MAURY USCG vessel records
← All vessels

WARNER SUPPLY

Built
1981
Last inspected
29 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 29 September 2025
…with no type recorded19
Operational controls None recorded without a removal date
Years with a record 42 calendar years (1983–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-53091

Documentation record

Registered dimensions (L × B × D)195.0 ft × 50.0 ft × 9.4 ft
Registered tonnagegross 1,012 / net 1,012
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST LOUIS SHIP DIV OF POTT · ST LOUIS, MO, UNITED STATES · built 1981
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDETROIT, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 4 March 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1012 - Regulatory (Subpart C or D), Gross Ton
1012 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 76 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 76

29 September 2025 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8240980
10 October 2024 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8017204
5 September 2024 Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7996649
16 October 2023 Periodic Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7809324
6 April 2023 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7665799
24 October 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7582631
4 October 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7326057
9 April 2020 Deficiency Check · COI Inspection · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6937394
20 December 2019 Hull Examination · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6875694
25 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293842
16 November 2016 Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6042475
27 January 2016 Examination of Repairs · Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5805457
7 December 2015 Annual Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5776986
15 May 2014 MTSA Verification · Damage Survey · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4859411
12 May 2014 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4856670
7 November 2013 Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4749138
15 May 2012 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4311830
1 February 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4236289
24 January 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4231316
31 August 2011 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4132823
1 June 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4032655
20 April 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3720623
10 September 2009 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3591825
7 May 2009 MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3469444
23 February 2009 Annual Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3422365
17 March 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3166101
2 May 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2924181
22 August 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2789101
26 April 2006 MTSA Verification · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2634189
23 February 2005 MTSA Verification · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2297637
28 June 2004 Internal Structural Exam · Hull Examination · Cargo Tank Internal · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2114087
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997013
6 June 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1810913
17 July 2002 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1647627
17 July 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1647973
23 April 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1608074
23 April 2001 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1444504
25 April 2000 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 816908
6 July 1999 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1091642
10 June 1999 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 805664
10 July 1998 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1129794
20 May 1998 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 794406
11 May 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1128902
25 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448940
13 June 1997 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1110660
1 July 1996 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1084325
1 June 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 506960
23 May 1996 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1085533
2 November 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 11161
16 August 1995 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 875395
22 June 1994 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1331215
1 July 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451875
13 November 1992 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 962178
13 August 1992 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 951670
26 August 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939022
9 July 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 513396
12 March 1991 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 924623
15 December 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1240791
16 November 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 488755
20 September 1990 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1242658
14 August 1989 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 891460
12 December 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 897672
18 November 1988 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 894827
26 September 1988 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1196392
12 April 1988 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 457630
4 November 1987 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 478660
11 August 1987 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1030387
10 August 1987 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1029415
26 May 1987 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1333998
22 May 1987 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1337400
31 July 1986 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1304146
24 March 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 496465
28 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300739
8 August 1985 Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 983577
3 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285863
7 June 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1273840

Deficiency record · 30

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2025 Resolved
For visual inspection, access plates and manholes must be removed as required by the marine inspector and the heater and combustion chambers must be thoroughly cooled and cleaned. Make the Thermal Fluid Heater (TFH) open and ready for inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 15 October 2025
Resolution: Opened and inspected
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 September 2025 Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. Test Cargo pump relief valves.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 10 November 2025
Resolution: Operator submitted evidence of annual testing.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 29 September 2025 Resolved
All marine employers must submit drug testing program data. Provide list of all employees enrolled in the DAPI program, and proof of any new hire testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 10 November 2025
Resolution: Operator submitted evidence of DAPI program enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 October 2024 Resolved
Ring Lifebouy name missing. Re-stencil name of vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2024
Resolved 25 November 2024
Resolution: Received email from vessel rep, lifebouy was replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 October 2024 Resolved
Cargo hose not labeled. Label or remove hose from vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2024
Resolved 25 November 2024
Resolution: Received email and photo from vessel rep, cargo hose was removed from vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 October 2023 Resolved
Vessel shall have 24hr contact numbers for Company and vessel security officers. The CSO number was out of service, vessel shall update phone number.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 27 October 2023
Resolution: CSO number updated.
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 16 October 2023 Resolved
The cargo handling equipment shall be maintained by the tank vessel's personnel in accordance with the regulations in this subchapter, including the following:(b) Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. (c) Cargo pump pressure gage shall be tested at least once a year for accuracy. Test records do not reflect accurate name of vessel nor full date of test for relief valves. Provide manufacturer data confirming set pressure, test procedures/documentation, and updated record with accurate data. Gauges have no record of testing. Provide record of testing.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 27 October 2023
Resolution: Vessel provided proof of gauge testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 October 2023 Resolved
The inspection for certification shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the structure, boilers, and other pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, life-saving appliances, fire-detecting and extinguishing equipment, pilot boarding equipment, and other equipment is in satisfactory condition and fit for the service for which it is intended. Oil found on and around cargo pump with saturated absorbent mat found on deck below pump. Oil mixed with standing water within coaming. Safely remove oily water from vessel, remove saturated material, and ensure cargo pump is leak free.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 27 October 2023
Resolution: Company provided updated gauge testing log.
14 - Pollution Prevention › 141 - MARPOL Annex I › Standard discharge connection
Issued 16 October 2023 Resolved
No person shall conduct an oil or hazardous material transfer operation unless:The discharge containment required by §§ 154.530, 155.310, and 155.320 of this chapter, as applicable, is in place and periodically drained to provide the required capacity. Discharge containment found with excessive standing water. Drain water prior to transfer of cargo. Ensure water is drained prior to future transfers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 27 October 2023
Resolution: Vessel cleaned area.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 October 2023 Resolved
Vessel shall make the thermal heater availble for visual inspection, operational testing, and provide test procedures.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2023
Resolved 8 November 2023
Resolution: Witnessed testing.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 24 October 2022 Resolved
Mechanical means of closing each drain and scupper within the coaming. Aft STBD containment was missing plug. Obtain and install plug. CITE 33 CFR 155.310(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 26 October 2022
Resolution: Installed plug.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2022 Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. Retro-reflective tape on both lifebuoys had worn. Replace retro-reflective tape. CITE 46 CFR 31.36-1 46 CFR 199.70(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 28 October 2022
Resolution: Replaced retro-relfective tape.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2022 Resolved
Electrical equipment must be arranged to prevent mechanical damage to the equipment from the accumulation of dust, oil vapours, steam or dripping liquids. Found multiple holes on the bottom of the 120 VAC 3 Phase "Delta" electrical panel in generator space. Plug holes. CITE 46 CFR 31.35-1 46 CFR 111.01-3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 4 November 2022
Resolution: Plugged holes in electrical panel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 October 2022 Resolved
Each cargo tank of a tank barge must have a high-level indicating device. The high-level indicating device must - Indicate visually the level of liquid in the cargo tank when the liquid level is within a range of 1 meter of the top of the tank. Cargo Tank #4 Port meter stick indicator was broken and was found to be not functioning. Tank is limited to 50% fill - approx. 962BBLS - till meter stick is replace and installed. CITE 33 CFR 155.480(b)(2)(iii) 46 CFR 39.2003(b)
Action required: 705 - Other - as specified
Resolved 4 November 2022
Resolution: Installed new meter stick indicator.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 October 2022 Resolved
Each cargo tank of a tank barge must have a high-level indicating device. The high-level indicating device must - Indicate visually the level of liquid in the cargo tank when the liquid level is within a range of 1 meter of the top of the tank. Cargo Tanks #1 and #3 meter stick indicator holding bands were not secured. Secure holding bands. CITE 33 CFR 155.480(b)(2)(iii) 46 CFR 39.2003(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 4 November 2022
Resolution: Secured cargo Tanks #1 and #3 meter stick indicator holding bands.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2021 Resolved
Electrical equipment must be arranged to prevent mechanical damage to the equipment from the accumulation of dust, oil vapours, steam or dripping liquids. Found multiple holes on the bottom of the 120 VAC 3 Phase "Delta" electrical panel in generator space. Plug holes. CITE 46 CFR 31.35-1 46 CFR 111.01-3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2021
Resolved 5 October 2021
Resolution: Holes were properly plugged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 October 2021 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the port required to be on the stern of the vessel. Name and hailing port on ring buoys were worn. Re-mark ring buoys. CITE 46 CFR 31.36-1 46 CFR 199.70(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2021
Resolved 5 October 2021
Resolution: Life buoys were re-marked with name and hailing port.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 October 2021 Resolved
Sidelights of vessel 20 meters or more in length shall be fitted with matt black inboard screens. Navigation light [port and starboard sidelights] screens were painted gray. Paint screens matt black. CITE 33 CFR 84.05
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2021
Resolved 5 October 2021
Resolution: Light screens were painted matt black.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 September 2020 Resolved
Vessel does not have valid Cargo Authority Attachment (CAA). Obtain CAA through Marine Safety Center. Cite: 46 CFR 30.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2020
Resolution: Vessel is not required to have a CAA due to type of cargo carriage and not having a VCS.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 September 2020 Resolved
The requirements of 58.10-5 (c), and (d) shall apply to diesel engine installations. During start of generator set, where exhaust flex hose and exhaust pipe connect, marine inspector witnessed visible black soot coming from connection - confirming leak in exhaust. Repair to satisfaction of local marine inspector. Cite: 46 CFR 31.30-1 46 CFR 58.10-10(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2020
Resolution: Welded exhaust pipe has been installed, witnessed operational test, appeared leak free.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 September 2020 Resolved
Exposed parts of freeboard deck must have guardrails at least 36" high above the deck. Railing for deck area is incomplete. Numerous courses were not installed. Complete installation of railings. Cite: 46 CFR 31.25-1 46 CFR 45.115
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2020
Resolution: Railing installation completed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 30 September 2020 Resolved
During cargo transfer operations, inland oil barges must have appropriate equipment and supplies ready for immediate use to control and remove on-deck oil cargo spills of at least one barrel. Spill kit was not available for inspection. Place spill kit on board and have readily available for inspection. Cite: 33 CFR 155.215(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2020
Resolution: 6 OCT 2020 spill kit has been placed on board missing inventory list. 6 NOV 2020 inventory list provided
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 25 October 2017 Resolved
Certificate of Financial Responsibility Still pending.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2017
Resolved 26 October 2017
Resolution: Company provided proof of valid COFR.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 April 2006 Resolved
During the period of 24April to 27April the CBC196 was operating with an invalid COI.
Due 27 April 2006
Resolved 27 April 2006
Resolution: Conducted inspection for certification. Issued temporary COI.
Construction/Loadline
Issued 20 May 1998 Resolved
BARGE IS TO PROCEED DIRECTLY TO CHICAGO, IL AND DISCHARGE CARGO. PRIOR TO LOADING CARGO, MAKE PROPER PERMENENT REPAIRS TO 4" FRACTURE IN SIDESHELL SEAM IN #3 PORT VOID. REPAIRS ARE TO MADE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Construction/Loadline
Issued 13 August 1992 Resolved
BOW RAKE HATCH COVER GASKET WAS NOT PROPERLY SEATED.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Deck/Cargo
Issued 13 August 1992 Resolved
REMOTE MANUAL SHUT DOWN STATION NOT CONSPICUOUSLY MARKED. SIGN WAS DETERIORATED.
Condition: Unknown
Due 31 August 1992
Resolved 31 August 1992
Deck/Cargo
Issued 26 August 1991 Resolved
PRIOR TO THE USE OF THE CARGO PUMP ENGINE PROVE PROPER OPERATION OF THE EMERGENCY SHUTDOWN IN ACCORDANCE WITH 46 CFR 32.50-35.
Condition: Unknown
Due 3 September 1991
Resolved 3 September 1991
Deck/Cargo
Issued 26 September 1988 Resolved
REPLACE FUEL HOSES ON PUMP ENGINE WITH ONES THAT ARE MADE UP WITH PRESSURE TYPE FITTINGS. REPAIRS ARE TO BE MADE TO THE SATISFACTION OF THE ATTENDING U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 26 September 1988
Resolved 26 September 1988
Deck/Cargo
Issued 31 July 1986 Resolved
PRIOR TO LOADING NEXT CARGO BUT NOT LATER THAN THE COMPLIANCE DATE, GAS FREE THE CARGO TANKS FOR INTERNAL INSPECTION BY A USCG MARINE INSPECTOR
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986

Recorded names · 1

CBC 196 (2006–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.