Records from 1981 to 2017. Most recent: inspection, 13 June 2017.
Inspection history · 67
13 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6174855
30 August 2011
Internal Structural Exam · Examination of Repairs · COI Inspection · Cargo Tank Internal · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4131146
7 July 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4072653
30 September 2008
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3335896
23 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3330830
22 September 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3330482
19 September 2008
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3330145
25 September 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3065501
27 June 2006
Deficiency Check · COI Inspection · MTSA/ISPS Verification · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2692767
18 August 2005
Ballast Water Examination · Re-Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2466638
9 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2384950
9 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2385164
2 August 2004
MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2156152
23 June 2004
Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2108314
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977012
17 July 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1863741
12 July 2002
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1645399
3 July 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1640535
27 June 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418929
13 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669851
26 October 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 823569
27 September 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471746
2 December 1999
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1351668
16 December 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 669855
15 December 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766464
11 December 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 198081
8 December 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 70154
8 December 1998
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 807311
21 October 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469872
29 September 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408179
25 September 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459336
2 October 1996
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1380658
28 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763375
18 October 1995
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394398
17 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 198083
25 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758272
25 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 198077
10 November 1994
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403862
28 June 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026149
28 October 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407223
15 July 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 117338
18 February 1993
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439356
16 February 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 669850
6 February 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 69120
2 November 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399784
4 November 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250953
4 October 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911999
9 July 1990
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228515
17 November 1989
Hull Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223176
5 June 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1351506
8 July 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 896164
9 June 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 890093
6 May 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1346454
5 May 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1345863
25 April 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1346452
5 April 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205645
23 June 1987
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1316451
23 December 1986
Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1027769
9 September 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1001971
21 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292859
19 June 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306251
30 November 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989960
17 October 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299802
17 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302699
19 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978913
2 May 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275859
19 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964277
Communications › Audible Communications › Horn/Whistle
Issued 30 August 2011
Resolved
Air horn does not work.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2011
Resolved 10 October 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 August 2011
Resolved
Wire run in stair well from mess deck to 01 deck not properly supported with metal hangar every 24"
Due 4 November 2011
Resolved 10 October 2011
Engineering › Fuel Oil Service System › Piping
Issued 30 August 2011
Resolved
Several fuel lines on generators and main engines are deteriorated and leaking
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2011
Resolved 10 October 2011
Lifesaving › Inflatable Liferafts › Painter
Issued 30 August 2011
Resolved
Painter line not properly attached to weak link
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2011
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 September 2008
Resolved
Port exhaust stack/ engine room access watertight door to be made watertight again. They have the option of closing it off completely since there is a secondary means of escape on the stbd side, or rebuilding the door frame.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2008
Resolved 30 September 2008
Resolution: WTD repaired
Electrical › Electric Generation Source (service) › Generator
Issued 25 September 2007
Resolved
Fix fuel leak port generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2007
Construction/Loadline › Structures › Door
Issued 25 September 2007
Resolved
Replace door gaskets engine room fwd and aft doors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2007
Construction/Loadline › Structures › End Bulkhead
Issued 25 September 2007
Resolved
G&W crack in stbd ballast tank interior blkhd IWO rudder room passageway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 August 2006
Resolved
Perform Audit of automation Test Procedures. Provide Updated procedure for CG approval w/in 30 days.
Due 11 October 2006
Resolved 7 September 2006
Resolution: Deep South Marine Service, Inc provided documentation indicating the automation test descrepancies were due to their oversight. Provided new automation test procedure results. Audit to test procedures no longer neccessary.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 July 2003
Resolved
Submit revised fire/safety plan for USCG review.
Due 17 September 2003
Resolved 18 August 2005
Resolution: Cleared at previous inspection.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 July 2003
Resolved
Provide three Type I PFDs.
Due 17 July 2003
Resolved 17 July 2003
Resolution: Receipt provided.
Engineering › Steering Gear System › Piping
Issued 17 July 2003
Resolved
Secure steering hydraulic line (piping) to bulkhead.
Due 17 August 2003
Resolved 22 December 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 July 2003
Resolved
Cap sewage tank ullage opening.
Due 17 August 2003
Resolved 18 August 2005
Resolution: Cleared at previous inspection.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 17 July 2003
Resolved
Re-paint loadline.
Due 17 August 2003
Resolved 18 August 2005
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 17 July 2003
Resolved
Correct vessel name on hull to match Certificate of Documentation.
Due 17 August 2003
Resolved 18 August 2005
Resolution: Cleared at previous inspection.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 July 2002
Resolved
PROVIDE CURRENT LIGHT LIST.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2002
Resolved 4 July 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 July 2002
Resolved
DEMONSTRATE PROPER OPERATION OF SEPERATE VISUAL INDICATORS FOR BILGE HIGH LEVEL ALARMS AT OPERATING STATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 18 August 2005
Resolution: Cleared at previous inspection.
Lifesaving › Lifebuoys
Issued 3 July 2002
Resolved
RENEW ONE LIFERING.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2002
Resolved 3 July 2002
Communications › Internal Communications System › Sound-powered Telephone
Issued 3 July 2002
Resolved
DEMONSTRATE PROPER OPERATION OF VISUAL OR AUDIBLE INDICATOR FOR THE SOUND POWER PHONE IN ENGINE ROOM.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 18 August 2005
Resolution: Cleared at previous inspection.
Engineering › Fuel Oil Service System › Filter
Issued 3 July 2002
Resolved
PROVIDE METAL PLUGS FOR RACOR FILTER DRAIN VALVES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 3 July 2002
Construction/Loadline › Structures › End Bulkhead
Issued 3 July 2002
Resolved
MAKE FWD ENGINE ROOM BULKHEAD WATER TIGHT AROUND WIRE RUN.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 18 August 2005
Resolution: Cleared at previous inspection.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 July 2002
Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON MAIN ENGINE FLEXIBLE HOSES. LEGACY COMPONENT DESC: FLEXIBLE HOSES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 July 2002
Resolved
MAKE PERMANENT REPAIRS TO DEEP FRAMES IWO RUDDER ROOM AT STBD RUDDER.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2002
Resolved 5 July 2002
Lifesaving
Issued 27 September 2000
Resolved
01. DEMONSTRATE COMPLIANCE WITH CG D8 RESCUEBOAT POLICY DATED 12NOV98.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Construction/Loadline
Issued 29 September 1998
Resolved
REPAIR/ REPLACE STBD WEATHERDECK ENGINE ROOM WTD TO ALLOW PROPER OPERATION.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Engineering
Issued 29 September 1998
Resolved
PROVIDE THIRD PARTY VERIFICATION OF ALL AUTOMATION ALARMS AND INDICATORS REQUIRED BY NAVIC 1-78 CHANGE 1.
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Deck/Cargo
Issued 18 October 1995
Resolved
PROVE PROPER OPERATION OF ANCHOR WINDLASS SYSTEM IN PRESENCE OF ABS CLASS SURVEYOR OR USCG MARINE INSPECTOR.
Condition: Unknown
Due 31 October 1995
Resolved 25 October 1995
Construction/Loadline
Issued 18 October 1995
Resolved
CROP AND RENEW PORT VOID LONG BLKHD PLATE IN ENGINE ROOM APPROX. 6'X 6' ANDAIR TEST TO VERIFY WATERTIGHT INTEGRITY OF VOID. PROVIDE SAT. ABS CLASS REPORT OF REPAIR AND TEST OR CONDUCT IN PRESENCE OF USCG MARINE INSPECTOR, PRIOR TO PLACING VESSEL IN SERVICE.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Engineering
Issued 18 October 1995
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM ALARM PANEL INDICATOR LIGHTS IN PILOTHOUSE.
Condition: Unknown
Due 31 October 1995
Resolved 25 October 1995
Unknown
Issued 17 November 1989
Resolved
REPAIR PORT AND STBD SHAFT TACHS TO ORIGINAL OPERATION.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Unknown
Issued 17 November 1989
Resolved
UPDATE DEVIATION TABLE ON THE MAGNETIC COMPASS.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Navigation
Issued 9 June 1988
Resolved
PROVIDE LIGHT LIST AND COAST PILOT.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Navigation
Issued 9 June 1988
Resolved
PROVIDE TOP COVER FOR PORT RUNNING LIGHT AND FWD MAST LIGHT.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Accommodation/Occupational Safety
Issued 9 June 1988
Resolved
RECONNECT DRAIN PIPE TO NUMBER TWO DRY BULK TRUNK.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Engineering
Issued 9 June 1988
Resolved
PROVE AUTOMATION AND TEST OVERSPEED TRIP TO NUMBER ONE MAIN ENGINE.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Navigation
Issued 9 June 1988
Resolved
REPAIR GENERAL ALARM IN ENGINE ROOM.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Construction/Loadline
Issued 9 June 1988
Resolved
RENEW BEARING TO NUMBER ONE MUD PUMP BULK COMPRESSOR.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Navigation
Issued 9 June 1988
Resolved
REPAIR ENGINE ROOM STEERING INDICATOR.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Navigation
Issued 19 June 1986
Resolved
MAKE READY FOR INTERNAL INSPECTION, AND INSPECT STBD AFT P-TANK.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Engineering
Issued 19 June 1986
Resolved
INSTALL SHAFT TACHS WITH MONITORS ON BRIDGE AND IN ENGINE ROOM.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Deck/Cargo
Issued 19 June 1986
Resolved
PROVIDE VESSEL WITH A 2ND ANCHOR REPAIR AND MAKE ANCHOR WINDLASS OPERATIONAL.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Engineering
Issued 19 June 1986
Resolved
REPAIR BOTH MAIN DIESEL ENGINES AND STBD GENERATOR OVERSPEED TRIPS, SO AS TO TRIP AT PROPER RMP SPEED.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Engineering
Issued 19 June 1986
Resolved
POP SAFETY RELIEF VALVES ON BOTH PORT AND STBD AIR RECEIVERS.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Engineering
Issued 19 June 1986
Resolved
PROVIDE AND INSTALL METAL SHIELD (CUPS) ON RAY COR FILTERS (GENERATORS, MUDPUMPS AND BOW THRUSTER ENG).
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Lifesaving
Issued 19 June 1986
Resolved
REPAIR STBD AFT WING BOUY MOUNT.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Navigation
Issued 19 June 1986
Resolved
INSTALL NEWLY REPAIRED LORAN.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Construction/Loadline
Issued 30 November 1985
Resolved
EFFEC PERMANENT REPAIRS TO BOW IN WAY OF THE 9 FOOT DRAFT MARK. PERMANENT REPAIRS ARE TO BE COMPLETED PRIOR TO 30DEC85 AND ARE TO BE TO THE SATISFAC-TION OF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985