Documentation record
Registered dimensions (L × B × D)65.0 ft × 26.0 ft × 10.0 ft
Registered tonnagegross 113 / net 90
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVERRET SHIPYARD INC · PLAQUEMINE, LA, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it113 - Simplified, Gross Ton
90 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 42 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 42
30 December 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8053023
22 February 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7868601
11 October 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7806589
12 October 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7330891
10 October 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7398412
22 February 2019
Administrative Inspection · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6632571
23 March 2016
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5855130
23 September 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4990207
2 May 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4848767
9 May 2013
MTSA Verification · Industry Initiated Exam · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4588105
14 June 2010
DAPI Audit · Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3766632
24 November 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3639574
17 October 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3347148
13 April 2008
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3183560
13 February 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3147096
26 January 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3970112
11 January 2008
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3130621
31 August 2007
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3043963
29 August 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3042788
14 May 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2930471
26 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2916392
24 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2914836
31 March 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2615151
22 August 2005
Uninspected Other · Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2472305
22 August 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2472464
30 January 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2283652
13 January 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2275192
29 September 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2209164
10 March 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2021893
10 December 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1961989
24 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1953920
23 February 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1749969
20 January 2002
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1480167
29 September 2001
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1521963
16 April 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 131079
2 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 18917
12 September 2000
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1516704
26 January 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274265
13 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771595
31 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 206350
17 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 7484
24 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 146048
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 February 2024
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by chapter 7 and 8 of NFPA 10.
46CFR142.240(a)(1)
Two portable fire extinguishers found substantially under charged in engine room and fiddly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2024
Resolution: Received a satisfactory report from vessel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 February 2024
Resolved
All biges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
46CFR142.220(a)
Excessive oil in engine room bilges
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2024
Resolution: Received a satisfactory report from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 February 2024
Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM.
46CFR134.230(c)
RPM Guages for auxiliary generator engines missing or inoperable in machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2024
Resolution: Vessel submitted satisfactory evidence of corrective action.
Stability › Watertight Integrity › General
Issued 22 August 2005
Resolved
Vessel is directed to transit to the nearest repair facility and effect permanent repairs on the damaged stbd side engine room watertight door IAW 33 CFR 160.111
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Resolution: Repairs made to affected areas. Requirement cleared.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 26 January 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 February 2000
Resolved 14 November 2006
Lifesaving › Lifebuoys › Not on Board
Issued 26 January 2000
Resolved
VESSEL IS MISSING BUOY LIFERING. MUST CORRECT PRIOR TO NEXT DEPARTURE.
Condition: Unknown
Due 26 January 2000
Resolved 14 November 2006