD). 12 REQUIRED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Accommodation/Occupational Safety
Issued 14 April 1992 Resolved
INSTALL RELIEF VALVES ON HOT WATER HEATERS THAT ARE RATED AT 210 F AND NOT MORE THAN 100 PSI OR MAKE AVAILABLE FOR INTERNAL INSPECTION OR HYDRO TEST. INSTALL RELIEF VALVES ON SANITARY WATER AND FRESH WATER TANKS NOT MORE THAN100 PSI OR MAKE AVAILABLE FOR INTERNAL INSPECTION OR HYDRO TEST._x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Electrical
Issued 14 April 1992 Resolved
ENSURE ALL HORIZONTAL AND OVERHEAD CABLE RUNS ARE SECURED WITH METALLIC STRAPS VICE PLASTIC TIEWRAPS. RENEW OVERHEAD RUNS IN MUD PIT ROOM. PROPERLYINSTALL JUNCTION BOXES IN OVERHEAD OF SHALE SHAKER AREA._x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Accommodation/Occupational Safety
Issued 14 April 1992 Resolved
REPLACE CRACKING NON-METALLIC EXPANSION JOINT ON DESILTER(OUTBOARD) PUMP PIPING UNDER SHALE SHAKER DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Accommodation/Occupational Safety
Issued 14 April 1992 Resolved
MAKE REPAIRS TO SALT WATER PRELOAD PIPING WHERE DOUBLER INSTALLED IN MECH/ELECTRICIAN SHOP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Fire Fighting
Issued 14 April 1992 Resolved
MAKE PERMANENT REPAIRS TO LEAKING PIPING BELOW BOTTOM FLANGE OF 2ND VALVE FROM DECK AT #2 FIRE PUMP SEA SUCTION PIPING AND LEAKING PIPE ON DISCHARGE SIDE OF #2 FIRE PUMP AT AN OLD WELD REPAIR (RENEW PIPING)._x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Electrical
Issued 14 April 1992 Resolved
MAKE REPAIRS TO AFT BULKHEAD WIRING PENETRATIONS OPEN TO MUD PUMP ROOM AND CONDUIT RUNNING THROUGH BULKHEAD (FWD) ON STBD SIDE WHERE OPEN IN MUDPIT ROOM(CONDUIT END PIECE WASTED OFF)._x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
INSTALL RETROREFLECTIVE TAPE ON ALL RING BOUYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Construction/Loadline
Issued 14 April 1992 Resolved
REPLACE ALL BROKEN LIGHT LENSES ON HELO DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Fire Fighting
Issued 14 April 1992 Resolved
LABEL VENT SHUTDOWN SWITCH AND RELOCATE INSTRUCTION PLACARDS AT REMOTE PULLSTATION ON PAINT LOCKER. REWORK VENT CLOSURE HATCH.(GASKET/FREE-UP HINGES)
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 4 April 1991 Resolved
FABRICATE MEANS TO SECURE DAVIT LAUNCHED LIFERAFTS TO BOARDING DECK AS DESIGNED BY MANUFACTURER.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
PROVIDE EIGHT ADULT LIFE PRESERVERS. VESSEL SHALL CARRY NO MORE THAN 66 TOTAL PERSONS UNTIL LIFE PRESERVERS ARE ONBOARD.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Deck/Cargo
Issued 4 April 1991 Resolved
DEMONSTRATE OPERATION OF PURGE AIR SYSTEM ON DRILL FLOOR CONTROL CONSOLE.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Lifesaving
Issued 4 April 1991 Resolved
DEMONSTRATE FIRE SPRINKING SYSTEM ON #1 LIFEBOAT.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Fire Fighting
Issued 4 April 1991 Resolved
CONDUCT FIRE DRILL IN PRESENCE OF COAST GUARD INSPECTOR_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Electrical
Issued 26 April 1990 Resolved
REPAIR EMERGENCY LIGHTS (2) ON 3RD DECK PASSAGEWAY.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Construction/Loadline
Issued 26 April 1990 Resolved
PROVIDE GUARD FOR SIGHT GLASS ON GLYCOL TANK NEAR PAINT LOCKER.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Fire Fighting
Issued 26 April 1990 Resolved
RENEW FADED FIRE AND SAFETY PLAN.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990 Resolved
PROVE OPERATION OF ALL ENGINE O/SPEED ALARMS AND OVERSPEED NUMBER 3 ENGINE.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990 Resolved
REPAIR EXPLOSION PROOF LIGHT FIXTURE GLASS LENSE TUBES OVER SHALE SHAKER (2) AND MUD PIT ROOM (3).
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Documentation
Issued 26 April 1990 Resolved
PROVIDE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33CFR 155.720.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Unknown
Issued 7 April 1989 Resolved
RENEW EXPANSION JOINT PRIOR TO DRAW WORKS MOTOR BLOWERS.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Fire Fighting
Issued 7 April 1989 Resolved
REPLACE THE 2-1/2 FOOT SECTION OF THE RAW WATER SUCTION LINE TO FIRE PUMP NUMBER 1 WHICH HAS AN IMPROPER WELD PATCH.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
PRIOR TO PROVIDING POWER TO THE H2S SYSTEM, PROPERLY SUPPORT ALL WRITTING AND POUR ALL EYS FITTINGS IN THE MUD PIT ROOM AND THE SHAKER AREA.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Construction/Loadline
Issued 7 April 1989 Resolved
REPLACE THE WASTED BILGE SUCTION SCREENS IN THE BILGE PUMPROOM AND THE MUD MIX ROOM BILGE WALLS.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Construction/Loadline
Issued 7 April 1989 Resolved
CLEAN OR REPLACE THE TWO CLOGGED BILGE WELL SCREENS IN THE MUD PUMPROOM.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
PRIOR TO DRILLING MAKE THE PURGE ALARM OPERABLE ON THE WMCO PANEL IN THE DRILLERS SHACK.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
PRIOR TO DRILLING REMOVE OR PROPERLY TERMINATE THE CUT 120 VOLT WIRE IN THEMUD PIT ROOM.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
PRIOR TO DRILLING POUR THE EYS FITTING INTO THE JUNCTION BOX ON THE AFT OUTSIDE BULKHEAD OF THE DRILLRS SHACK.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
PRIOR TO DRILLING MAKE THE GENERAL ALARMS IN THE MUD MIX ROOM, MUD PUMP ROOM, SACK ROOM AND ON THE PORT LEG OPERABLE. ALL ARE ON THE SAME INOPERATIVE CIRCUIT.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REMOVE THE OIL FROM THE NUMBER 1 LIFEBOAT BILGES.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
REPLACE OR REPAIR THE WASTED DRAW WORKS A JUNCTION BOX.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REPAIR OR REPLACE THE BROKEN DOOR FRAME GASKET ON THE STARBOARD FORWARD ANDAFTER PORT LIFEBOAT NR 1 OPENINGS.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
PRIOR TO DRILLING & REPAIR OR REPLACE THE FROZEN GENERAL ALARM BELL ON THE SHAKER DECK SO THAT IT OPERATES. RESTENCIL "GENERAL ALARM WHEN BELL RINGS GO TO YOUR STATION".
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Construction/Loadline
Issued 7 April 1989 Resolved
REPAINT UNIT NAME ON THE HELIPORT.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Accommodation/Occupational Safety
Issued 7 April 1989 Resolved
PRIOR TO DRILLING MAKE THE DRILL FLOOR AIR RECIEVER OUTBOARD FORWARD PLUG OPENING AVAILABLE FOR INSPECTION OF CORROSION DAMAGE.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REPAIR THE BROKEN AIR BOTTLE VALVE ON THE MIDDLE AFT AIR CYLINDER IN LIFEBOAT NUMBER 2.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Accommodation/Occupational Safety
Issued 7 April 1989 Resolved
REPLACE THE GRATING OVER THE PORT BILGE WELL IN THE MUD PUMPROOM WITH A GRATING THAT HAS A SMALL ENOUGH WRENCH ACCESS TO PREVENT PERSONNEL TRIPPINGHAZARD.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
HAVE THE FOUR LIFERAFT HYDROSTATIC RELEASES SERVICED OR REPLACED.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REPLACE THE MISSING YELLOW MARK ON THE LIFE RAFT FALLS REFERRED TO BY THE LAUNCHING INSTRUCTIONS.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REPLACE ALL LINES ATTACHING WATER LIGHTS TO THE LIFE RING BUOYS.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REPAIR OR REPLACE THE STARBOARD AFT INOPERATIVE WATER LIGHT.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Engineering
Issued 7 April 1989 Resolved
REPAIR OR REPLACE THE WASTED FUEL OIL VENTS WHICH ALLOW AIR PAST FLAME SCREENS ON DIESEL OIL TANK 14 AND DIRTY OIL TANK 31.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Engineering
Issued 7 April 1989 Resolved
REPLACE THE HOLED FLAME SCREEN ON DIESEL OIL TANKS 13 ENSURING SCREEN SEALSOFF OPENING.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Fire Fighting
Issued 7 April 1989 Resolved
REPLACE THE BROKEN AND PARTIALLY READABLE CO2 WARNING SIGN ABOVE THE STARBOARD ENGINE ROOM WATERTIGHT DOOR.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Documentation
Issued 7 April 1989 Resolved
HAVE THE QUADRIENNAL LOAD TEST COMPLETED ON THE THREE CRANES. SUBMIT COPY OF THE REPORT TO [name withheld].
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
PRIOR TO DRILLING CLEAN THE PAINTED MATING SURFACES AND SILICONED SEALED SURFACES ON THE EXPLOSION PROOF JUNCTION ON THE DRILL FLOOR.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REPAIR THE CHAFED GUNWALES ON BOTH LIFEBOATS WHERE THEY CONTACT THE DAVIT TO PREVENT MOISTURE DAMAGE TO FIBERGLASS.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
PROVIDE A LIFEBOAT GUNWALE LADDER FOR EACH LIFE BOAT AS PER 46CFR 108.503 AND 46.20-10.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
REPAIR THE BROKEN AIR BOTTLE VALVE ON THE AFT STARBOARD AIR CYLINDER IN LIFEBOAT NUMBER 1.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
MAKE THE NUMBER 2 LIFEBOAT INTERIOR LIGHTS OPERABLE.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 22 March 1988 Resolved
PROVIDE PLANS FOR ALTERATION OF EMERGENCY GENERATOR CIRCUITS.
Condition: Unknown
Due 22 March 1988
Resolved 22 March 1988
Electrical
Issued 22 March 1988 Resolved
SUBMIT PLANS FOR PURGING OF "INSTRUMENTATION BOX" RIG FLOOR AFT PURGING TO BE IN ACCORDANCE WITH NFPA 496.
Condition: Unknown
Due 22 March 1988
Resolved 22 March 1988
Fire Fighting
Issued 10 February 1987 Resolved
HYDROSTATIC TEST ALL PORTABLE FIRE EXTINGUISHERS THAT HAVE A HYDRO DATE OLDER THAN FEB 1982.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Deck/Cargo
Issued 10 February 1987 Resolved
MAKE AVAIABLE FOR INTERNAL INSPECTION ALL BULK STORAGE TANKS.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Deck/Cargo
Issued 10 February 1987 Resolved
PROVIDE DRILL FLOOR AIR RECIEVER WITH APPROVED SAFETY RELIEF VALVE.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Deck/Cargo
Issued 10 February 1987 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF OILY WATER SEPERATION EQUIPMENT AND PROVIDE EVIDENCE THAT EQUIPMENT IS COAST GUARD APPROVED.
Condition: Unknown
Due 10 February 1987
Resolved 10 February 1987
Documentation
Issued 12 May 1986 Resolved
PROVIDE ABS LOADLINE CERTIFICATE WHICH REFLECTS CURRENT USCG STABILITY LETTER DATA.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Deck/Cargo
Issued 12 May 1986 Resolved
IN ACCORDANCE WITH 33 CFR 155.400 AND 155.420 PROVIDE DATA ON HYDROSTATIC TEST OF OIL TRANSTER HOSE.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Unknown
Issued 12 May 1986 Resolved
PROVIDE REQUIRED FIRE EXTINGUISHER FOR FORKLIFT.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Deck/Cargo
Issued 12 May 1986 Resolved
MAKE OPERATIONAL BACKING ALARM FOR FORKLIFT.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Navigation
Issued 12 May 1986 Resolved
MAKE OPERATIONAL THE STERN LIGHT.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Lifesaving
Issued 12 May 1986 Resolved
PROVE OPERATIONAL THE FOLLOWING GENERAL ALARMS SHELL SHAKER RM, PORT AFT LEG.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Fire Fighting
Issued 12 May 1986 Resolved
PROVIDE ON BOARD USCG APPROVED COPY OF FIREFIGHTING AND LIFESAVING SAFETY PLAN.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Lifesaving
Issued 12 May 1986 Resolved
TEST RELEASE HOOKS FOR DAVIT LAUNCHED LIFERAFTS NO. 2 AND 4.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Electrical
Issued 12 May 1986 Resolved
PROVE OPERATION OF MAN PIT LOSS OF VENTILATION ALARM.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Deck/Cargo
Issued 12 May 1986 Resolved
PROVIDE RELIEF VALVES OF NOT MORE THAN MAX. ALLOW WORK PRESSURE FOR THE SANITARY SYTEEM AND AIR RECEIVER ON DRILL FLOOR.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Unknown
Issued 12 May 1986 Resolved
MAKE REPAIR TO PORT NAVIGATIONAL SCREEN (LEVEL).
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Navigation
Issued 12 May 1986 Resolved
CLEAN ALL NAVIGATIONAL AND OBSTRUCTION LIGHT LENSE.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Deck/Cargo
Issued 12 May 1986 Resolved
PROVE TO THE SATISFACTION OF ATTENDING COAST GUARD INSPECTOR THE PROPER OPERATION OF THE OILY WATER SEPARATOR.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Unknown
Issued 12 May 1986 Resolved
PROVIDE PROPER LABELING OF LP-5 SWITCHBOARD.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Deck/Cargo
Issued 16 April 1985 Resolved
MAKE AVAILABLE FOR INSPECTION THE MUD PIT DUMP VALVE SEA VALVE AT THE NEXT RIG MOVE.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Construction/Loadline
Issued 16 April 1985 Resolved
MAKE PERMANENT REPAIRS TO THE AFT SIDE OF THE STARBOARD CHORD ON THE FLAT PLATE TO CHORD WELD ON THE BOW LEG. REPAIR IS TO BE MADE IN ACCORDANCE WITHSPECS IN THE CONSTRUCTION PORTFOLIO. UPON COMPLETION, A NON-DESTRUCTIVE TEST OF THE WELD SHALL BE CONDUCTED IN THE PRESENCE OF A COAST GUARD INSP.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Construction/Loadline
Issued 28 February 1985 Resolved
CONDUCT A WEIGHT TEST OF BOTH LIFEBOAT DAVITS AND LIFERAFT DAVITS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Lifesaving
Issued 28 February 1985 Resolved
CHANGE THE FUEL IN LIFEBOAT #2 AND NOTE THE CHANGE IN THE VESSEL'S LOG.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Lifesaving
Issued 28 February 1985 Resolved
REPLACE THE DISTRESS SIGNALS IN BOTH LIFEBOATS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Construction/Loadline
Issued 28 February 1985 Resolved
COMPLETE THE DRYDOCK OF THE CANS AND LEG CONNECTIONS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Lifesaving
Issued 28 February 1985 Resolved
REPLACE THE MISSING INSTRUCTIONS ON #3 INFLATABLE LIFERAFT.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Lifesaving
Issued 28 February 1985 Resolved
REPLACE THE SMOKE CANISTERS ON THE RING BUOYS.
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Unknown
Issued 3 February 1984 Resolved
PROVIDE ONE COMPLETE SEA ANCHOR FOR EACH LIFE CAPSULE AS REQUIRED BY 46 CFR108.503(D).
Condition: Unknown
Due 3 February 1984
Resolved 3 February 1984
Unknown
Issued 3 February 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE GLOMAR HIGH ISLAND IV, DN627443.
Condition: Unknown
Due 3 February 1984
Resolved 3 February 1984
Unknown
Issued 3 February 1984 Resolved
PROVIDE THE PORTABLE RADIO APPARATUS AS REQUIRED BY 46 CFR 108.519.
Condition: Unknown
Due 3 February 1984
Resolved 3 February 1984
Unknown
Issued 3 February 1984 Resolved
PROVIDE A CURRENT VESSEL DOCUMENT OF REGISTRY ON BOARD.
Condition: Unknown
Due 3 February 1984
Resolved 3 February 1984
Electrical
Issued 11 April 1983 Resolved
RENEW WASTED GENERAL ALARM LIGHT IN MUDPIT ROOM DUE TO CORRODED AND BROKEN LIGHT CASTING AT ELECTRICAL CONNECTION
Condition: Unknown
Due 11 April 1983
Resolved 11 April 1983
Construction/Loadline
Issued 11 April 1983 Resolved
REPAIR OR REPLACE THE DOOR HARDWARE TO THE FOLLOWING DOORS: (A) HOSPITAL EXTERIOR DOOR (B) 3RD LVL STAIRWAY DOOR (C) EXT DOOR TO CHANGEROOM
Condition: Unknown
Due 11 April 1983
Resolved 11 April 1983
Construction/Loadline
Issued 11 April 1983 Resolved
REPAIR OR REPLACE ALL STAIRTOWER DOOR SELF-CLOSERS.
Condition: Unknown
Due 11 April 1983
Resolved 11 April 1983
Construction/Loadline
Issued 11 April 1983 Resolved
REPAIR OR REPLACE VERTICAL LADDER AFT OF PORT LIFERAFT PLATFORM
Condition: Unknown
Due 11 April 1983
Resolved 11 April 1983

Casualty record · 2

30 August 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1676041
10 March 2004Routine · role: Involved in a Marine Casualty · activity 2022327
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GLOMAR HIGH ISLAND IV (2002–2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.