Records from 1984 to 2014. Most recent: inspection, 18 March 2014.
Inspection history · 92
18 March 2014
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4818631
15 June 2012
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4344675
22 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4318498
5 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3863980
23 July 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3543591
1 July 2009
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3530026
3 February 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3443147
15 July 2008
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3267454
13 July 2007
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3000194
10 April 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2621114
26 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2281286
6 December 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2254176
24 November 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2256201
24 March 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2037099
17 November 2003
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1949119
11 September 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1907249
21 April 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1777819
28 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764328
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760070
14 December 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718979
15 May 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1616913
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607008
22 March 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495880
10 January 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1478059
24 September 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382395
18 July 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1068614
16 April 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1066454
4 March 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1429497
1 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815489
19 January 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426319
19 November 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 810496
20 September 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785510
28 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077824
29 March 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1115794
5 March 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801424
25 January 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788446
16 December 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1460258
5 November 1998
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1446703
1 October 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 47044
9 September 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 799317
4 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1131201
29 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129973
27 April 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1124684
21 January 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431904
29 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117918
21 March 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455463
30 September 1996
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1427271
4 May 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1088099
13 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 642744
25 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 81946
4 February 1996
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1459972
27 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193416
10 July 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882975
13 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187940
22 March 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459161
26 July 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 866826
27 May 1994
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 861104
8 April 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166578
10 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854249
28 January 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1163025
27 January 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161920
14 January 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1162047
22 November 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434058
26 March 1993
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1447229
23 December 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 139285
25 June 1992
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1269399
16 January 1992
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 943907
23 October 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1251354
2 September 1991
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1248252
1 April 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1223476
6 February 1991
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1231778
5 June 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1215439
23 January 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 917411
18 April 1989
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 892067
24 March 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1345494
18 January 1989
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 888496
30 November 1988
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1037883
23 November 1988
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037313
16 August 1988
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1036474
7 July 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208505
6 February 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338736
31 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314837
7 October 1986
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1020249
7 April 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1001492
24 March 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999860
6 February 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305557
5 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286953
12 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974429
23 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281383
12 April 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973424
14 February 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279316
14 February 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279317
Lifesaving › Lifeboat › Rigid Cover
Issued 18 March 2014
Resolved
L/B A inside overhead under the outboard davit brace was found to be fractured and L/B B has surface cracking in the same location. Both L/B canopies will be repair IAW manufacturer specification by the OEM. 79 MODU 10.1.3
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 June 2014
Resolved 11 July 2014
Resolution: Received email from Tessa (Compliance) from Hercules offshore with photo proof of the repair to L/B A and B. Repairs were completed by OEM.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 March 2014
Resolved
Embarkation lights for the lifeboats were found to have Sodium vapor which require a cool down and a warm up time which restricts them from coming on within the 45 second window that it takes for the emergency generator to come on line and take the emergency load. These lights must be changed out to allow for immediate illumination upon restoration of power.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 28 July 2014
Resolution: Received an email from [name withheld] with photos attesting to the replacement of the embarkation lights.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 15 June 2012
Resolved
A-60 Bulkhead insulation in the engine control room is torn, worn and missing in places. Replace worn areas with approved A-60 insulation & fasteners.
Action required: 705 - Other - as specified
Due 9 November 2012
Resolved 12 October 2012
Resolution: Received photos from rig and specifications on A-60 insulation installed in ECR.
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 June 2012
Resolved
Turbo drain line on the emergency generator is leaking. Repair the line so no oil is leaking in turbo area.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 14 August 2012
Resolution: Received photos from OIM showing repaired turbo line.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 15 June 2012
Resolved
The vessel did not have documentation for pressure vessel internal examination as per MOC Policy Letter 01-03 dated 18OCT2001. Required to provide documentation of P/V internal exam or have class conduct exam.
Action required: 705 - Other - as specified
Due 10 September 2012
Resolved 17 August 2012
Resolution: Received ABS Class survey showing pressure vessel exams.
Communications › Alarms/Indicators › General Alarm
Issued 15 June 2012
Resolved
Upon loss of power (due to testing emergency generator) gas detection system on rig floor became inoperable. Ensure proper operation of gas detection system on rig floor.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 10 August 2012
Resolution: Received notification from OIM onboard that 02 sensors in gas detection system had been replaced and system is not operating properly.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 July 2009
Resolved
Provide an Emergency Evacuation Plan for the current location of the MODU to the Local OCMI (Sector New Orleans) for review and approval.
Due 8 July 2009
Resolved 14 July 2009
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 1 July 2009
Resolved
Provide a copy of the Construction Portfolio onboard the MODU.
Due 15 July 2009
Resolved 14 July 2009
Construction/Loadline › Structures
Issued 17 November 2003
Resolved
CROP AND RENEW WASTED AREA/HOLES ABOVE TANK 5-CL/SACK ROOM DECK. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Due 13 December 2003
Resolved 11 December 2003
Construction/Loadline › Hull
Issued 17 November 2003
Resolved
CROP AND RENEW WASTED AREAS ON 7 VERTICAL AND 2 DECK STIFFENERS NEAR FWD BULKHEAD IN VOID TANK 7-P AND 7-S. LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Due 13 December 2003
Resolved 11 December 2003
Construction/Loadline › Hull › Bottom Plating
Issued 17 November 2003
Resolved
COMPLETE PHASE TWO OF SEILOD EXAM SWIM BY OF LEG TO MAT.
Condition: Unknown
Due 13 February 2004
Resolved 26 February 2004
Resolution: Completed SEILOD exam phase II
Accommodation/Occupational Safety
Issued 4 March 2001
Resolved
TEST ALL HIGH PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 3 April 2001
Resolved 27 March 2001
Engineering
Issued 4 March 2001
Resolved
CROP AND RENEW WASTED FUEL OIL TANK VENTS ON THE PORT SIDE.
Condition: Unknown
Due 4 March 2001
Resolved 4 March 2001
Electrical
Issued 4 March 2001
Resolved
REPLACE THE (3) THREE JUNCTION BOXES WITH WASTED COVERS IN THE MUD PIT ROOMINCLUDING THE DOOR INDICATING LIGHT FOR WTD #20.
Condition: Unknown
Due 3 April 2001
Resolved 27 March 2001
Fire Fighting
Issued 19 January 2000
Resolved
TRAIN AND CONDUCT SATISFACTORY FIRE AND BOAT DRILL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Engineering
Issued 19 January 2000
Resolved
REPLACE FLEX FUEL HOSE ON CEMENT UNIT WITH HARD PIPE, FLEX HOSE MAY NOT EXCEED 30". ALSO REPLACE FUEL HOSE ON #1 MAIN GEN.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Lifesaving
Issued 19 January 2000
Resolved
IMPLEMENT MEANS TO PROPERLY TRACK/RECORD LIFESAVING AND FIREFIGHTING TRAINING FOR REGULARLY ASSIGNED PERSONNEL IN ACCORDANCE WITH 46CFR109.213.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Electrical
Issued 16 December 1998
Resolved
FREE UP EMERGENCY GENERATOR LOUVERS & ENSURE PROPER OPERATION.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Construction/Loadline
Issued 16 December 1998
Resolved
CROP & RENEW ALL WASTED STEEL & RAILINGS ON DRILL FLOOR PRIOR TO CONDUCTINGDRILLING OPERATIONS ON NEXT WELL.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999
Electrical
Issued 16 December 1998
Resolved
REPLACE HIGH TEMP INDICATOR LIGHT ON #1 GENERATOR.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Engineering
Issued 16 December 1998
Resolved
REPAIR/REPLACE EMERG GEN FUEL SHUTDOWN VALVE ON TANK.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Lifesaving
Issued 16 December 1998
Resolved
PROVIDE LEGIBLE SWL CHART FOR STBD CRANE.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Fire Fighting
Issued 16 December 1998
Resolved
REPLACE GASKET FOR FIRE HOSE NOZZLE AT STATION #4
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Electrical
Issued 16 December 1998
Resolved
REPLACE FLEXIBLE COUPLINGS ON ALL GENERATOR SALT WATER COOLERS.
Condition: Unknown
Due 16 January 1999
Resolved 11 January 1999
Construction/Loadline
Issued 16 December 1998
Resolved
PROVIDE COMPLETED ABS REPORT FOR UWILD, TO INCLUDE SWIM-BY OF MAT.
Condition: Unknown
Due 16 December 1998
Resolved 16 December 1998
Electrical
Issued 16 December 1998
Resolved
INSTALL METAL TIE WRAPS FOR WIRING IN OVERHEAD ON DRILL FLOOR EVERY 30 INCHES.
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Lifesaving
Issued 16 December 1998
Resolved
REPAIR DAMAGED #2 PORT SIDE LIFEBOAT TO THE SATISFACTION OF THE LOCAL OCMI
Condition: Unknown
Due 16 December 1998
Resolved 16 December 1998
Documentation
Issued 16 December 1998
Resolved
PROVIDE COPY OF FCC LICENSE W/ NEW RIG NAME ON CERTIFICATE.
Condition: Unknown
Due 16 December 1998
Resolved 16 December 1998
Construction/Loadline
Issued 16 December 1998
Resolved
REPAIR SAFETY RAILING WHERE WASTED BY STBD & PORT ABANDON RIG STATIONS.
Condition: Unknown
Due 16 January 1999
Resolved 11 January 1999
Lifesaving
Issued 16 December 1998
Resolved
CONDUCT 110% RELEASE GEAR, WEIGHT TEST TO #2 LIFE BOAT, RELEASE GEAR TEST TO #1 LIFE BOAT.
Condition: Unknown
Due 16 December 1998
Resolved 16 December 1998
Construction/Loadline
Issued 16 December 1998
Resolved
REPAIR PORT SIDE WTD INDICATOR LIGHT IN ENGINE ROOM
Condition: Unknown
Due 17 December 1998
Resolved 17 December 1998
Construction/Loadline
Issued 5 November 1998
Resolved
CROP AND RENEW AS ORIGINAL GASKET FLATBAR FOR PAINT LOCKER DOOR.
Condition: Unknown
Due 30 November 1998
Resolved 17 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
RENEW WASTED HATCH COVERS FOR #6 PORT AND #6 STARBOARD TANKS.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
RENEW ROTTED GASKETS FOR #6 PORT AND STARBOARD, #8 PORT, AND #9 CENTERLINE_x001C_TANKS.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
RENEW MISSING STUDS FOR #9 CENTERLINE, #8 PORT HATCH COVERS.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
CONDUCT SWIM BY/PHASE II PORTION OF SEILODD, CONTACT LOCAL OCMI IN ADVANCE OF COMMENCEMENT.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
CROP AND RENEW AS ORIGINAL WASTED KNIFE EDGE TO WATER TIGHT DOOR #1 (CONTROL HOUSE).
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
CROP AND RENEW AS ORIGINAL WASTED KNIFE EDGE ON DOOR #7 (CENTERLINE, AFT OFSUPER STRUCTURE)
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
PROVE PROPER OPERATION OF STICKING WEATHER DECK BALL VENT CLOSURE DEVICES AT DRILL WATER VENT #2-PORT, AND #2 STARBOARD.
Condition: Unknown
Due 30 November 1998
Resolved 17 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
CROP AND RENEW AS ORIGINAL ALL WASTAGE IDENTIFIED ON THE DRILL FLOOR DECK AND BULKHEADS.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
CROP AND RENEW AS ORIGINAL WASTED KNIFE EDGE ON HATCH TO SACK ROOM (PORT AFT OF SUPER STRUCTURE).
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 21 January 1998
Resolved
INSTALL A LOSS-OF-VENTILATION ALARM SYSTEM THAT IS WIRED INDEPENDENTLY OF THE MUD PIT ROOM AND/OR MUD PUMP ROOM/SACK ROOM VENTILATION MOTOR CONTROLLERS. SYSTEM MUST SENSE VENTILATION FLOW OR ACTUAL LOSS OF RELATIVEPRESSURE DIFFERENTIAL BETWEEN MUD PIT RM & ADJACENT MUD PUMP RM & SACK RM.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Fire Fighting
Issued 21 March 1997
Resolved
PROVE PROPER OPERATION OF 02/EXPLOSIVE METER
Condition: Unknown
Due 21 April 1997
Resolved 11 April 1997
Lifesaving
Issued 4 February 1996
Resolved
PRIOR TO LEAVING VR189, PERFORM FIRE AND BOAT DRILLS.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Electrical
Issued 4 February 1996
Resolved
PERFORM IN PRESENCE OF A MARINE INSPECTOR FULL FUNCTIONAL TESTS ON ALL EMD'S.
Condition: Unknown
Due 4 April 1996
Resolved 29 March 1996
Lifesaving
Issued 4 February 1996
Resolved
PRIOR TO LEAVING VR189, PROVE PROPER OPERATION OF SPRINKLER SYSTEM IN BOTH LIFE CAPSULES.
Condition: Unknown
Due 4 April 1996
Resolved 29 March 1996
Fire Fighting
Issued 4 February 1996
Resolved
PERFORM FUNCTIONAL TEST OF FIRE STATIONS #12 AND #13 ON DRILL FLOOR.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Lifesaving
Issued 4 February 1996
Resolved
PERFORM WEIGHT TESTS OF BOTH LIFE CAPSULES.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Construction/Loadline
Issued 4 February 1996
Resolved
PERFORM FUNCTIONAL TEST OF BILGE PUMPING SYSTEM.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Electrical
Issued 4 February 1996
Resolved
REPAIR BUNK LIGHTS IN QUARTERS ROOMS 1-3 AND 1-7.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Navigation
Issued 4 February 1996
Resolved
PERFORM FUNCTIONAL TEST OF FOGHORN.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Construction/Loadline
Issued 4 February 1996
Resolved
PROPERLY ADJUST WATERTIGHT DOORS #5 AND #10.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Lifesaving
Issued 4 February 1996
Resolved
REPLACE EXPENDABLE BOTTLE TO DRILL FLOOR EYE WASH STATION.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Lifesaving
Issued 4 February 1996
Resolved
REPAIR WINCH CONTROLLER TO #2 LIFE CAPSULE.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Electrical
Issued 4 February 1996
Resolved
REPAIR/REPLACE WASTED BOX TO PORT VENTILATION EMERGENCY STOP.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Engineering
Issued 4 February 1996
Resolved
INSTALL FUEL SHUT-OFF VALVE IN LINE TO STANDBY GENERATOR.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Electrical
Issued 4 February 1996
Resolved
RELABEL CIRCUIT BREAKER PANEL LEGEND AT STANDBY GENERATOR ON LEFT SIDE OF BULKHEAD.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Deck/Cargo
Issued 4 February 1996
Resolved
MAKE READY FOR INTERNAL EXAM 2 CEMENT BULK TANKS AND 1 GEL BULK TANK.
Condition: Unknown
Due 4 March 1996
Resolved 29 March 1996
Deck/Cargo
Issued 4 February 1996
Resolved
MAKE READY FOR INTERNAL EXAM AIR RECEIVER ON DRILL FLOOR AND STARTING AIR RECEIVER.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Electrical
Issued 4 February 1996
Resolved
PRIOR TO LEAVING VR189, PERFORM FUNCTIONAL TEST OF TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 4 April 1996
Resolved 29 March 1996
Construction/Loadline
Issued 4 February 1996
Resolved
WELD UNDERSIDE OF DECK INSERT ABOVE #3 EMD GENERATOR.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Lifesaving
Issued 4 February 1996
Resolved
INCREASE WATER PRESSURE TO EYE WASH STATION IN SACK ROOM.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Deck/Cargo
Issued 4 February 1996
Resolved
PROVE PROPER OPERATION OF ALL RELIEF VALVES AND PROVIDE MANUFACTURER'S CERTIFICATES FOR THE SAME.
Condition: Unknown
Due 4 March 1996
Resolved 15 March 1996
Construction/Loadline
Issued 22 March 1995
Resolved
CONDUCT NECESSARY REPAIRS OR MAINTAINANCE TO HELIDECK SUBSTRUCTURE.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Fire Fighting
Issued 22 March 1995
Resolved
SUBMIT REVISED FIRE AND SAFETY PLAN TO [name withheld] FOR APPROVAL INDICATING ADDITIONAL FIRE STATION (#14) FOR LOWER QUARTERS.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 22 March 1995
Resolved
PERFORM TESTS TO MAIN GEN PRIME MOVERS.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Electrical
Issued 22 March 1995
Resolved
TEST EMER. GEN AUTO BUS TRANSFER AND E-LIGHTING.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Construction/Loadline
Issued 14 January 1994
Resolved
RENEW WASTED PLATING AND ANGLES ABOVE SHALE SHAKER AREA.
Condition: Unknown
Due 19 January 1994
Resolved 27 January 1994
Fire Fighting
Issued 14 January 1994
Resolved
REPAIR OR REPLACE FIRE STATION #2 CUT OUT VALVE.
Condition: Unknown
Due 14 January 1994
Resolved 27 January 1994
Accommodation/Occupational Safety
Issued 14 January 1994
Resolved
CONDUCT INTERNAL EXAM OF AIR RECIEVER ON DRILL FLOOR.
Condition: Unknown
Due 14 January 1994
Resolved 14 January 1994
Accommodation/Occupational Safety
Issued 14 January 1994
Resolved
REPLACE WASTED DOOR FRAMES INWAY OF DOORS LEADING INTO MUD PIT ROOM
Condition: Unknown
Due 14 January 1994
Resolved 14 January 1994
Construction/Loadline
Issued 22 November 1993
Resolved
CONDUCT UNDERWATER SWIMBY OF BOTTOM OF MAT PRIOR TO UNITS NEXT RIG MOVE ANDAFTER UNDERWATER PORTION OF INSPECTION.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Construction/Loadline
Issued 22 November 1993
Resolved
MAKE AVAILABLE FOR INSPECTION VESSEL MAT AND MAT TO COLUMN CONNECTIONS IAW UNDERWATER SURVEY PROPOSAL SUBMITTED 08NOV93.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Engineering
Issued 26 March 1993
Resolved
REPLACE PLASTIC SIGHT GLASS ON EMERGENCY GENERATOR DAY TANK WITH APPROVED GLASS TYPE
Condition: Unknown
Due 5 April 1993
Resolved 9 April 1993
Engineering
Issued 26 March 1993
Resolved
PROVIDE OR MAKE PORT FUELING STATION NOZZEL, DDEAD MAN TYPE.
Condition: Unknown
Due 5 April 1993
Resolved 9 April 1993
Electrical
Issued 26 March 1993
Resolved
REPAIR EMERGENCY GENERATOR ALARM PANEL AND PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN OF PRIME MOVER
Condition: Unknown
Due 26 March 1993
Resolved 26 March 1993
Deck/Cargo
Issued 26 March 1993
Resolved
PROVIDE FIVE YEAR PROOF-LOAD TEST ON STARBOARD CRANE.
Condition: Unknown
Due 29 March 1993
Resolved 9 April 1993
Deck/Cargo
Issued 26 March 1993
Resolved
PROVIDE PROOF OF ANNUAL WEIGHT TEST FOR BOTH CRANES.
Condition: Unknown
Due 29 March 1993
Resolved 9 April 1993
Navigation
Issued 16 January 1992
Resolved
REPAIR OR RENEW STARBOARD AFT OBSTRUCTION LIGHT.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Lifesaving
Issued 16 January 1992
Resolved
CONDUCT OPERATIONAL TESTS OF BOTH LIFEBOATS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Deck/Cargo
Issued 16 January 1992
Resolved
RENEW STARBOARD CRANE FUELING HOSE.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Documentation
Issued 16 January 1992
Resolved
PROVIDE MSO PORT ARTHUR, TEXAS WITH CERTIFICATE OF ANNUAL CRANE EXAMINATIONAND CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Deck/Cargo
Issued 16 January 1992
Resolved
HYDROSTATICALLY TEST TO 125% MAWP THE AIR RECIEVER ON THE DRILL FLOOR IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Accommodation/Occupational Safety
Issued 16 January 1992
Resolved
REPAIR THEN PROVE PROPER OPERATION OF GENERAL ALARM BELL/BEACON IN THE MUD PIT AND PUMP ROOMS.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Documentation
Issued 16 January 1992
Resolved
PROVIDE MSO PORT ARTHUR, TEXAS WITH COPY OF CURRENT LOADLINE CERTIFICATE.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Electrical
Issued 16 January 1992
Resolved
OPERATE AND TEST NO.2 MAIN GENERATOR AND PRIME MOVER.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Engineering
Issued 16 January 1992
Resolved
INSTALL A BATTERY BOX FOR THE COLD START ENGINE BATTERY.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Lifesaving
Issued 16 January 1992
Resolved
MARK RIG SHUTDOWN ON DRILL FLOOR TO PROPERLY INDICATE OUTCOME.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Construction/Loadline
Issued 16 January 1992
Resolved
PROPERLY ADJUST AND MARK WATERTIGHT DOOR NUMBER 14.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Electrical
Issued 16 January 1992
Resolved
RECONNECT OR REMOVE DEADEND WIRING IN THE WASTEWATER PUMPROOM.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Accommodation/Occupational Safety
Issued 16 January 1992
Resolved
PROPERLY COVER AND MAKE TIGHT ACCESS PLATES TO WASTEWATER TANKS IN THE WASTEWATER PUMPROOM.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Lifesaving
Issued 16 January 1992
Resolved
CONDUCT FIRE AND BOAT DRILL IN THE PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Construction/Loadline
Issued 2 September 1991
Resolved
MAKE PERMANENT REPAIRS TO PIN HOLE DAMAGE AT 180 FOOT AND 189 FOOT LEVELS, PORT LEG.
Condition: Unknown
Due 2 September 1991
Resolved 2 September 1991
Deck/Cargo
Issued 2 September 1991
Resolved
OPEN AND PRESENT FOR INSPECTION ALL EMPTY TANKS, VOIDS AND MUD PITS.
Condition: Unknown
Due 2 September 1991
Resolved 2 September 1991
Deck/Cargo
Issued 2 September 1991
Resolved
OPEN FOR INSPECTION ALL FIVE MUD PIT DUMP VALVES.
Condition: Unknown
Due 2 September 1991
Resolved 2 September 1991
Deck/Cargo
Issued 6 February 1991
Resolved
PROVIDE PROOF OF HYDROSTATIC TEST OF FUEL TRANSFER HOSE.
Condition: Unknown
Due 6 February 1991
Resolved 6 February 1991
Unknown
Issued 23 January 1990
Resolved
REPLACE THE MOTOR CONTROLLER RESET SWITCH AT LIFEBOAT #1 FOR THE WINCH
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Unknown
Issued 23 January 1990
Resolved
CHANGE OUT LIFEBOAT FALLS AND PROVIDE CABLE CERTIFICATION.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Unknown
Issued 23 January 1990
Resolved
REPLACE COVERS ON OBSTRUCTION LIGHTS ON PORT AND STARBOARD.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Unknown
Issued 23 January 1990
Resolved
REPLACE RINGBUOY MOUNTING BRACKET FOR SMOKE ON THE STARBOARD AMIDSHIPS.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Unknown
Issued 23 January 1990
Resolved
PROVIDE NUTS AND BOLTS FOR DECK COVERS IN VICINITY OF RUNNING LIGHTS.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Unknown
Issued 23 January 1990
Resolved
TEST IN THE PRESENCE OF A MARINE INSPECTOR REVERSE POWER RELAYS FOR #1 AND #3 GENERATORS.
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Construction/Loadline
Issued 30 November 1988
Resolved
MAKE AVAILABLE FOR COAST GUARD INSPECTION THE TOP, SIDES AND BOTTOM OF THE MAT.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Construction/Loadline
Issued 30 November 1988
Resolved
MAKE AVAILABLE FOR COAST GUARD INSPECTION ALL SEA AND MUD PIT DUMP VALVES.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Navigation
Issued 6 February 1988
Resolved
MAKE AVAILABLE THE THREE RIG IR RECEIVER RELIEF VALVES FOR TESTING.
Condition: Unknown
Due 6 February 1988
Resolved 6 February 1988
Navigation
Issued 6 February 1988
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION ALL THREE RIG AIR RECEIVERS.
Condition: Unknown
Due 6 February 1988
Resolved 6 February 1988
Electrical
Issued 6 February 1988
Resolved
MAKE THE FOLLOWING GENERAL ALARMS OPERABLE: ALARM BELL IN SACKROOM, ALARM BELL ON DRILL FLOOR AND THE GENERAL ALARM LIGHT IN THE GENERATOR ROOM.
Condition: Unknown
Due 6 February 1988
Resolved 6 February 1988
Construction/Loadline
Issued 31 March 1987
Resolved
ADJUST QUICK ACTING WATER TIGHT DOOR SO IT OPERATES FREELY, LOCATED ON HOUSE, AFT BULKHEAD, PORT SIDE.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Electrical
Issued 31 March 1987
Resolved
MAKE OPERATIONAL THE AUTOMATIC STARTING SYSTEM ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Fire Fighting
Issued 31 March 1987
Resolved
PROVIDE ONE ADDITIONAL OXYGEN/COMBUSTIBLE GAS METER, FM OR UL APPROVED, ONBOARD RIG. THE ONE IN THE CONTROL ROOM HAS AN IN OPERATIVE LEL METER.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Fire Fighting
Issued 31 March 1987
Resolved
SELF CONTAINED BREATHING APPARATUS (SCUBA) AIR BOTTLE TO BE HYDRO TESTED AND REFILLED, FOR SCUBA LOCATED IN CONTROL ROOM.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Fire Fighting
Issued 31 March 1987
Resolved
COMPLETE ALL DISCREPENCY ITEMS MOTED ON SAFETY CONCEPTS FIVE FIGHTING SERVICE REPORT DATED 87JAN26.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Lifesaving
Issued 31 March 1987
Resolved
TEST LINE THROWING APPLIANCE AND LOG THE SAME, ALSO PROVIDE AT LEAST 4 ROCKETS FOR GUN. ROCKERS ONBOARD ARE EXPIRED.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Documentation
Issued 31 March 1987
Resolved
PROVIDE ONBOARD A VALID USCG CERTIFICATE OF FINANCIAL RESPON.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Lifesaving
Issued 31 March 1987
Resolved
BOTH LIFEBOAT CAPSULES TO BE OPERATED IN THE WATER.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Lifesaving
Issued 31 March 1987
Resolved
CHANGE FUEL IN BOTH LIFEBOAT CAPSULES.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Lifesaving
Issued 31 March 1987
Resolved
PROVIDE A COMPLETE TOOL KIT IN LIFEBOAT CAPSULE NO. 1, STBD SIDE.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Unknown
Issued 7 October 1986
Resolved
MAKE ALL SEA VALVES LOCATION IN THE NUMBER (7) SEVEN VOID SPACES AVAILABLE FOR INSPECTION PRIOR TO BEGINING DRILLING OPERATIONS AND PRIOR TO 14NOV86.
Condition: Unknown
Due 7 October 1986
Resolved 7 October 1986
Electrical
Issued 6 February 1986
Resolved
REPAIR IN KIND THE EXHAUST LEAK ON THE #3 GENERATOR EXHAUST STACK.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Electrical
Issued 6 February 1986
Resolved
SECURE THE BATTERY BOXES FOR THE OBSTRUCTION LIGHTS AND THE FOG HORN.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Construction/Loadline
Issued 6 February 1986
Resolved
REPAIR THE POSITION INDICATING LIGHT FOR WATERTIGHT DOOR #14.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Navigation
Issued 6 February 1986
Resolved
REPLACE THE DAMAGED PORT AFT OBSTRUCTION LIGHT.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Accommodation/Occupational Safety
Issued 6 February 1986
Resolved
MAKE AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTOR ALL BARITE AND CEMENT TANKS AND THEIR ASSOCIATED RELIEF VALVES.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Accommodation/Occupational Safety
Issued 6 February 1986
Resolved
MAKE AVAILABLE TO A USCG MARINE INSPECTOR FOR INTERNAL INSPECTION ALL AIR RECEIVERS AND PRESSURE TEST THE RELIEF VALVES ON THE AIR RECEIVERS, THE POTABLE AND SANITARY WATER TANK AND THE TWO BOP UNIT.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Electrical
Issued 6 February 1986
Resolved
REPAIR AND TEST IN THE PRESENCE OF A USCG MARINE INSPECTOR THE REVERSE POWER RELAY ON THE #3 GENERATOR WHEN OPERATED IN PARALLEL WITH THE #2 GENERATOR.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Lifesaving
Issued 6 February 1986
Resolved
REMOVE ALL WATER WITH EXPIRING SERVICE DATES FROM THE #1 AND #2 LIFEBOATS AND REPLACE WITH 162 QUARTS OF SERVICEABLE WATER IN EACH LIFEBOAT.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Lifesaving
Issued 12 February 1985
Resolved
PROVIDE A SERVICEABLE SMOKE CANISTER FOR THE FORWARD STARBOARD RING BUOY.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Construction/Loadline
Issued 12 February 1985
Resolved
PACK THE STUFFING TUBE BETWEEN THE MUD PIT ROOM AND THE P-TANK ROOM.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Fire Fighting
Issued 12 February 1985
Resolved
REPAIR THE APPLICATOR AT FIRE STATION #7 IN THE MUD PIT ROOM.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Construction/Loadline
Issued 12 February 1985
Resolved
REPLACE THE GASKET ON THE HATCH ABOVE THE MUD PIT ROOM.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Electrical
Issued 12 February 1985
Resolved
INSTALL AN ELECTRICAL COVER PLATE ON THE AIR CONDITIONING UNITS IN THE LIVING QUARTERS.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Unknown
Issued 12 February 1985
Resolved
REPLACE THE RELIEF VALVE ON THE AIR RECEIVER IN THE WATER MAKER ROOM.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Navigation
Issued 12 February 1985
Resolved
REPAIR OR REPLACE WIND INDICATOR.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Lifesaving
Issued 12 February 1985
Resolved
PROVIDE SERVICEABLE ORANGE SMOKE DISTRESS SIGNALS, RED DISTRESS FLARES, ANDRED PARACHUTE FLARES FOR LIFE CAPSULES #1 AND #2.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Lifesaving
Issued 12 February 1985
Resolved
RENEW LIFE CAPSULE MARKINGS AS PER 46 CFR 108.645 FOR LIFE CAPSULES #1 AND #2.
Condition: Unknown
Due 12 February 1985
Resolved 12 February 1985
Documentation
Issued 14 February 1984
Resolved
SUBMIT FOR APPROVAL AN UP-DATED FIRE CONTROL PLAN TO SHOW PRESENT CONDITIONOF MODU.
Condition: Unknown
Due 14 February 1984
Resolved 14 February 1984
Electrical
Issued 14 February 1984
Resolved
INSTALL 1 GEN ALARM BELL ON THE WX DECK IN THE VICINITY OF THE B.J. UNIT / CONTROL HOUSE DUE TO "DEAD AREA"
Condition: Unknown
Due 14 February 1984
Resolved 14 February 1984