Records from 1981 to 2001. Most recent: inspection, 17 July 2001.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 84
17 July 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1067085
27 July 2000
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1052562
30 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463547
9 March 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1046999
12 January 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 770231
7 January 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 199103
17 December 1999
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1376004
4 September 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 4850
6 May 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 24630
1 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 59118
1 March 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797824
27 November 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 674749
25 November 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 805864
9 November 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 422497
9 November 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1393020
30 December 1997
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1120877
22 October 1997
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1435999
21 October 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 50551
21 October 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 107981
22 July 1997
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1116185
14 March 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431750
2 August 1996
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 91448
3 May 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 108914
30 April 1996
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1081306
26 April 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 126834
26 April 1996
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1458296
10 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 109439
5 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359017
23 December 1995
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1183921
22 December 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 137397
29 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 469407
16 March 1995
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 826181
4 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 519615
17 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 31766
24 July 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 861202
22 March 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459087
26 January 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 521853
21 November 1993
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 519140
2 September 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 530015
23 July 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 843266
14 April 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 53853
7 April 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1143406
31 March 1993
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1137566
8 December 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 446453
8 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 515848
12 April 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 177645
9 March 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 440216
15 January 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951832
4 October 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 940185
24 July 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 941418
3 May 1991
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 524778
5 February 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302843
30 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 926845
11 January 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1224238
9 January 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1223683
22 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 470008
13 June 1990
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 453381
7 May 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 522908
5 January 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916461
19 May 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199638
9 April 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 491570
4 April 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203734
8 October 1988
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 509192
29 January 1988
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325026
10 September 1987
Permit to Proceed
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008662
20 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1017928
2 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 537667
25 January 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 501305
8 January 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 538412
3 September 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 506995
20 August 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005118
30 April 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 500884
6 March 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995830
16 January 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 486336
21 October 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 538746
13 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980844
7 January 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994501
7 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286285
12 December 1984
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 977462
2 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972454
16 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279105
16 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967594
23 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966079
9 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275482
Construction/Loadline
Issued 9 March 2000
Resolved
crop and renew approximately 30 ft of raised cargo tank top near deck in way of #1 & #2 cargo tanks port side by compliance date or prior to conducting future cargo operations.
Condition: Unknown
Due 9 April 2000
Resolved 24 September 2003
Resolution: COI deactivated.
Construction/Loadline
Issued 9 March 2000
Resolved
crop and renew approximately 25 ft of raised cargo tank top near deck in way of #1 & #2 cargo tanks starboard side prior to compliance date or before conducting future cargo operations.
Condition: Unknown
Due 9 April 2000
Resolved 24 September 2003
Resolution: COI deactivated.
Construction/Loadline
Issued 17 December 1999
Resolved
CROP AND RENEW APPROX. 25 FT OF RAISED CARGO TANK TOP NEAR DECK IN WAY OF #1 AND #2 CARGO TANKS/STBD SIDE.
Condition: Unknown
Due 17 December 1999
Resolved 17 December 1999
Construction/Loadline
Issued 17 December 1999
Resolved
CROP AND RENEW APPROX. 30 FT OF RAISED CARGO TANK TOP NEAR DECK IN WAY OF #1 AND #2 CARGO TANKS/PORT SIDE.
Condition: Unknown
Due 17 December 1999
Resolved 17 December 1999
Documentation
Issued 9 November 1998
Resolved
No record could be found onboard that the Vessel Response Plan approval hadbeen renewed as scheduled.
Condition: Unknown
Due 9 November 1998
Resolved 10 November 1998
Construction/Loadline
Issued 9 November 1998
Resolved
Prove proper operation of all void hatch dogs.
Condition: Unknown
Due 9 November 1998
Resolved 9 November 1998
Construction/Loadline
Issued 9 November 1998
Resolved
Vee out and weld three cracks two feet below deck knuckle IWO collision bulkhead, port side fwd.
Condition: Unknown
Due 9 November 1998
Resolved 9 November 1998
Deck/Cargo
Issued 9 November 1998
Resolved
Prove proper operation of Thermal Fluid Heater.
Condition: Unknown
Due 9 November 1998
Resolved 9 November 1998
Construction/Loadline
Issued 22 October 1997
Resolved
MAINTAIN TEMPORARY REPAIRS TO THE BOTTOM PLATE WITH-IN THE FORWARD RAKE AREA AND PROCEED TO HOUSTON, TEXAS. FOR PERMANENT REPAIRS TO THE FORWARD RAKE, AFT BOX RAKE AND #1 STBD WING VOID.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Electrical
Issued 26 April 1996
Resolved
Install light on the outside thermal fluid heater house red alarm light.
Condition: Unknown
Due 10 May 1996
Resolved 30 April 1996
Unknown
Issued 26 April 1996
Resolved
Thermal fluid heater house, has excessive oil materials, oily rags, oil cans, oil filters, deck slippery. Items to be removed and/or cleaned, priorto using thermal fluid heater.
Condition: Unknown
Due 10 May 1996
Resolved 30 April 1996
Construction/Loadline
Issued 26 April 1996
Resolved
Make permanent repairs to fracture on starboard stern corner at the deck knuckle.
Condition: Unknown
Due 26 May 1996
Resolved 30 April 1996
Electrical
Issued 26 April 1996
Resolved
Install electrical floor matting by all switchboard panesl.
Condition: Unknown
Due 10 May 1996
Resolved 30 April 1996
Unknown
Issued 26 April 1996
Resolved
Clean oil from main deck, underneath cargo pump engine.
Condition: Unknown
Due 10 May 1996
Resolved 30 April 1996
Electrical
Issued 26 April 1996
Resolved
Install electrical blanks as needed on switchboard(s) located on thermal fluid heater house.
Condition: Unknown
Due 10 May 1996
Resolved 30 April 1996
Construction/Loadline
Issued 23 December 1995
Resolved
Prior to loading cargo, effect permanent repairs to hull fractures in stbd nos. 1 & 2 wing void tanks and stern void.
Condition: Unknown
Due 23 December 1995
Resolved 23 December 1995
Deck/Cargo
Issued 31 March 1993
Resolved
MAKE AVAILABLE FOR A USCG MARINE INSPECTOR, AN INTERNAL EXAMINATION OF THE THERMAL FLUID HEATER AND DEMONSTRATE THE PROPER OPERATIONS OF THE THERMAL FLUID HEATER USING USCG APPROVAL TEST PROCEDURES.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Electrical
Issued 11 January 1991
Resolved
OUTLET OUTSIDE THERMAL FLUID ROOM BY ENTRANCE, HAS LOOSE AND OPEN WIRES,_x001C_ ARE REQUIRED TO BE REMOVED OR PROPERLY INSTALLED.
Condition: Unknown
Due 11 January 1991
Resolved 11 January 1991
Electrical
Issued 11 January 1991
Resolved
LIGHT IN THERMAL FLUID HEATER ROOM REQUIRES GUARD.
Condition: Unknown
Due 11 January 1991
Resolved 11 January 1991
Deck/Cargo
Issued 11 January 1991
Resolved
CARGO TRANSFER HOSE REQUIRES TO BE LABELED AS PER 33CFR 154.500
Condition: Unknown
Due 11 January 1991
Resolved 11 January 1991
Electrical
Issued 11 January 1991
Resolved
SWITCHBOARD BOX IN THERMAL FLUID HEATER ROOM REQUIRE BLANKS.
Condition: Unknown
Due 11 January 1991
Resolved 11 January 1991
Deck/Cargo
Issued 20 August 1986
Resolved
OBTAIN AND PLACE ABOARD VSL THE APPROVED OIL TRANSFER PROCEDURES AND THEROMAL FLUID OIL HEATER OPERATION MANUAL.
Condition: Unknown
Due 20 August 1986
Resolved 20 August 1986
Deck/Cargo
Issued 20 August 1986
Resolved
REPAIR OR REPLACE SIGHT GLASS, AS PER ORIGINAL, ON THEROMAL FLUID IN ENTER FLUID EXPANSION TANK.
Condition: Unknown
Due 20 August 1986
Resolved 20 August 1986
Electrical
Issued 20 August 1986
Resolved
INSTALL OCVER ON ELECTRICAL CIRCUIT BREAKER PANEL IN ROLLER RM.
Condition: Unknown
Due 20 August 1986
Resolved 20 August 1986
Unknown
Issued 7 January 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO SFI-31, DN562402
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Unknown
Issued 7 January 1985
Resolved
TEST RELIEF VALVE INSTALLED ON THERMAL FLUID HEATER IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. 46CFR61
Condition: Unknown
Due 7 January 1985
Resolved 7 January 1985
Construction/Loadline
Issued 23 June 1983
Resolved
(REQUIREMENT 1 CONTINUED) AND ARRANGEMENTS MADE TO HAVE THE DAMAGE INSPECT-ED. THIS VESSEL IS TO CARRY NO CARGO UNTIL ALL REPAIRS HAVE BEEN MADE TO
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Construction/Loadline
Issued 23 June 1983
Resolved
(REQUIREMENT 1 CONTINUED) THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL SFI-31, DN562402
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Construction/Loadline
Issued 23 June 1983
Resolved
VESSEL IS TO PROCEED TO NEW ORLEANS, LA., IN AN EMPTY CONDITION. UPON ARRIVAL IN NEW ORLEANS THE OCMI IS TO BE CONTACTED AT NO. [phone withheld]
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983