Records from 2005 to 2026. Most recent: inspection, 28 May 2026.
Inspection history · 38
28 May 2026
Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8392727
28 April 2025
MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8112985
1 October 2024
MTSA Verification · In-Service Inspection · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8012259
17 July 2024
Deadweight Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7961481
16 May 2024
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7913311
21 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7828137
4 July 2023
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7733378
10 April 2023
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7667061
9 April 2023
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7679242
5 April 2023
In-Service Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7663068
5 December 2022
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7604268
1 September 2022
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7548706
18 August 2022
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7537490
25 June 2022
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7488933
10 February 2022
Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7394206
11 September 2021
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7311341
18 August 2021
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7291068
22 May 2021
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7205588
16 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7176354
28 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6962637
30 January 2020
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6899243
1 November 2019
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6846916
1 September 2019
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6803555
16 August 2019
In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6785393
4 April 2019
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6655995
4 March 2019
COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6635860
5 December 2018
DAPI Audit
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6597749
8 November 2018
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6577102
7 July 2018
Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6474672
7 June 2018
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6437033
20 May 2018
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6430532
19 May 2018
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6423734
30 April 2018
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6405071
12 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6390389
12 April 2018
Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6405043
27 November 2016
Security Breach
Type not classified · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6049830
2 November 2016
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6033798
14 July 2016
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5940307
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 July 2023
Resolved
The owner of a documented vessel must annually renew each endorsement upon the current Certificate (COD) of Documentation for that vessel in accordance with 46 CFR 67.165. Vessel's COD expired in April of 2023. The vessel owner failed to renew the COD, which resulted in the vessel operating on an expired COD. Vessel owner must apply for renewal of COD and provide proof of application to the Coast Guard prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2023
Resolved 7 July 2023
Resolution: Operator/owner provided sufficient evidence for application for COD through NVDC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2023
Resolved
The starboard side-light's lens is melted; displaying an incorrect signal. Replace with appropriate light and lens, prior to operations between sunset and sunrise.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 April 2023
Resolved 5 April 2023
Resolution: Corrected on the spot, deficeincy is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 April 2023
Resolved
Daytime visual distress signals are expired. Replace with appropriate flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 April 2023
Resolved 5 April 2023
Resolution: Corrected on the spot. The deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023
Resolved
Prove compliance with Drug & Alcohol Programs, per 46CFR16, by completing a successful DAPI Audit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 28 April 2023
Resolution: Completed Chemical Testing Program Compliance Audit. Deficiency was cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023
Resolved
Review compliance with security program requirements IAW 33CFR104, to include updated drills and exercises.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 28 April 2023
Resolution: The vessel is enrolled in and implementing the PVA, Alternative Security Plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 December 2022
Resolved
The 110v distribution pannel emergency cut off breaker is faulty. Prove proper operation of said breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2022
Resolved 6 December 2022
Resolution: Breaker renewed ested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's main engine is overheating due to an anti-freeze leak. Vessel is make permanent repairs to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2022
Resolved 23 August 2022
Resolution: New gasket was put on the engine block and the MDE was run at operating temperature, with no leaks noted. The deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 March 2022
Resolved
The float light on the Type IV, ring buoy, needs an approved battery.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 13 April 2022
Resolution: New floatlight w/appropriate battery has been attached to the life-float. Defeciency is cleared.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2022
Resolved
Mark the escape route via the doors on the second deck after bulkhead with EXIT signs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 13 April 2022
Resolution: Proper markings are in place. Defeciency was cleared.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 March 2022
Resolved
Charts must be updated for the operating area.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 13 April 2022
Resolution: Updated navigational charts are onboard and available. Defeciency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 February 2022
Resolved
Transvers frame is wated in the portside void, adjacent to the forward head. Crop and renew to good steel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 21 March 2022
Resolution: The area of concern was satisfactorily renewed and the deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2021
Resolved
Port ship service diesel generator (SSDG) overheated, and shut down. Prove proper operation of two SSDG IAW §120.310, prior to carrying passengers for hire.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2021
Resolved 15 September 2021
Resolution: Renewed the water pump and thermostats, test ran for 2 hours underload, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2021
Resolved
COI allows 389 total persons on board. There are only 274 adult sized life preservers, so the total persons allowed on board is now limited to 274, until an appropriate number of approved life preservers are procured and in place.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 13 April 2022
Resolution: An additional 95 Type I PFDs were added to the 274 acceptable PFDs that were onboard. Defeciency is cleared, and allowable passenger count is IAW COI.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 16 April 2021
Resolved
Corrosion is evident on the superstructure's exterior bulkhead, on the starboard side/aft, where the second deck meets the overhead of the first deck. Crop and renew to good metal.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 19 May 2021
Resolution: Inspected repairs and found them to be satisfactory. Deficiency is cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 16 April 2021
Resolved
Replace broken window on the starboard side aft, in the bar area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 16 June 2021
Resolution: Window was replaced and the deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2021
Resolved
Rewrite the vessel's Station Bill, IAW §122.514. Remove persons not elligible for safety sensative positions, due to non-participation in chemical testing programs IAW §16.201. Ensure posted bills are the same throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 16 June 2021
Resolution: The company rewrote the vessel's Station Bill, which delineates crew responsibilities during emergencies. Deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2020
Resolved
COI requires 398 Adult Life Jackets and the vessel has only 328 serviceable Adult Life Jackets on-board. Total persons on-board is limited to 328 until sufficient replacements are procured.
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 17 June 2021
Resolution: Serviceable adult life jackets on board is now only 274. Reduced total persons allowed on board to 274 until sufficient replacements are procured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2020
Resolved
Due to the number of outstanding worklist items, caused by the pandemic shut-down; the vessel must complete a satisfactory follow up inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 16 June 2021
Resolution: Satisfactory Annual Inspection completed and the deficiency was cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 December 2019
Resolved
Vessel has not satisfactorily completed Drydock and ISE exam. Credit has been temporarily granted to accomidate vessels schedule for 02 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2019
Resolved 31 December 2019
Resolution: The vessel received credit for a satisfactory dry dock and internal structural examinations. Deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Main deck secured to all passengers and non-essential crew. Galley secured until further notice.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Restricted to River route only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: Restriction removed; the vessel may operate within the constraints of the Routes and Conditions noted on their COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Vessel to suspend all passenger operations on 15DECEMBER2019 until satisfactory completion of drydock exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: The suspention of passenger operations is lifted in light of the completion of a successful, Dry Dock examination. The vessel may operate within the constraints of their COI.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 1 November 2019
Resolved
The collision blkhd has wastage clear across the bottom of the up from the deck 6-8"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Repairs to wastage noted on the collision bulkhead has been satisfactorily repaired. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2019
Resolved
The deck of the forward lower head(s) is also the top of the sewage tank and is showing severe wastage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Wasted areas on the sewage holding tank have been renewed and the tank is fit for its intended use. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019
Resolved
Port side outboard of the lower head has 3 wasted frames as well as the longitudinal frame in the same area is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Wasted areas have been renewed and the deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2019
Resolved
Bilge suction line in the port side of the galley is broken. (it's not for the galley bilge suction it's just located in there)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: The bilge suction line was satisfactorily repaired and the deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019
Resolved
Several (at least least 8) frames in the galley are wasted. Crop and renew
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Frames renewed as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019
Resolved
The keel cooler, aft of the STBD MDE is leaking into the E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2019
Resolution: Renewed as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019
Resolved
Keel cooler purge valves in the Lazzerette are broke off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Resolved as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 September 2019
Resolved
Starboard SSDG suffered a failure of the front seal, resulting in a loss of lube oil.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2019
Resolved 4 September 2019
Resolution: Generator was tested under load and all tests were satisfactory. Deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2019
Resolved
STBD generator will nnot start.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2019
Resolved 17 August 2019
Resolution: Repairs complete. New blower and injectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2019
Resolved
Replace personal floatation devices that were deteriorated and those that were missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Company purchased (95) replacement Type I PFDs and put on station. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 March 2019
Resolved
Last drill recorded was in March 2018. Conduct drills prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Emergency drills were conducted to the satisfaction of CG MIs. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 March 2019
Resolved
Prove proper operation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Fire pump is in operational condition. Deficiency was cleared.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2019
Resolved
Updated charts for the operating area must be onboard prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Updated charts are onboard. Deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2019
Resolved
Conduct required security drills and exercises in accordance with 33CFR104.230, and document/record completion of same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2019
Resolved 4 April 2019
Resolution: Drill and excercise completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2018
Resolved
The company does not have a DOT Drug Testing Program for employees that are serving in a safety sensitive position. Fully implement a DOT Drug Testing Program and pass a U.S. Coast Guard DAPI Audit within 60 days.
Action required: 10 - Deficiency Rectified
Due 4 February 2019
Resolved 3 April 2019
Resolution: Company established a DOT Drug Testing Program; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2018
Resolved
Re-label power panels throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 14 March 2019
Resolution: Panels are correctly labeled. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 November 2018
Resolved
Crop and renew wasted steel frame in the forward, lower, port head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 14 March 2019
Resolution: Wasted area renewed to good steel. Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018
Resolved
Conduct DAPI Audit w/CG by 12/15/2019.
Action required: 705 - Other - as specified
Due 15 December 2018
Resolved 3 April 2019
Resolution: IO completed audit, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2018
Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be effectively insulted. The port main engine exhuast piping at the exhaust manifold in not insulated or water cooled. Properly insulate the exposed exhaust piping within 7 days IAW 46 CFR 180.20-15 and 182.15-15(b).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2018
Resolved 20 July 2018
Resolution: Renewed the affected piece of lagging, all sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 May 2018
Resolved
Missing port propeller.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2018
Resolved 25 May 2018
Resolution: Propeller replaced with brace welded to shaft to prevent loss.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 30 April 2018
Resolved
AIS transponder must be activated while the vessel is underway.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 30 April 2018
Resolved 1 May 2018
Resolution: AIS transponder is operational. Deficiency cleared.
Construction/Loadline › Structures › Superstructure
Issued 20 April 2018
Resolved
Crop and renew wasted area on superstructure just forward of the access door on the starboard quarter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 8 May 2018
Resolution: Wasted area was copped out and new steel installed. Deficiency was cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2018
Resolved
Starboard generator has an exhaust leak on piping.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 8 May 2018
Resolution: Exhaust pipe repaired. No exhaust leak and deficiency was cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2018
Resolved
There is an anti-freeze leak on pipe going from the generator to the keel-cooler.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 8 May 2018
Resolution: Flange gasket was replaced and leak repaired. Deficiency was cleared.
Fire Fighting › Fire Pumps › Bearings
Issued 12 April 2018
Resolved
Fire pump, driven off of the port MDE, is not creating adequate pressure to supply hoses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2018
Resolved 13 April 2018
Resolution: Ship's crew found impellor blade lodged in pipe. Debris removed and system operated satisfactorily when tested. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 April 2018
Resolved
Lable breakers on auxiliary galley, panelboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: Panel properly labled. Deficiency cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 April 2018
Resolved
Secure mounting bracket of B-II extinguisher in Main Deck Food Service Area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: Bracket firmly attached. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 April 2018
Resolved
Secure floor matting on deck in the Main Deck Food Service Area. Matt is currently a tripping hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Flooring was relaid, and mat now lays flat. Deficiency cleared.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2018
Resolved
Lights in the aft bar/food prep area must have covers installed over bulbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: New covers were installed. Deficiency cleared.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 April 2018
Resolved
Fixture in the galley is currently in place with "zip-ties" and must be permanently installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Light fixture was permanently attached to the overhead. Deficiency was cleared.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 April 2018
Resolved
Receptical on aft bulkhead of the engine room is missing a cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Receptical was replaced and the deficiency was cleared.
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2018
Resolved
Cover is missing for pig-tail aboard the vessel that attaches to shore-tie cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 November 2018
Resolution: Satisfactory cover in place on shore-tie cable. Deficiancy cleared.
Construction/Loadline › Structures › Door
Issued 12 April 2018
Resolved
Access door on the port quarter has extensive wastage along the bottom and sides of the door. Must be renewed to good steel or replaced altogether.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 8 May 2018
Resolution: Wasted area was cropped out and new steel welded in place. Deficiency was cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 April 2018
Resolved
Crop and renew the bottom three (3) stairs heading down to the galley, which are wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 7 June 2018
Resolution: Wasted stairs were removed and replaced to the satisfaction of marine inspectors. Deficiency is cleared.
Accommodation/Occupational Safety › Messroom › Location
Issued 2 November 2016
Resolved
Sanitize the galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 5 November 2016
Resolution: The cleanliness of the galley is markedly improved. Deficiency was removed.
Accommodation/Occupational Safety › Messroom › Location
Issued 2 November 2016
Resolved
Have galley/food prep area inspected by local heath/food service inspector. Coast Guard to attend inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2016
Resolved 12 April 2018
Resolution: Vessel produced satisfactory inspection form from City Health Inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016
Resolved
Repair oil leaks on Port SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 12 April 2018
Resolution: Inspected generator after operation and found to be is satisfactory condition. Deficiency cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016
Resolved
Prove proper operation of starboard SSDG, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 5 November 2016
Resolution: Starboard generator was operated satisfactorily and the deficiency removed.
Engineering › Steering Gear System › Cable
Issued 14 July 2016
Resolved
Cable parted. No indication of binding or wear, cable is to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2016
Resolved 22 July 2016
Resolution: Conducted a satisfactory full range of motion test of the ship's steering system. Deficiency cleared.