Records from 1981 to 2025. Most recent: inspection, 12 November 2025.
Inspection history · 92
12 November 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8267472
17 January 2025
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8080810
30 September 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8011518
11 January 2024
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7848034
14 January 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7621534
1 November 2022
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7587395
28 September 2022
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7567909
19 November 2021
MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7354265
12 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7173834
7 October 2020
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7071659
18 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7036279
2 October 2019
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6826664
10 September 2018
Internal Structural Exam · Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6537282
26 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6361816
25 September 2017
COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6272370
7 October 2016
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6021021
7 September 2016
Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5995773
21 September 2015
Internal Structural Exam · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5214129
17 October 2014
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5015536
8 December 2011
Excursion Permit
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4204579
8 January 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3929340
1 October 2010
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3862834
20 September 2010
Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3853639
7 May 2009
Damage Survey · Drydock Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3470795
3 December 2008
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3373262
12 November 2008
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3361807
26 July 2007
Deficiency Check · Plan Review "T" Boat · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3037963
20 July 2006
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2719484
29 June 2005
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2406889
15 June 2005
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2389601
1 April 2005
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2675225
23 June 2004
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2106749
18 September 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1905647
2 June 2003
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1808090
21 October 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1694294
19 June 2002
Deficiency Check · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1662411
8 August 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1070466
2 July 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443212
11 September 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822200
15 August 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 135488
15 August 2000
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821609
20 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468152
14 January 2000
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 693152
3 September 1999
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511166
25 June 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451421
16 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1122886
20 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390853
10 July 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446511
3 March 1997
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1105707
15 January 1997
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1368015
2 January 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411210
19 September 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1183269
10 January 1995
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355090
18 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1170967
17 February 1994
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1164432
3 February 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1162585
24 January 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 171920
13 July 1993
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 846107
22 April 1993
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1134985
2 February 1993
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 840158
6 October 1992
Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473064
15 May 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 676513
8 January 1992
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1261127
20 December 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1458957
10 December 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 946548
22 May 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 921522
3 May 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1221713
8 April 1991
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230110
4 April 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1228457
11 December 1990
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1239849
31 July 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 908556
22 January 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1242443
10 January 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1222288
14 February 1989
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1344043
14 January 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897229
6 October 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197621
24 March 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 986561
17 April 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1308745
7 April 1987
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1328563
21 October 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1317891
1 July 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306520
25 April 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1001553
10 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 998996
10 December 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 989755
31 May 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287911
25 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 982162
18 October 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975920
2 October 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978963
13 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275237
1 July 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278082
17 December 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272343
22 December 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272292
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 October 2022
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system. Emergency lighting shall be fitted along the line of escape in vessels having lounge areas below the main deck. Marine Inspectors identified insufficient emergency lighting illumination within below deck crew/passenger lounge and corridor. Replace and/or renew lighting arrangements.
46 CFR 184.30-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2022
Resolved 1 November 2022
Resolution: Verified adequate emergency lighting sufficient emergency lighting illuminated within below deck crew/passenger lounge and corridor.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 October 2022
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency exits leading from below deck crew/passenger lounge and corridor were found without markings. Provide markings at all emergency exits and escape hatches.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2022
Resolved 1 November 2022
Resolution: Verified emergency exists leading from below deck crew/passernger lounge and corrider are properly marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 October 2019
Resolved
One length of fire hose must be provided for each fire hydrant required. The hose at one of the required stations onboard was found non-serviceable and requires replacement. Replace non-serviceable fire hose with a serviceable one to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 October 2019
Resolved 3 October 2019
Resolution: Vessel acquired and conducted satisfactory operational test on the replacement fire hose.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2019
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. The alcohol testing devices on board the vessel were found to have expired in July 2019. Alcohol testing devices must be replaced to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2019
Resolved 7 October 2019
Resolution: Vessel rep provided objective evidence the required alcohol test strips were onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2019
Resolved
An adult life jacket must be provided for each person carried onboard a vessel. Vessel only had 57 serviceable adult life jackets onboard, COI is endorsed for the carriage of 61 total personnel. Passenger count is reduced to 57 total personnel until additional life jackets are placed onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 October 2019
Resolution: COI was amended for a reduced total personnel allowed onboard. Vessel has the required lifejackets for the new total personnel permitted.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 October 2019
Resolved
All firefighting equipment onboard must be in a serviceable condition and crewmembers must be familiar with the use and location of firefighting equipment onboard. MIs observed the foam eductor on the main deck was not properly serviced and the crewmembers were inadequately prepared to use the eductor in a reasonable amount of time. Incorporate the maintenance and training in use of the foam eductor into the vessel’s maintenance and training plan respectively.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 3 October 2019
Resolution: Vessel incorporated foam eductor maintenance and training into its monthly checks.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2019
Resolved
Cooking appliances must be installed to prevent movement in heavy seas and provided with grab rails. MIs observed the oven was secured using a ratchet strap causing a fire hazard. Properly secure the oven so as not to cause a potential fire hazard and provide grab rails to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 3 October 2019
Resolution: Vessel removed ratchet strap and installed grab rails.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 October 2019
Resolved
Each vessel must carry adequate and up to date U.S. Coast Pilot [name withheld] List, and Tide tables for the intended voyage. Vessel’s nautical publications were not up to date. Provide vessel with up to date publications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 3 October 2019
Resolution: Vessel has purchased the required updated nautical publications.
Construction/Loadline › Hull › Transverse Frame
Issued 25 September 2017
Resolved
Broken weld in forepeak lower starboard side in way of transverse stiffener and side shell. Repair to satisfaction of attending MI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2018
Resolved 10 September 2018
Resolution: weld pick up completed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 September 2015
Resolved
Vessels alcohol testing devices(saliva) are expired. Vessel shall replace testing devices and is required to meed 2 hour testing requirement. 46CFR16.240
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 24 September 2015
Resolution: Confirmed presence of valid alcohol testing devices(saliva)
Navigation › Piloting/Steering › Marine Charts
Issued 21 September 2015
Resolved
Vessel shall provide proof of up to date marine charts or keep up to date Local Notice to Mariners. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 24 September 2015
Resolution: Vessel provided up to date Notice to Mariners/chart corrections
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 September 2010
Resolved
Fire pump control box in engine room and the engine room distribution box in aft steering both had regular silicon instead of Coast Guard approved sealant for the water tight integrity on electrical cables going into boxes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2010
Resolved 1 October 2010
Resolution: Item corrected.
Lifesaving › Lifefloat › Serviceable
Issued 20 September 2010
Resolved
15 man life float has about a 8 inch crack. reduce passenger count to 45 until life float has been repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2010
Resolved 1 October 2010
Resolution: Life Float repaired.
Stability › Watertight Integrity › General
Issued 20 September 2010
Resolved
several bulkhead penatrations in bow void, engine room, and aft steering all have regular silicon instead of CG approved sealant.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2010
Resolved 1 October 2010
Resolution: Item repaired.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 20 September 2010
Resolved
4 old K POK style life jackets had air bladder leaking air.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2010
Resolved 1 October 2010
Resolution: New Life jackets on board.
Fire Fighting › Portable Foam Applicators › General
Issued 7 May 2009
Resolved
Vessel has COI verbage that allows vessel to carry haz cargo on deck with proper fire fight equipment as per 49 CFR 176.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 October 2009
Resolution: Equipment is now onboard
Construction/Loadline › Hull › Hull Plating
Issued 7 May 2009
Resolved
Stern has fracture that runs 3 ft horizontally and vertically.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 June 2009
Resolution: Stern was replaced.
Lifesaving › Lifefloat › Lifeline
Issued 12 November 2008
Resolved
Replace all life lines on all 3 life floats
Due 1 February 2009
Resolved 23 December 2008
Resolution: Received fax with the purchase of replacement 25 man Roe float and included the replacement of 3 lines.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 November 2008
Resolved
Replace 31 PFDs as defined as bad.
Condition: Design Flaw
Due 2 December 2008
Resolved 3 December 2008
Resolution: Received fax of receipt for the purchase of 31 life jackets.
Stability › Weathertight Integrity › General
Issued 26 July 2007
Resolved
Repair broken galss in pilot house windows
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 29 October 2007
Resolution: Windows replaced.
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 June 2005
Resolved
Repair hydraulic leak on Port side ram hose fitting
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2005
Resolution: Cleared
Engineering › Generator (propulsion-electric) › Measurement Circuitry
Issued 15 June 2005
Resolved
Prove proper operation of Hertz meter on generator switch
Due 30 June 2005
Resolved 5 July 2005
Resolution: Cleared
Construction/Loadline › Hull › Hull Plating
Issued 15 June 2005
Resolved
Gouge & reweld 2 fractures in forepeak
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2005
Resolved 5 July 2005
Resolution: Cleared
Communications › Radio Communications › EPIRB
Issued 15 June 2005
Resolved
Renew hydrostatic release on EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2005
Resolution: Cleared
Communications › Radio Communications › EPIRB
Issued 15 June 2005
Resolved
Replace antenna on EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2005
Resolution: Cleared
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 15 June 2005
Resolved
Secure Emergency Escape ladder leading from generator room
Due 30 June 2005
Resolved 5 July 2005
Resolution: Cleared
Engineering › Fuel Oil Service System › Filter
Issued 23 June 2004
Resolved
Provide drip pans/flame shields for fuel filters for MDE's.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2004
Resolved 21 September 2004
Resolution: Drip pans/flame shields installed.
Engineering › Steering Gear System › Rudder Bearing
Issued 23 June 2004
Resolved
Adjust/repair stuffing box on both rudders to prevent excessive movement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2004
Resolved 21 September 2004
Resolution: Rudders repacked and tested sat.
Construction/Loadline › Hull › Weld
Issued 23 June 2004
Resolved
Repair four (4) fractured welds in upper aft starboard corner of rudder room.
Condition: Unknown
Due 21 September 2004
Resolved 21 September 2004
Resolution: Welds gouged and rewelded.
Construction/Loadline › Hull › Weld
Issued 23 June 2004
Resolved
Repair 2 fractured welds on frames behind ladder in rudder room.
Condition: Unknown
Due 21 September 2004
Resolved 21 September 2004
Resolution: Welds gouged and rewelded.
Construction/Loadline › Hull › Weld
Issued 23 June 2004
Resolved
Repair 5 fractured welds in forward protion of fore peak tank.
Condition: Unknown
Due 21 September 2004
Resolved 21 September 2004
Resolution: Welds gouged and rewelded.
Engineering › Steering Gear System › Fastener
Issued 23 June 2004
Resolved
Provide pins in steering rams of sufficient length to allow securing wither either a locknut or cotter pin.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2004
Resolved 21 September 2004
Resolution: New pins installed and secured.
Construction/Loadline › Hull › Hull Plating
Issued 23 June 2004
Resolved
Crop and renew pitted and holed area of side shell on starboard side of engine room behind freshwater pump. Area measures approx. 24" x 48".
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2004
Resolved 16 August 2004
Resolution: Area cropped out and renewed in kind. Repairs sat.
Construction/Loadline › Hull › Hull Plating
Issued 23 June 2004
Resolved
Crop and renew sections of sideshell on both port and starboard sides of engine room behind exhaust baffles where pitting of side shell plating along the longitudinal frames exceeds 50 percent of plate thickness.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2004
Resolved 16 August 2004
Resolution: Three sections of plate were cropped and renewed.
Personnel › Training
Issued 18 September 2003
Resolved
Provide proff of CPR/First aid training for at least 50% of the crew. LEGACY COMPONENT DESC: First Aid/CPR
Condition: Unknown
Due 18 October 2003
Resolved 22 October 2003
Resolution: Training attended and cards provided.
Lifesaving › Buoyant Apparatus
Issued 18 September 2003
Resolved
Renew seapainters on all three life floats. LEGACY COMPONENT DESC: Seapainters
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Seapainters renewed.
Lifesaving › Launching Appliances
Issued 18 September 2003
Resolved
Provide missing tag on weak link on center life float or replace weak link with appropriately rated link. LEGACY COMPONENT DESC: Release Mechanism
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Weak link replaced.
Construction/Loadline › Hull
Issued 18 September 2003
Resolved
Gouge and reweld 5 fractured welds located and marked in fore peak tank. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Fractures gouged and rewelded.
Engineering › Compressed Air System (start air)
Issued 18 September 2003
Resolved
Replace relief valve on starboard air compressor/receiver. Valve failed to reseat after being lifted. LEGACY COMPONENT DESC: Compressor
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Relief valve replaced and tested.
Engineering › Steering Gear System
Issued 18 September 2003
Resolved
Secure hydraulic steering line on aft bulkhead of steering room. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Hydraulic line secured.
Electrical › Electric Supply System (service)
Issued 18 September 2003
Resolved
Secure electric cable on aft bulkhead in steering room. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Electric cable secured.
Engineering › Diesel Engine (propulsion-electric)
Issued 18 September 2003
Resolved
Renew fuel lines leading to and coming from fuel filter oin port generator. LEGACY COMPONENT DESC: Piping (air intake)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Fuel lines renewed.
Engineering › Generator (propulsion-electric)
Issued 18 September 2003
Resolved
Clean windings on both port and starboard generators. LEGACY COMPONENT DESC: Winding
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Windings cleaned of excessive oil and lint.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 September 2003
Resolved
Renew port side middle silencer rubber coupling that is hard, wasted and leaking.
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 22 September 2003
Resolution: Rubber coupling renewed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 September 2003
Resolved
Renew all fractured/wasted hose clamps on exhaust silencers couplings.
Condition: Improper/Lack of Maintenance
Due 22 September 2003
Resolved 22 September 2003
Resolution: Hose clamps renewed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 September 2003
Resolved
Replace 5 Life jackets taken out of service. Pax count reduced to 51 until life jackest replaced. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 October 2003
Resolved 22 October 2003
Resolution: Additional life jackest provided.
Construction/Loadline › Hull › Weld
Issued 19 June 2002
Resolved
Repair 2 fractures in forepeak in way of bracketon foward stem.
Due 19 July 2002
Resolved 12 December 2002
Engineering › Generator (propulsion-electric)
Issued 19 June 2002
Resolved
Repair blowers in generator room.
Due 19 July 2002
Resolved 12 December 2002
Construction/Loadline › Penetrations
Issued 19 June 2002
Resolved
Remove plastic cap in collision bulkhead pipe penetration and replace with appropriate cap or remove pipe penetration passage.
Due 19 July 2002
Resolved 12 December 2002
Construction/Loadline › Hull › Weld
Issued 19 June 2002
Resolved
Repair fracture in lazarette stbd side corner.
Due 19 July 2002
Resolved 12 December 2002
Engineering › Compressed Air System (start air) › Valve
Issued 19 June 2002
Resolved
Clean up or replace stbdside air receiver popofff valve.
Due 19 July 2002
Resolved 12 December 2002
Engineering › Fuel Oil Service System › Valve
Issued 19 June 2002
Resolved
Shorten handle on portside fuel cutoff valve, ensure full closure.
Due 19 July 2002
Resolved 12 December 2002
Construction/Loadline › Structures
Issued 19 June 2002
Resolved
Make repairs to deck hatch dogging device for lazerette. LEGACY COMPONENT DESC: Door
Due 19 July 2002
Resolved 12 December 2002
Navigation › Piloting/Steering
Issued 19 June 2002
Resolved
Provide anti-backing devices on all steering gear connections.
Due 19 July 2002
Resolved 12 December 2002
Engineering › Freshwater Generation System
Issued 19 June 2002
Resolved
Provide valves for port & stbd generator keel cooler piping.
Due 19 July 2002
Resolved 29 January 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 19 June 2002
Resolved
Provide CO2 portable extinguisher for engine room.
Due 19 July 2002
Resolved 12 December 2002
Lifesaving
Issued 2 July 2001
Resolved
INSTALL EMERGENCY LIGHTING IN THE ENGINE ROOM AND GENERATOR ROOM TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTIONS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Unknown
Issued 2 July 2001
Resolved
INSTALL A PUBLIC ADDRESS SYSTEM TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTIONS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Construction/Loadline
Issued 2 July 2001
Resolved
DEMONSTRATE PROPER OPERATION OF RUDDER ROOM HIGH BILGE ALARM TO THE SAISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTIONS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Engineering
Issued 15 August 2000
Resolved
Vessel experienced engine room fire. Vessel to be towed to Amelia, LA fm Fourchon, LA. Provide repair proposal to cognizant OCMI and have vessel available for USCG inspection._x001C_ _x001C_
Condition: Unknown
Due 15 August 2000
Resolved 15 August 2000
Accommodation/Occupational Safety
Issued 2 February 1993
Resolved
REMOVE PAINT STORES IN LOWER ACCOMMODATIONS PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Unknown
Issued 2 February 1993
Resolved
PROVIDE PROOF OF DRUG TESTING COMPLIANCE WITH 46 CFR 16 PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Documentation
Issued 2 February 1993
Resolved
PROVIDE FCC ISSUED COMMUNICATIONS ACT SAFETY RADIO CERTIFICATE PRIOR TO OPERATING VESSEL.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Fire Fighting
Issued 2 February 1993
Resolved
CONDUCT FIRE AND RESCUE DRILL IN PRESENCE OF USCG MARINE INSPECTOR PRIOR TOOPERATING VESSEL.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Construction/Loadline
Issued 10 December 1991
Resolved
PROVIDE CAPTIVE CHAIN/CABLE FOR PEAK TANK DECK OPENING
Condition: Unknown
Due 24 December 1991
Resolved 24 December 1991
Lifesaving
Issued 10 December 1991
Resolved
PROVIDE 2 COAST GUARD APPROVED WEAK LINKS FOR 2 FORWARD MOST LINES
Condition: Unknown
Due 24 December 1991
Resolved 24 December 1991
Lifesaving
Issued 10 December 1991
Resolved
PROPERLY INSTALL AFT MOST WEAK LINK CONNEDTION
Condition: Unknown
Due 24 December 1991
Resolved 24 December 1991
Construction/Loadline
Issued 10 December 1991
Resolved
RETURN #3 WATER TIGHT DOOR LIGHT TO OPERATION
Condition: Unknown
Due 24 December 1991
Resolved 24 December 1991
Lifesaving
Issued 10 December 1991
Resolved
REPAIR/REPLACE INBOARD BUOYANT APPARATUS WATER LIGHT
Condition: Unknown
Due 24 December 1991
Resolved 24 December 1991
Lifesaving
Issued 10 December 1991
Resolved
PROVIDE 2 ADDITIONAL ADULT LIFE JACKETS.
Condition: Unknown
Due 24 December 1991
Resolved 24 December 1991
Engineering
Issued 10 December 1991
Resolved
PROVIDE METAL DRIP PANS FOR "RACOR" FUEL FILTERS
Condition: Unknown
Due 24 December 1991
Resolved 24 December 1991
Lifesaving
Issued 3 May 1991
Resolved
PROVIDE SEVEN (7) CHILD SIZED LIFE PRESERVERS ON BOARD NOT LATER THAN 21MAY91. NO CHILDREN ARE TO BE CARRIED UNTIL THIS ITEM COMPLETED.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Construction/Loadline
Issued 3 May 1991
Resolved
IF VESSEL REMAINS PASSENGER VESSEL VICE CREW BOAT, REMOVE WATER TIGHT DOOR BETWEEN ENGINE ROOM AND GENERATOR ROOM AND PROVE WATER TIGHT TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Engineering
Issued 10 January 1990
Resolved
REPAIR/REPLACE LAGGING ON ALL MAIN ENGINE EXHAUST PIPING WHERE EXHAUST PIPEIS EXPOSED & LAGGING IS LOOSE OR OFF COMPLETELY.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Electrical
Issued 10 January 1990
Resolved
REPAIR/RENEW PORT GENERATOR OVERSPEED SELENOID AND DEMONSTRATE PROPER TEST OF OVERSPEED TRIP IN PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Navigation
Issued 10 January 1990
Resolved
DEMONSTRATE PROPER OPERATION OF RELIEF VALVE ON PORT AIR RECEIVER.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Navigation
Issued 10 January 1990
Resolved
PROVIDE ONBOARD CURRENT USCG LIGHT LIST VOL IV.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Engineering
Issued 14 January 1989
Resolved
REMOVE ALL RED HAND FROM LUBE OIL TANK AND MAKE PROPER REPAIRS TO TANK. MAKE TANK AVAILABLE FOR TESTING BY U.S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 14 January 1989
Resolved 14 January 1989
Unknown
Issued 7 April 1987
Resolved
MAKE PERMANENT REPAIRS TO THE DECK HATCH PORT SIDE. UNTIL REPAIRS ARE MADEHATCH MUST BE KEPT DOGGED WHILE UNDERWAY.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Unknown
Issued 7 April 1987
Resolved
REPAIR AND PROVE OPERATION OF OVERSPEED TRIP ON THE PORT GENERATOR.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987
Electrical
Issued 25 April 1986
Resolved
REPAIR THE TACHOMETER ON THE PORT GENERATOR.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Fire Fighting
Issued 25 April 1986
Resolved
REPAIR THE GASKET ON THE COVER FOR THE STRAINER FOR THE FIRE PUMP.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Deck/Cargo
Issued 25 April 1986
Resolved
REPAIR OR REPLACE THE CAPSTAN HYDRAULIC LINE.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Engineering
Issued 25 April 1986
Resolved
REPAIR OR REPLACE THE TACHOMETERS ON THE STARBOARD AND CENTER MAIN DIESEL ENGINES.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Electrical
Issued 25 April 1986
Resolved
PROVIDE A BLANK FOR THE MAIN CIRCUIT BREAKER PANEL LOCATED IN THE GALLEY.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Fire Fighting
Issued 25 April 1986
Resolved
HYDROSTATICALLY TEST THE NITROGEN BOTTLE ON THE BV FIRE EXTINGUISHER AND FLUFF THE POWDER.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Unknown
Issued 25 April 1985
Resolved
OBTAIN A VALID FCC LICENSE.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985
Unknown
Issued 25 April 1985
Resolved
OPERATIONALLY TEST THE SSB RADIO AND REPORT THE SATISFACTORY TEST BY LETTERTO THIS OFFICE.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985
Lifesaving
Issued 2 October 1984
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON ALL THREE LIFEFLOATS.
Condition: Unknown
Due 2 October 1984
Resolved 2 October 1984
Electrical
Issued 2 October 1984
Resolved
REPAIR THE OVERSPEED TRIP ON THE PORT GENERATOR.
Condition: Unknown
Due 2 October 1984
Resolved 2 October 1984
Navigation
Issued 2 October 1984
Resolved
PROVIDE THE VESSEL WITH NAVIGATION CHART 11341.
Condition: Unknown
Due 2 October 1984
Resolved 2 October 1984