Records from 2008 to 2026. Most recent: inspection, 6 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 15.0 ft × 6.0 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
16 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 2 vessels inspected with it, by name and date; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
6 August 2026
Drydock Exam · Vessel Attendance · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8456742
2 October 2025
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8245555
3 December 2024
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8042416
21 October 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8022375
22 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7774358
24 August 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7542181
12 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7531557
13 August 2021
Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7285674
1 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7047644
13 September 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6810287
17 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6542873
24 July 2018
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6489282
5 July 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6467900
23 August 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6249712
3 October 2016
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6014804
6 September 2016
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5988856
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 November 2024
Resolved
A visual and audible alarm must be provided to indicate high water level in the engine room. Bilge level was in place and operational, but was not permanently mounted. Permanently mount engine room bilge alarm sensor so that it cannot vibrate loose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2024
Resolved 6 December 2024
Resolution: Bilge alarm properly mounted
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 November 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew and the vessel from electrical hazards. A fixed light in the engine room broke from it's mount and was not properly supported. Repair light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2024
Resolved 4 December 2024
Resolution: Light repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2024
Resolved
When using fire buckets in lieu of a fixed fire pump, the fire buckets must be labeled with the words "FIRE BUCKET" and must be stenciled in a contrasting color on each bucket. Label fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2024
Resolved 3 December 2024
Resolution: Fire buckets labeled
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Complete annual servicing for portable fire extinguishers and fire boy system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2023
Resolved 25 August 2023
Resolution: All fire extinguishers and fire boy serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2023
Resolved
A vessel must carry one floating waterlight. Repair or replace floating electric light on ring life buoy. Vessel is restricted to daylight only operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 6 September 2023
Resolution: New light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 August 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel is missing required portable hand pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 25 August 2023
Resolution: Portable hand pump placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 August 2022
Resolved
A vessel on a lakes, bays, and sounds route must carry 3 red hand flares and 3 hand orange smoke distress signals. Replace 3 hand orange smoke distress signals.
46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 24 August 2022
Resolution: Flares placed onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 12 August 2022
Resolved
Piping which exceeds 150 degrees F must be suitably insulated. Properly insulate generator jacket water expansion tank.
46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 24 August 2022
Resolution: Insulation installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 August 2022
Resolved
All machinery must be maintained in such a manner to afford adequate protection from causing fire or machinery failure. Repair or replace lube oil dipstick on generator.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 24 August 2022
Resolution: Dipstick Replaced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 September 2019
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with attached lanyard. One fire bucket was found rusted through on bottom. Replace wasted fire bucket. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 2 October 2019
Resolution: Vessel purchased new fire bucket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 September 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Install metal support bands on wiring run in forward space, behind pilot house control consul. 46 CFR 183.340(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2019
Resolved 2 October 2019
Resolution: Recieved photo evidence via email that vessel had installed metal bands for wiring support.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 September 2019
Resolved
Wire connectors utilized in conjunction with screw type terminal blocks must be of the captive type. Replace wire connections on the terminal blocks in forward space, behind pilot house control console, with the ring or flanged spade type connectors. 46 CFR 183.340(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2019
Resolved 2 October 2019
Resolution: Recieved photo evidence via email that vessel had installed captive type terminal wire connectors.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 5 July 2018
Resolved
Repair damaged superstructure to the satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 18 September 2018
Resolution: Repairs were inspected during annual inspection. All repairs satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 August 2017
Resolved
Post sign prohibiting passengers access to pilothouse and forward cabin.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 13 September 2017
Documentation › Certificates/Documents › FCC SSL
Issued 23 August 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 13 September 2017
Navigation › Piloting/Steering › Marine Charts
Issued 23 August 2017
Resolved
Obtain updated charts or correct charts currently on hand.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 13 September 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2016
Resolved
Crew was not available to conduct drills. CG Marine Inspector will need to witness drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2016
Resolved 3 October 2016
Resolution: Drills completed to satisfaction of attending USCG Marine Inspectors.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 September 2016
Resolved
Visual and audible alarm at the operation station must indicate a high water level in unmanned spaces. Bilge alarm was not responding in 4 spaces.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 9 September 2016
Resolution: Technician replaced fuses. Verified the audible and visual alrams worked at the operating station.