Records from 1981 to 2025. Most recent: inspection, 13 November 2025.
Inspection history · 56
13 November 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8267341
13 August 2024
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7980489
9 November 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7821891
30 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7601082
27 July 2021
Drydock Exam · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7271389
24 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6985371
1 July 2019
Internal Structural Exam · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6731793
30 October 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6570929
2 February 2018
Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6349270
25 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6294734
13 October 2017
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6286841
29 July 2016
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5955815
20 July 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5947274
20 June 2014
Annual Inspection · Drydock Exam · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4893268
17 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4381121
30 September 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4163155
10 July 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3263520
9 May 2006
COI Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2645147
13 April 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2333192
8 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2305949
1 July 2004
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2117533
10 March 2004
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2021961
28 May 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1803662
11 July 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1646893
2 May 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451679
27 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 767214
24 July 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3672
18 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 190675
12 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384504
13 April 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 104723
6 May 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 62501
27 April 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456689
1 May 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453484
14 April 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418151
10 July 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 764861
13 June 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 190674
7 June 1996
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445095
27 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 32155
13 April 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447443
31 May 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423952
16 April 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461510
8 May 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410727
9 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235682
18 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914829
7 February 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213930
14 September 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 908688
11 July 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906610
30 April 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213145
23 February 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918738
12 May 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1279848
18 November 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1023913
6 February 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 993394
27 September 1985
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1299321
3 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287410
22 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285699
18 December 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975505
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 November 2025
Resolved
There must be ground detection for each ships power system.
Switchboard indicated ground isolation down to two breakers. 14 and 11.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2025
Resolution: Received a tech report attesting to the repairs of the ground located at the aft steering station. Verified the ground indicator was not showing any abnormalities.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2025
Resolved
Non conducting deck covering mat or grating required at switchboard. Matting shredded.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2025
Resolution: Vessel's crew replaced the damaged mat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 November 2025
Resolved
All watertight doors shall be inspected. Watertight door going from mess deck to machinery passageway found wasted at the bottom.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2025
Resolution: Shipyard conducted satisfactory repair of the watertight door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2024
Resolved
Electric installations on vessels must ensure the protection of passengers, crew and other persons, and the vessel from electrical hazards.
Switchboard ground detection system was showing a 1.6 amp ground on ships power.
46 CFR 111.01-1 (Old-J)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2024
Resolved 29 August 2024
Resolution: Photot evidence of tech report and ground detector w/ no ground. See documents tab.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 August 2024
Resolved
Vessels shall be marked as required by parts 67 & 69 of this chapter.
Per part 67, hull markings, to include vessel name and hailing port, must be permanently affixed, made legible, durable and at least 4 inches in height.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 28 August 2024
Resolution: Verified vessel name was permanently marked on the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2023
Resolved
Each switchboard or distribution panel must be totally enclosed. Switchboard is missing blanks.
46 CFR 129.330(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2023
Resolution: Vessel rep provided photos of corrections.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 November 2023
Resolved
Each vessel must be designed and constructed to minimize fire hazards. The fuel transfer pump is not bolted down.
46 CFR 127.220(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2023
Resolution: Vessel rep provided photos of rectified deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 December 2022
Resolved
Vessel is required to complete annual inspection within 3 months before or after each anniversary date. Vessel missed anniversary date by 3 weeks. Conducted annual inspection.
46 CFR 91.279(a)
Action required: 10 - Deficiency Rectified
Due 5 December 2022
Resolved 5 December 2022
Resolution: Conducted annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 11 August 2021
Resolved
Vessel must provide two means of escape in the pilot house. 46CFR92.10-5
both bridge windows intended for egress are sealed. vessel must make both windows operable. vessel must make stbd window operable prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2021
Resolution: [name withheld] AND CLEARED DEF.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 11 August 2021
Resolved
All vessels shall have efficient guard rails on decks and bridges. 46CFR92.25-5(a)
Fly bridge guards were not in place.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 12 August 2021
Resolution: [name withheld] AND CLEARED DEF.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2021
Resolved
Vessels in ocean service shall be fitted with anchors. chains and hawsers in agreement with ABS. 46CFR96.07-5(a)
Vessel was not equipped with anchor recovery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 27 October 2021
Resolution: Vsl rep sent photo of installed anchor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 August 2021
Resolved
Each vessel must meet the requirements in subchapter S.
Each class 1 watertight door in ocean service must be designed to withstand a head of water. 46CFR93.01-1 to 46CFR170.270
Gasket material on weather deck was not permissible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 12 August 2021
Resolution: [name withheld] AND CLEARED DEF.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2021
Resolved
The installation of all marine engineering systems must meet the requirements of subchapter F. Rudder angle indicator must be at both operating steering stations. 46CFR96.03-1 to 46CFR58.25-25
Rudder angle indicator was not provided in main steering station in pilothouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2021
Resolved 27 October 2021
Resolution: Vsl rep sent photographic evidence of installed rudder angle indicator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2019
Resolved
(16) Life jackets onboard were found to be dry rotted due to age. Replace (16) life jackets w/ ones in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2019
Resolution: Cleared to the satisfaction of CG
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 July 2019
Resolved
Vessel's master possessed a restricted radio operator permit. Master is required to have a unrestricted radio operator permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 10 July 2019
Resolution: Cleared to the satisfaction of CG
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 July 2019
Resolved
Provide documentation proving vessel enrollment into Vessel General Permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 24 July 2019
Resolution: Cleared to the satisifaction of the CG.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 July 2019
Resolved
Vessel's AIS was inoperable. AIS must be maintained in effective operating condition IAW 33 CFR 164.46(d)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 10 July 2019
Resolution: Cleared to the satisfaction of CG
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019
Resolved
Ring life buoy plug was wasted. Replace ring life buoy plug or replace entire life ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2019
Resolved 10 July 2019
Resolution: Cleared to the satisfaction of CG
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 October 2018
Resolved
As appropriate for intended voyage, all vessels must carry adequate and up to date nautical charts. Vessel does not carry out chart corrections at appropriate intervals. Deficiency to remain open until next annual inspection. 46 CFR 97.05-5; 705c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2019
Resolution: Cleared to satisifaction of CG.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2018
Resolved
During required inspection of lifesaving equipment all batteries marked with an expiration date must be replaced if expired or within one-year of install if no expiry date given. All ring lifebuoys found with expired batteries in floating water lights. 46 CFR 199.190(F); 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 October 2018
Resolution: Vessel crew obtained new batteries for floating water lights and replaced to satisfaction of attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 October 2018
Resolved
All electrical installations must be maintained to ensure safety during all conditions. Waste oil pump found with power cable wasted, presenting hazard to personnel. Repair prior to use. 46 CFR 111.01-1(a); 705c.
Action required: 705 - Other - as specified
Resolved 5 November 2018
Resolution: Port Captain provided satisfactory evidence of deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2018
Resolved
All nonmetallic flexible hoses must meet SAE J1942 and be maintained as necessary. Starboard main engine found with wasted and non-approved fuel hoses. Replace with appropriate hoses. 46 CFR 56.60-25; 16c.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 5 November 2018
Resolution: Port Captain provided satisfactory evidence of deficiency correction.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 October 2018
Resolved
All Class 1 watertight doors must be capable of withstanding pressure from 10ft head of water. Vessel found with watertight door gaskets made of open-cell foam. Replace with appropriate rubber gaskets. 46 CFR 170.270; 16c.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 5 November 2018
Resolution: Port Captain provided satisfactory evidence of deficiency correction.
Communications › Radio Communications › EPIRB
Issued 29 July 2016
Resolved
No battery date or registration date on EPIRB
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2016
Resolution: Vessel rep provide battery date info and proof of registration
Fire Fighting › Fire Hydrants › Condition
Issued 29 July 2016
Resolved
Valve missing on No. 1 Fire Station
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2016
Resolution: Valve replaced on fire station
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 17 July 2012
Resolved
RAI not working.
Action required: 705 - Other - as specified
Resolved 23 July 2012
Resolution: Received work order ticket from vessel rep.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 July 2012
Resolved
Radar not working.
Action required: 705 - Other - as specified
Resolved 23 July 2012
Resolution: Vessel rep provided work order ticket showing radar was repaired.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 10 July 2008
Resolved
Show proper operation of rudder angle indicator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 10 July 2008
Resolved
Low Water level alarm for stbd generator on bridge was inoperable, show proper operation.
Due 10 August 2008
Resolved 29 July 2009
Resolution: Item not required.
Stability › Watertight Integrity › General
Issued 10 July 2008
Resolved
Replace fwd engine room wtd gasket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 July 2008
Resolved
Install additional emergency light for passageway forward of engine room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 10 July 2008
Resolved
Provide OSHA approved safety harness for rescue platform
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 10 July 2008
Resolved
Provide scramble net for rescue zone for vessel standby service prior to operatings as a stand-by vessel
Due 10 August 2008
Resolved 29 July 2009
Resolution: net onboard and operation checked to verify anchor points and proper length.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 10 July 2008
Resolved
Provide lighting for embarkation station prior to operating a vessel in standby service.
Due 10 August 2008
Resolved 29 July 2009
Resolution: Lights installed and tested.
Fire Fighting › Means of Escape › Blocked
Issued 10 July 2008
Resolved
Emergency escape hatch in engine room did not work easily. Perform maintenance and show proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2008
Fire Fighting › Fire Pumps › Pressure
Issued 10 July 2008
Resolved
Show proper operation of Fire Monitor prior to operating as a stand-by vessel.
Due 10 August 2008
Resolved 29 July 2009
Resolution: new fire monitor installed and tested.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 9 May 2006
Resolved
Stencil embarkation zone.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 30 June 2006
Resolution: Completed
Engineering › Fuel Oil Service System › Hose
Issued 9 May 2006
Resolved
Install chaffing gear on f/o lines on generator as discussed
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 30 June 2006
Resolution: completed
Communications › Internal Communications System › Sound-powered Telephone
Issued 9 May 2006
Resolved
REPAIR ENGINE ROOM SOUND POWERED PHONELIGHT
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 30 June 2006
Resolution: COMPLETED
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 9 May 2006
Resolved
RENEW ALL REFLECTIVE TAPE ON ALL LIFESAVING EQUIPMENT WITH APPROVED TYPE.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 30 June 2006
Documentation › Certificates/Documents › Stability Letter
Issued 1 July 2004
Resolved
Provide stability letter.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Stability letter placed on board.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 July 2004
Resolved
Provide lenses for engine room light fixtures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Light fixtures replaced.
Communications › Radio Communications › EPIRB
Issued 1 July 2004
Resolved
Provide EPIRB registration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2004
Resolution: EPIRB reregistered.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 1 July 2004
Resolved
Provide means to connect anchor line to anchor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Shackle provided.
Accommodation/Occupational Safety › Ventilation › General
Issued 1 July 2004
Resolved
Install lens cover for range hood lamp
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Replaced range hood.
Stability › Watertight Integrity › General
Issued 1 July 2004
Resolved
Replace cracked pilot house window.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Window replaced.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 1 July 2004
Resolved
Repair rudder angle indicator.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2004
Resolved 30 June 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 July 2004
Resolved
Repair fuel oil reach rods
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Reach rods repaired
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 July 2004
Resolved
Repair ground on switch board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Repaired A/C unit motor.
Deck/Cargo › Ballast › Valves
Issued 1 July 2004
Resolved
REpair forepeak reach rod.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Reach rod repaired.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 July 2004
Resolved
Provide back up power supply for 1 VHF & SSB radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Back up battery provided.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 1 July 2004
Resolved
Provide storm rails for stove.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Rails provided.
Stability › Watertight Integrity › General
Issued 1 July 2004
Resolved
provide safety chain for engine room escape hatch and replace gasket
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Chain and gasket replaced.
Lifesaving › Lifefloat › Serviceable
Issued 1 July 2004
Resolved
Replace both life flats and paddles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2004
Resolution: Both life floats and all paddles replaced.
Fire Fighting
Issued 28 May 2003
Resolved
Lable pilot house main engine shut downs. LEGACY COMPONENT DESC: Main Engine Shut Downs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2003
Resolution: Lables were fabricated and installed during inspection.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 May 2003
Resolved
Provide on board upon reciept CG Certificate of Documentation.
Action required: 705 - Other - as specified
Resolved 3 June 2003
Resolution: Document placed onboard upon reciept.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 July 2002
Resolved
GALLEY EMERGENCY LIGHT INOPERABLE.
Due 11 July 2002
Resolved 11 July 2002
Navigation › Piloting/Steering
Issued 11 July 2002
Resolved
COMPASS DEVIATION TABLE NOT UPDATED. LEGACY COMPONENT DESC: Compass Deviation Table
Due 11 July 2002
Resolved 11 July 2002
Navigation › Piloting/Steering
Issued 11 July 2002
Resolved
RUDDER ANGLE INDICATOR INOPERABLE. LEGACY COMPONENT DESC: RUDDER ANGLE INDICATOR
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2002
Resolved 11 July 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2002
Resolved
RUNNING LIGHTS BACKING NOT PAINTED MAT BLACK IAW NAVIGATION RULES.
Due 11 July 2002
Resolved 11 July 2002
Navigation › Piloting/Steering
Issued 11 July 2002
Resolved
RUDDER PINS MISSING RETAINERS. LEGACY COMPONENT DESC: RUDDER PINS
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2002
Resolved 11 July 2002
Electrical › Electrical Distribution System (emergency) › Switch
Issued 11 July 2002
Resolved
NO EMERGENCY SHUT OFF SWITCH FOR DIRTY OIL PUMP.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2002
Resolved 11 July 2002
Fire Fighting
Issued 9 May 1991
Resolved
PROVE PROPER OUTPUT (500 G.P.M. OR GREATER) FOR FIRE MONITOR PRIOR TO OPERATING IN STANDBY SERVICE IN ACCORDANCE WITH 33 CFR 143 SUBPART E.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Deck/Cargo
Issued 30 April 1990
Resolved
PROVIDE COAST GUARD APPROVED PLANS SHOWING CARGO TANK, PIPING AND CARGO PUMPING ARRANGEMENT.
Condition: Unknown
Due 30 April 1990
Resolved 30 April 1990
Navigation
Issued 22 February 1985
Resolved
REPAIR RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985