Records from 1981 to 2012. Most recent: inspection, 25 January 2012.
Inspection history · 38
25 January 2012
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4231346
22 July 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4093432
4 October 2010
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3851012
22 December 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3383551
31 October 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3379519
6 November 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3093220
4 October 2006
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2782814
4 October 2005
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2507333
11 April 2005
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2330948
25 January 2005
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2280560
25 August 2004
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2175886
19 November 2003
Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1948251
28 October 2002
Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1702641
25 October 2001
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1362523
14 October 2000
COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1451617
9 December 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1451479
19 October 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1429021
2 October 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1388624
28 October 1997
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1112968
14 October 1997
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1447770
21 November 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1178528
18 July 1996
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 942714
26 October 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1189043
18 May 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 873756
26 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1170145
7 November 1994
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177954
28 October 1994
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1175983
28 July 1994
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 869963
4 May 1992
COI Inspection · Inclining Experiment
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1254988
11 February 1992
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1254150
22 May 1990
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 917311
7 April 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325465
20 August 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991143
11 June 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299724
18 September 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299949
28 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975757
20 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273189
17 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963644
Communications › Alarms/Indicators › High Water Alarm
Issued 4 October 2010
Resolved
Engine room high water alarm worked however audible alarm sounded at significantly low tone, issued 835 for alarm to be replaced within 14
Action required: 705 - Other - as specified
Due 18 October 2010
Resolved 12 October 2010
Resolution: Attended vessel to witness SAT operation of engine rooms high water alarm. Cleared 01 835
Engineering › Diesel Engine (propulsion-electric) › Gear/Clutch Starter (electric)
Issued 22 December 2008
Resolved
Port Side Main Diesel Engine not starting
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 23 December 2008
Resolution: Port Side Main Diesel Engine starting and working properly as battery is charged and supplying proper starting power.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 December 2008
Resolved
Life Ring missing the name of the vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 23 December 2008
Resolution: Name of vessel placed on life ring.
Lifesaving › Buoyant Smoke Signals › General
Issued 22 December 2008
Resolved
Missing 3 Orange Day Smoke signals.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 23 December 2008
Resolution: 3 additional red hand flares placed on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 December 2008
Resolved
All around white anchor light is inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 23 December 2008
Resolution: Anchor light bulb replaced, all SAT.
Communications › Audible Communications › Horn/Whistle
Issued 22 December 2008
Resolved
Horn inoperable
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 23 December 2008
Resolution: Horn tested, working properly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 December 2008
Resolved
Aspirin and Iodine missing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 23 December 2008
Resolution: Aspirin and Iodine placed in first aid kit.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 December 2008
Resolved
Drills not conducted at this time due to Portside MDE inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 23 December 2008
Resolution: Drills conducted satisfactorily
Lifesaving › Lifefloat › Paddle
Issued 6 November 2007
Resolved
Master of the vesssel must provide two (4 ft) floating paddles for the life float.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2007
Resolved 15 November 2007
Resolution: Two new floatable paddles with the name of the vessel stenciled to them were added to the life float.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 November 2007
Resolved
Master must add or replace Retroreflective Material tape of lifebuoy (Ring buoy).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2007
Resolved 15 November 2007
Resolution: New retro tape was placed on the ring buoy.
Communications › Audible Communications › Horn/Whistle
Issued 6 November 2007
Resolved
Provide or repair ships Horn/whistle. Vessel restricted from operating during times of restricted visibility.
Due 13 November 2007
Resolved 15 November 2007
Resolution: Horn was replaced and is working properly.
Construction/Loadline › Hull › Transverse Frame
Issued 4 October 2006
Resolved
Repair port stern tube. (Taking on water IWO port stern tube to 1/2 frame joint).
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2006
Resolved 20 October 2006
Resolution: Witnessed satisfactory replacement of stern tube.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 4 October 2006
Resolved
Provide name & hailing port on transom.
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 20 October 2006
Resolution: Witnessed name & home port on transom.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 October 2006
Resolved
Provide hook for the #1 fire extinguisher.
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 24 October 2006
Resolution: Witnessed strap around extinguisher cylinder.
Construction/Loadline › Hull › Bracket
Issued 4 October 2006
Resolved
Repair port engine forward inboard engine mount.
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 20 October 2006
Resolution: Witnessed new bolt in mount.
Construction/Loadline › Penetrations › Pipe Flange
Issued 31 October 2005
Resolved
Renew stbd exhaust flex pipe. Drill stop & repair crack at stbd exhaust penetration.
Due 14 November 2005
Resolved 21 November 2005
Resolution: Stbd exhaust flex pipe was renewed. Crack was drill stopped, ground out & welded.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 4 October 2005
Resolved
Stbd tachometer inop.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 31 October 2005
Resolution: Sending unit was found faulty & replaced.
Lifesaving › Lifefloat › Paddle
Issued 4 October 2005
Resolved
Missing one paddle.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 31 October 2005
Resolution: Owner purchased & installed new paddle.
Engineering › Bilge Water Management System › Piping
Issued 4 October 2005
Resolved
Engine space aft bilge suction piping seperated.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 31 October 2005
Resolution: Owners rep replaced all piping in kind.
Construction/Loadline › Hull › Weld
Issued 4 October 2005
Resolved
Broken weld on forward most transverse frame in forpeake.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 9 November 2005
Resolution: Owners rep had re-welded.
Lifesaving › Lifefloat › Float Free
Issued 4 October 2005
Resolved
Provide float free arrangement for life float.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 31 October 2005
Resolution: Owners rep had brackets fabricated to retain the lifefloat in place yet allow it to float free.
Documentation › Certificates/Documents › FCC SSL
Issued 11 April 2005
Resolved
Provide current FCC Radio Operations permitt.
Due 11 May 2005
Resolved 6 May 2005
Resolution: Provided permitt.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2005
Resolved
Provide light for life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2005
Resolution: Provided light.
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 April 2005
Resolved
Replace worn reflective tape on life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2005
Resolution: Replaced tape.
Construction/Loadline › Structures › Superstructure
Issued 11 April 2005
Resolved
Replace window in cabin.
Due 11 May 2005
Resolved 6 May 2005
Resolution: Replaced window.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 April 2005
Resolved
Provide lifejacket donning placard
Due 11 May 2005
Resolved 6 May 2005
Resolution: Provided placard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2005
Resolved
Provide asprin.
Due 11 May 2005
Resolved 6 May 2005
Resolution: Provided asprin.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 April 2005
Resolved
Hydro 3 CO2 extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2005
Resolution: Hydro completed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 April 2005
Resolved
Prove proper operation of steering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2005
Resolution: Proved proper operation.
Construction/Loadline › Hull › Stiffener
Issued 25 August 2004
Resolved
Found cracks in the welds of the stiifeners in the forward peake compartment. Instructed ships representative to grind and repair all cracks as marked by inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 September 2004
Resolution: Inspected welds all satifactory.
Construction/Loadline › Hull › Hull Plating
Issued 25 August 2004
Resolved
Found crack inboard of port exhaust through hull fitting previously drill stopped and still growing however less than one inch in length. Told ships representative to drill stop and weld crack.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 September 2004
Resolution: Inspected welds all satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 25 August 2004
Resolved
Found weld on port exhaust through hull fitting to be cracked. Instructed ships representative to grind and repair weld.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 September 2004
Resolution: Inspected welds all satisfactory
Engineering › Bilge Water Management System
Issued 19 November 2003
Resolved
Prove working operation of bilge high level alarm.
Condition: Improper/Lack of Maintenance
Due 26 November 2003
Resolved 2 December 2003
Resolution: Proved working operations of bilge high level alarm.
Engineering › Bilge Water Management System
Issued 19 November 2003
Resolved
Label Bilge Alarms.
Condition: Placed in Improper Service
Due 19 December 2003
Resolved 2 December 2003
Resolution: Labeled bilge alarms.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 19 November 2003
Resolved
Provide radio operators licence.
Condition: Improper/Lack of Maintenance
Due 19 December 2003
Resolved 2 December 2003
Resolution: Provided radio operators licence.
Electrical › Electric Supply System (service) › Cable
Issued 19 November 2003
Resolved
Clean battery terminals.
Condition: Improper/Lack of Maintenance
Due 19 December 2003
Resolved 2 December 2003
Resolution: Cleaned battery terminals.
Documentation › Certificates/Documents › FCC SSL
Issued 19 November 2003
Resolved
Update FCC Station/Safety certifcates.
Condition: Improper/Lack of Maintenance
Due 19 December 2003
Resolved 2 December 2003
Resolution: Updated certifcates.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 November 2003
Resolved
Provide asprin and eye wash.
Condition: Improper/Lack of Maintenance
Due 19 December 2003
Resolved 2 December 2003
Resolution: Provided asprin and eye wash.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 November 2003
Resolved
Replace transmission cooling hose on STBD MDE.
Condition: Improper/Lack of Maintenance
Due 19 December 2003
Resolved 2 December 2003
Resolution: Replaced hose.
Engineering › Fuel Oil Service System › Hose
Issued 19 November 2003
Resolved
Replace fuel oil return line on Port Engine.
Condition: Improper/Lack of Maintenance
Due 19 December 2003
Resolved 2 December 2003
Resolution: Replaced line.
Engineering › Bilge Water Management System › Piping
Issued 19 November 2003
Resolved
Replace bilge suction lin in way of steering gear.
Condition: Improper/Lack of Maintenance
Due 19 December 2003
Resolved 2 December 2003
Resolution: After removing all rust, found pipe to be solid.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 November 2003
Resolved
On life ring place clip on the end of the water light.
Condition: Placed in Improper Service
Due 19 December 2003
Resolved 2 December 2003
Resolution: Installed clip.
Electrical
Issued 22 May 1990
Resolved
SUBMIT FOR APPROVAL PLANS FOR INSTALATION OF EMERGENCY GENERATOR.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990