TB-1

Built
1981
Last inspected
16 May 2024
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 16 May 2024
…with no type recorded31
Operational controls None recorded without a removal date
Years with a record 37 calendar years (1984–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-53085

Documentation record

Tonnage as PSIX records it383 - Regulatory (Subpart C or D), Gross Ton
262 - Displacement, Gross Ton
383 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 96 inspections, each with its date, unit and type; 77 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 96

16 May 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam · Damage Survey · Examination of Repairs · COI Inspection · Cargo Tank Internal
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7911551
30 August 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7542290
27 July 2021 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7256124
8 September 2020 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7053381
10 August 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7018213
28 August 2019 COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6784037
22 May 2019 Permit to Proceed · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6691012
18 October 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6567475
10 August 2018 Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6511681
3 May 2018 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6411360
31 July 2017 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6287248
20 June 2017 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6168179
31 October 2016 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6032736
3 August 2015 Damage Survey · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5205801
3 August 2015 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5206492
16 July 2015 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5192301
20 May 2015 Administrative Inspection · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5130280
14 August 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4954637
20 March 2014 Drydock Exam · Deficiency Check · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4819943
19 September 2013 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4719369
3 July 2013 MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4641161
27 June 2013 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4634120
16 August 2012 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4413760
23 May 2012 Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4318547
28 June 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3769890
25 April 2010 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3731361
2 April 2009 COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3441427
17 July 2008 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3271049
19 June 2008 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3238687
11 December 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3113729
11 August 2007 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3024330
12 June 2007 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2959226
11 June 2007 Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2955313
28 February 2007 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2879476
10 February 2007 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2870420
12 December 2005 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2552417
27 October 2005 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2510115
3 October 2005 Administrative Inspection · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2480302
29 March 2005 MTSA Verification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2322556
21 September 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2201487
15 September 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2196839
11 August 2004 Deficiency Check · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2162794
15 June 2004 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2099141
13 May 2004 Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2066546
6 February 2004 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2001787
30 December 2003 Administrative Inspection
Administrative · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1999447
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1958052
3 October 2003 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1920590
25 July 2003 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1856843
11 July 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1842258
28 January 2003 Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1733710
3 October 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1684012
16 May 2002 Deficiency Check · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1617553
20 November 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1454989
3 May 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1064915
28 November 2000 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1412211
14 January 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455811
1 March 1999 Deficiency Check · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473099
3 December 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 441860
2 December 1998 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1432032
15 February 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777266
4 December 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1418267
2 December 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1371609
30 January 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 199391
30 January 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 758520
1 December 1995 Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455306
2 December 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 870220
9 August 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 55561
9 August 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 222744
9 August 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 487157
18 March 1994 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 855868
23 November 1993 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1152271
3 May 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 496099
22 April 1993 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1133099
4 December 1992 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1133071
26 December 1991 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 957366
20 May 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 524868
13 December 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 915274
2 November 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 468467
3 October 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 515819
19 March 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 449155
27 November 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 922062
5 September 1989 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 471782
17 July 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 886819
14 June 1989 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1031503
14 June 1989 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1210379
6 January 1989 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 509158
28 November 1988 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 896466
29 September 1988 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 512178
21 December 1987 Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1317627
19 November 1987 MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1023802
26 January 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1316842
30 December 1986 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1311192
10 June 1986 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 485870
28 December 1984 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1285694
14 September 1984 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 491362

Deficiency record · 77

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2022 Resolved
The installation of all electrical engineering or interior communications systems, together with the details of design, construction, and installation must meet the requirements of sub-chapter J. Vessel has exposed electrical wires for a shore tie connection located inside a hazardous location. Repair or remove electrical cables in accordance with 46 CFR 111.105-5 to the satisfaction of an attending marine inspector. 46 CFR 32.45-1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 14 October 2022
Resolution: Vessel representative provided photographic evidence of the junction box that the deadend wires were connected to.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 August 2022 Resolved
Cargo pump relief valves shall be tested at least once a year for accuracy. The electric lube oil pump relief valve has not been tested. Test relief valve to the satisfaction of an attending marine inspector. 46 CFR 35.35-70(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 14 October 2022
Resolution: Vessel provided evidence of testing.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 May 2019 Resolved
Prior to conducting any cargo operations, vessel must complete a satisfactory ISE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2019
Resolution: Vessel's current COI which reflects credit for ISE and MISLE activity no. 6784037.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 August 2018 Resolved
Operator to update cargo piping hydro test reports to accurately reflect the components and tests completed. Test sheet does not identify fuel oil or lube oil relief valve tests.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2018
Resolution: Received email verification that hydro sheets have been updated.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 August 2018 Resolved
Identify lube oil relief valve setting and test.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2018
Resolution: Recieved email verification and documentation confirming lube oil cargo piping details and tests.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 March 2018 Resolved
Provide approved plans for installation of electrical modifications. Verification to the satisfaction of the attending CG marine inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2018
Resolution: Reviewed approved plans and verified electrical installation onboard.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 June 2017 Resolved
Required oil transfer procedures failed to properly list all cargos carried on vessel and associated cargo information.
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 21 June 2017
Resolution: OTP updated.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 November 2016 Resolved
Prove repair of port forward light fixture conduit connection.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 1 November 2016
Resolution: Received photos of repair via email.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 October 2016 Resolved
Company failed to arrange for an annual inspection within the 3 months before or after the anniversary date of the COI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2016
Resolved 1 November 2016
Resolution: Conducted required Annual Inspection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 3 August 2015 Resolved
Pump packing was replaced with undersized packing (.25 requiring .30). New packing was installed. Repairs and final testing need to be evaluated my marine inspector prior to operations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2015
Resolved 10 August 2015
Resolution: Pump tested and no leaks detected. Fit for full service.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 May 2015 Resolved
The cover for a junction box in the shore power distribution line was loose and open. Provide a way to keep the cover closed and secured on the junction box to the satisfaction of marine inspector prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2015
Resolution: Installed a threaded screw into closer device to keep cover for junction box closed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 May 2015 Resolved
The metal conduit for overhead lighting in the cargo pump area was missing a plug in the end of a junction box exposing the wire to the elements. Replace plug in junction box to the satisfaction of marine inspector prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2015
Resolution: Installed threaded plug in end of metal conduit.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 21 May 2015 Resolved
The fire extinguisher mounting bracket on the lube oil tank is the incorrect size for the fire extinguisher. Replace the extinguisher with one of the correct size for the bracket or replace bracket with one that can accommodate the smaller extinguisher.
Action required: 705 - Other - as specified
Resolved 21 May 2015
Resolution: Replaced with fire extinguisher of the right size for the bracket,
Electrical › Electrical Distribution System (service) › Cable
Issued 26 June 2014 Resolved
Propose method to comply with requirements for electrical equipment in hazardous locations.
Action required: 705 - Other - as specified
Due 26 August 2014
Resolved 14 August 2014
Resolution: Amended COI. Reduced cargo authority from Grade D to Grade E cargo, therefore eliminating requirements to meet Class I/Div I electrical protection.
Electrical › Electric Generation Source (service) › Generator
Issued 20 March 2014 Resolved
Ensure generator battery properly secured in battery box.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 25 July 2014
Resolution: Battery used to start vessel generator was placed in an appropriate battery box with lid.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 20 March 2014 Resolved
Ensure cable exiting generator circuit breaker properly installed/secured.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 25 July 2014
Resolution: All cable and conduit exiting generator circuit breaker was peoperly secured with rigid metal hangers.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 March 2014 Resolved
Ensure outlet box in deck house has cover.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 25 July 2014
Resolution: Outlet box in deck house was replaced with new junction box fitted with cover.
Engineering › Pressure Vessel › Relief Valve
Issued 20 March 2014 Resolved
Ensure pressure vessel safeties properly installed and tested -- to include pressure switch and safety relief valve.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 25 July 2014
Resolution: A relief valve was installed on the pressure vessel. The compressor was only able to achieve approximately 38 psi (relief valve set at 125 psi; MAWP of pressure vessel is 200 psi). Test results for relief valve were provided dated May 2014.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 20 March 2014 Resolved
Cargo pump prime mover inoperable. Prove operation of prime mover and emergency shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2014
Resolution: Both L/O and F/O cargo pumps were operable and remote shutdowns operated as intended.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 March 2014 Resolved
Prove test of cargo discharge piping for tightness at MAWP.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 25 July 2014
Resolution: All L/O and F/O cargo piping was hydrostatically tested on 07/08/14 @ 225 PSI.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 20 March 2014 Resolved
Update line diagram to accurately reflect removal of slop oil pump.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 25 July 2014
Resolution: Line diagram of transfer system was upadated to reflect changes.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 8 July 2013 Resolved
Emergency shutdown will not operate properly.
Condition: Damaged By Earlier Event
Due 15 July 2013
Resolved 15 July 2013
Resolution: Adjusted cable
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 8 July 2013 Resolved
Test was completed; however, test date stencil missing. Corrected on the spot
Condition: Improper Installation
Due 8 July 2013
Resolved 8 July 2013
Resolution: Corrected on the spot
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 8 July 2013 Resolved
Secondary high alarm system inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2013
Resolution: Secondary alarm wiring repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 July 2013 Resolved
On 7/3/2013 offload of cargo occurred with and expired COI. New COI was issued on 7/8/2013 and no cargo operation occurred after initial incident.
Due 31 July 2013
Resolved 15 July 2013
Resolution: New COI issued
Electrical › Electric Supply System (service) › Cable
Issued 28 June 2010 Resolved
Multiple conduit connections loose and or pulled apart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2010
Resolved 6 July 2010
Electrical › Electric Supply System (service) › Cable
Issued 28 June 2010 Resolved
Properly support hanging cable thoughout vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2010
Resolved 6 July 2010
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 June 2010 Resolved
Repaint draft marks
Action required: 705 - Other - as specified
Due 28 July 2010
Resolved 6 July 2010
Pollution Prevention/Response › Response Equipment › Sorbents
Issued 18 June 2010 Resolved
Replenish contents of spill kit
Action required: 705 - Other - as specified
Due 5 July 2010
Resolved 6 July 2010
Communications › Visual Communication › Warning Sign (gangway)
Issued 18 June 2010 Resolved
Repaint or replace worn Warning sign
Action required: 705 - Other - as specified
Due 5 July 2010
Resolved 6 July 2010
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 18 June 2010 Resolved
Provide chaffing gear for fuel hose on diesel pump prime mover.
Action required: 705 - Other - as specified
Due 5 July 2010
Resolved 6 July 2010
Engineering › Reduction Gearing/Clutches › Bearing, Line Shaft
Issued 18 June 2010 Resolved
Adjust power take off on diesel prime mover
Action required: 705 - Other - as specified
Due 5 July 2010
Resolved 6 July 2010
Stability › Watertight Integrity › General
Issued 18 June 2010 Resolved
Determien source of excessive water in stern void.
Action required: 705 - Other - as specified
Due 29 June 2010
Resolved 6 July 2010
Resolution: cut out and renewed section
Deck/Cargo › Cargo Stowage › General
Issued 19 June 2008 Resolved
Two dogs and one gasket required replacement on cargo hatches.
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 24 June 2008
Resolution: Gasket & dogs changed out.
Engineering › Fuel Oil Service System › Hose
Issued 19 June 2008 Resolved
Prime mover fuel hose does not meet SAE J-1942 rating.
Action required: 705 - Other - as specified
Due 19 August 2008
Resolved 21 July 2008
Resolution: New hoses meeting rating installed.
Electrical › Electric Generation Source (service) › Generator
Issued 11 June 2007 Resolved
Install CG Approved Marine Alternators on barges fuel transfer pump engine and power generator engine.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 3 August 2007
Resolution: Vessel will carry only products with flashpoint of 140 degrees or higher. See documents
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 11 June 2007 Resolved
Repair wasted 3" fill/sounding pipe (open to the atmosphere) on top of the port side independant potable water tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2007
Resolved 3 August 2007
Resolution: sounding pipe cut and capped in satisfactory manner
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 June 2007 Resolved
Renew vessels' draft marks at next dry dock availability.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 2 April 2009
Resolution: Draft marks re-painted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 June 2007 Resolved
Vessel operator failed to have vessel inspected within 90 days after anniversary date of COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2007
Resolution: Barge missed 2006 annual inspection case sent to units'' IO shop.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 August 2005 Resolved
Plastic wire ties and electrical tape had been used to secure woven electrical conduit to overhead structure. Improper fasteners were required to be replaced with metal fasteners.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2005
Resolved 27 October 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 31 August 2005 Resolved
Paint used for draft marks was not contrasting with hull color. Black paint was used on a black hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2005
Resolved 27 October 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 31 August 2005 Resolved
Emergency Shut down for lube oil pump engine did not shut down the engine when activated.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2005
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 31 August 2005 Resolved
MSDS for gear and hydraulic oil not on board vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2005
Resolved 27 October 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 31 August 2005 Resolved
No guard over moving engine belts on lube oil pump engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2005
Resolved 27 October 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 31 August 2005 Resolved
Battery cover missing from battery box for the potable water pump engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 October 2005
Resolved 27 October 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 31 August 2005 Resolved
Exhaust manifold piping on engine for fuel pump prime mover did not have appropriate protection/guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2005
Resolved 27 October 2005
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 31 August 2005 Resolved
Exhaust manifold piping on engine generator did not have appropriate protection/guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2005
Resolved 27 October 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 11 August 2004 Resolved
Prove proper operation of tank level indicator alarm system.
Due 12 September 2004
Resolved 8 September 2004
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 11 August 2004 Resolved
Properly update barge transfer diagram to show location of all valves.
Due 18 August 2004
Resolved 8 September 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 July 2004 Resolved
Prope proper operation of slop oil transfer pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2004
Resolved 11 August 2004
Personnel › Training › Tank Barge Dangerous Liquids
Issued 7 July 2004 Resolved
Properly train all tankerman on the slop oil transfer system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2004
Resolved 11 August 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 7 July 2004 Resolved
Properly label all transfer pump emergency shut downs.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2004
Resolved 11 August 2004
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 7 July 2004 Resolved
Provide updated transfer procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2004
Resolved 11 August 2004
Electrical › Electrical Distribution System (emergency) › Switch
Issued 15 June 2004 Resolved
Explosion proof emergency kill switch to slop tank pump missing.
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 21 July 2004
Resolved 11 August 2004
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 15 June 2004 Resolved
Barge diagram does not reflect modifications made while in the yards.
Due 21 July 2004
Resolved 11 August 2004
Stability › Watertight Integrity › Weathertight Enclosure
Issued 15 June 2004 Resolved
Stbd hatch cover in need of repair.
Due 21 July 2004
Resolved 11 August 2004
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 15 June 2004 Resolved
Replace gasket to #1 stbd ullage hatch.
Due 21 July 2004
Resolved 11 August 2004
Stability
Issued 13 May 2004 Resolved
Deadweight survey conducted. Awaiting results from MSC.
Action required: 705 - Other - as specified
Due 13 May 2004
Resolved 13 May 2004
Stability › Watertight Integrity
Issued 3 October 2003 Resolved
Make temporary repairs to the side shell (port side). Weld cracks on the exterior and interior in port voids #1 and 2. The above requirement shall be completed to the satisfaction of the attending marine inspector prior to conducting transfer operations. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2003
Resolved 6 October 2003
Stability › Watertight Integrity
Issued 3 October 2003 Resolved
Make permanent repair to the side shell (port & stbd) at next hull exam scheduled for March 2004. The above requirement shall be completed to the satisfaction of the atttending marine inspector at next creditied hull exam. LEGACY COMPONENT DESC: Side shell
Condition: Damaged By Earlier Event
Due 30 March 2004
Resolved 1 May 2004
Electrical › Electric Generation Source (service)
Issued 28 January 2003 Resolved
Renew Positive and Negative Conductors on the starter for the Cargo pump prime mover. Ensure crimp type connectors and marine approved cable is used. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Due 28 February 2003
Resolved 11 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 May 2002 Resolved
Prove proper operation of cargo pump emergency shut down, prior to loading or unloading next vesel cargo. The above requirement shall be completed to the satisfaction of the attending marine inspector LEGACY COMPONENT DESC: Cargo Pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2002
Construction/Loadline
Issued 20 November 2001 Resolved
THE NEXT TIME BARGE IS GAS FREE MAKE REPAIRS TO FRACTURE ON LOCATED ON STARBOARD BOW CORNER.
Condition: Unknown
Due 31 March 2004
Resolved 1 May 2004
Electrical
Issued 28 November 2000 Resolved
Prove proper operation of vessel's generator.
Condition: Unknown
Due 28 November 2000
Resolved 28 November 2000
Construction/Loadline
Issued 28 November 2000 Resolved
Repair small fracture in port side deck edge, located amidships.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Deck/Cargo
Issued 28 November 2000 Resolved
Replace or bench test air tank relief valve.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Documentation
Issued 28 November 2000 Resolved
Provide plans for deckhouse modifications.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Deck/Cargo
Issued 2 December 1998 Resolved
Properly test pressure relief valves (2) on pressure vessel and _x001C_ properly test relief valve on cargo piping.
Condition: Unknown
Due 2 December 1998
Resolved 2 December 1998
Electrical
Issued 1 December 1995 Resolved
REPLACE COVER ON STARTING BATTERY FOR F/W TRANSFER PUMP.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Electrical
Issued 1 December 1995 Resolved
INSTALL COVER ON ELECTRICAL JUNCTION BOX IN OVERHEAD ABOVE F/O TRANSFER PUMP.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Deck/Cargo
Issued 1 December 1995 Resolved
SHOW PROPER OPERATIONS OF EMEGENCY SHUT DOWN ON F/O TRANSFER PUMP.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Electrical
Issued 1 December 1995 Resolved
REPLACE ALL NYLON WIRE TIES WITH METAL.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Construction/Loadline
Issued 27 November 1989 Resolved
SECURE CHAIN ON #2 VOID HATCH COVER, PORT SIDE
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Deck/Cargo
Issued 27 November 1989 Resolved
CONDUCT SATISFACTORY TEST OF EMERGENCY SHUTDOWN ON CARGO PUMP, PORTSIDE, TOTHE SATISFACTION OF ATTENDING MARINE INSPECTOR AND PRIOR TO NEXT DISCHARGE FROM LUBE OIL TANKS
Condition: Unknown
Due 27 November 1989
Resolved 27 November 1989
Construction/Loadline
Issued 14 June 1989 Resolved
OFFL0AD, GAS FREE AND DRYDOCK BARGE, MAKE PERMANENT REPAIR TO FRACTURED OR DAMAGED HULL AREA IN THE FORWARD AREA OF THE VESSEL, PRIOR TO THE CARRAGE OF CARGO.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Deck/Cargo
Issued 30 December 1986 Resolved
MARK ENGINE EMERGENCY SHUTDOWN SIGN.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Electrical
Issued 30 December 1986 Resolved
PROVIDE BATTERY BOXES FOR ENGINE STARTING BATTERIES ON CARGO PUMP ENGINE, LUBE OIL PUMP ENGINE AND WATER TRANSFER PUMP ENGINE. BOXES TO BE LINED WITHNON CONDUCTIVE MATERIAL OR CONSTRUCTED OF NON CONDUCTIVE MATERIAL.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.