Records from 1994 to 2025. Most recent: inspection, 13 August 2025.
Inspection history · 43
13 August 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8208971
20 November 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8037840
30 May 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7909891
13 September 2023
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7785028
6 December 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7602792
23 May 2022
Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7457283
7 March 2022
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7490331
8 December 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7364838
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108323
30 November 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7103470
21 May 2020
Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6957025
15 August 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6784729
14 September 2018
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6540251
28 August 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6525321
14 November 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6306793
15 November 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6041246
29 August 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5986585
9 November 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5761148
27 October 2014
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5012659
26 October 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5013155
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200155
13 September 2010
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3844553
22 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3700307
1 December 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3641943
30 September 2008
COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3335902
28 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3137604
21 March 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2891898
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806548
12 January 2006
Hull Examination · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2565191
28 February 2005
Internal Structural Exam · COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2300872
19 February 2004
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2008007
25 April 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1779747
10 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1633710
19 February 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1487290
1 May 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379393
18 February 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391230
11 March 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449144
30 March 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443991
27 February 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400502
8 March 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353877
12 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875474
14 March 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407439
17 March 1994
Initial Construction-Excluding Oversight · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356705
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 August 2025
Resolved
Repairs must be inspected by a marine inspector. Three (03) holes were identified on the overhead within the generator space that were through to the weather deck. One IVO of the port generator, one outboard of both the port and starboard waste dirty oil tanks. Crop/ renew to good metal. NDT and visual inspection to be witnessed by a Marine Inspector for all inserts. Prior to departing Port Fourchon.
46 CFR 176-20-5 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2025
Resolved 15 August 2025
Resolution: Three (03) holes were identified on the overhead within the generator space through to the weather deck were cropped/renewed to good metal via insert. All 03 had NDT via dye penetrant.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 August 2025
Resolved
At each inspection the marine inspector shall examine all accessible watertight bulkheads. A repair had been made to a section of fire main that passed through the forward watertight bulkhead in the main machinery space, The through penetration for the fire main piping had not been welded on either side. Complete the repair, and NDT. Prior to departing Port Fourchon.
46 CFR 176-25-5 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2025
Resolved 15 August 2025
Resolution: The machinery space watertight bulkhead penetration for the fire main was welded at both sides and had NDT via dye pen. Developer on one side, red dye on the other, with the dye pen satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 August 2025
Resolved
Protection from damage shall be considered, with shields installed to the satisfaction of the [name withheld] filters on all MDE’s 01-04 had bowls other than metal construction and were not protected with flame shields. Add shields prior to departing Port Fourchon.
46 CFR 182.40-1 (a)(ii) (2) ('Old' T)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2025
Resolved 15 August 2025
Resolution: Fuel filters on all MDE’s 01-04 had replaced with those of metal construction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 August 2025
Resolved
At each subsequent inspection the marine inspector shall examine all watertight closures on the deck. The overhead access hatch in main machinery forward of the watertight door to the generator space has significant salt deposit in the port aft corner and needs to be resealed. Prior to departing Port Fourchon.
46 CFR 176-25-5 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2025
Resolved 15 August 2025
Resolution: The access hatch had flat bar welded over it on deck to reseal it. The area was sprayed with the fire pump (60 PSI on the outlet gauge) to leak test it. Satisfactory.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 August 2025
Resolved
At every vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard. Excessive oil accumulation was noted in the bilges around both generators and the #04 MDE. The excessive oil must be removed prior to departing Port Fourchon.
46 CFR 176.830(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2025
Resolved 15 August 2025
Resolution: The excessive oil accumulations around both generators, and the #04 MDE were verified pumped from the bilges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2025
Resolved
Diesel engine exhaust cooling shall be in accordance with 182.15-15. Water for cooling shall be injected into the exhaust. Considerable salt deposit was noted at the cooling water injection point of the exhaust on the #01 MDE. Assess and repair prior to departing Port Fourchon.
46 CFR 182-20-15 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2025
Resolved 15 August 2025
Resolution: The cooling water injection point of the exhaust on the #01 MDE was cleaned, and a pinhole leak was found. The area was ground down and rewelded arresting the leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2025
Resolved
Except as provided, all engines shall be water cooled. The heat exchanger on the #02 MDE was missing a lower plug and had salt deposit in the area -evidence of a slow leak. Some nonmetallic joints on the raw water-cooling piping of the #04 MDE were not double hose clamped at each end.
46 CFR 182-20-10 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 15 August 2025
Resolution: Verified that a new lower plug was installed on the heat exchanger on the #02 MDE, and that nonmetallic joints on raw water-cooling piping of the #04 MDE were double hose clamped at each end.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 August 2025
Resolved
Suitable covers/guards shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The # 02 MDE was missing a portion of its guard, and both generators had guards around rotating machinery that were not installed.
46 CFR 177.35-15 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 15 August 2025
Resolution: Covers/guards were reinstalled on both generators, and the portion of missing guard on the #02 MDE was renewed and installed.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 13 August 2025
Resolved
Nothing in this part shall be construed as limiting the MI from assuring the seaworthiness of the vessel. The windows at the forward operating station require thorough cleaning or replacement due to poor visibility in their current state.
46 CFR 176.30-1 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 11 November 2025
Resolution: A third-party Southern Glass of Lafourche, INC attended and replaced the windows at the operating station that were causing poor visibility. Two marine windows that were 14 X 33 ½, and one that was 31 X 33 ½.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 August 2025
Resolved
Suitable covers/guards shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. The blower across from the air receivers has a wasted guard and requires replacement.
46 CFR 177.35-15 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 15 August 2025
Resolution: The blower across from the air receiver was fitted with a renewed guard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 August 2025
Resolved
Each life float must be marked for number of persons. That number cannot be greater than the number of persons it is approved for as shown on its nameplate. One life float on the port side was missing its nameplate.
46 CFR 185.604(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 15 August 2025
Resolution: The life float was replaced in kind by one that had a data plate.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 August 2025
Resolved
At each subsequent inspection the marine inspector shall examine all accessible parts of watertight bulkheads and the weather deck. Deck penetrations from the port and starboard generator small discharge containments on the weather deck have fixed piping that leads to dirty oil tanks port & starboard in the aft of the generator space. The pipe penetrations have pinholes near the deck penetration and salt deposit and require repair.
46 CFR 176-25-5 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 15 August 2025
Resolution: The pipes were removed, and the penetrations mechanically plugged within each containment.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 August 2025
Resolved
At all inspections special attention shall be paid that no fire hazards exist. On the #01 MDE light oil staining was noted below the turbo, and a fitting beneath the turbo loose. The area should be cleaned and the fitting.
46 CFR 176.25-10(b) ('Old' T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 15 August 2025
Resolution: On the #01 MDE the light oil staining was cleaned, and a fitting beneath the turbo verified tightened with no leaks.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 August 2025
Resolved
Adequate emergency lighting shall be installed along the line of escape. Emergency light in the passenger area extinguished on e-power - found disconnected. The light was reconnected and functional prior to MI departure.
46 CFR 182.10-1 ('Old' T)
Action required: 10 - Deficiency Rectified
Due 13 August 2025
Resolved 13 August 2025
Resolution: The light was reconnected and functional prior to MI departure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2025
Resolved
Non-conducting mats or grating shall be provided on deck in front and rear of switchboards. A non-conducting mat was not in place at the switchboard. Crew obtained and placed a non-conducting mat prior to MI departure.
46 CFR 182.40-1 (a)(ii) ('Old' T)
Action required: 10 - Deficiency Rectified
Due 13 August 2025
Resolved 13 August 2025
Resolution: Crew obtained and placed a non-conducting mat prior to MI departure.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 13 September 2023
Resolved
Each vessel shall be provided with sufficient firefighting equipment to extinguish any fires which are likely to be encountered in normal operations. Vessel's fire dampners (08+) were bowed, not able to properly prevent air flow and MI was able to place fingers into between the louver and the vent casing.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 September 2023
Resolution: Crew straighten the dampners out to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 September 2023
Resolved
Each vessel shall be provided with sufficient firefighting equipment to extinguish any fires which are likely to be encountered in normal operations. Vessel's fire main piping was spraying from a pinhole leak where the piping led from the ER through a bulkhead.
15SEP2023: Leak was attempted to be rewelded, not sucessful including additional passes. Bulkhead connection is weaping from either threads or likely welded areas. Deficiency is reduced to Prior to Departure (17C).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2023
Resolution: MI attend vessel and tested system for over 5 min. No signs of weeping.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 September 2023
Resolved
Machinery shall be maintained to protect against fire, explosion, machinery, and personnel injury. Fuel soaked rags were located in the fuel connection piping containment creating a potential fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2023
Resolution: Cleared to the satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 September 2023
Resolved
A suitable marine type strainer meeting recommendations or furnished by the engine manufacturer must be fitted in the fuel supply line in the engine compartment. Plastic RACOR fuel filter without metal flame screen was installed on the fuel line for both gensets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2023
Resolution: Bowls were replaced with metal to the satisfaction of the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 September 2023
Resolved
Vessel shall maintain watertight integrity and stability. Rudder Room's Class 1 WTD did not seal and allowed air to flow through the middle starboard side of the gasket and the top port dog was loose.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2023
Resolution: WTD was tieghtened to the satisfaction of the [name withheld] was slightly difficult to close.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 September 2023
Resolved
Vessel shall maintain watertight integrity and stability. Main deck had a leak coming through the main deck and dripping into the engine room above the outboard STBD MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2023
Resolution: Vessel welded hatch for engine removal. Tested with fire hose, sat.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 13 September 2023
Resolved
A vessel must comply with applicable requirements for any radio installations IAW 47 CFR Part 80. Vessel had a non-working MF/SSB radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2023
Resolution: MF/SSB was replaced, tied to GPS and MMSI programed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 September 2023
Resolved
Machinery, equipment, materials and arrangements not covered by standards may be inspected IAW standards acceptable to the OCMI as good marine practice. Vessel's deck boards had loose and rotten wooden planks that created areas that made a safety hazard for tripping and unstable footing for passenger and crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 19 September 2023
Resolution: All rotten boards replaced to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021
Resolved
46 CFR 183.200: Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts; Kitchen oven to be replaced due to exposed electrical switches for oven "start/stop".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2021
Resolution: Vessel replaced stove with a new stove.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 December 2021
Resolved
46 CFR 182.430: Exhaust gas must not leak from the piping; Starboard/ port engine exhaust pipe ls visibly leaking exhaust. Must be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2021
Resolution: Vessel fixed the exhaust leaks on both starboard/ port engines by unwrapping the exhaust and replacing the raw water clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021
Resolved
46 CFR 183.410(a): Each lighting fixture must have a high strength guard; Starboard overhead light guard in engine room must be
replaced due to damage.
Action required: 10 - Deficiency Rectified
Resolved 10 December 2021
Resolution: Guard replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2021
Resolved
46 CFR 183.220(d): All electrical equipment and circuits must be clearly marked and identified; Distribution panel on bridge missing a directory, must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2021
Resolution: Vessel rep created a new directory for the bridge distribution panel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2021
Resolved
46 CFR 177.800(c): Accommodation space must be maintained to minimize fire hazard; Forward state room port side had cardboard covering berthing light, must be removed to prevent fire hazard
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2021
Resolution: Cardboard removed from light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2021
Resolved
46 CFR 177.800(c): Accommodation space must be maintained to minimize fire hazard; Two electrical strips daisy chained together, must be removed from the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2021
Resolution: Electrical strips removed from the accomodation space.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 November 2020
Resolved
"Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew." Vessel did not have railing in stern of vessel. Vessel is required to install a railing to the satisfaction of the OCMI prior to departing with passengers.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 December 2020
Resolved 1 December 2020
Resolution: Railing was installed and images were sent to the inspection team. Deficieny cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 November 2020
Resolved
"Exhaust gas must not leak from piping or any connections." Exhaust piping on port generator had a 12 inch by 4 inch gash allowing the generator room to fill with exhaust gas. Starboard main engine exhaust aft exhaust had significant water leak near the hull penetration point. Both exhaust pipes must be made the meet the requirement that no gas or water leak from the pipe.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 1 December 2020
Resolved 1 December 2020
Resolution: Starboard engine exhaust pipe was repaired and port generator exhaust pipe was replaced. Images were sent to the inspection team. Deficieny cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2020
Resolved
"Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts." Vessel stove has the start/stop button cap removed. Crew members were placing fingers into electrical outlet in order to turn stove on and off. Vessel must install safety device to prevent crew members from directly touching electrical start/stop on stove.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 1 December 2020
Resolved 1 December 2020
Resolution: Start/stop button was installed and images were sent to the inspection team. Deficieny cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2020
Resolved
"All cable and wire must be protected from the weather." Battery wiring on aft outer deck port side of the pilot house had exposed wiring that sheared from the battery. Wiring must be removed or reconnected safely to the battery for use.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 1 December 2020
Resolution: Battery wire was repaired and images were sent to the inspection team. Deficieny cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 August 2019
Resolved
Repairs or alterations to the hull, machinery or equipment that affects the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency; Vsl conducted drydock without making notification to Coast Guard; Provide documentation of all work and repairs made while in drydock; To the Satisfaction of the Coast Guard; Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2019
Resolved 16 August 2019
Resolution: Vsl provided documentation clarifying need to drydock early and what repairs were conducted in dry dock
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 15 August 2019
Resolved
Immediately after the addressing of resultant safety concerns, the owner, agent, master, or PIC of the vessel involved in a marine casualty shall notify the nearest Marine Inspection Office; Vsl did not notify the Coast Guard; Provide clarification; To the satisfaction of the Coast Guard; Prior to departure.
Vsl had un fininshed structural repairs to bulkhead due to damage that was not complete prior to the annual inspection.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 15 August 2019
Resolved 16 August 2019
Resolution: Vsl made repairs to bulkhead and conducted NDT to verify repairs. The vsl rep was informed on reporting standards moving forward
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 15 August 2019
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, and simiar spaces may be examined to determine that they are serviceable and in a sanitary condition; vsl grey water system was not operating properly and filling up the bilge below the MSD; make repairs per manufactures recommendation; to the satisfaction of the coast guard; within two weeks.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2019
Resolved 16 August 2019
Resolution: Vsl made repairs to grey water system per manufactures recommendation.
Lifesaving › Lifefloat › Pendant
Issued 9 November 2015
Resolved
Provide proper securing method for pendants on lifefloats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2015
Resolved 14 November 2015
Resolution: Secured pendants on lifefloats properly.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 November 2015
Resolved
Provide proper method for lifeline on life ring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2015
Resolved 15 November 2015
Resolution: lifeline on life ring properly secured.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 9 November 2015
Resolved
Provide proper securing support for 2 wire in generator room (port side)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2015
Resolved 15 November 2015
Resolution: Securing support for 2 wire in generator room (port side)addressed.
Engineering › Steering Gear System › Rudder Stock
Issued 13 September 2010
Resolved
Prove the Integrity of the rudder stock or replace rudder stock due to deterioration
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 29 September 2010
Engineering › Steering Gear System › Rudder
Issued 13 September 2010
Resolved
Gouge and weld the fillet weld in way of the port rudder gudeon and bottom plate.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 29 September 2010
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 13 September 2010
Resolved
Replace port inboard intermediate shaft bearing due to separation.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 29 September 2010
Electrical › Electrical Distribution System (service) › Neutral Ground
Issued 13 September 2010
Resolved
Prove proper grounding of electrical system in way of electrical motors, outlets and cable in the sewage room
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 13 October 2010
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2010
Resolved
Provide a detailed gauging report for the hull plating in the forward fresh water tank.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 21 September 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 September 2010
Resolved
Properly clean and mount all sea strainers in the engine room.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 29 September 2010
Fire Fighting › Nozzles › Condition
Issued 13 September 2010
Resolved
Renew the deteriorated spool piece for the fire monitor raw water suction.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 13 October 2010
Deck/Cargo › Mooring/Anchoring › Winch
Issued 13 September 2010
Resolved
Provide and install an anchor windless as original to plans.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 13 October 2010
Resolution: Vessel appealed requirement, and it was granted that the vessel is not required to re-install a windlass
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2010
Resolved
Make proper repairs to the Hull extension / Trim tab in way of missing pieces.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 29 September 2010
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2010
Resolved
Make Repairs to pitted weld and hull plates as discussed.
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 8 October 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 April 2003
Resolved
Provide exhaust lagging where missing for inboard port main diesel engine.
Due 25 May 2003
Resolved 25 April 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 April 2003
Resolved
Provide guards for both generators to cover spinning balancer.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2003
Resolved 25 April 2003
Fire Fighting › Fire Pumps › Pressure
Issued 25 April 2003
Resolved
Repair/replace fire pump show proper operation of 60 psi.
Action required: 705 - Other - as specified
Due 25 May 2003
Resolved 25 April 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 19 February 2002
Resolved
PROPERLY SECURE FREEZER IN AUX MACHINERY SPACE LEGACY COMPONENT DESC: SECURE FREEZER
Condition: Improper/Lack of Maintenance
Due 19 February 2002
Resolved 19 February 2002
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 February 2002
Resolved
REPLACE PLUGS REMOVED FROM THE FWD ENGINE ROOM WATERTIGHT BULKHEAD AND THE AFT GENERATOR ROOM WATERTIGHT BULKHEAD
Condition: Improper Installation
Due 19 February 2002
Resolved 19 February 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 19 February 2002
Resolved
PROPERLY REPAIR THE PORT AND STBD GENERATOR EXHAUST HANGER BRACKETS. LEGACY COMPONENT DESC: EXHAUST BRACKETS
Condition: Improper/Lack of Maintenance
Due 19 February 2002
Resolved 19 February 2002
Engineering
Issued 18 February 2000
Resolved
REMOVE ALL FLEXIBLE FUEL HOSES THAT EXCEED 30 INCHES AND REPLACE WITH HOSESIAW 46 CFR 182.720.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Engineering
Issued 18 February 2000
Resolved
DEMONSTRATE PROPER OPERATION OF FWD AIR RECEIVER PRESSURE RELIEF VALVE_x001C_ AFTER GAGE HAS BEEN REPLACED.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000