Records from 1985 to 2006. Most recent: inspection, 1 June 2006.
Inspection history · 47
1 June 2006
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2667306
24 October 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2522412
13 June 2005
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2375889
3 August 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2156830
9 June 2004
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2086320
2 August 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1868431
17 June 2003
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1838488
26 October 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1701502
28 May 2002
Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1626313
21 March 2002
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1495628
24 July 2001
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1069681
5 June 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1401494
6 October 2000
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 823152
18 July 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1433695
15 June 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 57022
15 June 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 178048
5 June 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 26739
3 August 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 51229
14 July 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1408343
25 April 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 127655
16 June 1998
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1434742
25 May 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 126164
16 September 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 135115
14 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 783566
17 May 1997
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1447713
26 September 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 156892
7 March 1996
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1078290
10 March 1995
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390025
14 June 1994
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1017374
8 March 1994
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1166125
11 March 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 833495
18 March 1992
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 952215
21 March 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 927363
14 March 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1238856
21 May 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 912521
14 April 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 906980
19 April 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1033971
19 May 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1201326
9 May 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1346649
9 April 1988
COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1341904
14 March 1988
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992641
23 July 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1334336
12 April 1987
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1008382
9 April 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1010611
13 May 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1296824
12 April 1986
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1308481
10 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982102
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 13 June 2005
No resolution recorded
Properly repair stern cracked window IAW 46CFR177.1010 (Window construction and visibility requirement).
Action required: 705 - Other - as specified
Due 20 July 2005 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 June 2005
No resolution recorded
IAW 46CFR183.310, wire masthead light to 12 volt system.
Action required: 705 - Other - as specified
Due 20 July 2005 — due date passed with no resolution recorded
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 13 June 2005
Resolved
IAW 46CFR180.70.d.3 properly install a corrosion resistant clip allowing the waterlight to be quickly disconnected from the ring life buoy.
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 20 June 2005
Resolution: Clip was properly installed on waterlight lanyard.
Electrical › Electric Supply System (service)
Issued 9 June 2004
Resolved
Hard wire 110 volt battery charger IAW 46 CFR 183.310 and NEC. LEGACY COMPONENT DESC: Battery Conductor
Due 9 July 2004
Resolved 11 June 2004
Resolution: Battery charger properly hard wired.
Engineering › Fuel Oil Service System › Valve
Issued 9 June 2004
Resolved
Replace emergency fuel shut-off valve on aft port fuel tank IAW 46 CFR 176.804 (f).
Do not use tank until valve is replaced.
Due 9 July 2004
Resolved 14 June 2005
Construction/Loadline › Structures
Issued 21 March 2002
Resolved
Provide repair proposal for stern structural support leading to second deck. LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2002
Resolved 21 March 2002
Engineering › Bilge Water Management System
Issued 21 March 2002
Resolved
Provide strainers for each bilge suction line IAW 46 CFR 182.510 (b). LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 28 May 2002
Construction/Loadline › Penetrations
Issued 21 March 2002
Resolved
Plug holes at lower end of each water tight bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 28 May 2002
Construction/Loadline › Hull
Issued 21 March 2002
Resolved
Prior to changing out thru hull fittings, submit changes/materials to be used.
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 28 May 2002
Engineering
Issued 5 June 2001
Resolved
Provide improved method for keeping children from accessing belt room priorto 07JUL01 to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Electrical
Issued 18 July 2000
Resolved
Reconnect junction box to panel.
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 18 July 2000
Resolved
Install check valve on discharge side of electric fire/bilge pump, preventing back flow of main engine fire fighting water.
Condition: Unknown
Due 18 July 2000
Resolved 18 July 2000
Electrical
Issued 18 July 2000
Resolved
Install belt cover on generator.
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 16 June 1998
Resolved
PROVIDE ONE OF THE FOLLOWING OPTIONS TO THE ENGINE ROOM: A) PROVE THAT THE INSULATION PRESENTLY INSTALLED MEETS THE REQUIREMENTS OF 46CFR 164.009 OR B) REMOVE THE INSULATION OR C) PROVIDE A FIXED FIRE EXTINGUISHING SYSTEM WHICH MEETS 46CFR 181.400. CORRECT THE ABOVE REQUIREMENTS PRIOR TO 19JUN99.
Condition: Unknown
Due 16 June 1998
Resolved 16 June 1998
Lifesaving
Issued 17 May 1997
Resolved
Perform simplified stability test for 152 persons (149+3)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Fire Fighting
Issued 17 May 1997
Resolved
Mount BII extinguisher in the galley._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Construction/Loadline
Issued 17 May 1997
Resolved
Repair pin hole in hull in bow area on the port side._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1997
Resolved 12 June 1997
Construction/Loadline
Issued 17 May 1997
Resolved
Install bilge high level alarms._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Documentation
Issued 17 May 1997
Resolved
PROVIDE SCALED DRAWINGS ON THE UPPER DECK MODS TO THE VESSEL. ALSO PROVIDE CALCULATIONS ON WEIGHT ADDED/REMOVED ON THE UPPER DECK TO FACILITATE RECALCULATING VESSEL STABILITY._x001C_ _x001C_
Condition: Unknown
Due 3 July 1997
Resolved 7 July 1997
Accommodation/Occupational Safety
Issued 17 May 1997
Resolved
Remove standing liquid under sewage tank and investigate liquid tight integrity of the tank._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1997
Resolved 12 June 1997
Engineering
Issued 17 May 1997
Resolved
Demonstrate vessels propulsion system, including steering, alarms and ventilation systems._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Navigation
Issued 17 May 1997
Resolved
Demonstrate navigation lights._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Unknown
Issued 17 May 1997
Resolved
Conduct satisfactory man overboard and fire drills._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Construction/Loadline
Issued 17 May 1997
Resolved
Make proper bulkhead penetrations in W/T bulkheads where fuel supply and return lines penetrate the bulkhead._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Navigation
Issued 17 May 1997
Resolved
Perform a satisfactory P/A system and radio check._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Electrical
Issued 17 May 1997
Resolved
Demonstrate emergency lighting._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Lifesaving
Issued 17 May 1997
Resolved
Procure life jacket donning placard._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Lifesaving
Issued 17 May 1997
Resolved
Provide inventory and operating instructions for first aid kit._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Lifesaving
Issued 17 May 1997
Resolved
Prove proper operation of float light on ring buoy._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Fire Fighting
Issued 17 May 1997
Resolved
Prove proper operation of installed fire pump, hoses and nozzles._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Electrical
Issued 17 May 1997
Resolved
Demonstrate vessels electrical generator plant under a load._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1997
Resolved 12 June 1997
Engineering
Issued 8 March 1994
Resolved
RENEW SEAL ON PADDLE WHEEL DRIVE SHAFT.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Engineering
Issued 8 March 1994
Resolved
INSTALL INSULATION IN WAY OF MAIN DIESEL EXHAUST MUFFLER.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Engineering
Issued 8 March 1994
Resolved
RENEW ALL CRACKED AND ROTTED PADDLE WHEEL BOARDS AS NECESSARY.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Fire Fighting
Issued 8 March 1994
Resolved
RENEW TWO (2) REQUIRED 1.5"X50' FIRE HOSES. CORRECT PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Documentation
Issued 11 March 1993
Resolved
INSTALL DRAFT MARKS OR LOADING MARKS AS DESCRIBED IN 46 CFR 185.30-3 PRIOR TO COMPLETION OF THE NEXT ROUTINE DRYDOCKING.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 18 March 1992
Resolved
CROP AND RENEW TO GOOD WOOD DRY ROTTED WOOD AT THE BASE OF THE STARBOARD LADDER ON THE MAIN DECK.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Accommodation/Occupational Safety
Issued 18 March 1992
Resolved
PROVIDE TREADED CAP FOR MAIN DECK WASTE PUMP OUT PIPE ON PORT SIDE OF VESSEL.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Engineering
Issued 18 March 1992
Resolved
INSTALL VENT COVERS ON THE SUPPLY VENTS IN PORT AND STARBOARD SIDE OF THE _x001C_VESSEL'S HULL VENT OPENINGS.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Accommodation/Occupational Safety
Issued 18 March 1992
Resolved
PROPERLY SECURE MICRO WAVE OVEN.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Electrical
Issued 14 March 1991
Resolved
REMOVE "SJ/SJO" WIRING TO BATTERY CHARGER AND ENGINE ROOM BATTERY. REPLACEWITH MULTI-STRAND COPPER, UL APPROVED, WIRING WITH AT LEAST A 75 DEG C RATING. CIRCUIT BREAKERS TO BE RATED TO AMPACITY OF CONDUCTOR.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Construction/Loadline
Issued 14 March 1991
Resolved
REWELD CRACK IN COLLISION BULKHEAD CENTERLINE NEAR DECK NO LATER THAN NEXT DRYDOCK OR 30APR92.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Lifesaving
Issued 14 March 1991
Resolved
REPLACE ONE WASTED RING BUOY, TEMPORARY REPAIR ON GRAB LINE WILL SUFFICE UNTIL REPLACEMENT.
Condition: Unknown
Due 14 March 1991
Resolved 14 March 1991
Electrical
Issued 14 April 1990
Resolved
INSTALL PROPER CIRCUIT BREAKER BLANK IN OLD GENERATOR BREAKER BOX.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
INSTALL METALLIC WIRE SUPPORTS AT LEAST EVERY 24 INCHES THROUGHOUT VESSEL.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
MODIFY ELECTRICAL SHORE-TIE TO INCLUDE WATERTIGHT RECEPTABLE PLUG AND PREVENT PERMANENT INSTALLATION OF "SO" PORTABLE CORD. SHORE-TIE CONNECTIONTO BE RELOCATED AWAY FROM FUEL TANK VENTS (AT LEAST 10 FEET).
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
INDEPENDENT GENERATOR INSTALLATION TO BE VERIFIED IF CONNECTED TO 120 VOLT OR 24O VOLT. GENERATOR CONDUCTOR TO BE RATED FOR AMPACITY OUTPUT OF GENERATOR. CIRCUIT PROTECTION TO BE RATED ACCORDINGLY.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
ALL "SJ/SO" AND SOLID CORE WIRING TO BE REPLACED WITH ACCEPTABLE MULTI-STRAND COPPER CONDUCTOR, UL APPROVED AND AT LEAST 75 DEGREE C RATING.CIRCUIT BREAKERS TO BE RATED TO AMPACITY OF CONDUCTOR.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
ADDITIONAL ELECTRICAL RECEPTACLES TO BE INSTALLED IN PILOT HOUSE TO HANDLE APPLIANCES. RECEPTACLE TO BE PROTECTED BY CIRCUIT PROTECTION.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
REFRIGERATOR IN LAZARETTE TO BE PROVIDED WITH PERMANENTLY INSTALLED WIRING AND RECEPTACLE. EXTENSION CORDS TO BE REMOVED.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
IN WHEELHOUSE, REMOVE ALL DEADENDED WIRING, REMOVE WIRENUTS AND REPLACE WITH COMPRESSION CONNECTORS, REMOVE "SJ/SO" PORTABLE CORD, SUPPORT ALL WIRING EVERY 24 INCHES WITH METALLIC CLIPS.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Documentation
Issued 14 April 1990
Resolved
PROVIDE ORIGINAL CG VESSEL DOCUMENTATION ON BOARD VESSEL.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Navigation
Issued 14 April 1990
Resolved
PROVIDE COPY OF NAVIGATIONAL RULES OF ROAD AND NAVIGATIONAL CHART ON BOARD.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Documentation
Issued 14 April 1990
Resolved
PROVIDE POLLUTION PLACARDS IN EACH MACHINERY SPACE (ENGINE AND GENERATOR).
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Fire Fighting
Issued 14 April 1990
Resolved
PROVIDE RUBBER-LINED UL APPROVED 1.5 INCH X 50 FEET FIRE HOSE.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Accommodation/Occupational Safety
Issued 14 April 1990
Resolved
LABEL ABOVE BATHROOM SINKS, THAT WATER IS NOT DRINKABLE.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Accommodation/Occupational Safety
Issued 14 April 1990
Resolved
REPLACE EXISTING HOT WATER HEATER RELIEF VALVE WITH ONE RATED AT 100 PSI/ 210 DEGREE F OR LESS.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Engineering
Issued 14 April 1990
Resolved
REPLACE EXISTING PORT AND STARBOARD DAY TANK VENTS WITH A GOOSENECK VENT WHICH PERMITS FREE VENTING AND INSTALL FLAME SCREENS WITH 30 X 30 MESH.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
INSTALL AMMETER FOR INDEPENDENT GENERATOR OR REPLACE EXISTING ONE IN WHEELHOUSE (AMMETER TO HAVE CAPACITY OF GENERATOR OUTPUT).
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Engineering
Issued 14 April 1990
Resolved
REPLACE EXISTING FUEL TANK VENT LINES WITH AT LEAST 5/8 INCH DIAMETER PIPE OR TUBING.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Engineering
Issued 14 April 1990
Resolved
INSTALL SUITABLE HANDLES ON ALL BILGE CONTROL VALVES.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Construction/Loadline
Issued 14 April 1990
Resolved
DISCONNECT AND PLUG UNUSED GENERATOR COOLING PIPING WHICH PENETRATES WATER TIGHT BULKHEADS TO MAINTAIN WATERTIGHTNESS.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 14 April 1990
Resolved
INSTALL AMMETER FOR BATTERY CHARGER.
Condition: Unknown
Due 14 April 1990
Resolved 14 April 1990
Electrical
Issued 19 April 1989
Resolved
PROVIDE VOLT AND FREQUENCY METER FOR GENERATOR IAW 46 CFR 183.10-5(G).
Condition: Unknown
Due 19 April 1989
Resolved 19 April 1989
Engineering
Issued 9 April 1988
Resolved
INSTALL REMOTE FUEL OIL SHUTOFF VALVES IAW 46 CFR 182.20-40(B)(3) TO FUEL OIL TANKS (2) LOCATED IN FWD FUEL TANK COMPARTMENT.
Condition: Unknown
Due 9 April 1988
Resolved 9 April 1988
Unknown
Issued 12 April 1987
Resolved
COMPLETE WORKLIST ITEMS # 1,2,4,5 & 6.
Condition: Unknown
Due 12 April 1987
Resolved 12 April 1987
Electrical
Issued 12 April 1987
Resolved
REMOVE EXTENSION ELECTRICAL CORDS & REPLACE WITH HARD CABLE (ELECTRICAL). PRIOR TO INSTALLATION OF THE ABOVE SUBMIT PLANS FOR APPROVAL TO THE [name withheld]/LB.
Condition: Unknown
Due 12 April 1987
Resolved 12 April 1987
Engineering
Issued 10 April 1985
Resolved
PROVIDE HEAT SHIELD FOR PLASTIC RAYCON FUEL FILTER.
Condition: Unknown
Due 10 April 1985
Resolved 10 April 1985