Inspection history · 32
12 February 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3146460
11 February 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3148162
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999706
27 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289707
7 February 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1046017
4 February 1999
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1360735
2 February 1998
Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372296
21 March 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1106990
7 February 1997
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363963
5 February 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1104109
24 January 1996
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1396545
18 April 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 853005
13 January 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405649
31 March 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374009
28 January 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449578
19 January 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826850
10 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 126740
5 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 952751
22 January 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 945175
19 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232038
30 January 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927651
29 January 1991
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924813
7 March 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 892127
8 June 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896171
4 March 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027425
11 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331460
13 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021062
12 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325392
8 November 1986
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023514
6 March 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001508
31 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973103
8 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274141
Deck/Cargo
Issued 4 February 1999
Resolved
Install overfill devices on each cargo tank in accordance with 33 CFR 155.480.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Lifesaving
Issued 7 February 1997
Resolved
PAINT HULL WITH VESSEL NAME, LOADLINE, DRAFT MARKS, OFFICIAL NUMBER AND HAILING PORT IN CONTASTING COLORS.
Condition: Unknown
Due 7 March 1997
Resolved 21 March 1997
Fire Fighting
Issued 7 February 1997
Resolved
PLUG HOLES ON ENGINE ROOM VENTILATOR APPROXIMATELY 2' ABOVE MAIN DECK.
Condition: Unknown
Due 7 March 1997
Resolved 21 March 1997
Documentation
Issued 22 January 1992
Resolved
PROVIDE TRANSFER PROCEEDURES ONBOARD TANK BARGE.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Deck/Cargo
Issued 29 January 1991
Resolved
RENEW COMMON HEADER VENT SYSTEM AS PER ORIGINAL OR SUBMIT PROPOSAL TO OCMI_x001C_NEW ORLEANS FOR APPROVAL.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Deck/Cargo
Issued 29 January 1991
Resolved
INSTALL GOOSE NECK WITH WITH FLAME SCREEN ON COMMON HEADER VENT SYSTEM AS_x001C_ INTERIM MEASURE PENDING REVIEW OF PROPOSAL (ITEM 1) FOR SYSTEM BY OCMI NEW_x001C_ORLEANS.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Deck/Cargo
Issued 8 June 1988
Resolved
PROVIDE EVIDENCE THAT THE EXISTING OVERFLOW (PV VALVE) FOR THE CARGO TANKS AND CARGO PIPING IS OF AN APPROVED TYPE OR REPLAE WITH APPROVED PV VALVE, PROVE SATISFACTORY OPERATION OF THE SAME. (46 CFR 162.017)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
PROVIDE EVIDENCE THAT CARGO PIPING HAS BEEN HYDRO TESTED TO 1 1/2 TIMES ITS NORMAL WORKING PRESSURE. (46 CFR 32.50)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Documentation
Issued 8 June 1988
Resolved
REPAINT DRAFT MARKS. (46 CFR 32.05-1)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Documentation
Issued 8 June 1988
Resolved
REINSTALL THE WARNING SIGN "NO VISITORS, NO SMOKING, NO OPEN LIGHTS". (46 CFR 35.30-1)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
REPAIR INOPERATIVE LIQUID LEVEL GAUGING (CLOSED SYSTEM). (46 CFR 32.20-20)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
PROVIDE PLUG FOR THE CARGO MANIFOLD FIXED CONTAINMENT. (33 CFR 155.310)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
MARK CARGO HOSES "OIL SERVICE" AND PROVIDE DATE OF MANFACTURER OF HOSE AND EVIDENCE THAT HOSE HAS BEEN SATISFACTORILY HYDROED 1 1/2 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE. (33 CFR 156.170)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Electrical
Issued 8 June 1988
Resolved
REMOVE LOOSE WIRING IN VICINITY OF DECK SHACK.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Navigation
Issued 8 June 1988
Resolved
REPLACE SOCKETS AND BULBS IN NAVIGATION LIGHTS WITH AN APPROVED MARINE TYPE. REMOVE WATER FROM INSIDE THE FIXTURE AND MAKE IT WEATHERLIGHT.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Electrical
Issued 8 June 1988
Resolved
REMOVE SPLICED ELECTRICAL WIRE FOR THE STARBOARD RUNNING LIGHT OR PROVIDE A JUNCTION BOX APPROVED FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
REMOVE FLAME ARRESTOR ON THE CARGO PIPING VENT FOR VISUAL INSPECTION. (46 CFR 32.20-1, 64 CFR 162.016)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Electrical
Issued 8 June 1988
Resolved
PROVIDE BATTERY CHARGER FOR THE 12.VOLT BATTERY USED FOR THE NAVIGATION LIGHTS. (OLD "J" REGS)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Documentation
Issued 8 June 1988
Resolved
PROVIDE EVIDENCE OF A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY. NO CARGO IS TO BE LOADED UNTIL A VALID CERTIFICATE IS PROVIDED. (46 CFR 32.50-15(B))
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
FREE UP AND PROVE SATISFACTORY OPERATION OF THE (2) 6" CARGO PIPING MANIFOLD GATE VALVES. (46 CFR 32.50-15(B))
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Navigation
Issued 8 June 1988
Resolved
PAINT NAVIGATION LIGHT SCREENS FLAT BACK.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Electrical
Issued 8 June 1988
Resolved
REMOVE AND REPLACE WASTED CONDUIT FOR ELECTRICAL CABLE THROUGHOUT THE DECK OF THE BARGE.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Lifesaving
Issued 8 June 1988
Resolved
PROVIDE (2) USCG APPROVED RING BOUYS AND LINE AND PROPERTY MOUNT. (46 CFR 33.40-10)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Fire Fighting
Issued 8 June 1988
Resolved
PROVIDE (2) B-II PORTABLE FIRE EXTINGUISHERS. (46 CFR 34.50-10(A))
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Construction/Loadline
Issued 8 June 1988
Resolved
PROVIDE SUPPORTS FOR STEEL GRATING IN THE PMP COMPARTMENT; STERN RAKE, STBD SIDE. (46 CFR 32.01-10)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
REPLACE ALL DETERIORATED HAND WHEELS ON THE CARGO TANK VALVES, ALSO FREE VALVES WHICH ARE HARD TO OPEN/CLOSE. ADJUST VALVE OPEN/CLOSE INDICATORS. (46 CFR 32.50-15(B))
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
PROVIDE A SIGN MARKING THE LOCATION OF THE DIESEL ENGINE (CARGO PUMP) REMOTE SHTUTDOWN. (46 CFR 35.30-1)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988
Resolved
PROVIDE TWO FLAME C=SCREENS (30X30 MESH) FOR THE DIESEL FUEL TANK. (46 CFR 36.20-1)
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 November 1986
Resolved
HYDRO TEST CARGO PIPING TO 1 1/2 TIMES ITS NORMAL WORKING PRESSURE. CALIBRATE CARGO PUMP GAUGE IF REQUIRED AFTER TESTING. GAUGE MUST BE WITHIN 10%. IF THIS IS COMPLETED DURING COI PERIOD, PROVIDE DOCUMENTATION.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Electrical
Issued 8 November 1986
Resolved
SECURE GENERATOR WIRING UNDER GENERATOR STAND.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Navigation
Issued 8 November 1986
Resolved
REPAIR NAVIGATION LIGHT STANCHIONS PORT AND STARBOARD.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Construction/Loadline
Issued 8 November 1986
Resolved
REPAIR AS NECESSARY LIFE LINE STANCHIONS AND LIFELINES.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Electrical
Issued 8 November 1986
Resolved
REPAIR FLOOD LIGHTS, WIRING AND JUNCTION BOXES AS NEEDED, ALL REPAIRS TO BE IAW 46 CFR SUB CHAPTER "J" AND CLASS I DIV. II LIGHTS AND GENERATOR MAY BE REMOVED IF DESIRED.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Electrical
Issued 8 November 1986
Resolved
RENEW AS NEEDED THE DECK WIRING CONDUIT AND HOLD DOWN BRACKETS.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Electrical
Issued 8 November 1986
Resolved
REPAIR OR REPLACE IN KIND THE GENERATOR DISTRIBUTION PANEL.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Electrical
Issued 8 November 1986
Resolved
SECURE GENERATOR EXHAUST.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
REPAIR AS NECESSARY ALL DIESEL DECK MACHINERY AND DIESEL PUMP ENG FUEL LINES. ALL TO APPROVED TYPES.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
PROCURE FLAME SCREENS IN CIRCULAR FRAMES TO FIT ALL 9 CARGO TANK ULLAGE OPENINGS.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
MARK THE LOCATION OF THE DIESEL ENGINE (CARGO PUMP) REMOTE SHUTDOWN.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
REINSTALL THE 12 FT RISER ON THE COMMON VENT SYSTEM AND INSTALL FLAME SCREENS OR PRESSURE-VACCUM RELIEF VALVE OF APPROVED TYPE.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Lifesaving
Issued 8 November 1986
Resolved
REINSTALL LIFE-RINGS AND MOUNTING BRACKETS.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
REPACK STUFFING TUBES IN MAIN DECK FOR REACH RODS.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
REINSTALL THE WARNING SIGN "NO VISITORS, NO SMOKING, NO OPEN LIGHTS".
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
SECURE DECK GRATTING IN THE PUMP AND ENGINE ROOM.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Construction/Loadline
Issued 8 November 1986
Resolved
REPLACE MISSING OR BROKEN HATCH DOGS, PINS AND GASKETS AS NEEDED ON THE GARGO AND VOID WATER TIGHT CLOSURES.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
INSTALL FLAME SCREENS ON THE GOOSENECK VENTS TO THE PUMP ROOM.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
RENEW FLAME ARRESTOR ON CARGO PUMP PRIME MOVER DIESEL.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Construction/Loadline
Issued 8 November 1986
Resolved
REPAIR OR REPLACE THE WATER TIGHT HATCH COVERS OVER THE PUMP ROOM AND ENGINE ROOM.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
RENEW AS NEEDED THE COMMON HEADER VENT PIPING SUPPORT BRACKETS AND DECK MOUNTS.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Electrical
Issued 8 November 1986
Resolved
REPLACE LIGHT GLOBES AS NECESSARY AND REHANG THE WIRING IN THE CARGO PUMP ROOM. INSURE LIGHTS ARE THE PROPER TYPE FOR THE AREA (EXPLOSION PROOF).
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
REPAIR CARGO VENT SYSTEM RELIEF VALVE.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986
Deck/Cargo
Issued 8 November 1986
Resolved
REPAIR OR REPLACE ALL DIESEL ENGINE MONITORING GAUGES OIL, WATER, TACH ETC.
Condition: Unknown
Due 8 November 1986
Resolved 8 November 1986