MAURY USCG vessel records Sign in
← All vessels

NOBLE FRI RODLI

NOBLE FRI RODLI is a 1979 mobile offshore drilling unit. The Coast Guard has recorded 55 inspections since 1981, most recently in October 2008, along with 105 deficiencies.

Records from 1981 to 2008. Most recent: inspection, 3 October 2008.

Built
1979
Last inspected
3 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8756241 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-52733

Inspections, by type

…with no type recorded25
Years with a record 21 calendar years (1981–2008)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5549 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BIG HORN RIVER Offshore Supply Vessel · MISLE 51916 · 10 February 2006 · activity 2593970BIG HORN RIVER Offshore Supply Vessel · MISLE 51916 · 10 February 2006 · activity 2615421BUFFALO RIVER Offshore Supply Vessel · MISLE 50374 · 7 December 2005 · activity 2550013

Inspection history · 55

3 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3338013
13 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3297681
4 June 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2952107
31 January 2007 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2865318
18 September 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2791841
23 May 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2679566
18 March 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2612195
10 February 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2593970
10 February 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2615421
24 January 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2611965
19 January 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2569402
18 January 2006 Annual Inspection · Commercial Dive Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2658995
7 December 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2550013
12 September 2005 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2490577
16 November 2004 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2230896
29 October 2003 COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1929541
1 July 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1831971
31 January 2003 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1803993
25 January 2002 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1481252
22 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066950
13 May 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064145
22 March 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370065
28 February 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769344
21 February 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 199366
22 January 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384658
8 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 112410
25 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057248
17 March 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449297
26 April 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794403
31 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430666
21 March 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 809663
8 July 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 794645
22 June 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1126295
22 March 1998 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398784
20 March 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789012
20 March 1998 Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426036
4 September 1997 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786438
12 April 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230486
12 December 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233596
5 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314451
14 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319612
8 October 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301034
9 August 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992764
14 June 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280492
16 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974003
26 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280811
11 January 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279436
25 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279470
19 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969400
10 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272091
29 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272633
19 January 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 970573
1 July 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967786
20 November 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277214
11 August 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278457

Deficiency record · 105

Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 January 2006 Resolved
Complete annual testing of the vessels fixed fire extinguishing system pressure operated shut down switches and audible alarms for the SCR room and Engine room
Condition: Improper/Lack of Maintenance
Due 28 January 2006
Resolved 27 January 2006
Resolution: Received technicians report of proper operation of the switches.
Lifesaving › Rocket Parachute Flares › General
Issued 14 November 2004 Resolved
Provide 12 parachute flares for the control room.
Condition: Unknown
Due 21 December 2004
Resolved 21 December 2004
Resolution: Provided 12 parachute flares for control room.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 14 November 2004 Resolved
Reverse power relay in-op #1 generator distribution panel. Maintain 24 hour manned watch over same until repaired.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 December 2004
Resolved 21 December 2004
Resolution: Reverse power relay repaired. Operational test, all sat.
Lifesaving › Lifebuoys › Size
Issued 14 November 2004 Resolved
Provide proper weighted life buoys on quick release stations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 December 2004
Resolved 21 December 2004
Resolution: Provided properly weighted life buoys.
Engineering › Diesel Engine (auxiliary)
Issued 10 November 2003 Resolved
Demonstrate proper shutdowns and alarms on spare generator prime mover including low lube oil, overspeed, and high water temp alarm. Space to be manned at all times during operation of equipment until proper demonstration of shutdowns and alarms. LEGACY COMPONENT DESC: Overspeed Device
Condition: Unknown
Due 11 December 2003
Resolved 15 November 2003
Resolution: Received fax confirmation from vessel OIM.
Engineering › Bilge Water Management System
Issued 10 November 2003 Resolved
Demonstrate proper operation of all ballast system remote operated valves in aft pump room. Until completion space must be manned during rig moves. LEGACY COMPONENT DESC: Valve
Condition: Damaged By Earlier Event
Due 31 January 2004
Resolved 31 January 2004
Resolution: Received fax confirmation from OIM attesting to installation & function test, all sat.
Lifesaving
Issued 25 January 2002 Resolved
PRIOR TO DRILLING OPERATIONS, CONDUCT FIRE AND BOAT DRILLS IN PRESENCE OF COAST GUARD MARINE INSPECTOR. LEGACY COMPONENT DESC: DRILLS
Due 25 April 2002
Resolved 15 November 2003
Resolution: Conducted fire and lifeboat drill on this date.
Navigation
Issued 22 March 2001 Resolved
PROVIDE APPROVED STERN NAVIGATION LIGHT PRIOR TO ANY RIG MOVE AT NIGHT.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Lifesaving
Issued 22 March 2001 Resolved
CROP AND RENEW HELO-DECK PERIPHERAL SAFETY NETTING SUPPORTS WHERE WASTED AND HOLED.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Construction/Loadline
Issued 22 January 2001 Resolved
PROVIDE MEANS OF MAKING LOUVERED VENTS AT TOP OF ALL THREE COLUMNS WATER TIGHT. MAKE ALL WIRING PENETRATIONS INTO COLUMNS WATER TIGHT.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 22 January 2001 Resolved
CONDUCT NDE OF NODE CONNECTIONS, PROVIDE COPY OF NDE REPORT TO [name withheld].
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 22 January 2001 Resolved
CONDUCT UNDERMAT SWIM-BY, PROVIDE COPY OF DIVER'S REPORT AND VIDEO TO [name withheld].
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 22 January 2001 Resolved
IN ALL THREE COLUMNS, SUPPORT STAGING AT SIDE SHELL STIFFENERS AND NOT AT SIDE SHELL.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 22 January 2001 Resolved
CROP AND RENEW WASTED AND HOLED UPPER VOID BOTTOM AT STARBOARD COLUMN.
Condition: Unknown
Due 31 March 2002
Resolved 3 November 2003
Resolution: Provided class report for crop and renew of wasted steel
Construction/Loadline
Issued 22 January 2001 Resolved
DE-SCALE ALL SUSPECT AREAS OF SIDE SHELL, SIDE SHELL STIFFENERS, AND RING FRAME STIFFENERS IN ALL THREE COLUMNS. GAUGE IN THE PRESENCE OF AN ABS SURVEYOR. PROVIDE COPY OF ABS REPORT AND GAUGING REPORT TO [name withheld]
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 22 January 2001 Resolved
CONDUCT NDE OF MAT TO COLUMN CONNECTIONS, PROVIDE COPY OF DIVER'S REPORT AND VIDEO TO [name withheld].
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 22 January 2001 Resolved
AT STAGING SUPPORT TO SIDE SHELL CONNECTIONS IN ALL THREE COLUMNS, DE-SCALEAND IN THE PRESENCE OF AN ABS SURVEYOR GAUGE SIDE SHELL. PROVIDE COPY OF ABS REPORT AND GAUGING REPORT TO [name withheld].
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Lifesaving
Issued 17 March 2000 Resolved
Provide means for 200% primary lifesaving equipment.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Unknown
Issued 17 March 2000 Resolved
Rig may operate with 2 lifeboatmen until starting drilling operations.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Unknown
Issued 17 March 2000 Resolved
Provide ordinary seaman per COI.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Fire Fighting
Issued 31 March 1999 Resolved
CROP AND RENEW FIREMAIN WHERE WASTED IN AFT COLUMN.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Construction/Loadline
Issued 22 March 1998 Resolved
P7 TANK: AT THE +51 FOOT LEVEL REPLACE SIDE SHELL PLATING ALONG WITH 38 VERTICAL STIFFENERS AND RING STIFFENERS, AT +35 LEVEL INSERT AN AREA APPROX8'X10' ALONG WITH 30' OF RING STIFFENERS AND VERTICAL STIFFENERS AND INSERTOLD VENT LINE OPENINGS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Documentation
Issued 22 March 1998 Resolved
PROVIDE ABS AND DIVERS REPORT OF SWIM BY OF COLUMN FOOTINGS AND UNDERSIDE OF SEA CHEST TO [name withheld]
Condition: Unknown
Due 20 April 1998
Resolved 1 May 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK P1: RENEW AS ORIGINAL 2 OVERHEAD STIFFENERS AND 4 GUSSETS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK P2: RENEW AS ORIGINAL BULKHEAD BETWEEN P-2 AND P-3 WHERE BOWED, REPLACE 5 T-BEAM STIFFENERS, 2 OVERHEAD STIFFENER, AND ONE DECK STIFFENER.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK P3: RENEW AS ORIGINAL 4 DECK STIFFENERS AND ONE OVERHEAD STIFFENER ALONG WITH 5 GUSSETS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK P4: REPLACE 7 T-BEAM STIFFENERS ON BLKHD BETWEEN P4/P3, RENEW 2 OVERHEAD STIFFENERS, 4 DECK STIFFENERS AND 3 DECK GUSSETS, AND IN PIE SECTION REPLACE 3 OVERHEAD BULKHEAD GUSSETS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK S1: RENEW #2 AND #4 FLOOR STIFFENERS OUTWARD FROM THE INNER COLUMN RING, REWELD 4 DECK BULKHEAD GUSSETS, AND IN PIE SECTION REPLACE 1 OVERHEADGUSSET.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK S2: RENEW AS ORIGINAL 6 T-BEAM STIFFENERS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
RENEW AS ORIGINAL FLOOR STIFFENERS #1,2,3,4, AND 5 OUTBOARD OF INNER COLUMNRING.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK S6: RENEW AS ORIGINAL 11 T-BEAM STIIFENERS ON THE BULKHEAD BETWEEN S6 AND S5 TOGETHER WITH GUSSETS AS NEEDED.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK S7: AT +35 LEVEL INSERT SHELL PLATE 6'X6' WITH ASSOC. STIFFENERS WHEREINDENTED, AT +51 FOOT LEVEL REPLACE VERTICAL STIFFENERS WHERE WASTED AS WELL AS SIDE SHELL PLATING, AND IN CONE SECTION INSERT OLD VENT LINE OPENINGS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK A-1: RENEW 3 OVERHEAD STIFFENERS, 4 FLOOR GUSSETS, 3 FLOOR STIFFENERS,AND 3 BROKEN T-BEAMS BACK TO BLKHD IN PIE SECTION.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
A7 TANK COLUMN: +51 TO +54 FOOT LEVEL RENEW AS ORIGINAL SIDE SHELL PLATING WHERE WASTED, AT +31 FOOT LEVELO INSERT BOAT IMPACT DAMAGE AREA.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK A4: RENEW 1 BULKHEAD AND ONE CEILING GUSSET.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK A3: REPLACE 8 T-BEAM STIFFENERS, 4 DECK STIFFENERS, AND 5 OVERHEAD STIFFENERS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 March 1998 Resolved
TANK A2: MAKE REPAIRS TO TANK A-2/A-3 COMMON BULKHEAD (BOWED), 10 DECK STIFFENERS, 13 OVERHEAD STIFFENERS, 3 OVERHEAD GUSSETS.
Condition: Unknown
Due 22 March 1998
Resolved 29 April 1998
Electrical
Issued 20 March 1998 Resolved
Provide covers for outlets in hospital room.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Unknown
Issued 20 March 1998 Resolved
Provide copy of Operations Manual to [name withheld] for review.
Condition: Unknown
Due 20 March 1998
Resolved 20 March 1998
Lifesaving
Issued 20 March 1998 Resolved
Provide copy of MSC approved plans of lifeboat platform installation, to [name withheld].
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Prove operation of eyewash station on drill floor.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Prove operation of emergency light in TV/Rec room.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Fire Fighting
Issued 20 March 1998 Resolved
Prove operation of engine CO2 shutdown for generator room CO2 system.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 20 March 1998 Resolved
Relocate reach rod for emergency generator engine fuel valve.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 20 March 1998 Resolved
Replace sight glass guard on fuel day tank.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Prove operation of purge alarm on [name withheld] box on drill floor.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Label all alarms on drill floor.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Repair emergency light in shaker area.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 20 March 1998 Resolved
Complete underwater portion of hull exam. Send report to [name withheld].
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Fire Fighting
Issued 20 March 1998 Resolved
Provide [name withheld] with MSC approved plans for fixed CO2 installationin SCR & Generator rms.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Add general alarm bell to compressor room.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Secure mud pit eyewash station, and ensure adequate water pressure.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Fire Fighting
Issued 20 March 1998 Resolved
Provide fire extinguisher for firestation #34.
Condition: Unknown
Due 20 March 1998
Resolved 20 March 1998
Electrical
Issued 20 March 1998 Resolved
Label breakers at base of accomodation stairwell.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Put OIM signature on all unsigned station bills.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Replace light bulb for interior of lifeboat #2.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Prove operation of both lifeboat #1 & #2 motor controllers.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Prove operation of emergency lights at lifeboat station #2.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Prove proper operation of alarm panel in SCR room.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Complete helo deck markings, & provide recessed tie-downs.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Provide nonconducting blank for small breaker in TV/rec room.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 20 March 1998 Resolved
Install proper size containment at fuel oil fueling stations.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 20 March 1998 Resolved
Repair holes in deck in air compressor room.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 20 March 1998 Resolved
Prove operation of the fuel oil transfer pump shutdown.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 20 March 1998 Resolved
Label manual shutdowns for fuel system for MDE's, on weather deck.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Paint warning stripes, or install guard in way of low support member, stbd side, below helo deck.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Label general alarm bells: weather deck under helideck, main deck quarters,stbd side in way of column access.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Unknown
Issued 20 March 1998 Resolved
Label vents on weatherdeck.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Label emergency lights on port side crane pedestal.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Label generator panels (#1,#2,#3).
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 20 March 1998 Resolved
Place guards around rotating machinery in aft column--bilge & potable waterpumps.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 20 March 1998 Resolved
Fix the following watertight doors so they fit properly: port, aft, & stbdcolumn doors. To be completed prior to getting underway.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 20 March 1998 Resolved
Label shutdowns outside transformer room (ventilation & f/o transfer pump shutdowns).
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Fire Fighting
Issued 20 March 1998 Resolved
Prove operation of SCR and generator room CO2 discharge warning lights.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 9 August 1985 Resolved
PROVIDE EMERGENCY LIGHTING AT LIFERAFT EMBARKATION AREAS. NVC4-78
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Deck/Cargo
Issued 9 August 1985 Resolved
MAKE THE 4 "P" TANKS AVAILABLE FOR AN INTERNAL INSPECTION BY A COAST GUARD INSPECTOR. NVIC 4-78
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Deck/Cargo
Issued 9 August 1985 Resolved
RENEW THE RELIEF VALVE ON THE 40 PSI BULK TANK. NVIC 4-78
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Unknown
Issued 14 June 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE TRANSWORLD 65, CG000082.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
INSTALL SAFETY DEVICES AROUND FIRE STATION #13 AND #14 TO PROTECT FROM DAMAGE.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Fire Fighting
Issued 14 June 1984 Resolved
RELOCATE FIRE STATION #14 HOSE RACK FOR EASY ACCESS.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
REPLACE BROKEN EMERGENCY LIGHT IN HALIBURTON ROOM.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 14 June 1984 Resolved
REPAIR OR REPLACE ALL LEAKING FIRE STATION VALVES.
Condition: Unknown
Due 14 June 1984
Resolved 14 June 1984
Unknown
Issued 16 May 1984 Resolved
PROVIDE SUITABLE CONTAINMENT FOR BOTH FUEL TAKE-ON MANIFOLDS.
Condition: Unknown
Due 16 May 1984
Resolved 16 May 1984
Unknown
Issued 16 May 1984 Resolved
PROVIDE FUEL HOSES FOR FUEL TAKE-ON MANIFOLDS THAT COMPLY WITH 33 CFR 154.500.
Condition: Unknown
Due 16 May 1984
Resolved 16 May 1984
Unknown
Issued 16 May 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE TRANSWORLD 65, CG000082.
Condition: Unknown
Due 16 May 1984
Resolved 16 May 1984
Fire Fighting
Issued 10 August 1983 Resolved
PROVIDE ONE (1) ADDITIONAL FIRE AXE FOR FIREMAN'S OUTFIT, AND LABEL BOTH WITH RIG NAME.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
REPAIR WIRING FOR PORT AND STARBOARD RUNNING LIGHTS.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Fire Fighting
Issued 10 August 1983 Resolved
REPAIR OR REPLACE COMBUSTIBLE GAS AND O2 INDICATORS FOR FIREMAN'S OUTFITS.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Lifesaving
Issued 10 August 1983 Resolved
SERVICE ALL FIVE (5) HYDROSTATIC RELEASES FOR INFLATABLE LIFERAFTS OR MAKE FLOAT FREE.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Navigation
Issued 10 August 1983 Resolved
MAKE OPERABLE STERN NAVIGATING LIGHT.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
PROVIDE EYS FITTINGS FOR HAZARDOUS LOCATION, AGITATOR MOTOR NUMBER 3.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATION THE JUNCTION BOX "T" FITTINGS LOCATED IN OVERHEAD ABOVE SHALE SHAKER AREA AND DRILL FLOOR AREA.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
PROPERLY BAND WIRING IN OVERHEAD OF SHALE SHAKER.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
REMOVE OR MAKE SUITABLE FOR HAZARDOUS LOCATION THE INTERCOM LOCATED IN AREAON PORT SIDE RAILING.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATION THE FOUR (4) NON-EXPLOSION PROOF BOXESLOCATED ON THE BULKHEAD BEHIND THE DRAWWORKS.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
REMOVE OR MAKE SUITABLE FOR HAZARDOUS LOCATIONS THE HORN OVER THE GAS DETECTOR ON THE DRILL FLOOR.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Documentation
Issued 10 August 1983 Resolved
SUBMIT HAZARDOUS LOCATION PLAN TO COAST GUARD MARINE INSPECTION OFFICER NEWORLEANS, LOUISIANA FOR APPROVAL.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATIONS THE WIRING TO THE TRIP TANK LOCATED ON THE DRILL FLOOR.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Navigation
Issued 10 August 1983 Resolved
PROVIDE SIDESCREEN FOR PORT AND STARBOARD RUNNING LIGHTS.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Unknown
Issued 10 August 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU TRANSWORLD 65, CG000082.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Fire Fighting
Issued 10 August 1983 Resolved
PROVIDE A GENERAL ALARM BELL ON STARBOARD SIDE, MAIN DECK, AT OR NEAR BASE OF CRANE.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
PROPERLY BAND WIRING LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Lifesaving
Issued 10 August 1983 Resolved
PROVIDE FOUR (4) PROJECTILES FOR LINE THROWING GUN.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Electrical
Issued 10 August 1983 Resolved
MAKE MUD MONITOR LEVEL ALARM SUITABLE FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Fire Fighting
Issued 19 January 1983 Resolved
OUTDATED FIRE CONTROL PLAN POSTED, NOT SHOWING LOCATION OF FIREMANS OUTFIT,AND SOME FIRE HOSE STATIONS.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983

Ownership record