HELEN G CALYX

HELEN G CALYX is a 2006 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2007, most recently in August 2026, along with 27 deficiencies and 2 casualty investigations between 2008 and 2018.

Records from 2007 to 2026. Most recent: inspection, 6 August 2026.

Built
2006
Last inspected
6 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD4861
862000
Flag
UNITED STATES
367150190
Maury page id
psix-862000

Inspections, by type

…with no type recorded2
Years with a record 17 calendar years (2007–2026)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 15.0 ft × 6.0 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD4861MMSI 367150190 · active · compulsorily equipped · granted 31 August 2016, expires 10 November 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

M/V PEARL Towing Vessel · MISLE 67402 · 24 July 2018 · activity 6489282GD 907 Freight Barge · MISLE 352573 · 24 July 2018 · activity 6489282IB979 Tank Barge · MISLE 52000 · 13 April 2008 · activity 3183560CHARLES W. CLARK Towing Vessel · MISLE 379414 · 13 April 2008 · activity 3183560

Inspection history · 26

6 August 2026 Drydock Exam · Vessel Attendance · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8456742
2 October 2025 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8245555
3 December 2024 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8042416
21 October 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8022375
22 August 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7774358
24 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7542181
12 August 2022 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7531557
13 August 2021 Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7285674
1 September 2020 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7047644
13 September 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6810287
17 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6542873
24 July 2018 Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6489282
5 July 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6467900
23 August 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6249712
3 October 2016 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6014804
6 September 2016 COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5988856
15 August 2014 Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4955343
24 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4230965
12 July 2011 Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4079057
23 November 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3900145
7 October 2008 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3340310
30 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3284066
25 April 2008 Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3192262
13 April 2008 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3183560
13 April 2008 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3184718
13 November 2007 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3126617

Deficiency record · 27

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 November 2024 Resolved
A visual and audible alarm must be provided to indicate high water level in the engine room. Bilge level was in place and operational, but was not permanently mounted. Permanently mount engine room bilge alarm sensor so that it cannot vibrate loose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2024
Resolved 6 December 2024
Resolution: Bilge alarm properly mounted
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 November 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew and the vessel from electrical hazards. A fixed light in the engine room broke from it's mount and was not properly supported. Repair light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2024
Resolved 4 December 2024
Resolution: Light repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 November 2024 Resolved
When using fire buckets in lieu of a fixed fire pump, the fire buckets must be labeled with the words "FIRE BUCKET" and must be stenciled in a contrasting color on each bucket. Label fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2024
Resolved 3 December 2024
Resolution: Fire buckets labeled
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Complete annual servicing for portable fire extinguishers and fire boy system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2023
Resolved 25 August 2023
Resolution: All fire extinguishers and fire boy serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2023 Resolved
A vessel must carry one floating waterlight. Repair or replace floating electric light on ring life buoy. Vessel is restricted to daylight only operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 6 September 2023
Resolution: New light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 August 2023 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel is missing required portable hand pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2023
Resolved 25 August 2023
Resolution: Portable hand pump placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 August 2022 Resolved
A vessel on a lakes, bays, and sounds route must carry 3 red hand flares and 3 hand orange smoke distress signals. Replace 3 hand orange smoke distress signals. 46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 24 August 2022
Resolution: Flares placed onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 12 August 2022 Resolved
Piping which exceeds 150 degrees F must be suitably insulated. Properly insulate generator jacket water expansion tank. 46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 24 August 2022
Resolution: Insulation installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 August 2022 Resolved
All machinery must be maintained in such a manner to afford adequate protection from causing fire or machinery failure. Repair or replace lube oil dipstick on generator. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 24 August 2022
Resolution: Dipstick Replaced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 September 2019 Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with attached lanyard. One fire bucket was found rusted through on bottom. Replace wasted fire bucket. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2019
Resolved 2 October 2019
Resolution: Vessel purchased new fire bucket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 September 2019 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Install metal support bands on wiring run in forward space, behind pilot house control consul. 46 CFR 183.340(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2019
Resolved 2 October 2019
Resolution: Recieved photo evidence via email that vessel had installed metal bands for wiring support.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 September 2019 Resolved
Wire connectors utilized in conjunction with screw type terminal blocks must be of the captive type. Replace wire connections on the terminal blocks in forward space, behind pilot house control console, with the ring or flanged spade type connectors. 46 CFR 183.340(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2019
Resolved 2 October 2019
Resolution: Recieved photo evidence via email that vessel had installed captive type terminal wire connectors.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 5 July 2018 Resolved
Repair damaged superstructure to the satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 18 September 2018
Resolution: Repairs were inspected during annual inspection. All repairs satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 August 2017 Resolved
Post sign prohibiting passengers access to pilothouse and forward cabin.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 13 September 2017
Documentation › Certificates/Documents › FCC SSL
Issued 23 August 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 13 September 2017
Navigation › Piloting/Steering › Marine Charts
Issued 23 August 2017 Resolved
Obtain updated charts or correct charts currently on hand.
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 13 September 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2016 Resolved
Crew was not available to conduct drills. CG Marine Inspector will need to witness drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2016
Resolved 3 October 2016
Resolution: Drills completed to satisfaction of attending USCG Marine Inspectors.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 September 2016 Resolved
Visual and audible alarm at the operation station must indicate a high water level in unmanned spaces. Bilge alarm was not responding in 4 spaces.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 9 September 2016
Resolution: Technician replaced fuses. Verified the audible and visual alrams worked at the operating station.
Fire Fighting › Fire Bucket › Quantity
Issued 12 July 2011 Resolved
Provide one additional fire bucket
Due 13 October 2011
Resolved 19 October 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 July 2011 Resolved
Relabel e/r vent closures "Close in case of engine room fire"
Due 13 October 2011
Resolved 19 October 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 July 2011 Resolved
Repair stbd running light
Due 13 October 2011
Resolved 19 October 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 July 2011 Resolved
Relabel vessel name on life ring
Due 13 October 2011
Resolved 19 October 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 November 2010 Resolved
Provide service report for fixed fire fighting system in engine room.
Action required: 705 - Other - as specified
Resolved 29 November 2010
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 23 November 2010 Resolved
Provide means for maintaining passenger count ashore
Action required: 705 - Other - as specified
Resolved 29 November 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 July 2008 Resolved
Vessel is permited to transit to Baton Rouge AOR without a COI, but is required to attain its COI prior to passenger operations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2008
Construction/Loadline › Hull › Hull Plating
Issued 16 April 2008 Resolved
Prior to commencing any repairs, provide a detailed repair proposal to the cognizant OCMI for review and authorization. Repairs shall be completed to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 30 July 2008
Construction/Loadline › Hull › Hull Plating
Issued 13 April 2008 Resolved
Present vsl to the local Coast Guard Marine Safety Office for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2008

Casualty record · 2

13 April 2008Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 20 injured · activity 3183560
24 July 2018Routine · role: Involved in a Marine Casualty · activity 6489282
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.