ENTERPRISE is a 1980 freight ship. The Coast Guard has recorded 31 inspections since 2016, most recently in July 2025, along with 31 deficiencies, 5 operational controls and 9 casualty investigations between 2002 and 2016.

Records from 2002 to 2025. Most recent: inspection, 11 July 2025.

Built
1980
Last inspected
11 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 July 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7617905
Flag
COMOROS
Maury page id
psix-52069

Documentation record

Tonnage as PSIX records it28219 - Convention (Subpart B), Gross Ton
13982 - Convention (Subpart B), Net Ton
30415 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 31

11 July 2025 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8183257
12 May 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8133192
8 May 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8131322
9 May 2023 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7690120
6 May 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7682112
20 April 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7672510
8 March 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7647954
30 December 2022 Annual Inspection · Deficiency Check · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7614740
11 April 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7439609
6 April 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7426723
19 October 2021 Administrative Inspection · MTSA/ISPS Verification · ACP COI Oversight · Re-Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7333010
14 July 2021 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7336698
5 February 2021 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7136572
12 November 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7094625
30 October 2020 MTSA/ISPS Verification · Deficiency Check · ACP COI Oversight · Re-Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7082593
29 September 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7068219
26 November 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6863406
15 November 2019 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6838922
10 May 2019 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6680914
5 April 2019 Examination of Repairs · Administrative Inspection · Deficiency Check · In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6656870
14 December 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6597803
30 November 2018 ACP Annual Oversight · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6572143
6 March 2018 Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6366530
23 January 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6342531
3 November 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6285965
4 October 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6281160
9 December 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6033213
25 August 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5982297
19 August 2016 ACP Periodic Oversight
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5977606
20 February 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5886927
7 January 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5794114

Deficiency record · 31

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 December 2022 Resolved
Lifeboats...shall be served by wire rope falls, together with winches of an approved type which, in the case of the emergency boats, shall be capable of quick recovery of those boats. The starboard lifeboat winch is unable to quickly recover the emergency starboard lifeboat. SOLAS III/36 (h)(i)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2022
Resolution: Received class report that the def has been resolved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 December 2022 Resolved
Every motor lifeboat shall carry portable fire-extinguishing equipment of an approved type capable of discharging froth or other suitable substance fro extinguishing oil fires. The starboard lifeboat's portable fire extinguisher was severely wasted. SOLAS III/11 (e)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 31 December 2022
Resolution: Received class report that the def has been resolved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 30 December 2022 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. The cargo hatch gaskets on multiple hatch covers were severely wasted and needed to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2023
Resolved 31 December 2022
Resolution: Received class report that ABS has taken def as condition of class.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 December 2022 Resolved
All seafarers on ships are covered by adequate measures for the protection of their health and that the have access to prompt and adequate medical care while working on board. Multiple meds were expired in hospital. ILO 147 - 46 USC 70002
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 January 2023
Resolved 30 December 2022
Resolution: Recieved satisfactory class report.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 30 December 2022 Resolved
Each ship shall provide and maintain decent accommodations and recreational facilities for seafarers working or living on board, or both, consistent with promoting the seafarers health and well-being. Multiple ventilation filters were in need of replacement, including, but not limited to, the laundry and galley. ILO 147 - 46 USC 70002
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2023
Resolved 31 December 2022
Resolution: Received class report that ABS has taken def as condition of class.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 30 October 2020 Resolved
74 SOLAS I/11 After any survey of the ship under Reg 7,8,9, or 10 of this Chapter has been completed no change shall be made in structural arrangements, machinery, equipment, etc. covered by survey, with out the sanction of the Administration. MI found the Emergency Diesel Generator to have hot exposed surfaces along both exhaust manifolds and pipe.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 January 2021
Resolution: Attended vessel, witnessed proper insulation of the emergency generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2020 Resolved
74SOLAS I/11 After any survey of the ship under Reg 7,8,9, or 10 of this Chapter has been completed no change shall be made in structural arrangements, machinery, equipment, etc. covered by survey, with out the sanction of the Administration. MI found cables hung by zip ties from cable run. Cables are located in the M.G. house adjacent to the E-generator space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 January 2021
Resolution: attended ship verified that the cables are properly support
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 October 2020 Resolved
An approved medicine chest with readily understandable instruction shall be carried in every ship which does not carry a doctor. Inspector observed medicine cabinet not readily available for emergency usage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2020
Resolved 9 November 2020
Resolution: def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 September 2020 Resolved
SSTG is operating erraatically man emergency generator space when entering or leaving port until sstg is operating properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 7 October 2020
Resolution: Received repair report from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 April 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Temp repairs were made to starboard rudder tiller arm connection. Operationally test to satisfaction of attending CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2019
Resolution: Conducted satisfactory performance test of temp repair.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 April 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Hydrostatic realeases for both liferafts were found inproperly installed. STBD liferaft painter was found to be unsecured. Rectified by ship's personnel on the spot. Liferafts serviced and reinstalled on 08 FEB 19.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 5 April 2019
Resolution: Rectified by ship's personnel on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 April 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. STBD life boat rudder fractured upon in water test. Renew rudder to original spec and perform operational in water testing to satisfaction of attending Coast Guard Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
Resolution: Rudder and tiller were renewed in kind and operationaly tested to satisfaction of attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 April 2019 Resolved
Prove proper construction and materials of both lifeboat rudders IAW OEM drawings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2019
Resolved 9 May 2019
Resolution: Received satisfactory class report for port lifeboat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 December 2018 Resolved
Starboard side lifeboat needs to be lowered, released, and run in forward and reverse, with Coast Guard Marine Inspector in attendance.
Action required: 705 - Other - as specified
Due 10 January 2019
Resolved 5 April 2019
Resolution: Lifeboat was operationally tested.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 30 November 2018 Resolved
Vessel not in condition of survey. Repair fractured weld in STBD side tunnel frame 148 outboard I-beam in overhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2018
Resolved 4 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2018 Resolved
Prove proper operation and testing of both boiler over-speeds IAW ABS and manufacture SPECS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2018
Resolved 14 December 2018
Resolution: Overspeeds tested and verified shop by [name withheld] in presence of ABS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 November 2018 Resolved
Sufficient number of nozels should be available and accessible at all times. Nozzels at fire stations 23, 22, 18A, 14B, 13, 17, 08, 15, 15C, 19, and 24, are frozzen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2018
Resolved 4 December 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 November 2018 Resolved
The condition of the ship and its equipment shall be maintained to confrom with the provisions of the present requlations to ensure that the ship in all respects will remain fit to proceed to sea with out danger to the ship and persons on board. Water applicators were found sized on port and starboard sides of the house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2018
Resolved 4 December 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 November 2017 Resolved
Weigh all CO2 bottles
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2017
Resolution: ABS wittnessed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 November 2017 Resolved
complete blow thru
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2017
Resolution: ABS wittnessed Blow thru
Fire Fighting › Portable Foam Applicators › General
Issued 3 November 2017 Resolved
Repair or Replace faom applicator main deck
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 23 January 2018
Resolution: Cleared on 1 December by ABS. See report LA3421432-A, item #1384.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 November 2017 Resolved
repair or replace float light stbd side aft of house
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 23 January 2018
Resolution: Cleared on 1 December by ABS. See report LA3421432-B, item #1385.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 November 2017 Resolved
replace all yellow line with approved line
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 23 January 2018
Resolution: Cleared on 1 December by ABS. See report LA3421432-B, item #1386.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 3 November 2017 Resolved
repair/replace flame screen on BD-1
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 23 January 2018
Resolution: Cleared on 1 December by ABS. See report LA3421432-A, item #1387.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 3 November 2017 Resolved
REPAIR/ADJUST ALL SELF CLOSING DOORS TO STAIRWELL TO FULLY CLOSE AND LATCH
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 23 January 2018
Resolution: Cleared on 1 December by ABS. See report LA3421432-A, item #1389.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 3 November 2017 Resolved
Provide CO2 nozzel vic of coffin pump in eng room
Action required: 705 - Other - as specified
Due 4 December 2017
Resolved 23 January 2018
Resolution: Cleared on 1 December by ABS. See report LA3421432-A, item #1390.
Fire Fighting › International Shore Connection › Bolts
Issued 9 December 2016 Resolved
Provide 02 missing bolts, 02 missing nuts, 04 washers, for international shore connection, port side of house structure.
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Above equipment was provided, fixed on the spot.
Lifesaving › Lifebuoys › Serviceable
Issued 9 December 2016 Resolved
Provide new retroreflective tape for indicated lifebuoys on deck.
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Item fixed before end of USCG inspection.
Fire Fighting › Water Fog Applicators › Condition
Issued 9 December 2016 Resolved
Provide new water fog applicator head mounth for applicator aft of house structure; conduct servicing on other applicators on deck to ensure proper head movement.
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Vessel had Spare applicator head on board, and replaced it before we departed
Lifesaving › Launching Appliances › Davit
Issued 9 December 2016 Resolved
Ensure proper operation of forward limit switch, stbd lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 December 2016
Resolution: Limit switch properly rotated, fully operational.
Engineering › Steering Gear System › Pump
Issued 19 August 2016 Resolved
Repair leaks on STBD steering pump.
Action required: 705 - Other - as specified
Due 19 August 2016
Resolved 19 August 2016
Resolution: Vessel crew repaired leaks on steering pump.

Casualty record · 9

26 September 2002Routine · role: Involved in a Marine Casualty · activity 1693849
15 January 2004Routine · role: Subject to Marine Inspection · activity 1986056
2 August 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2740521
22 September 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 3879339
22 April 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3996270
22 March 2012Routine · role: Involved in a Marine Casualty · activity 4273798
14 March 2014Routine · role: Involved in a Marine Casualty · activity 4818688
19 October 2015Routine · role: Involved in a Marine Casualty · activity 5821181
7 January 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5794114
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

CSX ENTERPRISE (2002), HORIZON ENTERPRISE (2004–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.