HAZEL ANN

Built
1969
Last inspected
30 May 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 30 May 2024
…with no type recorded21
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1994–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP5172
102906
Flag
UNITED STATES
Maury page id
psix-102906

Documentation record

Registered dimensions (L × B × D)53.8 ft × 20.0 ft × 8.3 ft
Registered tonnagegross 86 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENNIE DITTA · HARVEY, LA, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portVENICE, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 1 July 2025 · expires 31 July 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 40 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 12 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 12

Inspection history · 40

30 May 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7923520
15 May 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7913117
25 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7385644
23 June 2021 Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7233772
25 May 2021 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7206171
13 November 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7094494
13 November 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7105022
16 May 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6685989
17 April 2019 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 6670231
23 July 2018 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6492649
23 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6386851
29 November 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6049510
2 September 2016 Deficiency Check · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5987640
3 July 2012 Deficiency Check · DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4369706
13 December 2011 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4207161
17 November 2011 Industry Initiated Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4202508
13 December 2008 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3379445
7 June 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3231712
7 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3233613
26 February 2008 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3153964
9 February 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3144681
8 February 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3991105
2 August 2007 Uninspected Other · Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3018201
1 August 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3016446
1 August 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3016457
6 April 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2908769
14 September 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2778952
20 April 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2630621
22 August 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2472464
22 August 2005 MTSA Verification · Uninspected Other
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2472578
28 February 2005 MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2300926
6 December 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2254465
22 September 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2202354
1 March 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 118506
5 November 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 409678
2 October 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 408551
17 October 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 166120
13 September 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 705262
30 August 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 370049
9 February 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 120104

Deficiency record · 37

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 June 2024 Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. COD passed the expiration date. Obtain valid COD and provide to the satisfaction of the attending marine inspector.
Due 9 July 2024
Resolved 29 July 2024
Resolution: COD Renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Coolant leak observed on the port diesel engine. Provide repairs satisfactory to the attending marine inspector.
Due 9 July 2024
Resolved 27 June 2024
Resolution: Replaced seal stopping coolant leak; see documents for details.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 25 June 2024 Resolved
Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. Hole in stern caused by dryer exhaust. Provide repairs satisfactory to the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2024
Resolved 27 June 2024
Resolution: Patched hole caused by dryer vent; see documents for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 October 2021 Resolved
46 CFR 143.205 - During testing of the port and stbd engine, the tachometer in the engine room and the one on the bridge did not mirror each other. In addition, a Code 14 ( low oil temp alarm) was found on the port engine and a Code 16 (low coolant alarm) was found on the stbd engine. Both engines showed low RPMs. Provide a 3rd party technician’s report attesting to the proper operation of both main engines and rectify the tachometer readings.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 October 2021
Resolution: Vessel submitted technician's report attesting to having troubleshot and fixed RPM gauges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2021 Resolved
46 CFR 143.220 - During inspection of the fuel system, inspector’s found that both RACOR filters were missing bowls underneath. Ensure flame resistant bowls are placed under filters to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 October 2021
Resolution: Vessel submitted pictures of fuel filters with bowls installed underneath.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 21 October 2021 Resolved
46 CFR 143.205 - Hot water tank was wasted towards the bottom In addition, the temperature/pressure relief valve would not re-seat. Repair/replace to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 1 November 2021
Resolution: Received email with picture.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2021 Resolved
46 CFR 16.113 - Provide proof of enrollment in a Drug and Alcohol Policy to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 8 November 2021
Resolution: Received email with enrollment letter.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 October 2021 Resolved
46 CFR 143.400(c) - All distribution panels on board the vessel was missing labeling for the service of each breaker and the amps for each breaker. Update index card accordingly to ensure overcurrent protection is met to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 1 November 2021
Resolution: Received email with picture.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 October 2021 Resolved
33 CFR 159 - Crew was unable to energize the Marine Sanitation Device’s Pump or aerator. Tablets were found in the chlorinator but the system itself did not start. Prove proper operation of MSD to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 October 2021
Resolved 21 October 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 October 2021 Resolved
46 CFR 142.240(a) - 01 portable fire extinguisher was missed during servicing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 October 2021
Resolved 21 October 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 October 2021 Resolved
46 CFR 142.325(e)(3) - Fire nozzle was plastic and was leaking during testing. Replace with a non-corrosive metallic fire nozzle suitable for service.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 21 October 2021
Resolved 21 October 2021
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 May 2021 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 22 August 2021
Resolved 21 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 November 2020 Resolved
(a)A vessel must be operated in accordance with applicable laws and regulation and in such a manner as to afford protection against hazards to life, property , and the environment. Vessel was u/w pushing the MCD 140 and had allision with the LCP 8 that was moored at Carline fleet mm 113 resulting in 6' x 8' x 8" inset on the LCP 8 stbd gunnel, #1 wing void. The Hazel Ann was reported not having any damage and the MCD 140 had very minimal damage, approximately 1' x 1' x 2" inset on bow. [name withheld] shall provide damage survey, repair plan, and transit plan, as applicable to the marine inspector with approval from the marine inspector prior to movement. 46 CFR 140.205(a) 60 C
Action required: 60 - Rectify deficiencies prior to movement
Due 13 November 2020
Resolved 13 November 2020
Resolution: Cleared due to transfer of case to ITV department. Seperate 835 issued by ITV department.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 16 May 2019 Resolved
IAW 46 CFR 140.605(b), a towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. IAW 46 CFR 144.330, the cognizant OCMI may require review of a vessel's watertight and weather tight integrity. Vsl was observed listing significantly to the starboard side. While attending, vessel personnel reported that the common watertight bulkhead between the starboard and port potable watertanks was compromised with undetermined length of crack. Additionally it was observed approx 6-9 inches of water contained in the starboard side wing void of the vessel. Prior to movement, operator shall submit to Coast Guard New Orleans for approval a transit plan to a confirmed repair facility, include actions taken to mitigate list. Prior to resuming operations vsl shall submit for approval to Coast Guard Sector New Orleans, evidence of satisfactory stability/water tight integrity. Evaluation shall be performed by a Naval Architect or Professional Engineer.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2019
Resolved 3 June 2019
Resolution: Received list and stability report from the Professional Engineer.
Stability › Watertight Integrity › General
Issued 2 August 2007 Resolved
UTV has fracture IWO aft rudder compartment causing compartment to Flood. Require Dry-docking for repair prior to operation.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Owner had vessel dry docked and fracture repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (hydraulic)
Issued 2 August 2007 Resolved
Port MDE Clutch assembly was inoperative.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Received mechanics report stating port clutch assembly is operating properly.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 2 August 2007 Resolved
Sewage treatment containment and piping was blocked and ruptured onto the port SSDG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Installed new sewage treatment plant.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 2 August 2007 Resolved
Control panel had was inoperative due to ground fault and had bee turned off.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Ground fault has been repaired and the control panel is operating properly.
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 2 August 2007 Resolved
No emergengy fire pump was designated for vessel, de-watering pump had been used with no spare on board in case of vessel fire.
Action required: 705 - Other - as specified
Resolved 10 August 2007
Resolution: [name withheld] attended the vessle and verified proper operation of the vessels installed fire pump.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 2 August 2007 Resolved
Inoperative Ships whistle.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Crew demonstrated proper operation of ship''s whistle.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 2 August 2007 Resolved
Lines to float light dry-rotted.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Replaced line from water light to life ring buoy.
Engineering › Bilge Water Management System › Pump
Issued 2 August 2007 Resolved
Bilge suction pump was inoperative.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Pump is operating properly.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 August 2007 Resolved
Secure televisions and appliances from shifting while underway.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Crew secured television and appliances.
Engineering › Bilge Water Management System › Valve
Issued 2 August 2007 Resolved
Bilge pump overboard discharge valve needs to be secured
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2007
Resolution: Crew secured valve
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 2 August 2007 Resolved
Repair/Replace sewage tank vent leaks.
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Crew replaced coupling on sewage tank vent.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 2 August 2007 Resolved
Properly install slide bar on switch board in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Crew installed slide bar on switch board in engine room.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 2 August 2007 Resolved
Secure batteries in battery boxes in engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Crew placed blocks in battery boxes to prevent batteries from sliding around.
Fire Fighting › Fire Pumps › Arrangement
Issued 2 August 2007 Resolved
Label fire main remote start
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 August 2007
Resolution: Crew labeled fire pump remote start.
Fire Fighting › Fire Hoses › Location
Issued 2 August 2007 Resolved
Mount fire hoses and nozzle on STBD side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 October 2021
Resolution: Owner had yard install a new fire hose bracket on STBD side of vessel. Owner installed fire hose and nozzle.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 August 2007 Resolved
Repair/Replace emergency lighting in engine room
Action required: 705 - Other - as specified
Resolved 9 August 2007
Resolution: Crew replaced lantern in engine room.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 22 August 2005 Resolved
Properly blank off missing switches in circuit breaker box IWO engine room 33 CFR 160
Condition: Improper Installation
Due 29 August 2005
Resolved 26 February 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 August 2005 Resolved
Remove all oily residue in bilge in way of engine room 33 CFR 160
Condition: Unknown
Due 29 August 2005
Resolved 26 February 2008
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 August 2005 Resolved
Repair/Replace cracked fresh water filter leaking water excessively into engine room bilge 33 CFR 160
Condition: Damaged By Earlier Event
Due 29 August 2005
Resolved 26 February 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 August 2005 Resolved
Repair leaking exhaust manifold on port main engine 33 CFR 160
Condition: Improper/Lack of Maintenance
Due 29 August 2005
Resolved 26 February 2008
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 22 August 2005 Resolved
Repair shaft packing on port main engine. Shaft packing leaking excessively 33 CFR 160
Due 29 August 2005
Resolved 26 February 2008
Documentation
Issued 2 October 1997 Resolved
VESSEL DID NOT HAVE CERTIFICATION PLACARD FOR MSD ON BOARD.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Navigation
Issued 2 October 1997 Resolved
VESSEL DID NOT HAVE UPDATED CHARTS.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997

Recorded names · 1

CLARA ANN (2005–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.