Inspection history · 15
4 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8361352
30 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7900954
25 May 2023
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7696737
3 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7703947
7 March 2022
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7490331
4 May 2021
Annual Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7188786
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108314
3 March 2020
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6919453
26 July 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6809695
10 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6681004
1 May 2019
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6673764
16 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6474064
7 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6119363
4 April 2017
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6117153
29 July 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5959138
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 April 2024
Resolved
The discharge ends of vent pipes shall be fitted with removeable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. Vent pipes must be equipped with flame screens. All vents without flame screens.
46 CFR 182.20-40(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Flame screens were added to all vents.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 1 June 2023
Resolved
Reinstall ballast water suction pipe inside ballast tank #1.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2023
Resolved 7 June 2023
Resolution: Ballast water suction pipe replaced and back in service.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 May 2023
Resolved
The master shall conduct fire drills to ensure that all crew members are familiar with their duties. In the course of a CG led fire-drill, the crew didn't communicate the nature of the fire to the vessel CAPT, delayed their response while the fire pump was not activated due to lack of communication, and were not familiar with the use of the fire hose fitted with mechanical foam nozzle and pick-up tube. Crew must effectively perform fire-drill in the presence of vessel company's safety manager or representative to ensure it is done in accordance with company procedures.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2023
Resolved 25 May 2023
Resolution: Fleet Safety Manager gathered crew and went over proper steps to handle a hazmat fire, in accordance with Company procedrues, through adequate communication and proper manning.
process of correct use of foam induction
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 May 2023
Resolved
Each hatch exposed to the weather must be watertight. Hatch cover inside the machinery space, starboard side, didn't close. This cover must be repaired and watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2023
Resolved 25 May 2023
Resolution: Hatch fittings were readjusted and now ensure watertighness.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 May 2023
Resolved
Gages to indicate lubricating oil pressure shall be provided for all propulsion engines and shall be visible to the vessel operator. Oil pressure gage on the bridge for Engine #2 was inoperable and must be fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2023
Resolved 12 June 2023
Resolution: Gage fixed and tested satisfactorily.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 25 May 2023
Resolved
Irrespective of build date a vessel that operate on a Coastwise or Oceans route must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces. Crew accommodation spaces are not equipped with such equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 28 August 2023
Resolution: Interconnected fire detectors in accomodation spaces have been installed and tested satisfactorily.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 May 2023
Resolved
Vessels that operate on a Coastwise or Oceans route must conduct emergency egress training for each member of the crew at least monthly and each time a new crew member joins such vessel. This training must be completed and logged in accordance with CG regulations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 1 August 2023
Resolution: Company Safety Manager trainned crew on egress training and documented in vessel log.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2023
Resolved
Where flexibility is necessary, a flexible hose may be used provided it is fitted with suitable connection fittings. Cracked hoses of MDE #1 must be fixed in kind.
Action required: 705 - Other - as specified
Due 1 June 2023
Resolved 12 June 2023
Resolution: Both hoses were replaced with new ones.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 May 2021
Resolved
E-lights shall be installed to provide light to the main deck. E-light by emergency escape scuttle in E/R half full of water. 46 CFR 183.432
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2021
Resolved 20 May 2021
Resolution: E-light replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 May 2021
Resolved
Sea suction penetration below the water line must have a means to prevent water if fractures. 2 pipe brackets missing on suction line strainers on # 2 and #3 MDE’s which may cause the pipe to fracture below the installed valve. 46 CFR 179.350 (c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2021
Resolved 20 May 2021
Resolution: Brackets welded in place to support pipes.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 May 2021
Resolved
O2 fire main brackets missing in compartment by fire pump. 46 CFR 182.700
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2021
Resolved 20 May 2021
Resolution: Brackets installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 May 2021
Resolved
Emergency escape hatch from E/R, missing gasket. 46 CFR 179.340
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 20 May 2021
Resolved 20 May 2021
Resolution: Gasket installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2020
Resolved
b) Each distribution panel or switchboard must be totally enclosed and of the dead front type. The 220v panel was missing a blank creating a hole exposing wires. Install breaker or blank.
Action required: 10 - Deficiency Rectified
Resolved 3 March 2020
Resolution: Blank installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 March 2020
Resolved
(a) The design of all exhaust systems must ensure minimum risk of injury to personnel. Most of the exhaust lagging was missing or badly worn. Replace all lagging to ensure exhaust pipes covered enough to prevent injury.
Action required: 10 - Deficiency Rectified
Resolved 30 March 2020
Resolution: New lagging was purchased and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2020
Resolved
All cables and wires must; (3) Be protected from the weather. The stern light wire connection was chaffed and when wiggled it made the Nav light work intermittently and also started smoking. Remove and install proper wire.
Action required: 10 - Deficiency Rectified
Resolved 21 March 2020
Resolution: New wire was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2020
Resolved
Electrical wires must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Found one wire above the port generator needing a metal support. Install support in appropriate area.
Action required: 10 - Deficiency Rectified
Resolved 3 March 2020
Resolution: Metal support was installed in appropriate area.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 10 May 2019
Resolved
Crack on the Starboard Bulkhead in the Engine room above the waterline.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2019
Resolved 14 May 2019
Resolution: Vsl cropped and renewed starboard bulkhead in engine room space. Completed NDT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2019
Resolved
Port side machinary room sea chest pipe cracked. VSL will crop and renew pipe.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2019
Resolved 14 May 2019
Resolution: Vsl cropped and renewed pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2018
Resolved
Potable water pipe nipple wasted
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2018
Resolved 16 July 2018
Resolution: Fixed by owner/operator, replaced pipe nipple. Pictures provided by owner/operator.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 July 2018
Resolved
Unauthorized power strip under pilot house main control station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2018
Resolved 16 July 2018
Resolution: Operator installed permanent electrical receptor. Pictures provided by owner/operator.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 29 July 2016
Resolved
AIS lacking on board vessel.
Action required: 705 - Other - as specified
Resolved 29 July 2016
Resolution: Vessel was able to find and implement AIS equipment on board the evening of the inspection.