Records from 1981 to 2011. Most recent: inspection, 28 January 2011.
Inspection history · 30
28 January 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3940793
3 April 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3445469
29 September 2005
Re-Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2503046
2 September 2005
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2485414
12 August 2005
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2466093
16 June 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2392202
14 June 2005
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2381216
18 May 2005
Deficiency Check · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2361351
22 March 2005
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2249188
4 March 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2303610
1 December 2004
MTSA Verification · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2239797
29 November 2004
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2241431
15 November 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2241439
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188804
21 July 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 643615
15 July 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1156575
3 July 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 643616
18 May 1993
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 833756
16 November 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1136518
23 January 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1270135
25 June 1991
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 913857
15 February 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916520
15 February 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218218
8 March 1990
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 903483
28 August 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1351068
26 August 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003021
5 December 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000377
7 November 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301502
21 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975687
14 October 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966958
Engineering › Bilge Water Management System › Pump
Issued 29 September 2005
Resolved
Provide a new portable bilge pump discharge hose. The hose has several holes which could allow total malfunction and the water could not reach overboard if needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 5 October 2005
Resolution: COMPLETED
Electrical › Mast › Lightning Ground
Issued 29 September 2005
Resolved
Repair/replace wire to STBD green navigation light. Wires going to the light from the stand were exposed. The outside insulation was opened exposing the coated wires inside. No bare wires were exposed, just the outside insulation. Light works!
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 5 October 2005
Resolution: COMPLETED
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 29 September 2005
Resolved
Provide 2 flashlights for deck hands. No flash lights on board the barge for crew to operate if needed at night.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Resolution: FLASH LIGHTS WERE ONBOARD PRIOR TO DEPARTURE.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 September 2005
Resolved
Provide/repair portable fire extinguisher holders/mounts. Mounts are all wasted due to the salt water enviroment. Explained to POC that they could use PVC pipe for holders.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2005
Resolved 29 September 2005
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 2 September 2005
Resolved
PROVIDE LOGS FOR VESSEL FROM LAST SIX MONTHS AS REQUIRED BY TENDERING PLAN.
Due 9 September 2005
Resolved 29 September 2005
Resolution: REVIEWED THE MONTH OF SEPTEMBERS LOGS. ALL OTHER LOGS FROM PREVIOUS MONTHS ARE KEPT IN THE OFFICE AT ST. PETERSBURG. POC STATED THAT THE PAST MONTH LOGS ARE LIKE THE BEING REVIEWED. CLEARED DEFICIENCY BECAUSE TO COPY 6 MONTH OF LOGS WOULD NOT BE CONDUCIV
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 2 September 2005
Resolved
PROVIDE UPDATED PASSENGER TRANSFER TENDERING PLAN ON VESSEL.
Due 9 September 2005
Resolved 29 September 2005
Resolution: UPDATED PLAN WAS ON BOARD AND REVIEWED.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 June 2005
Resolved
PROVIDE A CURRENT CERTIFICATE OF DOCUMENTATION. COD EXPIRED 31MAY05.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2005
Resolved 29 September 2005
Resolution: THEY HAVE A VALID COI, JUST CORRECTING NAME OF O/O''S.
Operations/Management › Passenger Operations › Safety Orientation
Issued 16 March 2005
Resolved
Prior to the carriage of passengers, provide and demonstrate an acceptable fendering system as outlined in your accepted tendering plan and COTP order 04-025 dated 12NOV04.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2005
Resolved 18 March 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 March 2005
Resolved
Provide salt resistant clips for water light lanyards (2) as discussed IAW 46CFR199.70(E)(ii).
Condition: Placed in Improper Service
Due 29 March 2005
Resolved 18 March 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 March 2005
Resolved
Label life preserver stowage box with the word "LIFEJACKETS" IAW 46CFR199.70(E). Box was not labeled.
Condition: Improper/Lack of Maintenance
Due 29 March 2005
Resolved 18 March 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 March 2005
Resolved
Prior to the carriage of passengers, repair PORT hand rail, amidships IWO gangway.
Condition: Damaged By Earlier Event
Due 22 March 2005
Resolved 18 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 March 2005
Resolved
Prior to night time operation, repair anchore light. They had removed a light bulb to get a replacement, but have not returned with a new one.
Condition: Improper/Lack of Maintenance
Due 22 March 2005
Resolved 18 March 2005
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 16 March 2005
Resolved
Provide an anchor IAW 46CFR96.07. Barge had an anchor, but when they removed the wench, they never replaced the anchor.
Condition: Improper/Lack of Maintenance
Due 29 March 2005
Resolved 18 March 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 16 March 2005
Resolved
Provide an updated tendering plan. They had the old one onboard.
Condition: Placed in Improper Service
Due 18 March 2005
Resolved 18 March 2005
Engineering › Bilge Water Management System › Pump
Issued 16 March 2005
Resolved
Prior to the carriage of passengers, prove proper operation of dewatering pump. POC could not get pump started during inspection. One hour after inspection, they were able to start pump. Witnessed operation. POC stated they had flooded carburetor.
Condition: Improper/Lack of Maintenance
Due 22 March 2005
Resolved 22 March 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 1 December 2004
Resolved
Provide [name withheld] approved plans for deck modifications, i.e., railing installation, gangway davit 46 CFR 71.65-5 and 71.65-10.
Due 21 June 2005
Resolved 12 August 2005
Resolution: REVIEWED PLANS AND MATCHED TO VSL LAY OUT, ALL SAT.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 1 December 2004
Resolved
Provide [name withheld] plans addressing general arrangement, fire and lifesaving equipment modifications per 46 CFR 71.65-5 and 71.65-10.
Due 21 June 2005
Resolved 12 August 2005
Resolution: REVIEWED PLANS AND MATCHED TO VESSEL, ALL SAT.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 November 2004
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION REFLECTING OWNER OF VESSEL PER 46 CFR 67.
Due 28 February 2005
Resolved 16 June 2005
Resolution: CLEARED FROM 2241431 AND REOPENED IN THIS ACTIVITY 2381216. BARGE COD EXPIRED 31MAY05 AND THEY RENEWED IT ON 15JUN05. TWO WEEKS OF OPERATING WITHOUT A VALID COD.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 November 2004
Resolved
PAY USER FEE $2,215 per 46 CFR 2.10.
Due 28 February 2005
Resolved 28 September 2005
Resolution: FINCEN advised user fee was paid in Feb 2005
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 29 November 2004
Resolved
Demonstrate location of O.N. on interior of barge and marking of homeport and name per 46 CFR Part 67.
Due 11 February 2005
Resolved 14 June 2005
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
Prior to the use of barge, provide approved plans.
Condition: Damaged By Earlier Event
Due 16 November 2004
Resolved 29 November 2004
Resolution: Rcv''d copy of original ABS approved plans for structures.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
Prior to the use of barge, provide a repair proposal for side shell crack IWO FWD rake, PORT side.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 29 November 2004
Resolution: Vessel drydocked for credit and repairs made.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
Prior to the use of barge, repair 12inch crack after repair proposal has been approved by our office.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 29 November 2004
Resolution: Vessel drydocked for credit and permanent repairs made.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
Prior to the use of barge, make all voids ready for inspection. Remove all water from voids so we can inspect bottom plate or provide a belt gauging report.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 29 November 2004
Resolution: Vessel drydocked and ISE completed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
At next dry dock, crop and renew dent-in area IWO center BLKHD, overhead, FWD between #1P & #1S.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 29 November 2004
Resolution: Cropped and renewed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
At next dry dock, crop and renew wasted side frame IWO AFT rake, STBD side.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 29 November 2004
Resolution: Cropped and Renewed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
At next dry dock, crop and renew wasted frames IWO FWD rake, PORT corner.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 29 November 2004
Resolution: Cropped and renewed.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2004
Resolved
At next dry dock, crop and renew 12 inch crease IWO 2P, bottom between long. 1&2, in bay 4.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 29 November 2004
Resolution: Found to be silt built up on bottom prior to the barge being water ballast being pumped. No structrual problem.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 16 November 2004
Resolved
Provide approved stability letter.
Condition: Improper/Lack of Maintenance
Due 16 November 2004
Resolved 16 November 2004
Resolution: Received copy of original stability letter from construction as a freight barge. Will required new stability to be performed.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 2004
Resolved
Provide plans and fixed lighting for barge which is energized by the M/V Ocean Jewel.
Condition: Placed in Improper Service
Due 21 November 2004
Resolved 29 November 2004
Resolution: Portable lighting removed and will be provided by OCEAN JEWEL OF ST. PETERSBURG when vessels are moored together.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 November 2004
Resolved
Remove all portable gas/diesel operating lights and remove wench from barge.
Condition: Placed in Improper Service
Due 21 November 2004
Resolved 29 November 2004
Resolution: All portable lights and prime movers and winch unit removed at drydock.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 November 2004
Resolved
ASAP, remove fuel from wench and provide two Type B-II portable fire extinguishers. Place extinguishers by each portable light unit.
Condition: Placed in Improper Service
Due 16 November 2004
Resolved 29 November 2004
Resolution: Removed winch and portable light units.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 16 November 2004
Resolved
Prior to any welding, provide welders "ABS" welding certificates.
Condition: Unknown
Due 16 November 2004
Resolved 29 November 2004
Resolution: Certs provided for side shell repairs in water. TBSR did repairs for ABS and CG inspectors during drydock period.
Stability › Incline Test › General
Issued 16 November 2004
Resolved
Provide Ballasting Plan/Stability Ltr per 46 CFR 71.65-5(c).
Due 31 December 2004
Resolved 18 May 2005
Resolution: Received copy of MSC stability letter.
Documentation
Issued 16 November 1992
Resolved
PROVIDE ON BOARD A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY AS REQUIRED BY 33CFR130.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993