NAUTICA QUEEN is a 1981 passenger vessel (inspected). The Coast Guard has recorded 116 inspections since 1984, most recently in May 2026, along with 153 deficiencies and 8 casualty investigations between 2005 and 2018.

Records from 1984 to 2026. Most recent: inspection, 28 May 2026.

Built
1981
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP6766
Flag
UNITED STATES
367164090
Maury page id
psix-52563

Inspections, by type

…with no type recorded36
Years with a record 40 calendar years (1984–2026)
The 116 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)102.3 ft × 31.1 ft × 8.9 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEVELAND, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP6766MMSI 367164090 · active · compulsorily equipped · granted 26 June 2024, expires 26 June 2034
WDD5812MMSI 367164090 · cancelled · compulsorily equipped · granted 12 January 2017, cancelled 30 May 2024
WBD5974MMSI not assigned · expired · compulsorily equipped · granted 12 November 1996, cancelled 7 April 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TIKI BARGE I Passenger (Inspected) · MISLE 1609564 · 22 May 2021 · activity 7205588

Inspection history · 116

28 May 2026 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8392727
28 April 2025 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8112985
1 October 2024 MTSA Verification · In-Service Inspection · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8012259
17 July 2024 Deadweight Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7961481
16 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7913311
21 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7828137
4 July 2023 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7733378
10 April 2023 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7667061
9 April 2023 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7679242
5 April 2023 In-Service Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7663068
5 December 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7604268
1 September 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7548706
18 August 2022 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7537490
25 June 2022 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7488933
10 February 2022 Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7394206
11 September 2021 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7311341
18 August 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7291068
22 May 2021 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7205588
16 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7176354
28 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6962637
30 January 2020 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6899243
1 November 2019 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6846916
1 September 2019 Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6803555
16 August 2019 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6785393
4 April 2019 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6655995
4 March 2019 COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6635860
5 December 2018 DAPI Audit
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6597749
8 November 2018 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6577102
7 July 2018 Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6474672
7 June 2018 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6437033
20 May 2018 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6430532
19 May 2018 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6423734
30 April 2018 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6405071
12 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6390389
12 April 2018 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6405043
27 November 2016 Security Breach
Type not classified · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6049830
2 November 2016 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6033798
14 July 2016 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5940307
22 October 2015 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5748366
26 August 2015 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5226855
19 August 2015 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5222351
25 August 2014 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4964862
1 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4193626
20 August 2011 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4125945
22 November 2010 DAPI Audit · Deficiency Check · Annual Inspection · Security Breach
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3896648
18 November 2010 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3894598
18 November 2010 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3894649
20 January 2010 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3666875
16 December 2009 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3651729
23 July 2009 MTSA Verification · Damage Survey · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3554566
20 July 2009 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3540789
20 July 2009 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3541641
24 November 2008 Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3390270
5 October 2008 Administrative Inspection · Excursion Permit
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3330333
27 September 2008 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3340940
30 May 2008 Deficiency Check · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3246016
29 July 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3011360
14 June 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2962155
12 June 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2960038
28 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2950949
25 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2950942
21 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2950931
20 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2946137
17 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2946124
14 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2931911
7 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2925053
4 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2925038
3 May 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2925031
13 April 2007 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2950917
13 March 2007 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2886822
12 June 2006 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2678124
17 August 2005 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2471379
25 July 2005 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2439166
6 July 2005 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2440646
24 May 2005 Annual Inspection · MTSA Verification
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2366750
23 April 2005 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2344925
25 May 2004 Annual Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2077912
21 November 2003 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1961338
10 April 2003 Annual Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1771880
17 October 2002 Drydock Extension
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1694769
21 March 2002 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1493700
19 April 2001 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1063181
26 April 2000 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 817624
23 March 1999 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1437518
13 April 1998 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1462644
10 March 1998 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1386190
25 April 1997 Excursion Permit
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1452275
24 April 1997 Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1409668
14 March 1996 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 885466
7 April 1995 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1166976
9 March 1994 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 853719
24 June 1993 Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 842469
2 April 1993 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 841997
31 March 1993 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1152138
14 January 1993 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1140673
6 August 1992 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 79121
12 May 1992 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 954243
9 April 1992 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1463009
4 February 1992 Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 949305
15 March 1991 Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1221780
26 April 1990 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1235164
30 May 1989 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1341021
26 April 1989 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1206133
15 February 1989 Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1345736
2 February 1989 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1340378
29 April 1988 COI Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1349844
9 April 1987 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1328336
26 March 1987 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1325902
16 April 1986 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1003132
4 April 1986 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1305497
13 August 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 983586
24 July 1985 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 977974
20 July 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1290382
4 May 1985 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 984450
5 April 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1289815
6 November 1984 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1283768

Deficiency record · 153

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 July 2023 Resolved
The owner of a documented vessel must annually renew each endorsement upon the current Certificate (COD) of Documentation for that vessel in accordance with 46 CFR 67.165. Vessel's COD expired in April of 2023. The vessel owner failed to renew the COD, which resulted in the vessel operating on an expired COD. Vessel owner must apply for renewal of COD and provide proof of application to the Coast Guard prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2023
Resolved 7 July 2023
Resolution: Operator/owner provided sufficient evidence for application for COD through NVDC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2023 Resolved
The starboard side-light's lens is melted; displaying an incorrect signal. Replace with appropriate light and lens, prior to operations between sunset and sunrise.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 April 2023
Resolved 5 April 2023
Resolution: Corrected on the spot, deficeincy is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 April 2023 Resolved
Daytime visual distress signals are expired. Replace with appropriate flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 April 2023
Resolved 5 April 2023
Resolution: Corrected on the spot. The deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023 Resolved
Prove compliance with Drug & Alcohol Programs, per 46CFR16, by completing a successful DAPI Audit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 28 April 2023
Resolution: Completed Chemical Testing Program Compliance Audit. Deficiency was cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023 Resolved
Review compliance with security program requirements IAW 33CFR104, to include updated drills and exercises.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 28 April 2023
Resolution: The vessel is enrolled in and implementing the PVA, Alternative Security Plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 December 2022 Resolved
The 110v distribution pannel emergency cut off breaker is faulty. Prove proper operation of said breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2022
Resolved 6 December 2022
Resolution: Breaker renewed ested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's main engine is overheating due to an anti-freeze leak. Vessel is make permanent repairs to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2022
Resolved 23 August 2022
Resolution: New gasket was put on the engine block and the MDE was run at operating temperature, with no leaks noted. The deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 March 2022 Resolved
The float light on the Type IV, ring buoy, needs an approved battery.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 13 April 2022
Resolution: New floatlight w/appropriate battery has been attached to the life-float. Defeciency is cleared.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2022 Resolved
Mark the escape route via the doors on the second deck after bulkhead with EXIT signs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 13 April 2022
Resolution: Proper markings are in place. Defeciency was cleared.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 March 2022 Resolved
Charts must be updated for the operating area.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 13 April 2022
Resolution: Updated navigational charts are onboard and available. Defeciency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 February 2022 Resolved
Transvers frame is wated in the portside void, adjacent to the forward head. Crop and renew to good steel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 21 March 2022
Resolution: The area of concern was satisfactorily renewed and the deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2021 Resolved
Port ship service diesel generator (SSDG) overheated, and shut down. Prove proper operation of two SSDG IAW §120.310, prior to carrying passengers for hire.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2021
Resolved 15 September 2021
Resolution: Renewed the water pump and thermostats, test ran for 2 hours underload, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2021 Resolved
COI allows 389 total persons on board. There are only 274 adult sized life preservers, so the total persons allowed on board is now limited to 274, until an appropriate number of approved life preservers are procured and in place.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 13 April 2022
Resolution: An additional 95 Type I PFDs were added to the 274 acceptable PFDs that were onboard. Defeciency is cleared, and allowable passenger count is IAW COI.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 16 April 2021 Resolved
Corrosion is evident on the superstructure's exterior bulkhead, on the starboard side/aft, where the second deck meets the overhead of the first deck. Crop and renew to good metal.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 19 May 2021
Resolution: Inspected repairs and found them to be satisfactory. Deficiency is cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 16 April 2021 Resolved
Replace broken window on the starboard side aft, in the bar area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 16 June 2021
Resolution: Window was replaced and the deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2021 Resolved
Rewrite the vessel's Station Bill, IAW §122.514. Remove persons not elligible for safety sensative positions, due to non-participation in chemical testing programs IAW §16.201. Ensure posted bills are the same throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 16 June 2021
Resolution: The company rewrote the vessel's Station Bill, which delineates crew responsibilities during emergencies. Deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2020 Resolved
COI requires 398 Adult Life Jackets and the vessel has only 328 serviceable Adult Life Jackets on-board. Total persons on-board is limited to 328 until sufficient replacements are procured.
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 17 June 2021
Resolution: Serviceable adult life jackets on board is now only 274. Reduced total persons allowed on board to 274 until sufficient replacements are procured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2020 Resolved
Due to the number of outstanding worklist items, caused by the pandemic shut-down; the vessel must complete a satisfactory follow up inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 16 June 2021
Resolution: Satisfactory Annual Inspection completed and the deficiency was cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 December 2019 Resolved
Vessel has not satisfactorily completed Drydock and ISE exam. Credit has been temporarily granted to accomidate vessels schedule for 02 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2019
Resolved 31 December 2019
Resolution: The vessel received credit for a satisfactory dry dock and internal structural examinations. Deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Main deck secured to all passengers and non-essential crew. Galley secured until further notice.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Restricted to River route only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: Restriction removed; the vessel may operate within the constraints of the Routes and Conditions noted on their COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Vessel to suspend all passenger operations on 15DECEMBER2019 until satisfactory completion of drydock exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: The suspention of passenger operations is lifted in light of the completion of a successful, Dry Dock examination. The vessel may operate within the constraints of their COI.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 1 November 2019 Resolved
The collision blkhd has wastage clear across the bottom of the up from the deck 6-8"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Repairs to wastage noted on the collision bulkhead has been satisfactorily repaired. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2019 Resolved
The deck of the forward lower head(s) is also the top of the sewage tank and is showing severe wastage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Wasted areas on the sewage holding tank have been renewed and the tank is fit for its intended use. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019 Resolved
Port side outboard of the lower head has 3 wasted frames as well as the longitudinal frame in the same area is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Wasted areas have been renewed and the deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2019 Resolved
Bilge suction line in the port side of the galley is broken. (it's not for the galley bilge suction it's just located in there)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: The bilge suction line was satisfactorily repaired and the deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019 Resolved
Several (at least least 8) frames in the galley are wasted. Crop and renew
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Frames renewed as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019 Resolved
The keel cooler, aft of the STBD MDE is leaking into the E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2019
Resolution: Renewed as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019 Resolved
Keel cooler purge valves in the Lazzerette are broke off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Resolved as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 September 2019 Resolved
Starboard SSDG suffered a failure of the front seal, resulting in a loss of lube oil.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2019
Resolved 4 September 2019
Resolution: Generator was tested under load and all tests were satisfactory. Deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2019 Resolved
STBD generator will nnot start.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2019
Resolved 17 August 2019
Resolution: Repairs complete. New blower and injectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2019 Resolved
Replace personal floatation devices that were deteriorated and those that were missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Company purchased (95) replacement Type I PFDs and put on station. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 March 2019 Resolved
Last drill recorded was in March 2018. Conduct drills prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Emergency drills were conducted to the satisfaction of CG MIs. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 March 2019 Resolved
Prove proper operation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Fire pump is in operational condition. Deficiency was cleared.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2019 Resolved
Updated charts for the operating area must be onboard prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Updated charts are onboard. Deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2019 Resolved
Conduct required security drills and exercises in accordance with 33CFR104.230, and document/record completion of same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2019
Resolved 4 April 2019
Resolution: Drill and excercise completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2018 Resolved
The company does not have a DOT Drug Testing Program for employees that are serving in a safety sensitive position. Fully implement a DOT Drug Testing Program and pass a U.S. Coast Guard DAPI Audit within 60 days.
Action required: 10 - Deficiency Rectified
Due 4 February 2019
Resolved 3 April 2019
Resolution: Company established a DOT Drug Testing Program; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2018 Resolved
Re-label power panels throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 14 March 2019
Resolution: Panels are correctly labeled. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 November 2018 Resolved
Crop and renew wasted steel frame in the forward, lower, port head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 14 March 2019
Resolution: Wasted area renewed to good steel. Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
Conduct DAPI Audit w/CG by 12/15/2019.
Action required: 705 - Other - as specified
Due 15 December 2018
Resolved 3 April 2019
Resolution: IO completed audit, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2018 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be effectively insulted. The port main engine exhuast piping at the exhaust manifold in not insulated or water cooled. Properly insulate the exposed exhaust piping within 7 days IAW 46 CFR 180.20-15 and 182.15-15(b).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2018
Resolved 20 July 2018
Resolution: Renewed the affected piece of lagging, all sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 May 2018 Resolved
Missing port propeller.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2018
Resolved 25 May 2018
Resolution: Propeller replaced with brace welded to shaft to prevent loss.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 30 April 2018 Resolved
AIS transponder must be activated while the vessel is underway.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 30 April 2018
Resolved 1 May 2018
Resolution: AIS transponder is operational. Deficiency cleared.
Construction/Loadline › Structures › Superstructure
Issued 20 April 2018 Resolved
Crop and renew wasted area on superstructure just forward of the access door on the starboard quarter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 8 May 2018
Resolution: Wasted area was copped out and new steel installed. Deficiency was cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2018 Resolved
Starboard generator has an exhaust leak on piping.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 8 May 2018
Resolution: Exhaust pipe repaired. No exhaust leak and deficiency was cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2018 Resolved
There is an anti-freeze leak on pipe going from the generator to the keel-cooler.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 8 May 2018
Resolution: Flange gasket was replaced and leak repaired. Deficiency was cleared.
Fire Fighting › Fire Pumps › Bearings
Issued 12 April 2018 Resolved
Fire pump, driven off of the port MDE, is not creating adequate pressure to supply hoses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2018
Resolved 13 April 2018
Resolution: Ship's crew found impellor blade lodged in pipe. Debris removed and system operated satisfactorily when tested. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 April 2018 Resolved
Lable breakers on auxiliary galley, panelboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: Panel properly labled. Deficiency cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 April 2018 Resolved
Secure mounting bracket of B-II extinguisher in Main Deck Food Service Area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: Bracket firmly attached. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 April 2018 Resolved
Secure floor matting on deck in the Main Deck Food Service Area. Matt is currently a tripping hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Flooring was relaid, and mat now lays flat. Deficiency cleared.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2018 Resolved
Lights in the aft bar/food prep area must have covers installed over bulbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: New covers were installed. Deficiency cleared.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 April 2018 Resolved
Fixture in the galley is currently in place with "zip-ties" and must be permanently installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Light fixture was permanently attached to the overhead. Deficiency was cleared.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 April 2018 Resolved
Receptical on aft bulkhead of the engine room is missing a cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Receptical was replaced and the deficiency was cleared.
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2018 Resolved
Cover is missing for pig-tail aboard the vessel that attaches to shore-tie cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 November 2018
Resolution: Satisfactory cover in place on shore-tie cable. Deficiancy cleared.
Construction/Loadline › Structures › Door
Issued 12 April 2018 Resolved
Access door on the port quarter has extensive wastage along the bottom and sides of the door. Must be renewed to good steel or replaced altogether.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 8 May 2018
Resolution: Wasted area was cropped out and new steel welded in place. Deficiency was cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 April 2018 Resolved
Crop and renew the bottom three (3) stairs heading down to the galley, which are wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 7 June 2018
Resolution: Wasted stairs were removed and replaced to the satisfaction of marine inspectors. Deficiency is cleared.
Accommodation/Occupational Safety › Messroom › Location
Issued 2 November 2016 Resolved
Sanitize the galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 5 November 2016
Resolution: The cleanliness of the galley is markedly improved. Deficiency was removed.
Accommodation/Occupational Safety › Messroom › Location
Issued 2 November 2016 Resolved
Have galley/food prep area inspected by local heath/food service inspector. Coast Guard to attend inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2016
Resolved 12 April 2018
Resolution: Vessel produced satisfactory inspection form from City Health Inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016 Resolved
Repair oil leaks on Port SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 12 April 2018
Resolution: Inspected generator after operation and found to be is satisfactory condition. Deficiency cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016 Resolved
Prove proper operation of starboard SSDG, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 5 November 2016
Resolution: Starboard generator was operated satisfactorily and the deficiency removed.
Engineering › Steering Gear System › Cable
Issued 14 July 2016 Resolved
Cable parted. No indication of binding or wear, cable is to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2016
Resolved 22 July 2016
Resolution: Conducted a satisfactory full range of motion test of the ship's steering system. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 October 2015 Resolved
Replace worn wires and connections on hot plate in the galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 October 2015
Resolution: Electrician replaced wires and reattached to hot plate. Deficiency cleared.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 October 2015 Resolved
Replace worn wiring on overhead light fixture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 23 October 2015
Resolution: Electrician replaced wiring assembly on light fixture on overhead light in the galley.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 October 2015 Resolved
Remove dead-end wires and replace worn wires in galley electrical panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2015
Resolved 23 October 2015
Resolution: Panel wiring repaired. Deficiency cleared.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 22 October 2015 Resolved
Prove proper operation of self-closing doors in the galley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2015
Resolution: Ship's company adjusted door to facilitate proper operation. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 August 2014 Resolved
Install cover onto electrical receptacle by the port bow
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 7 October 2014
Resolution: Proper cover is installed and functional. Deficiency is cleared.
Engineering › Fuel Oil Service System › Filter
Issued 25 August 2014 Resolved
Replace non-metallic fuel bowls on fuel filters w/metallic type.
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 7 October 2014
Resolution: Appropriate bowls are installed on MDE fuel filters. Deficiency is cleared.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 25 August 2014 Resolved
Secure toilet to the deck.
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 7 October 2014
Resolution: Toilets secured. Deficiency cleared.
Accommodation/Occupational Safety › Ventilation › General
Issued 25 August 2014 Resolved
Clean dust from and attach screen to protect persons from fan blades.
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 7 October 2014
Resolution: Found ventilation fans to be in satisfactory condition. Deficiency is cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 August 2014 Resolved
Replace mounting bracket for fire extinguisher on the bridge.
Action required: 705 - Other - as specified
Due 25 September 2014
Resolved 7 October 2014
Resolution: Fire extinguisher mounting bracket is securely fastened on the bridge. Deficiency is cleared.
Stability › Incline Test › General
Issued 1 December 2011 Resolved
Issued a CG-835 requiring the vessel to conform to listed passenger load limits until they receive an amended stability letter from CG Marine Safety Center.
Action required: 705 - Other - as specified
Resolved 16 December 2011
Resolution: MSC issued a revised stability letter for the NAUTICA QUEEN using the new AAWPP of 185 lbs and the weight ration method to calculate the vessel''s passenger carrying capacity.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 November 2010 Resolved
Replace light globes on forward deck and galley lights.
Condition: Improper/Lack of Maintenance
Due 3 December 2010
Resolved 1 December 2010
Resolution: Appropriate globes were installed on the light fixtures identified during the annual inspection. Deficiency cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 22 November 2010 Resolved
Adjust bracket for B-II fire extinguisher in the galley.
Condition: Improper/Lack of Maintenance
Due 3 December 2010
Resolved 1 December 2010
Resolution: The fire extinguisher bracket functions as intended. Deficiency cleared.
Fire Fighting › Grease Extraction Hood › General
Issued 22 November 2010 Resolved
Clean exhaust vent above the cooking area.
Condition: Improper/Lack of Maintenance
Due 3 December 2010
Resolved 1 December 2010
Resolution: Exhaust vent above the cooking area is satisfactorily cleaned. Deficiency cleared.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 22 November 2010 Resolved
Replace wire nuts on Starboard MDE with appropriate fasteners.
Due 3 December 2010
Resolved 1 December 2010
Resolution: Wires on the starboard MDE are fitted w/appropriate fasteners. Deficiency cleared.
Accommodation/Occupational Safety › Messroom › Location
Issued 22 November 2010 Resolved
Reconfigure hatch on the grey water tank so that it seals.
Condition: Improper Installation
Due 15 March 2011
Resolved 23 March 2011
Resolution: Gray water tank hatch bolted shut.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 18 November 2010 Resolved
Starboard ship's service generator experienced an automatic shut-down while underway. Required to prove proper operation prior to carrying passengers while underway. NAUTICA QUEEN may embark passengers if the vessel remains moored to the pier and has an additional crew member assigned as a roving fire watch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2010
Resolved 20 November 2010
Resolution: Received technician''''s report, "Downloaded new payload for ECU & reflashed the controller. Ran good and the load percentages matched the generator".Generator ran under various loads w/o dropping off-line for CG Marine Inspector. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 January 2010 Resolved
Replace protective cover on electrical switchboard panel in engine room to prevent accidental electrocution of persons in that space, no later than 01FEB2010.
Condition: Improper Installation
Due 1 February 2010
Resolved 25 January 2010
Resolution: Protective cover installed on switchboard panel to the satisfaction of the marine inspector. Cleared deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 20 January 2010 Resolved
During deficiency check, noted oil splattered on engine room overhead above port side ship's service generator. Prove proper operation of ship service generator (port side) prior to sailing.
Condition: Improper/Lack of Maintenance
Due 1 February 2010
Resolved 1 April 2010
Resolution: Cleared deficiency today after witnessing proper operation of the port side ship''s service generator.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 December 2009 Resolved
Observed cracks in retaining ring that holds cable end cover to the cable. Replace cracked retaining ring to the satisfaction of Coast Guard Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2010
Resolved 20 January 2010
Resolution: Shore side electrical supply cable connection was replaced in its entirety to correct this deficiency. Cleared deficiency on this date 20JAN2010.
Engineering › Fuel Oil Service System › Piping
Issued 30 July 2009 Resolved
In cases where flexible fuel piping exceeds the 30" maximum allowable length, replace the existing flexible fuel lines with the prescribed combination of metal (see 46CFR119.455(a) for specifications) and SAE J-1402 flexible hose. All existing flexible hoses of any length must meet the SAE J-1942 standard or be replaced with hoses meeting this standard.
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified all flex hoses are less than 30" and meet J-1492.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 July 2009 Resolved
COD expired 31JUL09
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Valid COD on board. Issued 18 Jun 09 Expires 31July 10.
Personnel › Training › First Aid/CPR
Issued 23 July 2009 Resolved
Of the 7 total crewmembers onboard, 4 must be current in their first aid & CPR training. Thus far, only 1 crewmember has presented evidence of currency.
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Rcvd copy of invoice for CPR training for 9 of 10 employees.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 23 July 2009 Resolved
Vessel has not submitted annual MIS report to CGHQ.
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: MIS report MAILED to CG HQ. Copy of report and envelope are in case file.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 July 2009 Resolved
Permanently re-install wiring in operator's console which is preventing compass from illuminating.
Action required: 705 - Other - as specified
Resolved 30 August 2009
Resolution: Witnessed operation.
Operations/Management › Passenger Operations › Safety Orientation
Issued 23 July 2009 Resolved
Modify passenger safety orientation so that it very clearly covers the topics prescribed in the regulations.
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: Attended to vessel to review the passenger safety orientaion script they will use to meet the requirements of 46CFR122.506. Cleared deficiency after reviewing their script.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 23 July 2009 Resolved
Post Fire Control Plan onboard vessel.
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: Attended vessel to ensure corrections to the fire control plan are IAW 46CFR116.530. Fire control plan is satisfactory, deficiency cleared.
Navigation › Piloting/Steering › Marine Charts
Issued 23 July 2009 Resolved
Provide corrected charts for area of operation.
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Verified corrected charts are on board for vessels intended route.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 July 2009 Resolved
Remove/replace expired medicines in first aid kits.
Action required: 705 - Other - as specified
Resolved 24 August 2009
Resolution: Verified medicines in first aid kit have been replaced.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 23 July 2009 Resolved
Repair gauges to indicate engine revolutions per minute, jacket water discharge temperature and lubricating oil pressure for each installed propulsion engine in accordance with 46CFR119.410. Gauges must be visible at the operating station.
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: Attended vessel, all gauges required by 46CFR119.410 function properly and are visible from the operating station. Cleared deficiency.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 July 2009 Resolved
Jacket water hoses require double clamps on each end.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified double clamps on all hoses.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 23 July 2009 Resolved
Fuel vent pipes do not have the required 30 x 30 screens installed. Replace existing screens with those required by 46CFR119.450.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Attended to vessel and cleared the deficiency. 30 x 30 screen installed in conformance with 46CFR119.450.
Electrical › Electric Supply System (service) › Cable
Issued 23 July 2009 Resolved
Replace shore-tie cable. Current cable is kinked and the outer protective jacket is chaffed through causing an electrocution hazard. Chaffed shore-tie cable must immediately be taken out of service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: Attended vessel to inspect shore-tie cable. Shore-tie cable was removed from the vessel and the shore-tie receptacle box is blanked off. Deficiency cleared.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 23 July 2009 Resolved
Submit drawing of the Gray Water System to the Coast Guard Marine Safety Center for approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 2 September 2009
Resolution: Attended vessel to inspect grey water system. Drawings were received by Coast Guard Marine Safety Center and system conforms with the drawing and regulations. Deficiency cleared.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 23 July 2009 Resolved
Install 30 x 30 mesh screening on the vent pipe leading to the marine sanitation device to prevent the possibility of an explosion.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Attended to vessel, deficiency cleared. 30 x 30 mesh screen is in place in compliance with 33CFR159.95.
Engineering › Bilge Water Management System › Pump
Issued 23 July 2009 Resolved
Repair or replace bilge switch in the lazarette, galley, and starboard void. Prove proper operation of all installed bilge switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified proper operation of bilge alarm switchs.
Engineering › Bilge Water Management System › Pump
Issued 23 July 2009 Resolved
Prove proper operation of the visual and audible high water alarms located at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Witnessed high water alarms at operating station are operable. Buzzer has been repaired.
Electrical › Electric Generation Source (service) › Panelboard
Issued 23 July 2009 Resolved
The switchboard for the ship's service generator allows shore power and the generator to feed the electrical system at the same time. Install physical barrier that prevents both shore side and ship board electrical sources from being on-line at the same time.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: Attended vessel to inspect interlocking mechanism on the electrical system. The newly installed [name withheld] system prevents the generators from being simultaneously connected to the switchboard IAW 46CFR120.332 (b). Deficiency cleared.
Engineering › Compressed Air System (control) › Compressor
Issued 23 July 2009 Resolved
Repair or replace limit switch on the compressor and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Witnessed proper operation of compressor cut out switch.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 23 July 2009 Resolved
Replace dead batteries on the starboard side of the engine room. Prove proper operation of the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified new batteries are installed for the STBD 32 volt bank.
Electrical › Electrical Distribution System (emergency) › Conductor
Issued 23 July 2009 Resolved
There is a washer jammed into the 12 volt power supply box to facilitate operation. This presents an electrical hazard and must be repaired or replaced. Upon repair, prove proper operation of the unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified the 12 volt selector box has been repaired.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 23 July 2009 Resolved
Repair or replace 12 volt battery charger and prove proper operation of the same.
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified 12 volt charger has been replaced by a LaMarch marine 12 volt charger.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 23 July 2009 Resolved
Unable to switch from Port battery bank to the Starboard battery bank. Repair or replace the control box and prove proper operation of the same.
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified the 32 volt selector box ha been repaired.
Construction/Loadline › Structures › Deck Plating
Issued 23 July 2009 Resolved
Produce documentation showing U.S. Coast Guard approval for the hole that was cut in the main deck to facilitate replacement of the generator set or return to original condition.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Main deck has been returned to original condition. This was accomplished by welding new plate IAW NVIC 7-68 utilizing a backing plate.
Electrical › Electric Supply System (service) › Cable
Issued 23 July 2009 Resolved
Remove permenantly installed electrical extention cord from overhead in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 July 2009 Resolved
Replace bulb or repair fixture and prove proper operation of service lighting in the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Verified lights in Laz are operable.
Electrical › Electrical Distribution System (service) › Cable
Issued 23 July 2009 Resolved
Remove unused electrical wire in overhead on the main deck, forward, starboard bow area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: Verified removed.
Construction/Loadline › Penetrations › Gasket
Issued 23 July 2009 Resolved
Remove unused pipe that traverses from the lazarette to the engine room (penetrating 3 spaces) and repack stuffing tubes to make watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Verified pipe has been removed and void has been packed.
Construction/Loadline › Structures › Deck Plating
Issued 23 July 2009 Resolved
Crop out and renew to good metal, as original, the vent pipe (starboard side) and wasted metal in the area surrounding the vent pipe on the deck in the bow ramp space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2009
Resolution: Attended vessel on 14AUG2009 to inspect repair of vent piping in bow ramp space. New pipe and metal plate installed to the satisfaction of marine inspector. Deficiency cleared. N.J. Suvak
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 23 July 2009 Resolved
Submit drawings of the current engine room general equipment arrangement plan and drawings of the existing electrical system.
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: Verified receipt of drawing w/ the Coast Guard Marine Safety Center. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 July 2009 Resolved
Submit for approval drawings of the proposed electrical system's generators and switchboard arrangement.
Action required: 705 - Other - as specified
Resolved 23 July 2010
Resolution: Deficiency cleared due to vessel continuing to delay plans to update electrical arrangement as a result of economical concerns. Vessel HAS NOT submitted electrical plans to MSC.
Fire Fighting › Means of Escape › Doorways
Issued 23 July 2009 Resolved
Currently the door on the forward, port side, second deck is missing a door knob and remains locked. Install a new door knob and leave door unlocked when persons are on board the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 August 2009
Resolution: New knob has been installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 23 July 2009 Resolved
Provide a second means of controlling the Port main diesel engine to conform with the requirements of 46CFR121.620.
Action required: 705 - Other - as specified
Resolved 28 August 2009
Resolution: Attended to vessel to inspected newly installed quick disconnect linkage. New linkage meets the requirements of 46CFR121.620, deficiency cleared.
Electrical › Electric Supply System (service) › Battery Charger
Issued 23 July 2009 Resolved
Unable to verify 12 volt wiring is approved for marine use. Prove wiring is in compliance with 46 CFR 120.340 or 46 CFR 111.60-1 or replace with wire that is.
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: Attended vessel to confirm cable used on the battery charger is marine grade and in compliance w/46CFR120.340 or 46CFR111.60-1. Installed cable is IEEE45 approved marine shipboard cable. Cleared deficiency.
Electrical › Electric Generation Source (service) › Generator
Issued 20 July 2009 Resolved
Attended vessel to clear existing deficiencies when we noticed oil on the area surrounding the service generator. Upon further inspection we noticed a wire was being used to by-pass the generator's designed safety mechanisms by forcing the shut-down device in the open position preventing it from operating as designed. Ship must prove proper operation of ship service generator prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2009
Resolution: Attended vessel w/[name withheld] and [name withheld] Inspected the newly installed ship''''''''s service generator to ensure proper operation of the same. All tests are satisfactory. Cleared deficiency #17. N.J. Suvak
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 20 July 2009 Resolved
Due to an oil leak at the service generator's seal, there is an excessive accumulation of oil in the bilge, soaked into insulation, and dried onto the bulkheads near the generator, as well as the generator itself. Ship's force must eliminate the unsafe condition related to the oil leak by removing and replacing oil soaked insulation and removing oil from the bilge and other surfaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2009
Resolution: Attended vessel w/[name withheld] to inspect spaces for hazards. Engine room is free of fire hazards and excess oil has been removed from the space and all surfaces cleaned of standing oil. Cleared deficiency #18. N.J. Suvak
Lifesaving › Hand Flares › Expired
Issued 30 May 2008 Resolved
Replace expire flares on vessel with 12 new flares.
Due 30 May 2008
Resolved 30 May 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2008 Resolved
Replace expired medication in first aid kit
Due 30 May 2008
Resolved 30 May 2008
Personnel › Training › First Aid/CPR
Issued 30 May 2008 Resolved
Ensure 50% of the crew is first aid/CPR qualified
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 21 July 2008
Resolution: Master provided documentation showing at least 50% of crew is current on CPR/first aid certification.
Personnel › Certificates/Documents/Licenses › Motorboat Operator's License
Issued 30 May 2008 Resolved
Provide Marine Radio Operator Permit for [name withheld]
Action required: 705 - Other - as specified
Due 14 July 2008
Resolved 21 July 2008
Resolution: Master provided interim proof of having passed the radio operator test and is currently awaiting receipt of his operator''s permit.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 30 May 2008 Resolved
Log all equipment tested in vessel's logbook.
Due 30 June 2008
Resolved 21 July 2008
Resolution: Logs provided.
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 May 2008 Resolved
Calibrate compass
Action required: 705 - Other - as specified
Due 14 July 2008
Resolved 14 July 2008
Resolution: Compass is calibrated. Deficiency cleared.
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2008 Resolved
Provide updated charts on vessel.
Due 6 June 2008
Resolved 30 June 2008
Resolution: Updated charts provided for [name withheld] and Cuyahoga River.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 May 2008 Resolved
Provide donning placard for additional type of PFD's aboard vessel.
Due 30 June 2008
Resolved 30 June 2008
Resolution: Additional type life jacket placards posted on main and second decks next to fire stations and emergency instructions.
Communications › Public Address System › Announcing Station
Issued 30 May 2008 Resolved
Remove or repair Loud hailer system in pilothouse.
Due 30 June 2008
Resolved 21 July 2008
Resolution: Received tech report indicating the loud hailer has been repaired.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 30 May 2008 Resolved
Repair short in echo depth sounder.
Action required: 705 - Other - as specified
Due 14 July 2008
Resolved 18 July 2008
Resolution: Deficiency voided. Per 33CFR164, vsl is not required to carry onboard an echo depth sounder.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 May 2008 Resolved
Provide proof of enrollment in drug and alcohol testing program.
Due 30 June 2008
Resolved 23 June 2008
Construction/Loadline › Structures › Deck Plating
Issued 30 May 2008 Resolved
Replace or repair deck plating in galley.
Due 30 June 2008
Resolved 30 June 2008
Resolution: Deck plating in galley secured.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 May 2008 Resolved
Label all emergency lighting.
Due 30 June 2008
Resolved 30 June 2008
Resolution: All emergency lighting properly labeled and marked as red with a block "E".
Electrical › Lighting (service) › Lighting Fixture
Issued 30 May 2008 Resolved
Replace cracked and missing light covers.
Due 15 July 2008
Resolved 30 June 2008
Resolution: Broken light covers replaced/ordered.
Engineering › Bilge Water Management System › Manifold
Issued 30 May 2008 Resolved
Replace missing labels on bilge manifold.
Due 30 June 2008
Resolved 30 June 2008
Resolution: Missing labels on bilge manifold identified and replaced effectively.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 March 2007 Resolved
Port side galley fire door does not close completely. Cause is the closure device/arm. Closure device needs to be replaced in order for fire door to close completely.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 19 April 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 13 March 2007 Resolved
Starboard side diesel generator missing exhaust manifold lagging/insulation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 19 April 2007
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 13 March 2007 Resolved
Audible bilge alarm on bridge not working properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 19 April 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 March 2007 Resolved
Vessel to conduct man-overboard drill.
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 19 April 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 13 March 2007 Resolved
Replace cover on switchboard (on the old Buss Tie)
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 19 April 2007
Construction/Loadline › Structures › Superstructure
Issued 13 March 2007 Resolved
Install rail courses on upper deck IAW 46 CFR 116.900(f)
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 30 May 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 May 2005 Resolved
Repair galley fire doors, did not close properly when pin was pulled.
Due 7 June 2005
Resolved 30 June 2005
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 21 November 2003 Resolved
Make proper repairs to starboard propeller.
Due 2 December 2003
Resolved 2 December 2003
Fire Fighting › Nozzles
Issued 10 April 2003 Resolved
Replace straight stream nozzles with variable nozzels. LEGACY COMPONENT DESC: Type
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 10 April 2003
Resolution: Vessel purchased nozzels.
Construction/Loadline › Structures
Issued 10 April 2003 Resolved
Repair water tank and bulkhead damaged by freezing during winter lay-up. Repairs to be completed during next drydock. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 25 May 2004
Resolution: Replaced existing steel tank with three plastic tanks 400 gals each, total of 1200 gals potable water capacity, increase of 200 gals, weight of water increase offset by replacing steel with plastic tanks. Inspection satisfactory.
Electrical
Issued 2 April 1993 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP/SHUTDOWN ON STBD ENGINE ROOM GENERATOR.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Lifesaving
Issued 2 April 1993 Resolved
PROVIDE 63 ADDITIONAL ADULT LIFE PRESERVERS FOR A TOTAL OF 450. VESSEL IS RESTRICTED TO THE CARRAGE OF 387 TOTAL PERSONS UNTIL PRESERVERS ARE PROVIDED AND INSPECTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Construction/Loadline
Issued 2 April 1993 Resolved
REPAINT MISSING 7 FOOT DRAFT MARK ON FWD/STBD HULL.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Electrical
Issued 2 April 1993 Resolved
REMOVE NON-WATERTIGHT DRESS LIGHTS ON WEATHER DECK.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 14 January 1993 Resolved
TIGHTEN BOTH PORT AND STBD RUDDERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1993
Resolved 25 March 1993
Navigation
Issued 14 January 1993 Resolved
COTTER KEY, DOUBLE NUT OR LOCK NUT ALL MECHANICAL STEERING LINKAGE CONNECTIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1993
Resolved 25 March 1993
Engineering
Issued 14 January 1993 Resolved
REPLACE PORT SHAFT CUTLESS BEARINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1993
Resolved 25 March 1993
Engineering
Issued 26 April 1989 Resolved
INSTALL IN PILOT HOUSE LUBE OIL PRESSURE AND COOLING WATER DISCHARGE TEMP. GAGES FOR BOTH MAIN ENGINES.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Electrical
Issued 26 March 1987 Resolved
PROVE SATISFACTORY OPERATION OF PORT GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Lifesaving
Issued 26 March 1987 Resolved
REPLACE MISSING BUOYANT APPARATUS.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 4 April 1986 Resolved
MAKE MODIFICATIONS TO BOW FREEING PORTS TO ALLOW EASY OPERATION.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 20 July 1985 Resolved
PASSENGERS ARE REDUCED TO 56 CHILDREN UNTIL ADDITIONAL PFD'S ARE PLACED ONBOARD AND VIEWED BY USCG INSPECTOR. NO CHANGE TO TOTAL PASSENGERS MADE ATTHIS TIME.
Condition: Unknown
Due 20 July 1985
Resolved 20 July 1985

Casualty record · 8

6 July 2005Routine · role: Involved in a Marine Casualty · activity 2440646
27 September 2008Routine · role: Involved in a Marine Casualty · activity 3340940
20 July 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3541641
23 April 2010Routine · role: Involved in a Marine Casualty · activity 3726282
18 August 2010Routine · role: Involved in a Marine Casualty · activity 3828128
18 November 2010Routine · role: Involved in a Marine Casualty · activity 3894598
20 August 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4125945
20 May 2018Routine · role: Involved in a Marine Casualty · activity 6430532
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.