MAURY USCG vessel records
← All vessels

MMLP 119

MMLP 119 is a 1981 freight barge. The Coast Guard has recorded 48 inspections since 1981, most recently in September 2009, along with 27 deficiencies, 1 operational control and 1 casualty investigation in 2006.

Records from 1981 to 2009. Most recent: inspection, 2 September 2009.

Built
1981
Last inspected
2 September 2009
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 2 September 2009
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1981–2009)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-53475

Documentation record

Registered dimensions (L × B × D)120.0 ft × 30.0 ft × 8.6 ft
Registered tonnagegross 289 / net 289
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERGERON MARINE, INC. · PEARLINGTON, MS, UNITED STATES · built 1981
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it289 - Regulatory (Subpart C or D), Gross Ton
289 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HAZEL ANN Towing Vessel · MISLE 102906 · 14 September 2006 · activity 2778952

Inspection history · 48

2 September 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3583561
26 June 2009 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3514768
24 July 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3275661
24 May 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2939393
30 April 2007 Administrative Inspection · Hull Examination · Damage Survey · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2919164
12 January 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2868028
15 September 2006 Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2779345
14 September 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2778952
11 July 2006 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2709279
1 August 2005 Periodic Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2447596
14 July 2004 MTSA Verification · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2132539
14 April 2004 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2043961
8 August 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1873309
3 July 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1834065
12 June 2002 Cargo Tank Internal · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1617957
14 March 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1493657
26 December 2001 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1476990
13 April 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1061758
30 November 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1447013
11 April 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 787714
8 April 1999 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1125659
1 April 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 104038
1 May 1998 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 790842
1 May 1998 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1124274
24 March 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1400750
10 April 1997 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1396709
2 April 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374561
11 July 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 647743
3 May 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 191518
11 April 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1436974
3 April 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1148858
3 April 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1148860
14 February 1995 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 843134
29 December 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1160769
25 August 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1175289
17 March 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373998
22 November 1993 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409044
1 April 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 835137
16 March 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953540
2 July 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937608
26 June 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218076
2 February 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890944
10 March 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029865
18 February 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003416
6 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017742
12 November 1985 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304135
10 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971042
11 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278074

Deficiency record · 27

Construction/Loadline › Hull › Stiffener
Issued 24 July 2008 Resolved
Barge Rep is to ensure that all diagonals in Bow rake are to be replaced in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2008
Resolved 25 July 2008
Resolution: Shipyard replaced all diagonals in bow rake.
Stability › Watertight Integrity › General
Issued 15 September 2006 Resolved
1 Do not attempt to refloat MMLP 119 barge with force. Barge is only to be refloated naturally with the tide. Do not pull, tow, or manipulate the barge to free it.
Due 22 September 2006
Resolved 22 September 2006
Stability › Watertight Integrity › General
Issued 15 September 2006 Resolved
2. Once the barge is free and/or vessel begins to refloat naturally contact Sector Houston Command Center at [phone withheld] to inform CG that the barge is beginning to refloat.
Due 22 September 2006
Resolved 22 September 2006
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 15 September 2006 Resolved
3. If the barge does not refloat by 0400, 15Sep06, contact the CG immediately. Operator must submit lightering plan to Sector Houston via fax [phone withheld] for approval.
Due 15 September 2006
Resolved 22 September 2006
Resolution: Lightering plan was submitted and approved.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 15 September 2006 Resolved
4. Operator must have enough hard boom on standby to fully enclose the vessel and barge to prevent possible pollution.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 22 September 2006
Operations/Management › Pollution › Control of Discharge of Oil
Issued 15 September 2006 Resolved
5. Effective immediately the crew must do the following: A) Take depth soundings hourly at the port and starboard quarters, amidships, and port and starboard bow of the barge and log the readings. B) Maintain a constant bridge watch. C) Check all voids hourly for flooding and log entries. D) Monitor and log cargo levels hourly.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 22 September 2006
Stability › Watertight Integrity › General
Issued 15 September 2006 Resolved
6. Once CG permits barge to go to nearest safe moorings, operator must ensure the following: A) An underwater survey of hull is conducted send report to CG. B) Arrange for 3rd party survey of barge
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 22 September 2006
Resolution: Surveryer will fax survey to MSU Galveston.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 8 August 2003 Resolved
Lube oil pump, centerline, is prohibited to operate until the exhaust system and battery box is renewed.
Condition: Improper/Lack of Maintenance
Due 15 August 2003
Resolved 11 August 2003
Deck/Cargo
Issued 8 August 2003 Resolved
All trash, hoses, buckets, and general housekeeping items are to be stowed or removed from barge.
Condition: Improper/Lack of Maintenance
Due 15 August 2003
Resolved 18 August 2003
Deck/Cargo › Holds/Tanks
Issued 8 August 2003 Resolved
Free up or renew dogs on all hatches. LEGACY COMPONENT DESC: Hatch
Condition: Improper/Lack of Maintenance
Due 15 August 2003
Resolved 18 August 2003
Electrical
Issued 1 May 1998 Resolved
REPAIR/REPLACE FWD MIDDLE LIGHT STAND BY 14MAY98.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Deck/Cargo
Issued 1 May 1998 Resolved
PRIOR TO OPERATING CARGO PUMP AND LUBE OIL TRANSFER PUMP, REPLACE SHROUDS FOR BOTH DRIVE SHAFTS.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Deck/Cargo
Issued 1 May 1998 Resolved
REPLACE DANGER SIGNS FOR #2 STBD CARGO TANK HATCH AND PORT HATCH FOR LUBE OIL TANK BY 14MAY98.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Engineering
Issued 1 May 1998 Resolved
STENCIL/LABEL THE EMERGENCY FUEL CUT-OFF VALVE FOR THE CARGO PUMP ENGINE DIESEL OIL TANK BY 14MAY98.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Deck/Cargo
Issued 24 March 1998 Resolved
PROVIDE PROOF OF HYDRO TEST OF ALL CARGO HOSE ON BOARD (EXCEPT WATER).
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Deck/Cargo
Issued 24 March 1998 Resolved
REPAIR THROTTLE CONTROL TO CARGO PUMP ENGINE.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Deck/Cargo
Issued 24 March 1998 Resolved
REPAIR DOGS TO AFT LUBE OIL (DECK TANK) HATCH COVERS.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Lifesaving
Issued 24 March 1998 Resolved
DISCONTINUE USE OF FORWARD POTABLE WATER TANK UNTIL REAPIRS ARE MADE TO THESATISFACTION OF COGNIZANT OCMI ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Deck/Cargo
Issued 24 March 1998 Resolved
MAKE PRESSURE VACUUM VALVES (RANDOM SAMPLING 50%) AVAILABLE (OPEN) FOR INSPECTION BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Deck/Cargo
Issued 24 March 1998 Resolved
REPAIR/REPLACE POWER TAKE OFF COUPLING TO THE CARGO PUMP AT CARGO PUMP ENGINE SHAFT MAIN DECK AFT STBD SIDE.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Deck/Cargo
Issued 24 March 1998 Resolved
OPERATIONALLY TEST/PROVE PROPER OPERATION OF THE REMOTE SHUT-DOWN TO THE CARGO PUMP ENGINE.
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Deck/Cargo
Issued 24 March 1998 Resolved
REPLACE OR REPAIR THE CARGO PUMP DIESEL FUEL OIL SUPPLY TANK. INBOARD SIDEHAS A COCK-EYED PLUG THREADED INTO A HOLE ABOUT 2/3 rd WAY DOWN (STAINED).
Condition: Unknown
Due 24 March 1998
Resolved 24 March 1998
Deck/Cargo
Issued 2 April 1996 Resolved
RENEW THE FADED CARGO TRANSFER PROCEDURE PIPING AND LAYOUT DRAWING.
Condition: Unknown
Due 2 April 1996
Resolved 2 April 1996
Documentation
Issued 2 April 1996 Resolved
PROVIDE EVIDENCE TO SHOW THAT THE INFORMATION REQUIRED BY 33 CFR 155.245 ISAVAILABLE AT A SHORESIDE LOCATION (PLANS FOR DAMAGE STABILITY AND STRUCTURAL CONSIDERATIONS RESULTING FROM A CASUALTY).
Condition: Unknown
Due 2 April 1996
Resolved 2 April 1996
Deck/Cargo
Issued 14 February 1995 Resolved
MAKE PERMANENT REPAIR TO AFT PORT HATCH ON DECK TANK IN MIDDLE OF VESSEL. IN THE MEAN TIME EFFECT TEMPORARY REPAIRS TO ENSURE CARGO OIL DOES NOT LEAKOUT OF HATCH.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Deck/Cargo
Issued 22 November 1993 Resolved
NO PACKAGED CARGO IS TO BE CARRIED ON DECK, AND NO BULK CARGO IS TO BE CARRIED IN #7 OR #8 DECK TANK UNTIL NEW STABILITY LETTER IS RECIEVED FROM MSC.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Deck/Cargo
Issued 22 November 1993 Resolved
SUBMIT AS BUILT DRAWINGS TO MSC FOR APPROVAL FOR ALTERED CARGO TRANSFER SYSTEM.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993

Casualty record · 1

14 September 2006Routine · role: Involved in a Marine Casualty · activity 2778952
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.