Records from 1982 to 2015. Most recent: inspection, 13 November 2015.
Inspection history · 102
13 November 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762848
16 May 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4860183
31 January 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4235491
29 September 2011
Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4157187
8 September 2011
Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4139136
21 July 2011
Drydock Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4089034
23 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3543680
3 March 2009
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3435576
3 November 2008
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3361614
19 August 2008
Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3303016
20 December 2007
Annual Inspection · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3127321
1 July 2007
MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2976571
16 October 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2801802
8 September 2006
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2770667
8 March 2006
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2589440
2 June 2005
Deficiency Check · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2391712
20 May 2005
In-Service Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2364722
5 January 2004
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1975306
2 October 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1919465
23 April 2003
MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1782721
3 March 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1782171
23 February 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1748365
5 February 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1740209
22 December 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1740146
22 April 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1493180
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607000
2 December 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772688
2 August 2001
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1070764
18 July 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1068583
21 June 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1065413
13 June 2001
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1066333
19 April 2001
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1061963
13 March 2001
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1369926
2 October 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23712
27 September 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822447
11 July 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 819957
9 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818896
9 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818904
5 May 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 818155
25 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047708
6 March 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1472259
9 November 1999
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 808807
2 September 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1117893
4 August 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111228
7 July 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1092137
29 June 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455734
11 January 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 811434
6 January 1999
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1472745
9 October 1998
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 802121
6 August 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 796195
4 August 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1131212
7 July 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 794026
27 April 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1124686
8 April 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1123368
3 March 1998
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1125156
3 March 1998
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1375259
2 February 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 786249
10 November 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 124678
12 August 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 783198
16 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400606
28 February 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102229
16 January 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098414
10 January 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390522
12 December 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1092282
31 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165345
7 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 837283
17 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 959268
15 May 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414636
22 January 1996
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412909
11 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189886
17 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 874448
24 April 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 860817
12 January 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459917
22 April 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 856838
17 March 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463084
4 March 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429864
24 January 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1163008
21 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 842673
28 April 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415840
14 January 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425293
18 December 1992
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 960698
10 February 1992
Deficiency Check · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948904
4 December 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 62118
1 May 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216552
13 March 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1228228
11 February 1991
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1214851
24 January 1991
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1222110
22 January 1991
Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1221423
18 May 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1042211
13 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198154
12 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 894200
19 March 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1351051
28 April 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1040508
3 February 1987
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314775
16 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999129
1 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295302
26 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981936
30 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973135
18 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970464
27 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967023
25 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967107
19 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271120
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 May 2014
Resolved
Documentation shows lifeboat falls renewals six months after lifeboat weight tests with no weight test completed after falls renewal. Conduct 1.1x weight tests for both lifeboats and provide documentation to USCG [name withheld] for review and acceptance. Boats are available for emergency use only until the tests are completed and accepted. Cite 46 CFR 109.301(i).
Due 2 July 2014
Resolved 7 November 2014
Resolution: Documentation provided showing satisfactory completion.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 29 May 2014
Resolved
Lifeboat 2 has not been launched within the past 90-days. Launch boat and operate in the water within one week of weight test required above. Ensure that both boats are launched, disconnected and maneuvered in the water a minimum of every 90-days .Cite 46 CFR 109.213(c)(3).
Due 19 June 2014
Resolved 22 June 2014
Resolution: Documentation provided showing satisfactory completion.
Operations/Management › Drills/Instruction › Fire
Issued 29 May 2014
Resolved
Firefighting drill needed improvement. Increase training/drills over the next month to increase crew knowledge, interaction & proficiency. Address communications, smoke & fire boundaries, firefighter's equipment/dress & entry & attack methods utilized for different fires/spaces onbd. Ensure other personnel are aware of affected areas & remain clear of those areas. Cite 46 CFR 109.213(c), (f).
Due 29 June 2014
Resolved 18 June 2014
Resolution: Documentation provided showing satisfactory completion.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 29 May 2014
Resolved
Main Diesel Generator (MDG) #3 Rig Saver failed initial test and required maintenance to begin intermittent operation via remote actuation. Prove proper operation of all MDG Rig Savers via remote release and incorporate testing into routine preventive maintenance. Cite 46 CFR 107.270(d), (e).
Due 12 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 May 2014
Resolved
Piping/drain systems have had multiple repairs w/pin holes/seepage still present. Complete 3rd party survey of all piping systems throughout rig, including sanitary/drain piping. Note all leaks/seepage in piping, joints & fittings & temp repairs made by clad welding or installing doublers. Provide corrective action plan/timeline to affect repairs for review/acceptance. Cite 46 CFR 107.270(d), (e).
Due 7 December 2014
Resolved 5 December 2014
Resolution: Survey/repair proposal provided & accepted. Note several repairs will be completed during the next drydock/Special Survey due to inability to isolate specific systems while the rig is in operation.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Quantity of Foam-Forming Liquid
Issued 29 May 2014
Resolved
Refill Heli-Deck foam tank per Hiller report findings. Noted that foam is onboard. Cite 46 CFR 109.223.
Due 5 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Pressure
Issued 29 May 2014
Resolved
Loaner B-V extinguisher located on the port side of the Heli-Deck is low on charge. Provide replacement extinguisher in a serviceable/fully charged condition. Cite 46 CFR 108.493(a).
Due 12 June 2014
Resolved 18 June 2014
Resolution: Documentation provided showing satisfactory completion.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 May 2014
Resolved
The E-Gen fuel daytank was noted at 1/2capacity during the inspection. Ensure that the daytank is maintained at a full level at all times to give maximum/required run time. Cite 46 CFR 112.05-5(a).
Due 5 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 29 May 2014
Resolved
Noted that the 'A-Phase' of the 440v E-Buss has a complete ground. Also noted a complete ground on the 'A-Phase' of the 110V E-Buss panel in the Maintenance Office. Locate and correct the grounds in both Emergency circuits. Cite 46 CFR 107.270(d).
Due 5 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 29 May 2014
Resolved
One Bow Leg port side jacking gear set is currently removed for repair/overhaul. Provide Class report showing completed repairs, testing and acceptance. Cite 46 CFR 107.270(d), (e). Due 29Jun2014. CLEARED 27Jul14.
Due 29 June 2014
Resolved 27 July 2014
Resolution: Documentation provided showing satisfactory completion.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 29 May 2014
Resolved
The lower ladder section in the Stbd Leg is missing. This ladder serves as an egress to the water. Replace the missing section and ensure that it reaches to the waterline. Cite 46 CFR 108.540(h).
Due 29 June 2014
Resolved 7 July 2014
Resolution: Documentation provided showing satisfactory completion.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 29 May 2014
Resolved
The CO2 system release instructions for the E-Gen Room do not provide clear directions for operation of the system. Provide concise directions and valve labeling for the system. Cite 46 CFR 108.631(b). Due 12Jun2014
Due 12 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2014
Resolved
Noted severe wastage in the Mud Pit Room overhead plating along the Stbd bulkhead. Gauge the plating in a 6"x6" grid Pattern 18" out from the Stbd bulkhead for the entire length. Provide report for review along with repair proposal for areas below wastage limit. Cite 46 CFR 108.113. Due 29Jun2014. Extended to 07Dec on 07Nov by EES.
Due 7 December 2014
Resolved 5 December 2014
Resolution: Documentation provided showing satisfactory completion.
Engineering › Bilge Water Management System › Piping
Issued 29 May 2014
Resolved
Clear sediment and debris from both Sack Room bilge wells. Ensure all bilge wells are maintained in a clear condition and have the proper grating/screens installed. Cite 46 CFR 107.270(d), (e).
Due 12 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2014
Resolved
Stbd Leg MCC Room overhead is holed and allowing water intrusion over electrical panels, Crop & renew wasted overhead plating and ensure unused cable transits are plugged. Cite 46 CFR 108.113, 46 CFR 111.01-3(a).
Due 12 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Documentation › Logs/Records › Oil Record Book
Issued 29 May 2014
Resolved
The Oil Record Book (ORB) is being maintained incorrectly with codes for both Part I and Part II operations. There are no records of bunkering or disposal of lube oil within the last year. Maintain the ORB in accordance with instruction for Machinery Space Operations (the only section that applies to the MODU). Cite MARPOL I/17.
Due 5 June 2014
Resolved 5 June 2014
Resolution: Documentation provided showing satisfactory completion.
Lifesaving › Inflatable Liferafts › Float Free
Issued 29 May 2014
Resolved
Float-free arrangement is currently installed below the Heli-Deck overhang on both sides. Overhang presents likelihood that rafts could become obstructed/entrapped in a float-free situation. Provide proposal to re-locate the liferafts to unobstructed locations to facilitate an unobstructed float-free release. Cite 46 CFR 108.530(c)(7). Due 29Jun2014. Worked through multiple submittals.
Due 29 June 2014
Resolved 12 November 2014
Resolution: Documentation provided showing satisfactory completion. Liferafts were relocated to the lifeboat decks/muster areas.
Accommodation/Occupational Safety › Ventilation › General
Issued 29 May 2014
Resolved
General sanitary conditions of the accommodations are unsatisfactory. Improve general cleanliness of the berthing rooms and the heads. Remove mold present in lower passageways, overheads and ventilation systems. Cite 46 CFR 109.203(a).
Due 29 June 2014
Resolved 18 June 2014
Resolution: Documentation provided showing satisfactory completion.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 May 2014
Resolved
Emergency Diesel Generator (EDG) overspeed was found to be inoperative. Prove proper operation of the overspeed an ensure crew is familiar with EDG safety features, modes of operation and testing methods. Note: Overspeed was adjusted,/verified 29May14. Cite 46 CFR 112.50-1(g).
Due 12 June 2014
Resolved 20 June 2014
Resolution: Documentation provided showing satisfactory completion.
Lifesaving › Lifeboat › Propulsion Engine
Issued 21 July 2011
Resolved
Provide CG approval letter for the lifeboat second means of starting hydraulic system installed during the last yard period.
Due 13 October 2011
Resolved 27 October 2011
Resolution: Received CG approval letter for the lifeboat second means of starting hydraulic system installed during the last yard period.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 July 2011
Resolved
Review, walk and resubmit fire control plan for approval.
Action required: 705 - Other - as specified
Due 8 September 2011
Resolved 13 September 2011
Resolution: Approved fire control plan.
Construction/Loadline › Hull › Hull Plating
Issued 3 March 2009
Resolved
Complete UWILD (Pase II) no later than 02 Sept 2009 To the satisfaction of the attending ABS Surveyor or USCG inspector.
Due 2 February 2010
Resolved 3 February 2010
Resolution: Received satisfactory documentation (ABS Survey Report dated 02Feb10) showing the completion of SEILOD Phase II.
Construction/Loadline › Hull › Hull Plating
Issued 3 November 2008
Resolved
Complete UWILD (Phase II) no later than 3 Mar 2009 to the satisfaction of the attending ABS surveyor or USCG inspector.
Due 2 September 2009
Resolved 3 March 2009
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 1 July 2007
Resolved
Prove 100% water spray coverage on all three lifeboats utilizing required modification kits.
Due 1 August 2007
Resolved 1 August 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 1 July 2007
Resolved
Prove installation of paint locker CO2 system (full bottle).
Due 1 August 2007
Resolved 1 August 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 July 2007
Resolved
Provide means to ensure oil does not enter the sea from the settling/separator tank located under the rig floor.
Due 1 August 2007
Resolved 1 August 2007
Electrical › Electric Generation Source (service) › Ground Detection
Issued 2 June 2005
Resolved
Prove correction of ground fault indicator.
Due 2 July 2005
Resolved 2 June 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 June 2005
Resolved
Provide emergency lights at muster station that illuminate in a timely fashion.
Due 2 July 2005
Resolved 4 June 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 June 2005
Resolved
Mark all emergency lights with an "E".
Due 2 July 2005
Resolved 4 June 2005
Electrical › Electric Supply System (service) › Cable
Issued 2 June 2005
Resolved
Remove excess wiring at drill floor.
Due 2 July 2005
Resolved 4 June 2005
Electrical › Electric Generation Source (emergency) › Conductor
Issued 2 June 2005
Resolved
Prove emergency generator high water alarm utilizing a thermal function check.
Due 2 July 2005
Resolved 27 June 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 June 2005
Resolved
Replace all life ring retro-reflective material. Ensure retro-reflective material is not stenciled with paint.
Due 2 July 2005
Resolved 4 June 2005
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 2 June 2005
Resolved
Replace water pump in #3 lifeboat and function check water spray system.
Due 2 July 2005
Resolved 4 June 2005
Fire Fighting › Self-contained Breathing Apparatus › Facepiece
Issued 2 June 2005
Resolved
Repair or replace SCBA diaphram which is stuck on purge bypass.
Due 2 July 2005
Resolved 4 June 2005
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 2 June 2005
Resolved
Prove Coast Guard OCMI approval of Operating Manual.
Due 2 July 2005
Resolved 4 June 2005
Construction/Loadline › Hull › Bottom Plating
Issued 5 January 2004
Resolved
Complete phase II (Uwild) and make available for entry tanks 3C and 5C to the satisfaction of the attending ABS surveyor or Coast Guard inspector. LEGACY COMPONENT DESC: Underwater Body
Due 8 March 2004
Resolved 3 June 2005
Resolution: Drydocking survey completed by ABS.
Fire Fighting › Fire Pumps
Issued 23 April 2003
Resolved
Conduct repairs to water leak on discharge side of Firepump. LEGACY COMPONENT DESC: Discharge Line
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 28 April 2003
Lifesaving
Issued 13 March 2001
Resolved
Demonstrate fire and abandon rig drills to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Documentation
Issued 13 March 2001
Resolved
Provide approved Fire Safety Plan.
Condition: Unknown
Due 13 March 2001
Resolved 13 March 2001
Lifesaving
Issued 6 March 2000
Resolved
CONDUCT INTERNAL EXAMINATION OF BULK TANKS AND AIR RECEIVERS IN THE PRESENSE OF A MARINE INSPECTOR.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Lifesaving
Issued 29 June 1999
Resolved
SEPARATE WORK VESTS FROM LIFE VESTS ABOARD RIG.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Lifesaving
Issued 29 June 1999
Resolved
INSTALL ADDITIONAL E-LIGHTING IN MACHINERY ROOM & ACCOMMODATION SPACES AS NEEDED FOR EMERGENCY EGRESS.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Lifesaving
Issued 29 June 1999
Resolved
LABEL ALL CONTROLS & SWITCHES ABOARD RIG.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Electrical
Issued 29 June 1999
Resolved
REPLACE CRACKED OVERHEAD LIGHT ON DRILL FLOOR.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Electrical
Issued 29 June 1999
Resolved
RESOLVE GROUNDING PROBLEM ON 120V CIRCUIT IN SCR ROOM.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Electrical
Issued 29 June 1999
Resolved
REPLACE FIBERGLASS CABLE TRAYS W/METAL TYPE & REPLACE WORN CABLE AS NEEDED IN SHALE SHAKER AREA.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 6 January 1999
Resolved
PREP KNIFE EDGE AND INSURE PROPER SEAL OF WTD ON PAINT LOCKER.
Condition: Unknown
Due 6 February 1999
Resolved 13 January 1999
Lifesaving
Issued 6 January 1999
Resolved
REMOVE BLOCKAGE OF NATURAL VENT IWO OUTBOARD SIDE OF PAINT LOCKER.
Condition: Unknown
Due 6 February 1999
Resolved 13 January 1999
Electrical
Issued 6 January 1999
Resolved
REPLACE EXPLOSION PROOF JUNCTION BOX IWO DRILLERS CONSOLE, LEFT LOWER CORNER.
Condition: Unknown
Due 6 February 1999
Resolved 13 January 1999
Fire Fighting
Issued 6 January 1999
Resolved
TEST AND PROVIDE REPORT OF ALL SMOKE DETECTORS THROUGH OUT MODU TO GALMS OCMI.
Condition: Unknown
Due 6 February 1999
Resolved 13 January 1999
Construction/Loadline
Issued 3 March 1998
Resolved
RENEW AS ORIGINAL SOUNDING TUBE IN TANK # 4 STARBOARD AFT._x001C_
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 3 March 1998
Resolved
RENEW AS ORIGINAL WASTAGE TO SWASH BULKHEAD FOUR FOOT STIFFENERS IN FORWARDTWO BAYS IN # 3 DRILLWATER CENTERLINE TANK. ALL MEMBERS THROUGHOUT ARE WASTED AND REQUIRE REPAIR 4 FOOTS.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Accommodation/Occupational Safety
Issued 3 March 1998
Resolved
REPAIR WASTED HANDRAIL ON NO 2 LIFEBOAT STATION.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Lifesaving
Issued 3 March 1998
Resolved
REPLACE/RECHARGE EXTRA SCBA BOTTLE IN FIREMANS LOCKER MAIN DECK PORT SIDE.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Fire Fighting
Issued 3 March 1998
Resolved
REPAIR WATER LEAK ON FIRE STATION NO 11.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Electrical
Issued 3 March 1998
Resolved
REATTACH ELECTRICAL SWITCH BOX FOR WALK-IN COOLER ALARM TO BULKHEAD.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Lifesaving
Issued 3 March 1998
Resolved
REPLACE CRACKED AFT WINDOW ON NO 3 LIFEBOAT.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Lifesaving
Issued 3 March 1998
Resolved
ADJUST LIMIT SWITCH ON NO 1 LIFEBOAT TO STOP LIFEBOAT BEFORE HITTING PLATFORM. 12" RULE APPLIES.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Lifesaving
Issued 3 March 1998
Resolved
SECURE OIL LEAK ON OIL FILTER FOR NO 1 LIFEBOAT.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Fire Fighting
Issued 3 March 1998
Resolved
REPAIR/REPLACE NOZZLE ON FIRE STATION NO 6 DUE TO HANDLE FROZEN.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Fire Fighting
Issued 3 March 1998
Resolved
CROP AND RENEW WASTED FIREMAIN ABOVE # 2 FIRE PUMP.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Unknown
Issued 3 March 1998
Resolved
COMPLETE PHASE II OF SEILOD AND SUBMIT DIVERS AND ABS REPORT TO OCMI.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 3 March 1998
Resolved
RENEW AS ORIGINAL SOUNDING TUBE IN TANK # 5 STARBOARD AFT.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Deck/Cargo
Issued 3 March 1998
Resolved
RENEW AS ORIGIONAL VENT LINE TO # 5 PT AFT TANK, ON MAIN DECK, ADJACENT TO JACKHOUSE.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 3 March 1998
Resolved
RENEW AS ORIGINAL UNDERDECK STRENGTH MEMBER, WHERE DEFLECTED/WASTED IN WAY OF JACKING PAD, TANK # 5 PT AFT.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Construction/Loadline
Issued 3 March 1998
Resolved
RENEW AS ORIGIONAL WASTED SIDESHELL LONGITUDINALS, STIFFENERS, ALONG ENTIRELENGTH OF OUTBOARD SIDESHELL IN TANK # 5 AFT, 4 FROM BOTTOM OF DECK.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Lifesaving
Issued 3 March 1998
Resolved
REPAIR/COVER HOLE IN CONSOLE OF NO 2 LIFEBOAT.
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Lifesaving
Issued 3 March 1998
Resolved
ATTACH ELECTRICAL TERMINAL INSIDE ENGINE COVER TO CONSOLE IN NO 2 LIFEBOAT
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Lifesaving
Issued 3 March 1998
Resolved
SECURE FIRE EXTINGUISHERS IN BRACKETS IN NO 2 LIFEBOAT
Condition: Unknown
Due 3 March 1998
Resolved 11 March 1998
Documentation
Issued 16 July 1997
Resolved
SUBMIT REVISED FIRE CONTROL AND LIFESAVING EQUIPMENT PLAN TO COGNIZANT OCMIFOR APPROVAL. REVISED FIRE CONTROL AND LIFESAVING EQUIPMENT PLAN MUST INCLUDE INSTALLATION OF TEMPORARY QUARTERS UNIT, ADDITION OF LIFEBOAT AND ADDITION OF GENERATOR ROOM FIXED CO2 SYSTEM.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Lifesaving
Issued 16 July 1997
Resolved
COMPLY WITH OPERATIONAL REQUIREMENTS OF 46 CFR 109, 1996 EDITION.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Lifesaving
Issued 16 July 1997
Resolved
PROVE PROPER INSTALLATION AND OUTFITTING OF NEW LIFEBOAT SYSTEM. NEW LIFEBOAT INSTALLATION MUST MEET THE DESIGN AND EQUIPMENT REQUIREMENTS OF 46CFR 108, 1996 EDITION.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Construction/Loadline
Issued 16 July 1997
Resolved
MAKE WATERTIGHT DOORS LEADING FROM GENERATOR ROOM, WHICH IS PROTECTED BY A FIXED CO2 SYSTEM, OPEN OUTWARD.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Construction/Loadline
Issued 15 May 1996
Resolved
SUBMIT WRITTEN REPORT AND VIDEOTAPE OF UNDERWATER SPUD CAN EXAM TO OCMI.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Construction/Loadline
Issued 15 May 1996
Resolved
SUBMIT REPAIR PROPOSAL FOR SPUD CANS TO OCMI.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Construction/Loadline
Issued 22 January 1996
Resolved
CONDUCT SPUD CAN INSPECTION PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Construction/Loadline
Issued 22 January 1996
Resolved
CONTACT OCMI AND MAKE ARRANGEMENTS FOR CG INSPECTOR TO EXAMINE COMPLETED HULL REPAIRS PER ABS SURVEY OF 21JAN96.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Lifesaving
Issued 22 January 1996
Resolved
REPLACE OUT-DATED LIGHTS ON SURVIVAL SUITS.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Lifesaving
Issued 22 January 1996
Resolved
INSTALL CAGES ON BRAKE TORQUE LADDERS IN LEG WELLS.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Lifesaving
Issued 22 January 1996
Resolved
REPLACE WORN-OUT RETROFLECTIVE TAPE ON SURVIVAL SUITS.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Accommodation/Occupational Safety
Issued 22 January 1996
Resolved
INSTALL GENERAL ALARM BELL IN TEMPORARY QUARTERS BUILDING.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Accommodation/Occupational Safety
Issued 22 January 1996
Resolved
INSTALL COVERS ON BUNK LIGHTS WHERE NEEDED IN QUARTERS.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Navigation
Issued 22 January 1996
Resolved
REPAIR STERN LIGHT.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Electrical
Issued 22 January 1996
Resolved
PERFORM SEMI-ANNUAL TESTING OF EMERGENCY LIGHTING AND POWER SYSTEMS IAW 46 CFR 109.211.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Electrical
Issued 22 January 1996
Resolved
PROPERLY SECURE ALL WIRING ON DRILL FLOOR, DERRICK, AND IN PUMP ROOM.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Lifesaving
Issued 22 January 1996
Resolved
SERVICE ZIPPERS ON SURVIVAL SUITS.
Condition: Unknown
Due 22 January 1996
Resolved 22 January 1996
Accommodation/Occupational Safety
Issued 12 January 1995
Resolved
REPAIR WASTED DRAIN LINE ABOVE #4 P-TANK
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Documentation
Issued 12 January 1995
Resolved
MAKE ENTRY TO OPERATIONS MANUAL DETAILING PROPER OPERATION OF VENTILATION SYSTEM FOR PIT ROOM.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Accommodation/Occupational Safety
Issued 12 January 1995
Resolved
PERFORM HYDROTEST ON AIR RECEIVER ON DRILL FLOOR TO 1.25X MAWP.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Electrical
Issued 12 January 1995
Resolved
MAKE STARBOARD DOOR TO PIT ROOM CLOSE GAS TIGHT.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Electrical
Issued 12 January 1995
Resolved
REHANG ELECTRICAL CABLES IN PIT ROOM AS NEEDED.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Lifesaving
Issued 4 March 1994
Resolved
PLACE RETROREFLECTIVE TAPE ON ALL RING BUOYS.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
REPACK NIELSEN ELECTRICAL CONDUIT ON MAIN DECK BY THE SHAKER.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Lifesaving
Issued 4 March 1994
Resolved
PROVIDE RATIONS FOR 5 PERSONS IN THE NUMBER 2 LIFE CAPSULE.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Lifesaving
Issued 4 March 1994
Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING FOR #2 LIFERAFT.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Electrical
Issued 4 March 1994
Resolved
REPLACE NON APPROVED FITTING ON FWD BULKHEAD OVER #3 TANK IN MUD PIT ROOM WITH AN APPROVED EXPLOSION PROOF FITTING.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Lifesaving
Issued 4 March 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
REPLACE BATTERY IN EMERGENCY LIGHT IN SCR ROOM.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Lifesaving
Issued 4 March 1994
Resolved
REPLACE EXISTING AIR FITTINGS ON POTABLE WATER TANKS (3) WITH SCHRADER FITTINGS (BICYCLE FITTING) OR THE EQUIVILENST SO THAT NO FIXED CONNECTION CAN BE MADE TO THE AIR SYSTEMS.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Fire Fighting
Issued 4 March 1994
Resolved
PROVIDE EVIDENCE OF ANNUAL SERVICING FOR ALL FIXED FIRE FIGHTING SYSTEMS.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
REPLACE GLOBE AND GUARD ON LIGHT ON STBD CRANE HEAD.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
PROVIDE NEW BATTERY COVER FOR BATTERIES IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Lifesaving
Issued 4 March 1994
Resolved
LABEL ALL LIFEJACKETS WITH THE VESSEL'S NAME.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Accommodation/Occupational Safety
Issued 4 March 1994
Resolved
LABEL ALL ESCAPE HATCHES ON MAIN DECK "EMERGENCY ESCAPE HATCH, KEEP CLEAR."REPAIR DOG MECHANISM ON THE ESCAPE FROM THE HALIBURTON ROOM.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Fire Fighting
Issued 4 March 1994
Resolved
RELABEL NEW CO2 SYSTEM CORRECTLY AND CLEARLY FOR LOCAL ACTIVATION. RAISE ALL BOTTLES 2 INCHES OFF DECK.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
PROVE PROPER OPERATION OF STANDBY GENERATOR.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Lifesaving
Issued 4 March 1994
Resolved
PUT SIGN BY GENERAL ALARM BELL IN SCR ROOM. (WHEN ALARM SOUNDS, GO TO YOURSTATION)
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Construction/Loadline
Issued 4 March 1994
Resolved
REPAIR THE STBD WATER TIGHT DOOR, THIRD LEVEL BY THE COMPANY MAN'S ROOM.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
PERMANENTLY WIRE DUMP VALVES ON AIR DRYER.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Accommodation/Occupational Safety
Issued 4 March 1994
Resolved
REMOVE OLD WATERMAKER DISCHARGE LINE ON WATER TOWER SLEEVE IN WATERMAKER ROOM AND PROPERLY SEAL.
Condition: Unknown
Due 4 April 1994
Resolved 28 March 1994
Construction/Loadline
Issued 28 April 1993
Resolved
CONDUCT LEG TO CAN CONNECTIONINSPECTION ON BOW, PORT AND STBD LEG AT NEXT RIG MOVE BUT NOT LATER THAN COMPLIANCE DATE INTHE PRESENCE OF A COAST GUARDMARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 28 April 1993
Resolved 28 April 1993
Engineering
Issued 14 January 1993
Resolved
PROVIDE DEADMAN NOZZLE ON FUELING HASE IN CEMENT UNIT ROOM. DESIGNATE AS FUELING AREA.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Electrical
Issued 14 January 1993
Resolved
POUR EYS FITTING ON SHALE SHAKER MOTORS WITH APPROVED FILLER._x001C_
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Engineering
Issued 14 January 1993
Resolved
RENEW LUBE OIL TANK SIGHT GLASSES WITH HEAT RESISTANT MATERIAL, PROTECTED, AND SELF CLOSING DEVICES AT BOTH ENDS.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Lifesaving
Issued 14 January 1993
Resolved
PROVE PROPER OPERATION OF GENERAL ALARMS IS FOLLOWS; PORT JACK HOUSE, TWO (2) IN ENGINE ROOM, MUD PIT ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Documentation
Issued 14 January 1993
Resolved
UPDATE/CORRECT VESSELS CERTIFICATE OF FINANCIAL RESPONSIBILITY TO REFLECT VESSELS NAME CHANGE.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Accommodation/Occupational Safety
Issued 14 January 1993
Resolved
RENEW RELIEF VALVE ON HOT WATER HEATER (<=100 PSI AND <=210 DEGREES) OR MAKE HOT WATER AVAILABLE FOR INTERNAL INSPECTION AT EACH COI INSPECTION.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Documentation
Issued 22 January 1991
Resolved
Provide updated, ABS/USCG approved Classified Location Plan on board the vessel. 46CFR110.25-1_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Fire Fighting
Issued 22 January 1991
Resolved
Provide test results for the firefighting foam sample taken on 19Dec90._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Documentation
Issued 22 January 1991
Resolved
Provide updated, USCG approved Construction Portfolio on board the vessel._x001C_46CFR107.305_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Lifesaving
Issued 22 January 1991
Resolved
Provide two floating orange smoke distress signals for each lifeboat._x001C_ 46CFR94.20-15_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Documentation
Issued 22 January 1991
Resolved
Provide updated, USCG approved Operations Manual on board the vessel. _x001C_ 46CFR109.121_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Accommodation/Occupational Safety
Issued 22 January 1991
Resolved
Install ventilation and vent failure alarm for the aft, starboard jack house and make the entrance door gas-tight, self closing, opening into the jack house. Until completed, all interior electrical circuits must be de- energized and dis-connected from their sources and the entrance door kept
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Navigation
Issued 22 January 1991
Resolved
Replace the broken aft, starboard obstruction light fixture and lens._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Lifesaving
Issued 22 January 1991
Resolved
Conduct fire drill, abandon vessel drill, and operational test of the starboard (#1) lifeboat prior to departure from the Port of Brownsville, Texas._x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Documentation
Issued 22 January 1991
Resolved
Provide updated, USCG approved Fire Control/Lifesaving Plans on board the vessel. 46CFR107.305_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Fire Fighting
Issued 19 March 1989
Resolved
PROVIDE TWO (02) PROPERLY OPERATING, CALIBRATED OXYGEN/EXPLOSIVE METERS AS REQUIRED BY 46CFR108.497.
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Electrical
Issued 19 March 1989
Resolved
PROVIDE REMOTE SHUTDOWNS FOR FUEL OIL PURIFIER AS REQUIRED BY 46CFR58.01-25 AND 111.103-9.
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Navigation
Issued 19 March 1989
Resolved
PROVIDE UL-APPROVED NAVIGATION LIGHTS AND BULBS FOR PORT AND STARBOARD RUNNING LIGHTS AS REQUIRED BY 46CFR111.75-17.
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Lifesaving
Issued 19 March 1989
Resolved
PROVIDE TWO (02) SEA PAINTERS FOR NO. 2 (STARBOARD) LIFE CAPSULE AS REQUIRED BY 46CFR108.503 AND 94.20-10.
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Lifesaving
Issued 19 March 1989
Resolved
PROVIDE TWO (02) SEA PAINTERS FOR NO. 1 (PORT) LIFE CAPSULE AS REQUIRED BY 46CFR108.503 AND 94.20-10.
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Electrical
Issued 19 March 1989
Resolved
REMOVE THE "FLO-SHO" ROTARY PRINTER FROM THE DRILL FLOOR OR PROVE SAFE FOR OPERATION IN A CLASS I, DIVISION II HAZARDOUS LOCATION AS REQUIRED BY 46CFR111.105.
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Fire Fighting
Issued 19 March 1989
Resolved
PROVIDE FIREMAIN INTERNATIONAL SHORE CONNECTION FOR INSTALLATION AS REQUIRED BY 46CFR108.427.
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Lifesaving
Issued 19 March 1989
Resolved
PROVIDE TWO (02) SMOKE FLOATS FOR RING BOUYS AS REQUIRED BY 46CFR108.515(D)
Condition: Unknown
Due 19 March 1989
Resolved 19 March 1989
Unknown
Issued 1 April 1986
Resolved
REPLACE DRILLER'S CONSOLE PANEL AND MAKE PURGE AIR SYSTEM OPERATIVE IN ACCORDANCE WITH NFPA STANDARD 496.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Unknown
Issued 1 April 1986
Resolved
PROVIDE ABOARD THE RIG AN APPROVED FIRE CONTROL AND LIFESAVING PLAN.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Unknown
Issued 1 April 1986
Resolved
HAVE ABS CONDUCT THE ANNUAL LOADLINE SURVEY AND SUBMIT GUIDENCE TO [name withheld], LA.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Unknown
Issued 1 April 1986
Resolved
HAVE ALL MSA BREATHING APPARATUS BOTTLES HYDROTESTED.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Unknown
Issued 26 March 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, DIAMOND M. NUGGET, DN573286
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Unknown
Issued 26 March 1985
Resolved
COMPLETE THE EXAMINATION OF THE SPUD CANS AT THE NEXT RIG MOVE. PROVIDE OFFICER IN CHARGE MARINE INSPECTION OFFICE NEW ORLEANS COPIES OF THE PHOTOS OF THE CRACKS ON THE SPUD CANS. 46 CFR 107.261.
Condition: Unknown
Due 26 March 1985
Resolved 26 March 1985
Construction/Loadline
Issued 30 May 1984
Resolved
NON-SKID THE ENTIRE HELIPORT DECK. SEE 46CFR108.235
Condition: Unknown
Due 30 May 1984
Resolved 30 May 1984
Unknown
Issued 30 May 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE MODU DIAMOND M. NUGGET, DN573286
Condition: Unknown
Due 30 May 1984
Resolved 30 May 1984
Unknown
Issued 27 May 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL DIAMOND M. NUGGET, DN573286
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Fire Fighting
Issued 27 May 1983
Resolved
PROVIDE OXYGEN AND EXPLOSIVE VAPOR METERS FOR BOTH FIREMEN'S OUTFITS.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Electrical
Issued 27 May 1983
Resolved
REMOVE SPLICE FROM CABLE ON DRAWWORKS "B" MOTOR KILL SWITCH ON DRILL FLOOR.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Electrical
Issued 27 May 1983
Resolved
PROVIDE ALARMS OR FLOW INDICATORS OR PROVIDE FOR EQUIPMENT SHUTDOWN ON ALL PURGED SYSTEMS ON DRILL FLOOR.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Fire Fighting
Issued 27 May 1983
Resolved
PROVIDE MARINE BRACKETS FOR FIRE EXTINQUISHERS WHERE MISSING.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Documentation
Issued 27 May 1983
Resolved
HAVE ANNUAL LOADLINE SURVEY CONDUCTED BY ABS.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Documentation
Issued 27 May 1983
Resolved
HAVE ABS OR ICGB CONDUCT ANNUAL INSPECTION OF CRANES.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Fire Fighting
Issued 27 May 1983
Resolved
MAKE GENERAL ALARM BELL IN AQUA CHEM ROOM OPERATIONAL.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Engineering
Issued 27 May 1983
Resolved
FIX HYDRAULIC AND COOLING WATER LEAKS IN PORT THRUSTER ROOM.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Electrical
Issued 27 May 1983
Resolved
PROPERLY MOUNT JUNCTION BOX AT ACCESS TRUNK TO PORT THRUSTER ROOM.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Lifesaving
Issued 27 May 1983
Resolved
PROVIDE SEVEN (7) ADDITIONAL TYPE "I" LIFEJACKETS PRIOR TO 4 JUNE 1983.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Electrical
Issued 27 May 1983
Resolved
MAKE VENTILATION FAILURE ALARM FOR MUD PIT ROOM OPERATIONAL.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Electrical
Issued 27 May 1983
Resolved
PROVIDE EMERGENCY LIGHTING TO ILLUMINATE CAPSULES AND RAFTS FROM STOWED LOCATION TO THE WATER.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Fire Fighting
Issued 27 May 1983
Resolved
PROVIDE A FIRE STATION ON THE DRILL FLOOR.
Condition: Unknown
Due 27 May 1983
Resolved 27 May 1983
Lifesaving
Issued 19 February 1982
Resolved
REPAIR OR REPLACE AFTER LIMIT SWITCH FOR STARBOARD CAPSULE.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Unknown
Issued 19 February 1982
Resolved
REMOVE SCHLUMBERGER GENERATOR FROM HAZARDOUS AREA.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Construction/Loadline
Issued 19 February 1982
Resolved
REPAIR DOOR CLOSURE DEVICES ON MUD PIT DOORS.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
PROVIDE EYS SEAL FOR SWITCH OUTSIDE STARBOARD MUD PIT DOOR.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
REMOVE OR REPLACE NON-EXPLOSION PROOF FLOURESCENT LIGHT NEAR STARBOARD MUD PIT DOOR.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
REPLACE MUD PIT VENTILATION FAILURE ALARM.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Fire Fighting
Issued 19 February 1982
Resolved
PROVIDE BRACKETS AND NAME PLATES FOR FIRE EXTINGUISHERS IN BOTH CRANES 46 CFR 108.491.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Deck/Cargo
Issued 19 February 1982
Resolved
PROVIDE INSULATION OR GUARD AROUND HALLIBURTON EXHAUSTS ON MAIN DECK NVC 4-78, 3(D)
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Deck/Cargo
Issued 19 February 1982
Resolved
PROVIDE DEADMAN NOZZLES FOR FUEL OIL TRANSFER HOSES WHICH SERVICE SCHLUMBERGER UNIT, BOTH CRANES AND HALLIBURTON UNIT 46 CFR 109.537.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Unknown
Issued 19 February 1982
Resolved
INSTALL VALVES AND CLAMPS AT TOP AND BOTTOM OF SIGHT GLASSES FOR MAIN DECK LUBE OIL TANKS NVC 4-78 3D.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
PROVIDE ADDITIONAL GENERAL ALARM BELL FOR COVERAGE OF SHALE SHAKER AREA NVC 4-78 3D.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Unknown
Issued 19 February 1982
Resolved
REPLACE RUPTURE DISCS IN SIX BULK CHEMICAL TANKS WITH DISC MAXIMUM 40 PSI SETTING NVC 4-78 3D(11).
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
PROVIDE GROUND DETECTION LAMPS AND COVERS FOR LIGHTING LOAD CENTER
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
REPAIR EMERGENCY LOAD AUTOMATIC TRANSFER SWITCH.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
PROVIDE LEAD OR FIBERGLASS LINING FOR OBSTRUCTION LIGHT BATTERY BOX.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
PROVIDE GLOBE GUARDS FOR LIGHTS IN LINEN LOCKER, 2ND DECK, SUPPLY LOCKER 3RD DECK, LINEN LOCKER 3RD DECK ELECTRIC SHOP, STBD THRUSTER ACCESS TRUNK.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
RENEW WIRING TO LIGHT AT PORT AFT CORNER OF DRILL SLOT.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
REPLACE SPLICED CABLE TO FLOURESCENT LIGHT BY SHALE SHAKER.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
REPLACE NON-EXPLOSION PROOF RECEPTICALS BY SHALE SHAKER.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
REPLACE NON-EXPLOSION PROOF JUNCTION BOXES AND PROVIDE EYS SEALS WHERE MISSING AROUND SHALE SHAKER.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
PROVIDE AIR PURGING FOR FLO-SHO/MUD FLOW METER AND RECORDER. MUD SKETEER, AND DRILLERE CONSOLE IN ACCORDANCE WITH NFPA 496.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Electrical
Issued 19 February 1982
Resolved
REPLACE SPLICED WIRING FOR ROTARY TACHOMETER GENERATOR AND PROVIDE EYS SEAL.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Documentation
Issued 19 February 1982
Resolved
PROVIDE OPERATING MANUAL APPROVED IN ACCORDANCE WITH 46 CFR 109.121.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Documentation
Issued 19 February 1982
Resolved
PROVIDE HAZARDOUS LOCATION PLAN ABOARD VESSEL APPROVED BY [name withheld] 46 CFR 111.10-5.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Unknown
Issued 19 February 1982
Resolved
PROVIDE A MINIMUM OF 2 ABLE AND 1 ORDINARY SEAMAN ON EACH CREW 46 CFR 109.323.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Fire Fighting
Issued 19 February 1982
Resolved
SERVICE FIXED AND SEMI PORTABLE FIRE FIGHTING EQUIPMENT BY AN APPROVED MANUFACTURERS REPRESENTATIVE 46 CFR 107.235.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Lifesaving
Issued 19 February 1982
Resolved
PROVIDE 1500' AUXILIARY LINE FOR LINE THROWING GUN 46 CFR 160.040.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Navigation
Issued 19 February 1982
Resolved
REPOSITION SIDE LIGHTS TO PROVIDE ADEQUATE VISIBILITY 33 CFR 87.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Fire Fighting
Issued 19 February 1982
Resolved
PROVIDE FIREMANS OUTFITS THAT COMPLY WITH 46 CFR 108.497 AND STOW IN ACCOR-DANCE WITH APPROVED LIFESAVING AND FIRE FIGHTING PLAN.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Lifesaving
Issued 19 February 1982
Resolved
PROVIDE EQUIPMENT FOR LIFESAVING CAPSULES
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Fire Fighting
Issued 19 February 1982
Resolved
PROVIDE ONE ADDITIONAL B-V FIRE EXTINGUISHER FOR HELICOPTER DECK ACCESS 46 CFR 108.493.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Lifesaving
Issued 19 February 1982
Resolved
PROVIDE ANNUAL SERVICING FOR LIFERAFTS 46 CFR 109.219.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Lifesaving
Issued 19 February 1982
Resolved
PROVIDE ANNUAL SERVICING OR RENEW HYDROSTATIC RELEASES ON ALL LIFERAFTS OR MAKE THEM FLOAT FREE TYPE.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Deck/Cargo
Issued 19 February 1982
Resolved
PROVIDE LOAD CHART IN PORT CRANE CAB 46 CFR 109.525
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Fire Fighting
Issued 19 February 1982
Resolved
PROVIDE APPROVED PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH APPROVED FIRE FIGHTING PLAN.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982
Fire Fighting
Issued 19 February 1982
Resolved
PROVIDE SPARE FIRE EXTINGUISHER OR CHARGED 46 CFR 108.491.
Condition: Unknown
Due 19 February 1982
Resolved 19 February 1982