Records from 1981 to 2024. Most recent: inspection, 30 January 2024.
Inspection history · 48
30 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7862114
5 June 2023
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7851320
25 May 2023
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7696443
20 March 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7653671
30 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5843520
4 January 2012
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4217543
15 February 2011
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3945927
8 November 2010
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3910999
2 March 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3415318
6 December 2007
Examination of Repairs · Internal Structural Exam · Drydock Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3157382
27 September 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3078625
4 January 2007
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2850627
9 January 2006
Re-Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2563280
12 January 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2273359
4 March 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2018013
27 August 2003
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1889006
20 March 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1759989
8 January 2003
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727411
30 October 2002
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1698604
14 December 2001
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1475663
18 January 2001
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1465006
15 February 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817409
7 February 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1048147
11 January 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458705
4 December 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808266
10 November 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470189
10 November 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402546
20 December 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357884
1 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 642243
20 February 1996
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883968
19 February 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 15473
8 November 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441011
13 January 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355054
28 December 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373976
14 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362896
14 December 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389601
13 December 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949133
19 December 1990
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244744
13 December 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912278
21 February 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1201584
23 December 1987
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1315415
19 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002626
19 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983922
19 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974849
1 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970184
23 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273090
23 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275115
21 December 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968102
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 May 2023
Resolved
46 CFR 180.130 (c)
A mechanical, manually operated device to assist in launching a survival craft must be provided if: The survival craft weights more than 90.7 kilograms (200 pounds); and The survival craft requires lifting more than 300 vertical millimeters (one vertical foot) to be launched. The 25-Person SOLAS A life raft must be provided a mechanical, manually operated device to assist in launching it or replace the fixed lower rail courses with removable chain rail courses to the satisfaction of the attending Marine Inspector (MI).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 5 June 2023
Resolution: Replaced solid pipe courses with chain courses to allow the liferaft to easily be pushed over the side.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 May 2023
Resolved
46 CFR 58.01-20
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. The guards over each of the main diesel propulsion engines leave the center rotating shafts exposed, which need to be modified to adequately shield this area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 6 June 2023
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 May 2023
Resolved
33 CFR 83.22(b)(i) (Rule 22)
In a vessel of 12 meters or more in length but less than 50 meters in length: (i) A masthead light, 5 miles; except that where the length of the vessel is less than 20 meters, 3 miles. The vessel's masthead light was not working.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 May 2023
Resolved
46 CFR 180.35-5 (Old T)
Except as otherwise provided in this section, all vessels shall carry pyrotechnic distress signals as follows: 6 hand red flare distress signals and 6 hand orange smoke distress signal; or, 12 hand combination flare and smoke distress signals. Vessel was missing 3 hand red flare distress signals.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 May 2023
Resolved
46 CFR 170.255(b)
Class I doors are permitted within passenger, crew, and working spaces wherever located, if- In the judgment of the OCMI, the door is in a location where it will be closed at all times except- when actually in use. The Class I watertight door below deck in frame 30 was tied open while underway conducting a man overboard drill and shall be closed as per the COI and the Stability Letter.
Action required: 10 - Deficiency Rectified
Resolved 31 May 2023
Communications › Radio Communications › Emergency Source of Power
Issued 4 January 2012
Resolved
SSB does not transmit. Properly operate SSB on emergency power. Limited route to 100nm.
Due 4 February 2012
Resolved 10 January 2012
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 January 2012
Resolved
Maintain a lifesaving maintenance log to include at minimum monthly EPRIB inspections.
Due 4 January 2013
Resolved 31 January 2014
Resolution: Conducted EPIRB test and ensured it was logged.
Construction/Loadline › Structures › Deck Plating
Issued 8 November 2010
Resolved
Deck Plating has numerous holes through deck and severe wastage in other parts, approximately 3/4 of deck needs to be cropped and renewed to satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Resolution: Deck cropped to good metal and three large inserts added. Dye penetrant test sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 December 2007
Resolved
Noted washer discharge hard piped into vessel's engine room center line bilge which contained oil residue. Although records indicated that bilges are emptied by truck to a reception facility IAW 33 CFR 155.350, attending vessel rep agreed to redirect washer piping to avoid any accidental overboard oil discharge. Attending MI should verify compliance with 155.350 at the next inspection.
Action required: 705 - Other - as specified
Due 3 January 2011
Resolved 4 January 2012
Resolution: [name withheld] inspected engine room to include bilge lines. Washer line is no longer piped into bilge lines.
Electrical › Electric Supply System (service) › Transformer
Issued 2 March 2006
Resolved
Provide a motor controller at compressor motors to the satisfaction of attending marine CG inspector prior to 02APR2006
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 7 March 2006
Resolution: Installed motor controller.
Construction/Loadline › Hull › Hull Plating
Issued 2 March 2006
Resolved
At next COI inspection make permanent repairs to wasted area under engine room ladder at potable water pressure tank at deck level.
Action required: 705 - Other - as specified
Due 14 December 2006
Resolved 4 January 2007
Resolution: COMPLETED
Deck/Cargo › Cargo Stowage › General
Issued 8 January 2003
Resolved
Provide approved plans IWO A-frame to include structural calculations and supporting structure. Plans stamped by a P.E. will be sufficient. LEGACY COMPONENT DESC: A-frame
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 April 2003
Resolved 8 March 2004
Stability › Intact Stability (when using lifting gear) › General
Issued 8 January 2003
Resolved
Provide approved stability calculations / letter to include addition of A-frame IWO aft main deck. LEGACY COMPONENT DESC: Addition of A-frame
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 April 2003
Resolved 8 March 2004
Navigation › Piloting/Steering
Issued 4 January 2002
Resolved
PROVIDE CURRENT TABLES LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2002
Resolved 4 January 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 January 2002
Resolved
REPAIR PORT ENGINE STOP AT OPERATING STATION. LEGACY COMPONENT DESC: Governor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 4 January 2002
Construction/Loadline › Structures › Door
Issued 4 January 2002
Resolved
PROVIDE AND INSTALL WATER TIGHT DOOR AT GALLEY ENTERANCE OR PROVIDE DOCUMENTATION OF DOOR BEING REMOVED IS APPROVED. LEGACY COMPONENT DESC: Door
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 4 January 2002
Construction/Loadline › Structures
Issued 4 January 2002
Resolved
RENEW DOOR GASKETS, ADJUST DOGS, AND STENCIEL ALL WATER TIGHT DOORS THROUGH OUT VESSEL. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 January 2002
Resolved 4 January 2002
Construction/Loadline › Structures
Issued 4 January 2002
Resolved
REPAIR MAIN DECK WATER TIGHT DOOR LEADING INTO CABIN. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2002
Resolved 4 January 2002
Stability › Watertight Integrity
Issued 4 January 2002
Resolved
REPAIR HIGH LEVEL BILGE ALARMS AND INSTALL SEPERATE INDICATOR LIGHTS FOR RUDDER ROOM AND ENGINE ROOM.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 4 January 2002
Electrical › Electric Generation Source (service)
Issued 4 January 2002
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH SHIP SERVICE GENERATOR OVERSPEED TRIPS. LEGACY COMPONENT DESC: Overcurrent Device
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 January 2002
Resolved 4 January 2002
Engineering › Compressed Air System (control) › Valve
Issued 4 January 2002
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH AIR RECEIVER PRESSURE RELIEF VALVES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2002
Resolved 4 January 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 4 January 2002
Resolved
REPAIR WIRES IN PORT ENGINE ROOM FLOOD LIGHT AND FUEL OIL TRANSFER PUMP.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 January 2002
Resolved 4 January 2002
Engineering › Fuel Oil Service System › Valve
Issued 4 January 2002
Resolved
REPAIR PORT FUEL OIL EMERGANCY SHUT OFF REACH ROD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2002
Resolved 4 January 2002
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 4 January 2002
Resolved
REPAIR OR RENEW BOTH SHAFT PACKING GLANDS.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2002
Resolved 4 January 2002
Engineering › Fuel Oil Service System › Suction Strainer
Issued 4 January 2002
Resolved
PROVIDE AND INSTALL METAL PLUGS FOR MAIN ENGINES AND GENERATORS RACOR FILTERS.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 January 2002
Resolved 4 January 2002
Construction/Loadline › Penetrations › Weld
Issued 4 January 2002
Resolved
RESEAL ENGINE ROOM BULKHEAD WIRES AND WELD HOLES.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 January 2002
Resolved 4 January 2002
Engineering › Fuel Oil Service System › Hose
Issued 4 January 2002
Resolved
PROVIDE AND INSTALL CHAFFING GEAR ON BOTH MAIN ENGINE FLEXIBLE HOSES.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 January 2002
Resolved 4 January 2002
Accommodation/Occupational Safety › Potable Water System
Issued 4 January 2002
Resolved
SECURE POTABLE WATER TANK.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 January 2002
Resolved 4 January 2002
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 4 January 2002
Resolved
PROVIDE AND INSTALL FLAME SCREEN FOR HYDROLIC OIL VENT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2002
Resolved 4 January 2002
Electrical
Issued 11 January 2000
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH SSGEN OVERSPEED DEVICES, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Lifesaving
Issued 11 January 2000
Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH CG DISTRICT RESCUE BOAT POLICY LTR DTD 12 NOV 98. TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. VSL IS A DIVE PLATFORM.
Condition: Unknown
Due 11 January 2000
Resolved 11 January 2000
Unknown
Issued 10 November 1998
Resolved
DEMONSTRATE PROPER OPERATION OF BILGE ALARM SYSTEM.
Condition: Unknown
Due 4 December 1998
Resolved 17 December 1998
Electrical
Issued 10 November 1998
Resolved
DEMONSTRATE PROPER OPERATION OF PORT GENERATOR OVERSPEED.
Condition: Unknown
Due 10 December 1998
Resolved 17 December 1998
Construction/Loadline
Issued 10 November 1998
Resolved
INSTALL STRAINERS AND CHECK VALVES ON BILGE SUCTION LINES.
Condition: Unknown
Due 4 December 1998
Resolved 17 December 1998
Deck/Cargo
Issued 20 February 1996
Resolved
REPLACE ANCHOR TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 5 March 1996
Resolved 4 March 1996