MAURY USCG vessel records Sign in
← All vessels

GULF MARINER

GULF MARINER is a 1981 offshore supply vessel. The Coast Guard has recorded 49 inspections since 1981, most recently in July 2017, along with 54 deficiencies.

Records from 1981 to 2017. Most recent: inspection, 7 July 2017.

Built
1981
Last inspected
7 July 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8119986 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD7766
Flag
MEXICO
367012240, 367191020 (licence lapsed)
Maury page id
psix-53405

Inspections, by type

…with no type recorded11
Years with a record 25 calendar years (1981–2017)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it564 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD7766MMSI 367191020 · expired · voluntarily equipped · granted 31 May 2007, cancelled 5 August 2017
WDC3668MMSI 367012240 · expired · voluntarily equipped · granted 19 January 2005, cancelled 21 March 2015
WCY8752MMSI not assigned · expired · compulsorily equipped · granted 8 February 1999, cancelled 11 April 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DEA PATROL Offshore Supply Vessel · MISLE 54391 · 17 July 2001 · activity 28896NOBLE CARL NORBERG Mobile Offshore Drilling Unit · MISLE 472820 · 2 November 1999 · activity 17777

Inspection history · 49

7 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6201357
8 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3284908
19 March 2008 Examination of Repairs · Cargo Tank Internal · Internal Structural Exam · Deficiency Check · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3194871
28 October 2007 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3088356
3 July 2007 Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2982304
7 July 2006 Re-Inspection · Deficiency Check · MTSA Verification · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2704370
24 August 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2473435
18 August 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2467956
18 July 2005 Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2430631
15 June 2005 MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2391832
10 May 2004 Examination of Repairs · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2064250
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998563
10 April 2003 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1771419
22 April 2002 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1607398
9 January 2002 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1476833
17 July 2001 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 28896
17 July 2001 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1068827
6 April 2000 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1413702
4 November 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 799234
2 November 1999 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 17777
2 November 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 798624
14 May 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451397
16 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 224247
21 April 1998 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465368
3 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116905
31 December 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1439836
11 October 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753826
9 October 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 202957
3 November 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422586
5 January 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422462
9 December 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405466
21 January 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 831634
24 December 1992 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403569
21 January 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943666
12 December 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267963
10 December 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229030
12 October 1990 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911707
15 February 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236279
16 January 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914985
13 December 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231854
18 January 1989 MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899106
18 January 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205098
11 December 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1317453
22 January 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319767
14 November 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996019
17 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977626
13 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977478
4 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971662
28 October 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969786

Deficiency record · 54

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 19 March 2008 Resolved
Renew cargo pump remote shutdown near emergency exit.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 9 June 2008
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 19 March 2008 Resolved
Repair 2 amp ground indicated on main panel.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 9 June 2008
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 19 March 2008 Resolved
Provide fourth line throwing cannister/projectile for line throwing gun.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 9 June 2008
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 19 March 2008 Resolved
Renew all site glasses on oil and fuel tanks, all need to be glass not plastic.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 9 June 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 19 March 2008 Resolved
Remount emergency light in engine on port side, light currently shines on an exhaust pipe and not on exit.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 9 June 2008
Electrical › Electric Supply System (service) › Battery Charger
Issued 19 March 2008 Resolved
Install batter charger amp meter on bow thruster battery charger.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 9 June 2008
Engineering › Steering Gear System › Motor
Issued 28 October 2007 Resolved
Vessel to repair, test and provide service report for steering system prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2007
Resolved 30 October 2007
Resolution: Service report recieved documenting repair and testing of system.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 3 July 2007 Resolved
Fuel oil transfer pump leaking from failure of the mechanical seal
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2007
Resolved 5 July 2007
Resolution: Received affidavit and receipt of repairs
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 3 July 2007 Resolved
Replace leaking mechanical seal of sewage discharge pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2007
Resolved 5 July 2007
Resolution: Received affidavit and receipt of repairs
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 3 July 2007 Resolved
Install duoble nuts on/tighten shaft packings
Condition: Improper/Lack of Maintenance
Due 3 August 2007
Resolved 9 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2007 Resolved
Remove dead-end wires
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 9 June 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 3 July 2007 Resolved
Fire dampers could not seal; fasters nedd adjustment/service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 5 July 2007
Resolution: Cleared due to vessel master affidavit & invoice of repairs
Operations/Management › Drills/Instruction › Fire
Issued 3 July 2007 Resolved
Demonstrate proper operation of fire drills; improve crew knowledge of WQSB responsibilites/fire response duties.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2007
Resolved 5 July 2007
Resolution: Received affidavit and receipt of repairs
Engineering › Generator (propulsion-electric) › Ground Detection Equipment Circuitry
Issued 3 July 2007 Resolved
Prove proper operation of ground test equipment.
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 9 June 2008
Engineering › Steering Gear System › Rudder
Issued 3 July 2007 Resolved
Install double nuts on rudder post packings
Action required: 705 - Other - as specified
Due 3 August 2007
Resolved 5 July 2007
Resolution: Cleared due to vessel master affidavit & invoice of repairs
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 18 July 2005 Resolved
Vsl operating w/ overdue survey for loadline
Due 11 September 2005
Resolved 4 August 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 July 2005 Resolved
Vsl operating w/ expired COD
Due 11 September 2005
Resolved 4 August 2005
Deck/Cargo › Cargo Stowage › General
Issued 18 July 2005 Resolved
The master failed to comply with the vessels stability letter. The max VCG on the stability was noted at 3 feet. The two different types of tank portable tank racks on deck had a VCG of 4 feet and four feet inches. The vessel must offload the cargo prior to sailing.
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 4 August 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 May 2004 Resolved
Starboard shaft tach inoperable.
Condition: Unknown
Due 6 June 2004
Resolved 7 May 2004
Resolution: Tach repaired.
Stability › Unintentional Flooding › General
Issued 6 May 2004 Resolved
Make repairs to soft patch on port fuel vent at next drydock.
Condition: Improper/Lack of Maintenance
Due 6 December 2005
Resolved 4 August 2005
Construction/Loadline › Structures
Issued 6 May 2004 Resolved
Bulkhead in #6 STBD ballast tank wasted. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Due 10 May 2004
Resolved 7 May 2004
Resolution: Repairs done and tested.
Engineering › Compressed Air System (start air)
Issued 10 April 2003 Resolved
RENEW POP OFF ON PORT SIDE PRESSURE VESSEL. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 April 2003 Resolved
REPAIR GROUND ON MAIN DISTRIBUTION PANEL.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 10 April 2003 Resolved
PROVIDE ANNUAL SERVICING OF ALL CO2 FIRE ENTINGUISHERS.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 April 2003 Resolved
PROVIDE FIRST AID KIT.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 April 2003 Resolved
PROVIDE OPERATIONAL ANGLE INDICATOR AT ENGINEROOM OPERATING STATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2003
Resolved 11 April 2003
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 10 April 2003 Resolved
PROVIDE 4 LIGHTS FOR REQUIRED LIFEJACKETS.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 10 April 2003 Resolved
PROVIDE COVER FOR BARE LIGHT BULB ON GALLEY HOOD RANGE. LEGACY COMPONENT DESC: GALLEY HOOD RANGE LIGHT
Due 10 May 2003
Resolved 11 April 2003
Lifesaving › Hand Flares › Storage
Issued 10 April 2003 Resolved
PAINT FLARE BOX WITH BRIGHT COLOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Lifesaving › Embarkation Appliances/Stations
Issued 10 April 2003 Resolved
PROVIDE RESCUE PLATFORM AND STOKES LITTER TO SATISFY THE 8TH DISTRICT RESCUE BOAT POLICY. LEGACY COMPONENT DESC: RESCUE PLATFORM
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Communications › Visual Communication › Signalling Lamp
Issued 10 April 2003 Resolved
PROVIDE BATTERY BACK UP FOR BLUE LIGHT IN ENGINEROOM UNDER FINAL EMERGENCY POWER SOURCE.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 April 2003 Resolved
REPAIR OR REMOVE OILY WATER SEPERATOR IN ENGIREROOM.
Action required: 705 - Other - as specified
Due 10 May 2003
Resolved 11 April 2003
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 10 April 2003 Resolved
PROVIDE LOCAL NOTICE TO MARINERS.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 11 April 2003
Construction/Loadline › Hull
Issued 22 April 2002 Resolved
Issued Permit to Proceed to LaRose , LA for temp repairs due to a 1/2" hole in the bottom discovered during a potential seller's drydock. Temp repair made (doubler) and vsl departed w/out COI. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 10 April 2003
Construction/Loadline
Issued 2 November 1999 Resolved
Crop and renew damaged areas (two sections) on the port, mid-section area, in way of the deck turn. Repairs to be tested for & inspected by Coast Guard Inspector. Vessel is not go offshore until repairs have been completed.
Condition: Unknown
Due 24 November 1999
Resolved 24 November 1999
Construction/Loadline
Issued 31 December 1996 Resolved
Crop and renew wasted transverse stiffners in way of port and starboard rudder post penetraions.
Condition: Unknown
Due 31 December 1996
Resolved 31 December 1996
Engineering
Issued 9 December 1993 Resolved
Provide documentation proving satisfactory operation of level indicator alarm for port fuel oil daytank.
Condition: Unknown
Due 9 January 1994
Resolved 4 January 1994
Engineering
Issued 9 December 1993 Resolved
PROVIDE DOCUMENTATION PROVING SATISFACTORY OPERATION OF OVERSPEED TRIPS ON STARBOARD MDE AND STARBOARD GENERATOR.
Condition: Unknown
Due 14 December 1993
Resolved 14 December 1993
Fire Fighting
Issued 9 December 1993 Resolved
Install fixed fire extinguishing system in paint locker and provide certificate of compliance from fire servicing company.
Condition: Unknown
Due 4 January 1994
Resolved 4 January 1994
Engineering
Issued 24 December 1992 Resolved
PROVE OPERATION OF MAIN ENGINE OVERSPEED TRIPS TO A CG INSPECTOR.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Deck/Cargo
Issued 24 December 1992 Resolved
HYDROSTATICALLY TEST ALL FUEL AND CARGO TRANSFER HOSESIN ACCORDANCE WITH _x001C_ 33 CFR 154.500.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Documentation
Issued 24 December 1992 Resolved
PROVIDE A WASTE MANAGEMENT PLAN IN ACCORDANCE WITH 33 CFR 151.57.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Documentation
Issued 24 December 1992 Resolved
PROVIDE FUEL OIL AND CARGO OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.750.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Deck/Cargo
Issued 24 December 1992 Resolved
INSTALL FLAME SCREENS ON ALL CARGO VENTS IN ACCORDANCE WITH 46 CFR SUBCHAPTER D.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Documentation
Issued 12 December 1991 Resolved
SUBMIT THREE (3) COPIES OF FIRE SAFETY PLAN TO [name withheld], LA. FOR REVIEW AND APPROVAL. 46 CFR 91-55-5(d).
Condition: Unknown
Due 12 December 1991
Resolved 12 December 1991
Engineering
Issued 12 October 1990 Resolved
MAKE REPAIRS TO PORT AND STARBOARD SHAFT TACHOMETERS.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Deck/Cargo
Issued 13 December 1989 Resolved
PROVE PROPER OPERATION OF RELIEF VALVES FOR DRY BULK TANKS TO COMPLY WITH 46 CFR 54.15-10(A).
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Unknown
Issued 13 December 1989 Resolved
REPAIR REMOTE SHUT DOWNS ON BOTH PORT AND STBD BLOWER AND PROVE OPERATION TO COMPLY WITH 46 CFR 92.15-10(B).
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Engineering
Issued 13 December 1989 Resolved
REPAIR REMOTE SHUT DOWNS FOR BOTH PORT AND STBD FUEL SUPPLY VALVES TO COMPLY WITH 46 CFR 58.01-25.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Unknown
Issued 13 December 1989 Resolved
REPAIR AND PROVE OPERATION OF VESSELS DEPTH SOUNDER TO COMPLY WITH GOOD MARINE PRACTICE.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Unknown
Issued 13 December 1989 Resolved
PROVE OPERATION OF PORT AND STBD S/S GENERATOR OVERSPEEDS TO COMPLY WITH 46 CFR 111.12-11(B).
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Unknown
Issued 13 December 1989 Resolved
REPLACE RELIEF VALVES ON BOTH S/S AIR RECIEVERS WITH RELIEFS OF PROPER SETTING AND PROVE OPERATION TO COMPLY WITH 46 CFR 54.15-10(A).
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Navigation
Issued 22 January 1987 Resolved
PROVIDE ON BOARD A CURRENT COPY OF THE LIGHT LIST AND SUBCHAPTER "I" OF CODE OF FEDERAL REGULATIONS.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Fire Fighting
Issued 22 January 1987 Resolved
PROVIDE ON BOARD AN APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.