Records from 1983 to 2008. Most recent: inspection, 21 November 2008.
Inspection history · 52
21 November 2008
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3367069
26 December 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3121051
10 October 2007
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3077151
26 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2974635
5 January 2006
COC-MODU Annual
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2561628
8 June 2005
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2383920
30 March 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2322830
13 March 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2321674
18 November 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2244249
4 November 2004
COC-MODU Renew
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2251175
3 December 2003
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1939124
6 November 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1715102
21 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1678446
26 July 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1663164
15 July 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646743
30 October 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450703
8 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073281
25 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073153
8 December 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 70154
16 July 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447852
19 January 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1112134
15 November 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 4000
6 November 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 65403
22 July 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441267
20 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878756
14 November 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409189
9 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83151
24 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 55941
3 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 16796
7 January 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161680
18 November 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387426
22 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 696026
2 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 59927
15 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 139184
14 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 149822
24 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 29455
15 April 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032296
13 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318189
28 May 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028553
19 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324879
16 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304912
14 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299033
29 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989614
20 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993600
10 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293287
24 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 981140
23 February 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 980195
22 February 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1287795
20 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971891
21 February 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971493
23 March 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964360
23 February 1983
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1276551
Electrical › Lighting (service) › Lighting Fixture
Issued 24 November 2008
No resolution recorded
3 LIGHT COVERS IN PORT CAISSON WERE BROKEN
Condition: Unknown
Action required: 705 - Other - as specified
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 November 2008
No resolution recorded
WATERTIGHT DOOR FRAME FROM ELEVATOR TO PORT CAISSON IS WASTED
Condition: Unknown
Action required: 705 - Other - as specified
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 21 November 2008
No resolution recorded
EXPOSED BATTERIES IN EMERGENCY GENERATOR ROOM
Action required: 705 - Other - as specified
Fire Fighting › Structural - B Class Divisions › Doors
Issued 21 November 2008
No resolution recorded
CLASS "B' FIRE DOOR FROM MESSDECK TO STATEROOMS MUST MEET FIRE PROTECTION REQUIREMENTS OF MODU CODE 1979
Action required: 705 - Other - as specified
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 November 2007
Resolved
Class 'A' Door between Galley and Pantry did not close properly. Repair to the satisfaction of classification society or flag state.
Action required: 705 - Other - as specified
Resolved 26 December 2007
Resolution: Item cleared by Classification Society on 8 Dec 2007.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 November 2007
Resolved
Class 'A' Door between galley and messdeck did not close properly. Repair to the satisfaction of classification society or flag state.
Action required: 705 - Other - as specified
Resolved 26 December 2007
Resolution: Item cleared by Classification Society on 8 Dec 2007.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 November 2007
Resolved
Class 'A' Door between messdeck and main deck outside skin of vessel did not close properly. Repair to the satisfaction of classification society or flag state.
Action required: 705 - Other - as specified
Resolved 26 December 2007
Resolution: Item cleared by Classification Society on 8 Dec 2007.
Communications › Alarms/Indicators › General Alarm
Issued 4 November 2004
Resolved
Provide General Alarm Bell on 3rd deck starboard passage. IMO MODU CODE 10.6.4
Condition: Unknown
Due 20 November 2004
Resolved 19 November 2004
Resolution: Recieved IOM statement of fact confirming correction of deficiency.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 4 November 2004
Resolved
Test both life boats as per IMO MODU CODE 10.6.3.3
Condition: Unknown
Due 18 November 2004
Resolved 7 November 2004
Resolution: Received IOM statement of fact that the test was conducted.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 4 November 2004
Resolved
Provide proof of anual pressure test of fuel transfer hoses to 1.5 MAWP IAW 33CFR156.170
Condition: Improper/Lack of Maintenance
Due 19 November 2004
Resolved 17 November 2004
Resolution: OIM Provided Statement of fact of new hose installation as well as manufacturers test certificate.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 4 November 2004
Resolved
Prove proper operation of #3 generator breaker switch. IMO CODE 5.1.1.3
Condition: Unknown
Due 19 January 2005
Resolved 17 January 2005
Resolution: New switch installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 November 2004
Resolved
Provide report and make repairs to deteriorated and leaking sections of salt water suction piping in both aft caissons.
Condition: Improper/Lack of Maintenance
Due 30 January 2005
Resolved 8 June 2005
Resolution: Both sea water supply lines were replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 4 November 2004
Resolved
Renew or hydro test nitrogen pilot cylinders for engine room and and port caisson Halon Fixed Fire Extinguishing system. Both systems have one cylinder past the hydro test date.
Condition: Damaged By Earlier Event
Due 4 November 2004
Resolved 4 November 2004
Resolution: Cylinders renewed.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 4 November 2004
Resolved
Complete repairs to and prove proper operation of port lifeboat starting system and engine exhaust leak.
Condition: Improper/Lack of Maintenance
Due 20 November 2004
Resolved 15 November 2004
Resolution: Repairs complete.
Documentation › Logs/Records
Issued 3 December 2003
Resolved
Amend. muster list to reflect 2nd. in command of lifeboats IAW 46CFR109. LEGACY COMPONENT DESC: Muster list
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 10 December 2003
Resolution: Received e-mail from [name withheld] with new muster list attached.
Documentation › Logs/Records
Issued 3 December 2003
Resolved
Provide garbage logs meeting the record keeping requirements in 33 CFR 151.55. LEGACY COMPONENT DESC: Garbage Recordkeeping
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 9 February 2004
Documentation › Logs/Records
Issued 3 December 2003
Resolved
Provide proof of annual crane exam for 03. LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 18 March 2004
Construction/Loadline › Structures
Issued 3 December 2003
Resolved
Relocate Petrocom Stratos/SOLA antenna and wind sock off of Helo deck. LEGACY COMPONENT DESC: Helo Deck
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 10 December 2003
Resolution: Received e-mail from [name withheld] stating that Phone antenna and wind sock has been relocated.
Electrical › Electrical Distribution System (service)
Issued 3 December 2003
Resolved
Provide audio or visual purge alarms for 3rd. party equipment on drill floor. LEGACY COMPONENT DESC: Purge alarms
Action required: 705 - Other - as specified
Due 3 January 2004
Resolved 10 December 2003
Resolution: Received e-mail from [name withheld] stating that oilfield instrument alarm is working.
Lifesaving
Issued 16 July 1998
Resolved
INSTALL MISSING RELEASE GEAR SEAL ON LIFEBOAT NO. 2.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Lifesaving
Issued 16 July 1998
Resolved
CONDUCT 1.1 OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR OR CONDUCT AN ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL OCMI.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Lifesaving
Issued 16 July 1998
Resolved
REFILL EXPENDED AIR BOTTLE IN LIFEBOAT NO. 2.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Electrical
Issued 16 July 1998
Resolved
CONDUCT AND PROPERLY LOG EMERGENCY BATTERY TESTS IAW 46 CFR 109.211.
Condition: Unknown
Due 16 August 1998
Resolved 21 July 1998
Lifesaving
Issued 16 July 1998
Resolved
CONDUCT AND PROPERLY LOG LIFEBOAT MONTHLY MAINTENANCE IAW 46 CFR 109.301(E).
Condition: Unknown
Due 16 August 1998
Resolved 21 July 1998
Construction/Loadline
Issued 16 July 1998
Resolved
PAD WELD HOLE IN LOWER PORT DECK STORAGE LOCKER DECK. CROP AND RENEW AS ORIGINAL AT NEXT DRYDOCK. LOCATE AND REPAIR SOURCE OF LEAK IN THE LOWER PORT DECK STORAGE LOCKER.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Documentation
Issued 16 July 1998
Resolved
SUBMIT TO [name withheld] FOR APPROVAL AN EMERGENCY EVACUATION PLAN FOR FALCON 203 WORKING AT SOUTH MARSH ISLAND 023.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Unknown
Issued 16 July 1998
Resolved
INSTALL SAFETY CHAINS ON THE PORT AND STARBOARD LIFEBOAT WINCH DECK RAILS.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Fire Fighting
Issued 16 July 1998
Resolved
RE-INSTALL HALON FIREFIGHTING SYSTEM THAT PROTECTS PORT PUMP ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 July 1998
Resolved 31 July 1998
Unknown
Issued 16 July 1998
Resolved
CROP AND RENEW WASTED AND HOLED HAND RAILS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Lifesaving
Issued 16 July 1998
Resolved
CONDUCT AND PROPERLY LOG WINCH BRAKE EXAM AND DYNAMIC TEST OF LIFEBOAT WINCH BRAKE IAW 46 CFR 109.30(I)(2).
Condition: Unknown
Due 16 August 1998
Resolved 21 July 1998
Fire Fighting
Issued 16 July 1998
Resolved
CROP AND RENEW WASTED FIXED FIREFIGHTING PIPING THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Lifesaving
Issued 16 July 1998
Resolved
REPAIR TWO CRACKS IN LIFEBOAT NO. 1'S HULL, LOCATED ON THE STERN AND UNDER_x001C_THE PORT QUARTER BUMPER. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Construction/Loadline
Issued 22 July 1997
Resolved
REPAIR HELIDECK PERIMETER GUARD.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Documentation
Issued 22 July 1997
Resolved
PLACE CRANE RECORD BOOK ON BOARD IN ACCORDANCE WITH 46 CFR 109.437.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Fire Fighting
Issued 22 July 1997
Resolved
MAKE STAIRTOWER DOORS SELF-CLOSING AND CAPABLE OF LATCHING.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Lifesaving
Issued 22 July 1997
Resolved
PLACE AUXILIARY LINE THROWING APPLIANCE LINE ON BOARD.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Documentation
Issued 22 July 1997
Resolved
REVISE FIRE CONTROL PLAN AND SUBMIT TO CLASSIFICATION SOCIETY FOR APPROVAL.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Lifesaving
Issued 22 July 1997
Resolved
PLACE INTERIOR LIGHTING AND PAINTER LINES IN EACH LIFEBOAT.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Lifesaving
Issued 22 July 1997
Resolved
COMPLY WITH EMERGENCY TRAINING AND DRILL REQUIREMENTS OF 46 CFR 109.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Electrical
Issued 22 July 1997
Resolved
PROPERLY SECURE LOOSE WIRING ON DRILL FLOOR AND IN SHAKER AREA.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Engineering
Issued 22 July 1997
Resolved
REPLACE FUEL TRANSFER HOSE PRIOR TO CONDUCTING TRANSFER OPERATIONS.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Electrical
Issued 22 July 1997
Resolved
PROPERLY LABEL MOTOR CONTROLLERS THROUGHOUT RIG.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Electrical
Issued 22 July 1997
Resolved
CONDUCT EMERGENCY GENERATOR SHUTDOWN TESTS TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Electrical
Issued 22 July 1997
Resolved
REPAIR LOW LUBE OIL PRESSURE SHUTDOWN ON GENERATOR NO. 1. CONDUCT TEST TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Electrical
Issued 22 July 1997
Resolved
REPAIR REVERSE POWER RELAY ON GENERATOR NO. 2. CONDUCT TEST TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Lifesaving
Issued 14 November 1994
Resolved
PROVE TEST PROPER OPERATION OF MUD PIT ROOM VENTILATION LOSS ALARM PANEL.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Construction/Loadline
Issued 14 November 1994
Resolved
PROVE TEST PROPER OPERATION OF BILGE PUMP ALARMS.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Documentation
Issued 18 November 1993
Resolved
PROVIDE CERTIFICATE OF REGISTRY REFLECTING NAME CHANGE OF RIG TO [name withheld].
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Electrical
Issued 18 November 1993
Resolved
REPLACE COVER LIGHTING PANEL L-1 IN MUD PUMP RM.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Lifesaving
Issued 18 November 1993
Resolved
PROVIDE LAUNCHING INSTRUCTIONS FOR LIFERAFTS IN IMMEDIATE VICINITY OF LAUNCHING AREAS.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Lifesaving
Issued 18 November 1993
Resolved
INSTALL GENERAL ALARM BELL IN LOCATION SUITABLE TO BE AUDIBLE IN VICINITY OF LIFERAFT STOWAGE AREAS.
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Documentation
Issued 18 November 1993
Resolved
PROVIDE OPERATIONS MANUAL WITH FLAG STATE APPROVAL TO [name withheld].
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Documentation
Issued 18 November 1993
Resolved
PROVIDE SAFE MANNING CERTIFICATE TO [name withheld].
Condition: Unknown
Due 18 November 1993
Resolved 18 November 1993
Unknown
Issued 20 February 1986
Resolved
REPLACE CRACKED GLASS IN REMOTE VENT SHUTDOWN SWITCH IN TOOLPUSHER OFFICE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Unknown
Issued 20 February 1986
Resolved
PROVIDE TWO 1/2 INCH 50 FT FIRE HOSES ON BOARD THE RIG.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Unknown
Issued 20 February 1986
Resolved
SUBMIT A PROPOSAL TO REDUCE REQUIRED MANNING IN THE STACKED MODE, OR PROVIDE FOUR CERTIFICATED LIFEBOATMEN ON BOARD THE RIG.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Unknown
Issued 20 February 1986
Resolved
MAKE OPERABLE THE INTERLOCKS AND DOOR CLOSING MECHANISMS FOR THE DUMBWAITER
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Unknown
Issued 20 February 1986
Resolved
SUBMIT THE CONSTRUCTION PORTFOLIO TO MERCHANT MARINE TECHINICAL, 8TH COAST GUARD DISTRICT 600 SO. MAESTRI, PL. NEW ORLEANS, 70114 FOR APROVAL.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Unknown
Issued 20 February 1986
Resolved
PROVIDE A VALID FLL CERTIFICATATE INDICATING THE CORRECT VESSEL NAME.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Unknown
Issued 20 February 1986
Resolved
REPAIR DAMAGE TO AND REPLACE MISSING SECTIONS OF CAGING FOR ALL ESCAPE LADDERS OF MORE THAN 20 FT IN HEIGHT, LOCATED ON THE FOUR COLUMNS.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 22 February 1985
Resolved
RENEW THE EXPIRED SMOKE SIGNALS AND HAND HELD RED FLARES FOR THE STBD LIFEBOAT.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Electrical
Issued 22 February 1985
Resolved
PROPERLY INSTALL THE ELECTRICAL WIRES PENETRATING THE QUARTERS EXTERIOR BULKHEAD TO THE PIPE RACK AS REQUIRED BY 46 CFR SUBPART 111.60.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Lifesaving
Issued 22 February 1985
Resolved
PROVIDE PERSONAL FLOATATION DEVICE LIGHTS FOR THE 57 EXPIRED LIGHTS AS PER 46 CFR 109.225.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Electrical
Issued 22 February 1985
Resolved
PROPERLY SEAL ALL EXPLOSION-PROOF SEAL FITTINGS WHICH ARE SEALED WITH SILICON SEAL AT THE SHALE SHAKER BUG BLOWER, H2S EQUIPMENT, LIGHTS AT THE AFT END OF THE PIPE RACK LOCATED IN HAZARDOUS LOCATIONS AS REQUIRED BY 46 CFR 111.105-15.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Electrical
Issued 22 February 1985
Resolved
REMOVE THE CABLE SPLICE IN THE MUD PUMP ROOM LOCATED IN AN EXPLOSION-PROOF SEAL FITTING AND PROPERLY SPLICE AS REQUIRED BY 46 CFR 111.60-17 AND 111.60-90.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Lifesaving
Issued 22 February 1985
Resolved
RENEW THE RUPTURE DISC AND RECHARGE THE ENGINE AIR CYLINDER LOCATED IN THE STBD LIFEBOAT.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Electrical
Issued 22 February 1985
Resolved
PROPERLY INSTALL THE ELECTRICAL CABLES AND MONITOR LINES AND AIR HOSE IN THE MUD PIT BULKHEADS WHICH PENETRATE TO THE MUD PUMP ROOM AND PORT AND STBD BULKHEADS AS REQUIRED BY 46 CFR SUBPART 11.60.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Electrical
Issued 21 February 1984
Resolved
REPAIR AUDIBLE ALARM FOR AIR PURGE SYSTEM ON DRILLERS CONSOLE REF 46 CFR 108.187
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Electrical
Issued 21 February 1984
Resolved
INSTALL BLANKS OVER ALL OPENINGS IN ELE SWITCH PANELS IN SCR ROOM AND GALLEY. REF 46 CFR SUBCHAPTER J
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984
Resolved
REMOUNT THE SINK IN HOSPITAL REF 46 CFR 108.209
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Lifesaving
Issued 21 February 1984
Resolved
REPLACE 3 MISSING SERVICE LINES FOR LINE THROWING GUN REF 46 CFR 108.517
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984