Records from 2015 to 2025. Most recent: inspection, 10 September 2025.
Documentation record
Registered dimensions (L × B × D)146.2 ft × 30.0 ft × 12.3 ft
Registered tonnagegross 86 / net 59
ITC dimensions (L × B × D)146.2 ft × 30.0 ft × 12.3 ft
ITC tonnagegross 339 / net 101
BuilderHALIMAR SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2011
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portBAYOU LA BATRE, AL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
339 - Convention (Subpart B), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
101 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
10 September 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8231049
2 September 2025
Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8225031
28 January 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8070766
28 November 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7830648
9 August 2023
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7764192
30 January 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7629184
12 October 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7331202
28 December 2020
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7116969
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110314
20 September 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6816431
9 September 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6807187
3 September 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6809212
7 December 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6594744
11 October 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6285504
28 September 2016
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6011769
8 October 2015
Administrative Inspection · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5738578
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 January 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not have interconnected fire detectors within accommodation spaces and staterooms.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2025
Resolved 4 February 2025
Resolution: Vessel provided evidence of installed system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 January 2025
Resolved
ach rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. 03 Life Floats had tape that was not the approved type and/or worn.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2025
Resolved 4 February 2025
Resolution: Vsl. Provided evidence of new tape placed on life floats.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 December 2023
Resolved
Vessels of more than 65' in length shall have a self priming, power driven fire pump. Fire pumps packing gland has excessive leakage. Show proper operation of fire pump. See 705 code below.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 December 2023
Resolved 15 December 2023
Resolution: Objective evidence of packing gland repairs were received.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 February 2023
Resolved
Multiple cracks found on welds and framing in forepeak forward of collision bulkhead between #1 and #2 main transverse frames and up to the 5th longitudinal from the keel. Must submit repair proposal and conduct repairs IAW 46 CFR 176.700(b).
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2023
Resolved 10 February 2023
Resolution: Cracks were ground out and rewelded, they did not penetrate the sideshell. Areas to be re-evaluated at the next dry-dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2023
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. The reach rod for the valve was not able to be accessed. Provide appropriate tool to access reach rod.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2023
Resolved 10 February 2023
Resolution: Reach rod tool was fabricated and proper operation was shown.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2023
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. The bilge pipe in the forepeak was not fitted with a strainer. Install appropriate sized strainer for the bilge pipe.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2023
Resolved 17 February 2023
Resolution: Vessel rep requested reconsideration and submitted approved drawings indicating the forepeak was considered a ballast tank. Reconsideration was approved by SEC MOB.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2023
Resolved
Each battery used in an item of lifesaving equipment, must be replaced during the annual inspection if the expiration of the batter has passed. Ring life buoy water light battery was expired
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2023
Resolved 10 February 2023
Resolution: New life float light was purchased and installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 November 2021
Resolved
Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. The port side, main deck fire hydrant valve was leaking at the stem and due to corrosion not able to be repaired. Replace as original.
46 CFR 181.310(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2021
Resolution: Valve was replaced and tested under pressure.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 4 November 2021
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] was no anchor line on the vessel to attach to the vessel's forward anchor. Additionally, the anchor does not appear to have been moved from its location since construction. Replace the anchor line with one suitable for vessel's route and service, in an accessible location, and prove proper operation of the anchor.
46 CFR 184.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2021
Resolution: Anchor was removed and maintenance performed. Anchor line was replaced and attachment connections to anchor were added.