PEGGY LEA

PEGGY LEA is a 1981 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1981, most recently in August 2016, along with 80 deficiencies — 1 with no resolution recorded —, 1 operational control and 2 casualty investigations between 2005 and 2015.

Records from 1981 to 2016. Most recent: inspection, 3 August 2016.

Built
1981
Last inspected
3 August 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ3448
Flag
UNITED STATES
367502310 (licence lapsed)
Maury page id
psix-52914

Inspections, by type

…with no type recorded15
Years with a record 31 calendar years (1981–2016)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF9157MMSI 367502310 · expired · compulsorily equipped · granted 20 August 2011, cancelled 23 October 2021
WCZ3448MMSI not assigned · expired · compulsorily equipped · granted 16 June 1999, cancelled 22 August 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

EXCELLENCE Tank Ship · MISLE 755678 · 10 October 2005 · activity 2547058INT'L ENFORCER Offshore Supply Vessel · MISLE 51314 · 5 January 1998 · activity 69712

Inspection history · 58

3 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5966768
20 October 2015 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5865039
18 October 2015 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5745334
5 October 2015 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5734443
16 June 2014 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4890227
15 June 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4890444
23 July 2012 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4389383
13 February 2012 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4243514
20 September 2011 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4150289
1 October 2010 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3862901
25 September 2006 Hull Examination · Spot Check · COI Inspection · Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2778463
10 October 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2547058
20 June 2005 Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2389568
9 June 2004 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2086618
18 November 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1950230
17 October 2003 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1930444
8 October 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1687319
13 June 2002 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1630365
6 September 2001 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1071507
27 August 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1408804
27 March 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 224258
8 September 2000 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1054184
15 June 2000 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463598
4 November 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 799055
6 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 778067
24 June 1999 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1465498
18 June 1998 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465408
14 January 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421443
5 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 69712
6 May 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364128
24 June 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459235
15 September 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182445
29 June 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358827
30 June 1994 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385263
23 February 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 70518
2 July 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414165
2 July 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466819
24 December 1991 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268656
3 July 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245925
26 June 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915780
13 July 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1227491
10 May 1990 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235141
7 March 1990 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903360
26 July 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890415
19 September 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043546
5 August 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1343446
16 October 1987 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1324468
12 August 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003874
19 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322286
9 September 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005895
18 August 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021260
26 July 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989717
26 July 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332624
29 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984436
8 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282844
21 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278621
6 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275680
1 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276702

Deficiency record · 80

Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 August 2016 No resolution recorded
Missed Dry Dock Date
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 18 October 2015 Resolved
Fuel piping system suspected of have a blockage at the tank's crossover fuel line.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2015
Resolved 21 October 2015
Resolution: Fuel tanks and associated piplines were cleaned and access plate gasket was replaced with proper gasket material. Fuel system is delivery fuel from both tanks.
Communications › Radio Communications › EPIRB
Issued 5 October 2015 Resolved
Expired hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2015
Resolved 6 October 2015
Resolution: Replaced hydrostatic release mechanism.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pressure
Issued 5 October 2015 Resolved
AFFF eductor not working at all angles.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2015
Resolved 6 October 2015
Resolution: Replaced valve on AFFF eductor. Retested eductor, all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 October 2015 Resolved
01 waterlight was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 6 October 2015
Resolution: Replaced inoperable waterlight.
Lifesaving › Lifefloat › Paddle
Issued 5 October 2015 Resolved
02 paddles were too short of required 4 foot length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 6 October 2015
Resolution: Replaced with longer paddles.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 June 2014 Resolved
Vibrations noted at the shaft and propeller arrangments. Vessel is to drydock to affect perm repairs prior to operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 June 2014
Resolution: Vessel repaird both rudders and replaced all propellers.
Construction/Loadline › Structures › Deck Plating
Issued 20 September 2011 Resolved
Complete pickup welds on internal structure in engineroom and in amidship crew quarters.
Condition: Damaged By Earlier Event
Due 27 September 2011
Resolved 27 September 2011
Resolution: Welds were completed.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 September 2011 Resolved
Provide junction boxes for all wire ties more than 12 Volts
Condition: Improper Installation
Due 27 September 2011
Resolved 27 September 2011
Resolution: Junction boxes were provided for all loose wiring.
Electrical › Electric Generation Source (service) › Switch
Issued 20 September 2011 Resolved
Label all switches on switchboard in generator room.
Condition: Improper Installation
Due 27 September 2011
Resolved 27 September 2011
Resolution: Switch was labeled.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 September 2011 Resolved
Provide a light in light socket in amidships berthing space.
Condition: Improper Installation
Due 27 September 2011
Resolved 27 September 2011
Resolution: Light placed in light socket.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 20 September 2011 Resolved
VGP was not present on vessel. Owner has been given information to get permit.
Due 27 September 2011
Resolved 20 September 2011
Resolution: Vessel has been given proper EPA regs to get permit.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 2 January 2007 Resolved
Repair exhaust leakiwo jacket water cooler on center MDE.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Repaired.
Construction/Loadline › Structures › Door
Issued 2 January 2007 Resolved
Replace gasket on scuttle in rudder room.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Scuttle was replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 2 January 2007 Resolved
Determine/repair problem with centerline mde exhaust.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Tuned up engine.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 7 December 2006 Resolved
Repair leak to center mde oil pump.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Repaired pump.
Engineering › Diesel Engine (propulsion-direct drive) › Crankshaft
Issued 7 December 2006 Resolved
Install machinery guard on outboard mde's.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Guards installed.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 7 December 2006 Resolved
Waste Management plan for foreign garbage.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Plan onboard vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 25 September 2006 Resolved
Vessel suffer MDE Failure while underway. Vessel must complete repairs to the satisfaction of CG Marine inspector prior to operation.
Action required: 705 - Other - as specified
Resolved 3 September 2010
Resolution: All three propulsion engines tested satifactory.
Lifesaving › Lifefloat › Serviceable
Issued 14 September 2006 Resolved
Replace 22 person life float due to dry rot.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Electrical › Electric Generation Source (service) › Generator
Issued 14 September 2006 Resolved
Provide adequate operation under load and underway of p/s gen.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 September 2006 Resolved
Anchor windless remove motor.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Gear removed.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 14 September 2006 Resolved
50 % of crew must have CPR cards.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Crew has been trainined.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 September 2006 Resolved
Provide servicing cerrtificates for portable fire fighting equipment.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Certificates provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 September 2006 Resolved
Replace MOB recovery ladder.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 14 September 2006 Resolved
Repair/adjust over-speed trip on port gen
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: repaired
Engineering › Fuel Oil Service System › Piping
Issued 14 September 2006 Resolved
Repair fuel leak on port gen.
Action required: 705 - Other - as specified
Resolved 19 January 2007
Resolution: Hose replaced.
Lifesaving › Lifefloat › Serviceable
Issued 20 June 2005 Resolved
Replace/renew 02 wasted/worn lifefloats from vessel.
Condition: Improper/Lack of Maintenance
Due 5 July 2005
Resolved 7 July 2005
Resolution: Vessel replaced wasted lifloats with 02 new
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2005 Resolved
Remove extension cord that is permanently wired to power strip in passenger area behind television
Condition: Improper Installation
Due 5 July 2005
Resolved 7 July 2005
Resolution: Vessel removed extension cord and replaced with approved wire and installed an appropriate outlet
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 June 2005 Resolved
Conduct a required man overboard and abandon ship drill and record in vessel/s log.
Condition: Unknown
Due 30 June 2005
Resolved 30 June 2005
Resolution: Vessel conducted required man overboard and abandon ship drill and recorded in ship''''s log
Engineering › Bilge Water Management System › Valve
Issued 20 June 2005 Resolved
Rework forepeak bilge shut off valve
Condition: Improper/Lack of Maintenance
Due 5 July 2005
Resolved 7 July 2005
Resolution: Vessel reworked forpeak shut off valve. Valve operates properly.
Engineering › Compressed Air System (control) › Valve
Issued 20 June 2005 Resolved
Renew/replace pressure relief valves on both air receivers.
Condition: Improper/Lack of Maintenance
Due 5 July 2005
Resolved 7 July 2005
Resolution: Vessel replaced pressure relief valves on both air receivers. Valves operate properly
Engineering › Steering Gear System › Ram
Issued 20 June 2005 Resolved
Gouge and reweld cracked welds at the base of the rudder ram support
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2005
Resolved 20 June 2005
Resolution: Vessel repaired cracked weld at ram support.
Construction/Loadline › Hull › Longitudinal Frame
Issued 20 June 2005 Resolved
Gouge and reweld fracture on weld in forepeak STBD side framing
Condition: Improper/Lack of Maintenance
Due 5 July 2005
Resolved 7 July 2005
Resolution: Fractured weld was repaired properly
Electrical › Lighting (service) › Lighting Fixture
Issued 20 June 2005 Resolved
Afix stbd side engine room light cover.
Condition: Unknown
Due 5 July 2005
Resolved 7 July 2005
Resolution: Vessel installed engine room light cover
Engineering › Fuel Oil Service System › Valve
Issued 20 June 2005 Resolved
Remark fuel shutdowns on main deck
Condition: Unknown
Due 5 July 2005
Resolved 7 July 2005
Resolution: Vessel remarked fuel shutdowns on main deck
Fire Fighting › Fire Pumps › Impeller
Issued 23 June 2004 Resolved
Prove proper operation of fire pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2004
Resolved 29 June 2004
Resolution: New pump installed and tested.
Engineering › Bilge Water Management System › Interface Detector
Issued 23 June 2004 Resolved
Prove proper operation of all high level bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2004
Resolution: High level bilges alarms repaired replaced and tested sat.
Communications › Radio Communications › EPIRB
Issued 23 June 2004 Resolved
Renew expired battery and hydrostaic release in EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2004
Resolution: New battery and hydrostatic release iunstalled.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 June 2004 Resolved
Replace bulb and prove proper operation of emergency light in lower passenger space forward of generator room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2004
Resolution: New bulb installed and light tested.
Lifesaving › Lifefloat › Lifeline
Issued 23 June 2004 Resolved
Renew grabline/lifeline on 25 man lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2004
Resolution: Lefe line renewed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 23 June 2004 Resolved
Renew 11 expired lights on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2004
Resolution: Lights replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 June 2004 Resolved
Provide prooof of annual servicing of fire extinguishers.
Condition: Improper/Lack of Maintenance
Due 7 July 2004
Resolved 29 June 2004
Resolution: Servicing report provided.
Engineering › Bilge Water Management System › Pump
Issued 23 June 2004 Resolved
Secure bilge pump to mount.
Condition: Improper Installation
Due 7 July 2004
Resolved 29 June 2004
Resolution: Bilge pump secured to mount.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 23 June 2004 Resolved
Attach support to stuffing tube on starboard engine shaft.
Condition: Improper/Lack of Maintenance
Due 7 July 2004
Resolved 7 July 2004
Resolution: Support attached to stuffing tube.
Engineering › Bilge Water Management System › Pump
Issued 23 June 2004 Resolved
Remove excess oil and water from bilge and make available for inspection.
Condition: Improper/Lack of Maintenance
Due 7 July 2004
Resolved 7 July 2004
Resolution: Excess water and oil removed from bilge.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 June 2004 Resolved
Install machinery guard on front of starboard generator pulley.
Condition: Unknown
Due 7 July 2004
Resolved 7 July 2004
Resolution: Machinery guard installed.
Construction/Loadline › Hull › Stiffener
Issued 23 June 2004 Resolved
Repair fracture on port rudder stop.
Condition: Unknown
Due 7 July 2004
Resolved 7 July 2004
Resolution: Fracture goouged and rewelded.
Construction/Loadline › Hull › Stiffener
Issued 23 June 2004 Resolved
Repair fracture on port bit support in rudder room.
Condition: Unknown
Due 7 July 2004
Resolved 7 July 2004
Resolution: Fracture gouged and rewelded.
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 June 2004 Resolved
Repair fracture on frame under starboard engine transmission.
Condition: Unknown
Due 7 July 2004
Resolved 7 July 2004
Resolution: Fracture gouged and welded.
Communications › Visual Communication
Issued 17 October 2003 Resolved
Properly label escape hatches LEGACY COMPONENT DESC: Labeling
Due 17 November 2003
Resolved 18 November 2003
Construction/Loadline › Hull
Issued 17 October 2003 Resolved
Gouge and re-weld fractures in rudder room under port side bit and aft vertical stringer next to it. LEGACY COMPONENT DESC: Weld
Due 17 November 2003
Resolved 18 November 2003
Construction/Loadline › Hull
Issued 17 October 2003 Resolved
Gouge and re-weld fracture in forepeak, stbd side on collision bulkhead and deck weld. LEGACY COMPONENT DESC: Weld
Due 17 November 2003
Resolved 18 November 2003
Electrical › Electric Generation Source (service)
Issued 17 October 2003 Resolved
Demonstrate proper operation of port generator over-speed trip. LEGACY COMPONENT DESC: Prime mover
Due 17 November 2003
Resolved 18 November 2003
Construction/Loadline › Structures
Issued 17 October 2003 Resolved
Service and make free all emergency escape hatch mechanisms. LEGACY COMPONENT DESC: Machinery Space Opening
Due 17 November 2003
Resolved 18 November 2003
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 October 2003 Resolved
Vessel was operating on an expired COI between September 21, 2203 and October 17, 2003 for a period of 26 days.
Due 17 October 2003
Resolved 17 October 2003
Resolution: Rcvd COI inspection and Letter of Warning.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 13 June 2002 Resolved
Replace broken and missing lagging on main engine exhaust. site 46 CFR 182.430 (a)(b) LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 21 July 2002
Resolved 24 July 2002
Engineering › Compressed Air System (control)
Issued 13 June 2002 Resolved
Replace and test relief valve on starboard side air receiver. site : 46 CFR 176.812 LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 24 July 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 13 June 2002 Resolved
Install sea rails on stove. site: 46 CFR 184.220 (e)
Condition: Placed in Improper Service
Due 21 July 2002
Resolved 24 July 2002
Construction/Loadline › Hull
Issued 13 June 2002 Resolved
Repair fractures in way of Portside, forward of galley space in beam connecting at No. 2 from forward, and No. 5 from forward . LEGACY COMPONENT DESC: Weld
Condition: Unknown
Due 21 July 2002
Resolved 24 July 2002
Electrical
Issued 27 August 2001 Resolved
Make watertight all electrical fittings in way of starboard side EngineRoom/Steering Gear compartment watertight bulkhead.
Condition: Unknown
Due 5 September 2001
Resolved 13 June 2002
Accommodation/Occupational Safety
Issued 27 August 2001 Resolved
Renew A/C exhaust vent to piot house.
Condition: Unknown
Due 5 September 2001
Resolved 6 September 2001
Electrical
Issued 27 August 2001 Resolved
Prove proper operation of the single sideband radio.
Condition: Unknown
Due 30 August 2001
Resolved 13 June 2002
Lifesaving
Issued 15 June 2000 Resolved
Repair minor cut on lower Lifefloat.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Accommodation/Occupational Safety
Issued 15 June 2000 Resolved
Secure clothes dryer against vessel mevement.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Navigation
Issued 15 June 2000 Resolved
Repair magnetic compass light.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Navigation
Issued 15 June 2000 Resolved
Make any necessary repairs to single side band radio. Provide service technician's report that unit is operating properly. Vessel may not operatemore than 20 NM from shore until corrected.
Condition: Unknown
Due 15 June 2000
Resolved 20 July 2000
Electrical
Issued 15 June 2000 Resolved
Provide butt connectors on spliced electrical wiring at galley range hood light and under pilot house forward steering console.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Accommodation/Occupational Safety
Issued 24 June 1999 Resolved
REATTACH FORWARD PORT SIDE HANDRAIL BASE TO DECK TO SATISFACTION OF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 13 October 1999
Resolved 3 November 1999
Lifesaving
Issued 24 June 1999 Resolved
PROVIDE ON BOARD RESCUE PLATFORM AND HARNESS OR RESCUE BOAT TO SATISFACTIONOF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 27 July 1999
Resolved 12 November 1999
Fire Fighting
Issued 24 June 1999 Resolved
FREE UP FORWARD PORT SIDE ENGINE ROOM VENT CLOSURE TO SATISFACTION OF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 13 October 1999
Resolved 3 November 1999
Engineering
Issued 29 June 1995 Resolved
LABEL PILOTHOUSE ALARM CONTROL SWITCHES.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Lifesaving
Issued 29 June 1995 Resolved
PROVIDE SERVICE REPORT FOR INSPECTION AND REPAIR OF ENGINE ALARM SYSTEM.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Lifesaving
Issued 29 June 1995 Resolved
INSPECT AND REPAIR FIRE MONITOR PUMP.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Engineering
Issued 29 June 1995 Resolved
REPAIR MAIN ENGINE TACHS IN PILOTHOUSE.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Construction/Loadline
Issued 29 June 1995 Resolved
REPAIR LEAKS IN BOLTED DECK HATCHS ABOVE ENGINE ROOM.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Accommodation/Occupational Safety
Issued 2 July 1993 Resolved
REPLACE COPPER WATER PIPING TO WASHER WITH APPROPRIATELY INSTALLED METAL_x001C_ PIPING FOLLOWING GOOD MARINE PRACTICES. REPAIR MUST BE SATISFACTORY TO _x001C_ COGNIZANT OCMI.
Condition: Unknown
Due 27 July 1993
Resolved 27 July 1993
Electrical
Issued 2 July 1993 Resolved
SECURE WIRING, AS NECESSARY, IN ENGINE ROOM WITH APPROPRIATE METAL FASTENERS FOLLOWING GOOD MARINE PRACTICES._x001C_
Condition: Unknown
Due 27 July 1993
Resolved 27 July 1993
Lifesaving
Issued 18 August 1986 Resolved
PROVIDE A SUITABLE RESCUE PLATFORM PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 18 August 1986
Resolved 18 August 1986
Documentation
Issued 26 July 1986 Resolved
PROVIDE THE ORIGINAL CERTIFICATE OF DODUMENTATION ON BOARD THE VESSEL.
Condition: Unknown
Due 26 July 1986
Resolved 26 July 1986

Casualty record · 2

10 October 2005Routine · role: Involved in a Marine Casualty · activity 2547058
20 October 2015Routine · role: Involved in a Marine Casualty · activity 5865039
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.