GOL RUNNER

GOL RUNNER is a 2006 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in April 2026, along with 19 deficiencies and 2 casualty investigations between 2014 and 2019.

Records from 2014 to 2026. Most recent: inspection, 17 April 2026.

Built
2006
Last inspected
17 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 April 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8734310
WDD2762
824324
Flag
UNITED STATES
Maury page id
psix-824324

Documentation record

Registered dimensions (L × B × D)137.1 ft × 27.9 ft × 12.0 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)137.1 ft × 27.9 ft × 12.0 ft
ITC tonnagegross 293 / net 87
BuilderNEUVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFREEPORT, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
293 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
87 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT ROD Passenger (Inspected) · MISLE 50358 · 7 March 2022 · activity 7490331DIAMOND MINE Passenger (Inspected) · MISLE 400643 · 7 March 2022 · activity 7490331JOSEPH G Passenger (Inspected) · MISLE 946853 · 3 September 2019 · activity 6809212

Inspection history · 26

17 April 2026 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 8353305
12 January 2026 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8294777
12 January 2026 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8294853
26 February 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085012
18 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7897426
6 February 2024 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7861283
16 November 2023 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7826128
26 May 2023 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7696930
4 May 2023 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7680885
17 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7669971
3 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7443241
7 March 2022 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7490331
24 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7401445
22 June 2021 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7232466
3 February 2021 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7135055
19 March 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6929543
18 February 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6911195
3 September 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6809212
5 April 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6656379
11 October 2018 Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6559509
2 February 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6348671
29 January 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6345560
3 February 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6082386
9 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5967463
5 February 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5809869
4 February 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5809803

Deficiency record · 19

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 April 2024 Resolved
Emergency lighting must automatically actuate upon failure of the main lighting system. Vessels emergency lighting did not actuate properly.
Action required: 10 - Deficiency Rectified
Resolved 18 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2024 Resolved
All machinery and equipment installed must be suitable for its operation, intended purpose, and to afford adequate protection from causing fire, explosion, and personnel injury. Goose neck vent was not properly affixed to the lube oil tank in engine room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2024 Resolved
Electrical equipment on a vessel must be installed so that it protects passengers crew, other persons, and the vessel from electrical hazards including fire. Vessel had one (01) extension cord and two (02) power strips found on bridge and near entry to engine room.
Action required: 10 - Deficiency Rectified
Resolved 18 April 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2024 Resolved
Each battery must be secured to protect against shifting with the roll and pitch of the vessel. Batteries near port generator not properly secured.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 April 2023 Resolved
Irrespective of build date, a vessel operating on a coastwise or oceans route must meet 46CFR181.405 and 181.450. Vessel did not have interconnected detectors or visual means of alarm in berthing spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2023
Resolved 13 November 2023
Resolution: Received tech report attesting to installation of fire detection in crew spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 April 2023 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard or rail. exhaust fan on PORT side of E/R had broken cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2023
Resolved 18 April 2023
Resolution: Vessel replaced vent cover on PORT side exhaust fan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2023 Resolved
Cable and wiring requirements: (i)(1) the use of twist-on wire nuts is permitted under the following conditions. the connections must be made within an enclosure and the insulated cap of connector must be secured to prevent loosening due to vibration. Vessel had wiring with twist on style connectors, that were not in enclosure nor were secured to prevent loosening.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2023
Resolved 18 April 2023
Resolution: Vessel, properly secured wiring throughout vessel.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 April 2023 Resolved
On a vessel more than 65' in length the public address system must be fixed installation and be audible during normal operating conditions throughout the accommodations spaces and all other spaces normally manned by crew members [name withheld] system was not audible below main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2023
Resolved 18 April 2023
Resolution: Vessel repaired and demonstrated PA in proper working condition throughout the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 May 2022 Resolved
Each entrance to a space storing carbon dioxide or protected by carbon dioxide must be conspicuously marked. Carbon dioxide spaces were not marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 4 May 2022
Resolution: Vessel posted signs with required warning statements to spaces with carbon dioxide storage and protection.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 May 2022 Resolved
Vessel must have a seaworthy hull. Hull is cracked at port generator exhaust.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2022
Resolved 4 May 2022
Resolution: Vessel backgouged and re-welded inside and outside exhaust opening.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2022 Resolved
All emergency exits must be mared with 2 inch letters. Emergency escapes were not marked with 2 inch letter.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 4 May 2022
Resolution: Vessel marked emergency escapes with 2 inch letters.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 May 2022 Resolved
Each life float must have a waterlight. 2 waterlights were cracked and 1 did not function.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
Resolution: Vessel replaced battery in one waterlight and completely replaced both cracked waterlights.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 May 2022 Resolved
other lights exhibited cannot be mistaken for navigation lights. Deck lights were red and easily mistaken.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
Resolution: Vessel removed red deck lights and replaced with white lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 May 2022 Resolved
Pressure indicating gages' upper range must be 1.2 to 2 times the relief pressure. Gage was more than 2 times relief pressure.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
Resolution: Vessel replaced incorrect gages with gages that meet the requirement.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 February 2021 Resolved
Abandon ship drills and training shall be logged or otherwise documented. The drill entry shall include the date of the drill and training and the general description of the drill scenario and training topics. The vessels master could not provide logs or evidence of abandon ship drills or training. Vessel shall ensure abandon ship drills are being logged appropriately to include a drill scenario and training topics. 46 CFR 185.520(f)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 11 February 2021
Resolution: Evidence of drills and training submitted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 3 February 2021 Resolved
The owner or master shall instruct each crewmember, upon first being employed for the first time on a particular vessel and at least once every three months as to the duties the crewmember is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard. Crew training shall be logged or otherwise documented. The training entry shall include the date of the training and the general description of the training topics. The vessels owner or master could not provide logs or evidence of training IAW vessel emergency procedures. Vessel shall conduct training and provide evidence to the attending MI. 46 CFR 185.420(a),(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 11 February 2021
Resolution: Evidence of training received.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 February 2021 Resolved
Each EPIRB must be tested monthly using the integrated test circuit and output indicator, to determine that it's operative; the EPIRB test shall be logged or otherwise documented. Vessel logs did not indicate a test of the EPIRB. Ensure monthly tests are being documented in the vessel log. 46 CFR 185.728(c)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2019 Resolved
Engines #1, 2, and 4 have oil leaks. Repair oil leaks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 8 May 2019
Resolution: Vessel hired mechanic to repair oil leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2019 Resolved
Wiring for shower float switch are not properly spliced. Repair wiring so that it is appropriately insulated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2019
Resolved 8 May 2019
Resolution: Vessel installed junction box

Casualty record · 2

2 October 2014Routine · role: Involved in a Marine Casualty · activity 4997808
3 September 2019Routine · role: Involved in a Marine Casualty · activity 6809212
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MISS CLAIRE (2014–2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.