Inspection history · 5
9 December 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8060238
2 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6137437
27 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5914244
2 June 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5887394
6 January 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5791045
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 2 June 2016
Resolved
Vessel name on stern was covered by fenders.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 June 2016
Resolution: Vessel name visible from stern.
Stability › Unintentional Flooding › General
Issued 2 June 2016
Resolved
port and starboard shaft packing not satisfactory. Appears the packing was gone.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2016
Resolution: Repacked both shafts.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 June 2016
Resolved
Engine room bilge alarm on bridge was not operable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2016
Resolved 3 June 2016
Resolution: Alarm was repaired and tested prior to completion of inspection.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 June 2016
Resolved
Vessel crew had not been conducting drills since vessel was laid up.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2016
Resolution: Conducted and recorded drills.
Communications › Audible Communications › Bell
Issued 2 June 2016
Resolved
Nav bell was cracked in unable to make any audible sound.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 June 2016
Resolution: Installed new 12 inch bell.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 June 2016
Resolved
waterlight was filled with water due to worn gasket material.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2016
Resolution: New waterlight was attached prior to completion of inspection.
Engineering › Compressed Air System (start air) › Valve
Issued 2 June 2016
Resolved
Gague did not show sufficient PSI range
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 June 2016
Resolution: Installed new 300psi Gague.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 June 2016
Resolved
stations #2 and #3 were not seriviced in the past year
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2016
Resolution: Third party inspector came on board and serviced both extinguishers prior to completion of inspection.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 June 2016
Resolved
Crew was not conducting lifesaving maintenance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 June 2016
Resolution: Conducted and recorded lifesavings equipment maintenance, created sheets for weekly and monthly checks and implemented it.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 June 2016
Resolved
Portable light for bridge could not be found.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 June 2016
Resolution: two new portable lights, tested sat.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 2 June 2016
Resolved
Jacket water gauge for starboard MDE located on bridge not operational. Gauge located in E/R operated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 June 2016
Resolution: Replace sensor for jacket water, tested sat.