TEXSUN II

TEXSUN II is a 1974 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1981, most recently in February 2026, along with 43 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2010 and 2016.

Records from 1981 to 2026. Most recent: inspection, 10 February 2026.

Built
1974
Last inspected
10 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUR2914
Flag
UNITED STATES
366934780
Maury page id
psix-53275

Inspections, by type

…with no type recorded14
Years with a record 42 calendar years (1981–2026)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.2 ft × 20.0 ft × 7.5 ft
Registered tonnagegross 73 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT · LOREAUVILLE, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP8405MMSI 366934780 · active · compulsorily equipped · granted 12 October 2024, expires 12 October 2034
WUR2914MMSI 366934780 · expired · compulsorily equipped · granted 14 March 2014, cancelled 15 June 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NAUTILUS Passenger (Inspected) · MISLE 51268 · 27 January 2010 · activity 3670679

Inspection history · 73

10 February 2026 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8308746
29 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8303382
7 February 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8076324
30 January 2024 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7858038
24 January 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7853950
9 November 2022 COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7589101
14 January 2022 Drydock Exam · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7380592
13 January 2021 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7123928
12 June 2020 Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 6978034
2 June 2020 Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 6967505
26 May 2020 Simplified Stability Test
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6960887
13 March 2020 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6929134
9 January 2020 Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6885878
9 January 2019 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6607924
28 April 2018 Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 6404868
26 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6361837
11 January 2018 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6336592
13 November 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6305336
5 January 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6066624
27 December 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6080360
9 February 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5812978
8 January 2016 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5794079
23 January 2012 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4229815
19 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4227493
30 December 2011 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4216230
7 January 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3965296
27 January 2010 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3670679
12 January 2010 Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3662806
2 March 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3427488
17 January 2008 Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3135897
6 December 2007 COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3110482
30 January 2007 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2864223
21 March 2006 Re-Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2606436
24 January 2006 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2576991
6 January 2006 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2562118
28 March 2005 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2320150
15 March 2004 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2022814
5 January 2004 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1968754
2 January 2003 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1722621
7 January 2002 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1483138
26 March 2001 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1064619
2 March 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1429492
2 February 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 814391
4 January 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418641
27 May 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411887
13 May 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468854
15 December 1997 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1465346
1 May 1997 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463308
23 June 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 98830
8 May 1996 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1367770
17 May 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1417775
8 December 1994 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1465803
12 May 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1171074
21 May 1993 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 834125
6 June 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 15501
21 May 1992 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 945256
7 April 1992 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 951204
23 May 1991 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1233515
31 May 1990 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 923055
31 January 1990 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 910806
5 January 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913370
7 June 1989 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1352553
6 October 1988 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1198126
2 June 1988 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 892942
9 April 1987 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1332114
26 March 1986 Re-Inspection · Credit Drydock
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 996729
21 September 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 986406
5 June 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 978202
11 May 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974236
29 March 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973075
29 March 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 963704
16 June 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1277629
11 September 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 964866

Deficiency record · 43

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 February 2025 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The painter must: have a breaking strength of at least 1,500 pounds. Marine inspectors noted dry rotted painter lines on life saving configurations. 46 CFR 180.175(f)(3) (ii)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2025
Resolved 6 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 February 2025 Resolved
In addition to meeting 180.130, each life float and buoyant apparatus must be stowed as required under this section, of proper strength for the size of life float or buoyant apparatus as indicated on its identification tag. Marine inspectors noted missing identification tag on port side life float assembly. 46 CFR 180.137(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2025
Resolved 6 March 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 February 2025 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily available on board to determine presence of alcohol. Alcohol test strips were expired. 46 CFR 185.212 46 CFR 4.06-15(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2025
Resolved 6 March 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 February 2025 Resolved
Where the length of the compartment is less than 12 feet, one vertical means of escape will be acceptable. Engine room is greater than 12 feet requiring more than one vertical means of escape. Marine Inspectors observed seized emergency escape hatch for engine room. 46 CFR 177.15-1(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2025
Resolved 6 March 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 30 January 2024 No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks. During the Internal Structural Exam conducted on 24JAN2024, Marine Inspectors identified cracking on the watertight bulkhead separating the rudder room from the machinery space. Cracking is concentrated around the STBD main engine exhaust bulkhead fitting. Submit repair proposal to [email withheld] and once USCG approval is granted, complete repairs during next scheduled dry docking.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 January 2021 Resolved
Each item of survival equipment must be of good quality, and efficient for the purpose it is intended to serve. Inspector found 01 life float lights inoperable due to faulty battery. Replace battery and prove operation to satisfaction of Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2021
Resolved 14 January 2021
Resolution: Vessel replaced battery, MI op-tested, test sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 January 2021 Resolved
Electrical installations on vessels shall be such that (i) services essential for safety will be maintained under various emergency conditions, and (ii) the safety of passengers, crew, and vessel from electrical hazards will be assured. MI observed 9 connections at each battery terminal under the console servicing navigation equipment. Effect repairs reducing the electrical hazard to the satisfaction of the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2021
Resolved 14 January 2021
Resolution: Electrician wired in terminal block and installed secondary battery. MI observed repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 January 2020 Resolved
EACH RING LIFE BUOY ON A VESSEL MUST BE APPROVED IN ACCORDANCE WITH 46 CFR 160.050 IN SUBCHAPTER Q. VESSEL HAD 02 LIFE BUOYS THAT WERE WATER LOGGED. VESSEL MUST REPLACE 02 LIFE BUOYS TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 23 January 2020
Resolution: Vessel provided a new life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 9 January 2020 Resolved
THE MEANS USED TO ATTACH THE FLOAT-FREE LINK TO THE VESSEL MUST BE RESISTANT TO DETORIORATION FROM THE ULTRAVOILET LIGHT. 01 LIFE-FLOATS LINES WERE FOUND TO BE DETRIOATED AND MUST BE REPLACED TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 23 January 2020
Resolution: Vessel replaced life-float lines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020 Resolved
REMOTE FUEL SHUTOFF STATIONS MUST BE MARKED IN CLEARLY LEGIBLE LETTERS AT LEAST 1 INCH HIGH INDICATING PURPOSE OF THE VALVE AND DIRECTION OF OPERATION.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 23 January 2020
Resolution: Vessel affixed new sign for fuel shut off.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 9 January 2020 Resolved
A DURABLE PLACARD MUST BE POSTED NEXT TO ALL RADIOTELEPHONE INSTALLATIONS WITH THE EMERGENCY BROADCAST INSTRUCTIONS AND INFORMATION SPECIFIC TO THE INDIVIDUAL VESSEL. THE ONBOARD INSTRUCTIONS WERE NOT SPECIFIC TO THE VESSEL AND MUST INCLUDE VESSEL SPECIFICS TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 23 January 2020
Resolution: Vessel provided new instructions specific to the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 January 2020 Resolved
INTERNAL COMBUSTION ENGINE EXHAUST AND SIMILAR SOURCES OF IGNITION MUST BE KEPY CLEAR OF AND SUITABLY INSULATED FROM COMBUSTIBLE MATERIAL. BOTH ENGINE EXHAUST INSULATION MUST BE RE-APPLIED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 23 January 2020
Resolution: Vessel supplied new insulation to the exhaust.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 January 2020 Resolved
EACH LADDER USED AS A MEANS OF ESCAPE MUST BE MOUNTED AT LEAST 7 INCHES FROM THE NEAREST PERMANENT OBJECT IN BACK OF THE LADDER. THE ESCAPE LADDER IN THE MALE HEAD WAS NOT SECURELY FASTENED. VESSEL MUST SECURE THE ESCAPE LADDER TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 23 January 2020
Resolution: Vessel secured escape ladder.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020 Resolved
FLEXIBLE HOSE RUNS MUST BE VISIBLE, EASILY ACCESSIBLE , PROTECTED FROM MECHANICAL DAMAGE. CHAFFING WAS NOTED IN THE HYDRAULIC LINES. VESSEL MUST SECURE THE HYDRAULIC LINES TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 23 January 2020
Resolution: Vessel secured hydraulic lines.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 9 January 2020 Resolved
EACH POTABLE WATER TANK SHALL BE PROVIDED WITH A MEANS TO PREVENT ENTRANCE INTO THE TANK OF ANY CONTAMINATING SUBSTANCE. VESSEL MUST REPLACE THE FRESH WATER SCREEN TO THE SATISFACTION OF THE MARINE INSPECTOR. 21 CFR 1250.82(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 19 March 2020
Resolution: Vessel added screen to water tank pipe.
Construction/Loadline › Structures › Ventilators
Issued 5 January 2017 Resolved
Repair holes in starboard side ventilation enclosures preventing vents from closing.
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 23 January 2017
Resolution: Holes in starboard side vent box have been sealed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 January 2017 Resolved
Repair FCC-approved RADAR.
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 14 February 2017
Resolution: Radar repaired.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 January 2017 Resolved
Replace junction box on lifefloat deck.
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 23 January 2017
Resolution: Removed unused junction box on life float deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 January 2017 Resolved
Remove dead-end wires in center compartment or provide suitable enclosure.
Action required: 705 - Other - as specified
Due 5 January 2017
Resolved 23 January 2017
Resolution: Dead end wires place within proper enclosure.
Fire Fighting › Fire Pumps › Power Source
Issued 5 January 2017 Resolved
Prove proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2017
Resolution: Test of fire pump conducted.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 January 2011 Resolved
Port engine exhaust leak
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2011
Resolved 18 January 2011
Resolution: Repaired exhaust leak with proper connection.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 7 January 2011 Resolved
Life jacket lights did not work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2011
Resolved 18 January 2011
Resolution: Operated and checked life jacket lights
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 7 January 2011 Resolved
Misssing nav rules
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2011
Resolved 18 January 2011
Resolution: Verified copy of nav rules onboard.
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2010 Resolved
Engine room bilge under port and starboard shafts under shaft seal area has corrosion. Require crop and renew or provide gauging report.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2010
Resolved 28 April 2010
Resolution: pitted hull plating was UT gauged and proved to within tolerances
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 January 2010 Resolved
Aft house bulk head new main deck has a couple of hole in bulk head. Required POC to remove panalling inside house to get a better look at how much metal is wasted. Cut out damage area and weld in new plate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2010
Resolved 28 April 2010
Resolution: Holes were from a previously mounted life ring bracket. Holes were clad welded.
Stability › Watertight Integrity › General
Issued 12 January 2010 Resolved
Bulk head penatrations for port side engine throttle cables on forward engineroom bulk head need replacing.
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 28 April 2010
Resolution: Verified renewal of compression washers and packing.
Construction/Loadline › Hull › Weld
Issued 12 January 2010 Resolved
2 welds in the forward peak tank were fractured. Required POC to gouge out and reweld
Action required: 705 - Other - as specified
Due 12 February 2010
Resolved 28 April 2010
Resolution: Verified weld repairs
Lifesaving › Lifefloat › Painter
Issued 2 March 2009 Resolved
Replace painter line on starboard, top life float.
Action required: 705 - Other - as specified
Due 16 March 2009
Resolved 1 April 2009
Engineering › Bilge Water Management System › Strainer
Issued 2 March 2009 Resolved
Make all strainer openings capable of taking suction by increasing opening size to three times pipe diameter opening.
Action required: 705 - Other - as specified
Due 2 April 2009
Resolved 1 April 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2009 Resolved
Terminate dead end wire in steering component in port overhead.
Action required: 705 - Other - as specified
Due 2 April 2009
Resolved 1 April 2009
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2002 Resolved
Crop and renew bottom plating where excessive pitting has occured.
Due 31 January 2002
Resolved 11 January 2002
Deck/Cargo
Issued 2 March 2001 Resolved
Provide means of attaching all hatch covers according to 46 CFR 179.360 (a)(2).
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 2 March 2001 Resolved
Label both sides of emergency hatch in way of engineroom according to 46CFR185.606.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Electrical
Issued 2 March 2001 Resolved
Provide means to prevent chafing of throttle cable where cable passes through forward machinery space, aft bulkhead.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Navigation
Issued 4 January 2000 Resolved
Provide on board a Compass Deviation Card.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Documentation
Issued 4 January 2000 Resolved
Provide an Employee Assistance Program and associated training for the crewas required by 46 CFR subchapter A, part 16.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Documentation
Issued 4 January 2000 Resolved
Provide on board a valid FCC Radio Safety Certificate.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Construction/Loadline
Issued 5 January 1990 Resolved
GUAGE PLATE IN WAY OF PORT AND STARBOARD A/C UNITS, AND REPLACE AS REQUIREDBY LOCAL OCMI OR ATTENDING INSPECTOR.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Construction/Loadline
Issued 5 January 1990 Resolved
MAKE DECK IN WAY OF PORT AND STARBOARD HEADS ACCESSIBLE FOR INSPECTION OR PROVIDE METHOD TO DETERMINE SOUNDNESS OF DECK PLATING.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Construction/Loadline
Issued 11 May 1984 Resolved
REPLACE ALL HATCH COVER GASKETS ON MAIN DECK.
Condition: Unknown
Due 9 June 1984
Resolved 11 May 1984
Lifesaving
Issued 11 May 1984 Resolved
PROVIDE PFD DONNING INSTRUCTIONS.
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984
Navigation
Issued 11 May 1984 Resolved
REPLACE BATTERY ON EPIRB.
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984
Navigation
Issued 11 May 1984 Resolved
PROVIDE COMPASS DEVIATION TABLE.
Condition: Unknown
Due 11 May 1984
Resolved 11 May 1984

Casualty record · 2

27 January 2010Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3670679
27 December 2016Routine · role: Involved in a Marine Investigation (non-casualty) · activity 6080360
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.