Records from 1981 to 1999. Most recent: inspection, 30 April 1999.
Inspection history · 40
30 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792000
18 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799222
4 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125767
26 November 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 651293
25 November 1997
Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421423
11 November 1997
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1375211
10 November 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 124678
10 November 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 218826
19 March 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1103457
18 March 1997
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1383471
9 January 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435845
30 April 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082391
11 March 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077488
30 January 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416238
24 April 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 859758
2 March 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449781
27 January 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447320
31 December 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 831481
23 November 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376894
26 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 643631
22 February 1992
Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946076
9 December 1991
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1258340
15 October 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249487
5 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 933316
1 March 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928064
29 November 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905091
30 January 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241729
2 May 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893380
23 December 1988
COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034807
8 December 1988
Hull Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1209896
12 October 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197116
16 February 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332643
23 December 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003781
16 October 1985
Credit Drydock · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1299095
7 December 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283837
28 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283828
5 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281422
6 October 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1271108
6 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965263
23 September 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272567
Construction/Loadline
Issued 11 November 1997
Resolved
Make repairs to plating,stbd side, fm frames 52-68 per ref case.
Condition: Unknown
Due 13 November 1997
Resolved 30 December 1997
Accommodation/Occupational Safety
Issued 30 January 1996
Resolved
REMOVE BOW THRUSTER HEAD TANK FROM ACCOMODATION SPACE AS PER 46CFR56.50-60.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Documentation
Issued 30 January 1996
Resolved
SUBMIT CORRECTED AUTOMATED TEST PROCEDURES FOR APPROVAL AS PER NAVIC 1-78 CH1.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Deck/Cargo
Issued 29 November 1990
Resolved
AT NEXT CREDIT DRYDOCK MAKE P-TANKS DUST FREE AND GAS-FREE BY MARINE CHEMIST AND AVAILABLE FOR INTERNAL INSPECTION BY ATTENDING COAST GUARD INSPECTOR. CIDIG MEMO #15
Condition: Unknown
Due 29 November 1990
Resolved 29 November 1990
Electrical
Issued 29 November 1990
Resolved
SUBMIT AUTOMATION MAINTENANCE AND TEST PROCEDURES USED THIS INSPECTION TO [name withheld] FOR COAST GUARD APPROVAL.(3 COPIES)
Condition: Unknown
Due 29 November 1990
Resolved 29 November 1990
Documentation
Issued 23 December 1988
Resolved
PROVIDE AN ORGINAL SIGNED COAST GUARD APPROVED STABILITY LETTER AND POST INACCORDANCE WITH 46 CFR 97.11.
Condition: Unknown
Due 23 December 1988
Resolved 23 December 1988
Fire Fighting
Issued 23 December 1988
Resolved
PROVIDE INSTRUCTIONS FOR THE FIXED CO2 SYSTEM INSTALLED IN THE PAINT LOCKERWHICH MEET THE REQUIREMENTS OF 46 CFR 95.15-10(H).
Condition: Unknown
Due 23 December 1988
Resolved 23 December 1988
Unknown
Issued 28 November 1984
Resolved
PROVIDE A HAND SET FOR THE SOUND POWERED PHONE IN THE ENGINE ROOM.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Fire Fighting
Issued 28 November 1984
Resolved
MAKE REPAIRS TO VESSEL'S FIRE PUMP (INBOARD PORT PUMP IN THE ENGINE ROOM). PUMP PRESSURE IS ONLY 40 PSIG.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
PROVIDE A DEVIATION TABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
POST THE STABILITY LETTER UNDER GLASS IN PILOTHOUSE.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
REPAIR THE CONTROL AIR LOW PRESSURE ALARM.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
PROVIDE GUARDS AROUND THE PULLEYS AT THE FRONT OF THE MAIN ENGINES.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
PROVIDE 30 X 30 MESH FLAME SCREENS FOR THE FUEL OIL TANK VENTS.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
REPAIR THE STEERING GEAR FAILURE ALARM.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
PROVIDE A SIGN FOR GENERAL ALARM BELL IN THE ENGINE ROOM.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
PROVIDE THREE (3) CHAINS FOR THE OPEN BULKWORK AREA AT THE STERN.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984
Unknown
Issued 28 November 1984
Resolved
PERMANENTLY INSTALL THE WELDING MACHINE IN THE ENGINEROOM WITH A PROPER ELECTRICAL CABLE AND CIRCUIT BREAKER.
Condition: Unknown
Due 28 November 1984
Resolved 28 November 1984