MAURY USCG vessel records
← All vessels

NAUTICA QUEEN

NAUTICA QUEEN is a 1981 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2016, most recently in May 2026, along with 61 deficiencies and 8 casualty investigations between 2005 and 2018.

Records from 2005 to 2026. Most recent: inspection, 28 May 2026.

Built
1981
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDP6766
Flag
UNITED STATES
Maury page id
psix-52563

Inspections, by type

…with no type recorded5
Years with a record 10 calendar years (2016–2026)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)102.3 ft × 31.1 ft × 8.9 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCLEVELAND, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TIKI BARGE I Passenger (Inspected) · MISLE 1609564 · 22 May 2021 · activity 7205588

Inspection history · 38

28 May 2026 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8392727
28 April 2025 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8112985
1 October 2024 MTSA Verification · In-Service Inspection · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8012259
17 July 2024 Deadweight Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7961481
16 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7913311
21 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7828137
4 July 2023 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7733378
10 April 2023 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7667061
9 April 2023 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7679242
5 April 2023 In-Service Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7663068
5 December 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7604268
1 September 2022 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7548706
18 August 2022 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7537490
25 June 2022 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7488933
10 February 2022 Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7394206
11 September 2021 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7311341
18 August 2021 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7291068
22 May 2021 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7205588
16 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7176354
28 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6962637
30 January 2020 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6899243
1 November 2019 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6846916
1 September 2019 Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6803555
16 August 2019 In-Service Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6785393
4 April 2019 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6655995
4 March 2019 COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6635860
5 December 2018 DAPI Audit
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6597749
8 November 2018 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6577102
7 July 2018 Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6474672
7 June 2018 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6437033
20 May 2018 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6430532
19 May 2018 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6423734
30 April 2018 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6405071
12 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6390389
12 April 2018 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6405043
27 November 2016 Security Breach
Type not classified · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6049830
2 November 2016 Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6033798
14 July 2016 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5940307

Deficiency record · 61

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 July 2023 Resolved
The owner of a documented vessel must annually renew each endorsement upon the current Certificate (COD) of Documentation for that vessel in accordance with 46 CFR 67.165. Vessel's COD expired in April of 2023. The vessel owner failed to renew the COD, which resulted in the vessel operating on an expired COD. Vessel owner must apply for renewal of COD and provide proof of application to the Coast Guard prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 July 2023
Resolved 7 July 2023
Resolution: Operator/owner provided sufficient evidence for application for COD through NVDC.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 April 2023 Resolved
The starboard side-light's lens is melted; displaying an incorrect signal. Replace with appropriate light and lens, prior to operations between sunset and sunrise.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 April 2023
Resolved 5 April 2023
Resolution: Corrected on the spot, deficeincy is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 April 2023 Resolved
Daytime visual distress signals are expired. Replace with appropriate flares.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 April 2023
Resolved 5 April 2023
Resolution: Corrected on the spot. The deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023 Resolved
Prove compliance with Drug & Alcohol Programs, per 46CFR16, by completing a successful DAPI Audit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 28 April 2023
Resolution: Completed Chemical Testing Program Compliance Audit. Deficiency was cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2023 Resolved
Review compliance with security program requirements IAW 33CFR104, to include updated drills and exercises.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 28 April 2023
Resolution: The vessel is enrolled in and implementing the PVA, Alternative Security Plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 December 2022 Resolved
The 110v distribution pannel emergency cut off breaker is faulty. Prove proper operation of said breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2022
Resolved 6 December 2022
Resolution: Breaker renewed ested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's main engine is overheating due to an anti-freeze leak. Vessel is make permanent repairs to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2022
Resolved 23 August 2022
Resolution: New gasket was put on the engine block and the MDE was run at operating temperature, with no leaks noted. The deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 March 2022 Resolved
The float light on the Type IV, ring buoy, needs an approved battery.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 13 April 2022
Resolution: New floatlight w/appropriate battery has been attached to the life-float. Defeciency is cleared.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 March 2022 Resolved
Mark the escape route via the doors on the second deck after bulkhead with EXIT signs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2022
Resolved 13 April 2022
Resolution: Proper markings are in place. Defeciency was cleared.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 March 2022 Resolved
Charts must be updated for the operating area.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 13 April 2022
Resolution: Updated navigational charts are onboard and available. Defeciency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 February 2022 Resolved
Transvers frame is wated in the portside void, adjacent to the forward head. Crop and renew to good steel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2022
Resolved 21 March 2022
Resolution: The area of concern was satisfactorily renewed and the deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2021 Resolved
Port ship service diesel generator (SSDG) overheated, and shut down. Prove proper operation of two SSDG IAW §120.310, prior to carrying passengers for hire.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2021
Resolved 15 September 2021
Resolution: Renewed the water pump and thermostats, test ran for 2 hours underload, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2021 Resolved
COI allows 389 total persons on board. There are only 274 adult sized life preservers, so the total persons allowed on board is now limited to 274, until an appropriate number of approved life preservers are procured and in place.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 13 April 2022
Resolution: An additional 95 Type I PFDs were added to the 274 acceptable PFDs that were onboard. Defeciency is cleared, and allowable passenger count is IAW COI.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 16 April 2021 Resolved
Corrosion is evident on the superstructure's exterior bulkhead, on the starboard side/aft, where the second deck meets the overhead of the first deck. Crop and renew to good metal.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 19 May 2021
Resolution: Inspected repairs and found them to be satisfactory. Deficiency is cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 16 April 2021 Resolved
Replace broken window on the starboard side aft, in the bar area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 16 June 2021
Resolution: Window was replaced and the deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2021 Resolved
Rewrite the vessel's Station Bill, IAW §122.514. Remove persons not elligible for safety sensative positions, due to non-participation in chemical testing programs IAW §16.201. Ensure posted bills are the same throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2021
Resolved 16 June 2021
Resolution: The company rewrote the vessel's Station Bill, which delineates crew responsibilities during emergencies. Deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2020 Resolved
COI requires 398 Adult Life Jackets and the vessel has only 328 serviceable Adult Life Jackets on-board. Total persons on-board is limited to 328 until sufficient replacements are procured.
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 17 June 2021
Resolution: Serviceable adult life jackets on board is now only 274. Reduced total persons allowed on board to 274 until sufficient replacements are procured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2020 Resolved
Due to the number of outstanding worklist items, caused by the pandemic shut-down; the vessel must complete a satisfactory follow up inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 16 June 2021
Resolution: Satisfactory Annual Inspection completed and the deficiency was cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 December 2019 Resolved
Vessel has not satisfactorily completed Drydock and ISE exam. Credit has been temporarily granted to accomidate vessels schedule for 02 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2019
Resolved 31 December 2019
Resolution: The vessel received credit for a satisfactory dry dock and internal structural examinations. Deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Main deck secured to all passengers and non-essential crew. Galley secured until further notice.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Restricted to River route only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: Restriction removed; the vessel may operate within the constraints of the Routes and Conditions noted on their COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019 Resolved
Vessel to suspend all passenger operations on 15DECEMBER2019 until satisfactory completion of drydock exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2019
Resolved 31 December 2019
Resolution: The suspention of passenger operations is lifted in light of the completion of a successful, Dry Dock examination. The vessel may operate within the constraints of their COI.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 1 November 2019 Resolved
The collision blkhd has wastage clear across the bottom of the up from the deck 6-8"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Repairs to wastage noted on the collision bulkhead has been satisfactorily repaired. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 November 2019 Resolved
The deck of the forward lower head(s) is also the top of the sewage tank and is showing severe wastage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Wasted areas on the sewage holding tank have been renewed and the tank is fit for its intended use. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019 Resolved
Port side outboard of the lower head has 3 wasted frames as well as the longitudinal frame in the same area is wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: Wasted areas have been renewed and the deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 November 2019 Resolved
Bilge suction line in the port side of the galley is broken. (it's not for the galley bilge suction it's just located in there)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 31 December 2019
Resolution: The bilge suction line was satisfactorily repaired and the deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 November 2019 Resolved
Several (at least least 8) frames in the galley are wasted. Crop and renew
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Frames renewed as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019 Resolved
The keel cooler, aft of the STBD MDE is leaking into the E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2019
Resolution: Renewed as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2019 Resolved
Keel cooler purge valves in the Lazzerette are broke off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Resolved as specified in narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 September 2019 Resolved
Starboard SSDG suffered a failure of the front seal, resulting in a loss of lube oil.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2019
Resolved 4 September 2019
Resolution: Generator was tested under load and all tests were satisfactory. Deficiency is cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2019 Resolved
STBD generator will nnot start.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2019
Resolved 17 August 2019
Resolution: Repairs complete. New blower and injectors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2019 Resolved
Replace personal floatation devices that were deteriorated and those that were missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Company purchased (95) replacement Type I PFDs and put on station. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 March 2019 Resolved
Last drill recorded was in March 2018. Conduct drills prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Emergency drills were conducted to the satisfaction of CG MIs. Deficiency cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 March 2019 Resolved
Prove proper operation prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Fire pump is in operational condition. Deficiency was cleared.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2019 Resolved
Updated charts for the operating area must be onboard prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2019
Resolved 28 March 2019
Resolution: Updated charts are onboard. Deficiency is cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 March 2019 Resolved
Conduct required security drills and exercises in accordance with 33CFR104.230, and document/record completion of same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2019
Resolved 4 April 2019
Resolution: Drill and excercise completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2018 Resolved
The company does not have a DOT Drug Testing Program for employees that are serving in a safety sensitive position. Fully implement a DOT Drug Testing Program and pass a U.S. Coast Guard DAPI Audit within 60 days.
Action required: 10 - Deficiency Rectified
Due 4 February 2019
Resolved 3 April 2019
Resolution: Company established a DOT Drug Testing Program; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2018 Resolved
Re-label power panels throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 14 March 2019
Resolution: Panels are correctly labeled. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 November 2018 Resolved
Crop and renew wasted steel frame in the forward, lower, port head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 14 March 2019
Resolution: Wasted area renewed to good steel. Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 November 2018 Resolved
Conduct DAPI Audit w/CG by 12/15/2019.
Action required: 705 - Other - as specified
Due 15 December 2018
Resolved 3 April 2019
Resolution: IO completed audit, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 July 2018 Resolved
The part of the exhaust system between the point of cooling water injection and the engine manifold shall be effectively insulted. The port main engine exhuast piping at the exhaust manifold in not insulated or water cooled. Properly insulate the exposed exhaust piping within 7 days IAW 46 CFR 180.20-15 and 182.15-15(b).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2018
Resolved 20 July 2018
Resolution: Renewed the affected piece of lagging, all sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 19 May 2018 Resolved
Missing port propeller.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2018
Resolved 25 May 2018
Resolution: Propeller replaced with brace welded to shaft to prevent loss.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 30 April 2018 Resolved
AIS transponder must be activated while the vessel is underway.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 30 April 2018
Resolved 1 May 2018
Resolution: AIS transponder is operational. Deficiency cleared.
Construction/Loadline › Structures › Superstructure
Issued 20 April 2018 Resolved
Crop and renew wasted area on superstructure just forward of the access door on the starboard quarter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 8 May 2018
Resolution: Wasted area was copped out and new steel installed. Deficiency was cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2018 Resolved
Starboard generator has an exhaust leak on piping.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 8 May 2018
Resolution: Exhaust pipe repaired. No exhaust leak and deficiency was cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2018 Resolved
There is an anti-freeze leak on pipe going from the generator to the keel-cooler.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2018
Resolved 8 May 2018
Resolution: Flange gasket was replaced and leak repaired. Deficiency was cleared.
Fire Fighting › Fire Pumps › Bearings
Issued 12 April 2018 Resolved
Fire pump, driven off of the port MDE, is not creating adequate pressure to supply hoses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2018
Resolved 13 April 2018
Resolution: Ship's crew found impellor blade lodged in pipe. Debris removed and system operated satisfactorily when tested. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 April 2018 Resolved
Lable breakers on auxiliary galley, panelboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: Panel properly labled. Deficiency cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 April 2018 Resolved
Secure mounting bracket of B-II extinguisher in Main Deck Food Service Area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: Bracket firmly attached. Deficiency cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 April 2018 Resolved
Secure floor matting on deck in the Main Deck Food Service Area. Matt is currently a tripping hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Flooring was relaid, and mat now lays flat. Deficiency cleared.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2018 Resolved
Lights in the aft bar/food prep area must have covers installed over bulbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 20 April 2018
Resolution: New covers were installed. Deficiency cleared.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 April 2018 Resolved
Fixture in the galley is currently in place with "zip-ties" and must be permanently installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Light fixture was permanently attached to the overhead. Deficiency was cleared.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 April 2018 Resolved
Receptical on aft bulkhead of the engine room is missing a cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 May 2018
Resolution: Receptical was replaced and the deficiency was cleared.
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2018 Resolved
Cover is missing for pig-tail aboard the vessel that attaches to shore-tie cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2018
Resolved 8 November 2018
Resolution: Satisfactory cover in place on shore-tie cable. Deficiancy cleared.
Construction/Loadline › Structures › Door
Issued 12 April 2018 Resolved
Access door on the port quarter has extensive wastage along the bottom and sides of the door. Must be renewed to good steel or replaced altogether.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 8 May 2018
Resolution: Wasted area was cropped out and new steel welded in place. Deficiency was cleared.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 April 2018 Resolved
Crop and renew the bottom three (3) stairs heading down to the galley, which are wasted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 7 June 2018
Resolution: Wasted stairs were removed and replaced to the satisfaction of marine inspectors. Deficiency is cleared.
Accommodation/Occupational Safety › Messroom › Location
Issued 2 November 2016 Resolved
Sanitize the galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2016
Resolved 5 November 2016
Resolution: The cleanliness of the galley is markedly improved. Deficiency was removed.
Accommodation/Occupational Safety › Messroom › Location
Issued 2 November 2016 Resolved
Have galley/food prep area inspected by local heath/food service inspector. Coast Guard to attend inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2016
Resolved 12 April 2018
Resolution: Vessel produced satisfactory inspection form from City Health Inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016 Resolved
Repair oil leaks on Port SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 12 April 2018
Resolution: Inspected generator after operation and found to be is satisfactory condition. Deficiency cleared.
Electrical › Electric Generation Source (service) › Generator
Issued 2 November 2016 Resolved
Prove proper operation of starboard SSDG, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 5 November 2016
Resolution: Starboard generator was operated satisfactorily and the deficiency removed.
Engineering › Steering Gear System › Cable
Issued 14 July 2016 Resolved
Cable parted. No indication of binding or wear, cable is to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2016
Resolved 22 July 2016
Resolution: Conducted a satisfactory full range of motion test of the ship's steering system. Deficiency cleared.

Casualty record · 8

6 July 2005Routine · role: Involved in a Marine Casualty · activity 2440646
27 September 2008Routine · role: Involved in a Marine Casualty · activity 3340940
20 July 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3541641
23 April 2010Routine · role: Involved in a Marine Casualty · activity 3726282
18 August 2010Routine · role: Involved in a Marine Casualty · activity 3828128
18 November 2010Routine · role: Involved in a Marine Casualty · activity 3894598
20 August 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4125945
20 May 2018Routine · role: Involved in a Marine Casualty · activity 6430532
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.