RMS TRITON

RMS TRITON is a 1981 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1982, most recently in December 2023, along with 176 deficiencies and 1 operational control.

Records from 1982 to 2023. Most recent: inspection, 11 December 2023.

Built
1981
Last inspected
11 December 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG5261
Flag
UNITED STATES
338253000
Maury page id
psix-53605

Inspections, by type

…with no type recorded15
Years with a record 36 calendar years (1982–2023)
The 77 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)98.8 ft × 26.0 ft × 8.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEINER FABRICATORS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG5261MMSI 338253000 · active · compulsorily equipped · granted 30 August 2022, expires 7 September 2032
WDA5097MMSI 366816450 · expired · compulsorily equipped · granted 27 May 2011, cancelled 28 August 2021
WUS6818MMSI not assigned · expired · compulsorily equipped · granted 4 March 1999, cancelled 30 May 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RHAPSODY OF THE SEAS Passenger (Inspected) · MISLE 453758 · 7 December 2002 · activity 1774847

Inspection history · 77

11 December 2023 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7837623
15 May 2023 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7689176
20 January 2023 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7624517
6 September 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7552993
12 December 2021 Examination of Repairs · Administrative Inspection · Damage Survey · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7366791
8 February 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7137504
3 December 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7098385
17 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7096690
15 July 2020 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7026723
20 November 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6859430
10 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6831914
11 December 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6595597
15 November 2018 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6581451
5 October 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6282187
20 March 2017 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6108233
18 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5976658
5 July 2016 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5930751
1 October 2015 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5755911
23 July 2015 Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5193197
13 May 2009 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3474222
19 May 2008 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3204658
19 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2968021
6 April 2007 Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2905133
18 September 2006 Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 2781544
14 August 2006 Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2750317
22 July 2005 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2434646
5 April 2005 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2326782
30 July 2003 Examination of Repairs
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1863991
29 July 2003 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1861603
20 May 2003 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1821647
20 March 2003 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1760605
20 March 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1763809
9 December 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1716583
7 December 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1774847
8 May 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1614360
6 May 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1613314
10 December 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 726570
17 July 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 210056
22 May 2001 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1065033
27 March 2001 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468640
14 January 2000 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421774
23 March 1999 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1399061
15 January 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1045735
22 December 1998 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 807552
16 December 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1436160
18 December 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1400692
14 February 1997 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1430348
20 December 1996 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1452238
27 December 1995 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1398375
28 February 1995 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 854657
14 February 1995 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1157088
31 January 1995 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1356988
16 December 1994 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1464562
16 December 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1159690
15 December 1993 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1444769
16 January 1993 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1137802
7 December 1992 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1137755
4 December 1991 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1354114
24 July 1991 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353178
18 October 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212919
4 May 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 911866
20 October 1989 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1045340
18 October 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1352179
31 January 1989 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1208333
13 October 1988 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 886752
4 May 1988 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1345220
22 April 1988 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1342141
9 October 1987 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1013314
2 October 1987 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1011532
4 November 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1013235
24 April 1986 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1306697
25 April 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 985963
19 October 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1282873
1 May 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972877
23 April 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973561
25 April 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277341
21 April 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273904

Deficiency record · 176

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2022 Resolved
46 CFR 182.720 (e) Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Steering hoses are leaking hydraulic. Vessel shall install replacement hoses that meet SAE J-1942 to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2022
Resolution: Replaced steering hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 16 September 2022 Resolved
46 CFR 184.300 A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessel was unable to lower anchor due to anchor binding up on the bow. Vessel shall enact repairs so crew can safely lower anchor to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2022
Resolution: Anchor is now operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2022 Resolved
46 CFR 182.100 All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Low oil pressure alarm on port main engine is inoperable. Vessel shall enact repairs to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2022
Resolution: Alarm is now operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 September 2022 Resolved
46 CFR 180.137(d)(4) Each survival craft required on For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. If the life float or buoyant apparatus does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line that, if synthetic, is of a dark color or is of a type certified to be resistant to deterioration from ultraviolet light. Segment of connection line between life float and painter line is degraded. Remove degraded line segment and splice painter line to life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 September 2022 Resolved
46 CFR 185.604(g) The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Paddles not marked with name of vessel. Mark paddles.
Action required: 10 - Deficiency Rectified
Resolved 16 September 2022
Resolution: Crew stenciled paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2022 Resolved
46 CFR 180.71(c) Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.17. 04 lifejackets found with degraded reflective tape. Renew reflective tape.
Action required: 10 - Deficiency Rectified
Resolved 16 September 2022
Resolution: Renewed reflective tape.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 September 2022 Resolved
33 CFR 155.750(a)(2)(i) The transfer procedures required by § 155.720 must contain, either in the order listed or by use of a cross-reference index page: A line diagram of the vessel's transfer piping, including the location of each valve, pump, control device, vent, and overflow. Marine Inspector observed that there wasn’t any line diagram of the vessel’s oil transfer system onboard or available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2022
Resolution: Crew created diagram.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 6 September 2022 Resolved
46 CFR 185.512(a)(1) An emergency instruction placard containing the following information will satisfy the requirements of § 185.510. (a) Emergency instructions - (1) Rough weather at sea, crossing hazardous bars, or flooding. Marine Inspector observed that the Emergency Instructions onboard did not include instructions for Rough weather at sea, crossing hazardous bars, or flooding.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2022
Resolved 19 September 2022
Resolution: Provided adequate emergency instructions via email. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2022 Resolved
33 CFR 83.33(a) A vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. Bell not installed on vessel. Install bell. 33 CFR 83.33(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2022
Resolution: Crew installed a bell.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 December 2021 Resolved
46 CFR 183.05-10 (1996) If both of the required fixed power bilge pumps are electrically driven, two generators shall be provided. The port generator is inoperable. Make repairs to the satisfaction of the Coast Guard prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 7 January 2022
Resolved 23 December 2021
Resolution: Vessel owner provided video evidence of satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 December 2021 Resolved
46 CFR 180.25-5 (1996) All vessels shall be provided with an approved adult type life preserver for each person carried. 6 out of 40 required life preservers were found to be unserviceable. Destroy these 6 life preservers and place adequate replacements on board. Cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 December 2021
Resolution: Witnessed owner condemn bad life preservers and place adequate replacements on board.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 December 2021 Resolved
46 CFR 177.10-1(a) (1995) Compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. Vessel sustained damage that penetrated hull plating forward of the collision bulkhead as a result of a collision with a barge. Make permanent repairs to the satisfaction of the Coast Guard prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 December 2021
Resolution: Witnessed satifactory repairs and water test at 30 psi.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 February 2021 Resolved
A hatch exposed to the weather must be watertight except for a hatch on a watertight trunk that extends at least 12 inches above the weather deck. STBD side engine room trunk was degraded such that the hatch would not properly seal allowing water to leak into the engine room. Repairs must be made to the trunk to allow the hatch to properly seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 26 March 2021
Resolution: Vessel owner installed new hatch assembly. MI verified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 December 2020 Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. During a test of the emergency power supply for the emergency lighting system, Marine Inspectors observed that the port generator ammeter gauge was indicating a 50 AMPS draw, even though the vessel was utilizing emergency power. Effect repairs to the electrical system in order to demonstrate proper operation of the ammeter on the main switch board to the satisfaction of the attending Marine Inspectors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 16 December 2020
Resolution: MIs witnessed a sat. operational test of the port generator amp. meter.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 November 2019 Resolved
All firefighting equipment onboard must be in a serviceable condition and crew-members must be familiar with the use and location of firefighting equipment onboard. MIs observed crew-members were inadequately prepared to use the foam applicator on the main deck in a reasonable amount of time. Incorporate the maintenance and training in use of the foam applicator into the vessel’s maintenance and training plan respectively.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 November 2019 Resolved
Doors on cooking appliances must be provided with hinges and locking devices to prevent accidental opening in heavy seas. MIs observed oven in galley area did not have a locking device for the door as required by regulation. Install a locking device on the oven door to prevent accidential opening to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2019 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MIs discovered wire nuts were used for a splice in an electrical installation in vicinity of the port main engine. Place wire nuts within an enclosure to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 11 December 2018 Resolved
The person in charge of an oceangoing ship that cannot discharge oily mixtures into the sea in compliance with paragraphs (a), (b), (c) or (d) of this section must ensure that those oily mixtures are _ (1) Retained on board; or (2) Discharged to a reception facility. Inspections of the engine room discovered oily mixtures within a overboard discharge pump that was directly piped overboard with the overboard valve in the open position. Further inspection revealed oily mixtures in the pipe and at the outboard side of the overboard valve. Determine a plan of action to ensure oily mixtures are not pumped to the sea.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2019
Resolved 17 November 2020
Resolution: O/O welded a box under the shaft seal so that water will not mix with bilge water/oil.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2018 Resolved
Ground detection meter inoperable. Unable to prove proper operation of the gauge.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 28 February 2019
Resolution: Witnessed installation and operation of LED style active ground dection sensor added to main switchboard. Def cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 November 2018 Resolved
Visual Distress Signals (flares) expired October 2018
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 18 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 November 2018 Resolved
Smoke detector/alarms inoperable in passenger berthing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 18 January 2019
Lifesaving › Lifefloat › Netting
Issued 27 September 2017 Resolved
02 - 12 person Life Float's have netting that needs replacement. 46 CFR 180.200. Vessel has been ordered to reduce passenger count by 24 until corrected and 835 is cleared.
Action required: 705 - Other - as specified
Resolved 5 October 2017
Resolution: Lifefloats have been replaced with 15 person lifefloats, all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 September 2017 Resolved
Licensees of radio stations are required to have current station documents. Bridge to Bridge Act Safety Certificate // Communications Act Safety Certificate 47 CFR 80.401
Due 14 October 2017
Resolved 5 October 2017
Resolution: FCC documents are up to date with current call sign and have been tested for the current equipment onboard.
Fire Fighting › Portable Foam Applicators › General
Issued 20 March 2017 Resolved
VSL has an endorsement to carry hazardous materials but does not have the required fire protection requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2017
Resolution: Verified additional FF equipment for the carriage of hazmat. All sat.
Lifesaving › Lifefloat › Float Free
Issued 5 July 2016 Resolved
Life Float not stowed in a manner to allow equipment to float unobstructed.
Due 5 July 2016
Resolved 5 July 2016
Resolution: corrected on the spot
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 5 July 2016 Resolved
Emergency spot is not functioning for the port MDE.
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 27 September 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 July 2016 Resolved
No emergency lights exists along the line of escape from the lower berthing space to the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 18 August 2016
Resolution: Vessel rep corrected emergency lighting def.
Electrical › Electric Generation Source (service) › Generator
Issued 23 July 2015 Resolved
#2 SSDG failed to maintain voltage output. Possible cause is loss of excitation. Prove proper operation of #2 SSDG, prior to getting underway, to the satisfaction of the attending USCG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2015
Resolved 6 August 2015
Resolution: O/O installed a new generator (in-kind) to function as the #2 SSDG. MI verified proper operation of the generator to include over speed test. All Sat.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 23 July 2015 Resolved
Smoke detector located in the lower crew quarters has a expired battery. Replace battery and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2015
Resolved 23 July 2015
Resolution: Battery replaced, corrected on the spot
Fire Fighting › Fire Hoses › Condition
Issued 23 July 2015 Resolved
Fire hose located within the engine room has a pinhole leak. Replace fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2015
Resolved 23 July 2015
Resolution: Fire hose replaced, corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 May 2008 Resolved
03 lifejacket had pin hole leaks
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2008
Resolved 19 May 2008
Resolution: corrected on the spot with new lifejackets
Communications › Radio Communications › EPIRB
Issued 19 May 2008 Resolved
Monthly EPIRB test not logged
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2008
Resolved 19 May 2008
Resolution: Witnessed test and master logged in vessel log, corrected on spot
Stability › Watertight Integrity › General
Issued 19 May 2008 Resolved
WTD leading to engine room gasket made of improper material.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2008
Resolved 19 May 2008
Resolution: Corrected on spot with proper gasket.
Construction/Loadline › Hull › Hull Plating
Issued 6 April 2007 Resolved
15' section of rub rail starboard side 30' aft of bow. Numerous fractures and insets.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 May 2007
Resolution: 15'''' section of rub rail cropped and renewed
Construction/Loadline › Hull › Hull Plating
Issued 6 April 2007 Resolved
18' x 5' side shell, 20' aft of bow starboard side numerous insets beyond standards.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 May 2007
Resolution: C/R 18'' x 5'' side shell plating, dye pin test conducted with sat results.
Construction/Loadline › Structures › Trunk
Issued 6 April 2007 Resolved
Two vertical girders at escape trunk starboard side engine comp, deteriorated/wasted
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 June 2007
Resolution: Removed two vertical girders and replaced with new metal welded to existing good metal.
Construction/Loadline › Structures › Trunk
Issued 6 April 2007 Resolved
Two transverse overhead support girders at escape trunk engine room comp, wasted/deteriorated
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 June 2007
Resolution: Removed two transverse overhead support girders and replaced with new metal welded to existing good metal.
Construction/Loadline › Structures › Deck Plating
Issued 6 April 2007 Resolved
Galley floor, starboard side 15' x 15" from side shell to centerline wasted/deteriorated
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 May 2007
Resolution: C/R 15'' x 15'' section of deck plating galley floor
Construction/Loadline › Hull › Hull Plating
Issued 6 April 2007 Resolved
18" x 18" x 3" inset starboard side 10' forward of stern
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 May 2007
Resolution: inserted 20" x 20" insert, dye pin test conducted with sat results
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 April 2007 Resolved
Bilge high level sensor installed to high off deck
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 21 May 2007
Resolution: Moved sensor to lower position
Construction/Loadline › Structures › Deck Plating
Issued 6 April 2007 Resolved
Soft patch covering starboard MDE was not welded or sealed properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 May 2007
Resolution: Welded soft patch
Lifesaving › Lifefloat › Netting
Issued 14 August 2006 Resolved
02 EA. Life Floats netting were wasted with hole torn in them.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2006
Resolution: Corrected with new netting.
Personnel › Training › First Aid/CPR
Issued 14 August 2006 Resolved
50% of the crew did not have CPR Cards
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2006
Resolved 14 August 2006
Resolution: Required personnel were hired with current/valid CPR cards
Navigation › Piloting/Steering › Marine Charts
Issued 14 August 2006 Resolved
Marine Charts were not corrected to lastest NTM.
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 14 August 2006
Resolution: New charts were procured with current corrections
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 August 2006 Resolved
First Aid kit was expired
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2006
Resolved 14 August 2006
Resolution: New First Aid Kit was procured
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 14 August 2006 Resolved
Galley Range Hood ventilation was inoperable
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 14 August 2006
Resolution: repaired and cleared on CG-835
Construction/Loadline › Hull
Issued 30 July 2003 Resolved
Conduct drydock and make permanent repairs to #2 port fuel tank. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Due 5 August 2003
Resolved 30 July 2003
Lifesaving
Issued 27 March 2001 Resolved
Install public address system as per 46 CFR 184.610
Condition: Unknown
Due 30 April 2001
Resolved 8 May 2002
Construction/Loadline
Issued 27 March 2001 Resolved
Repair and prove operation of rudder room bilge alarm.
Condition: Unknown
Due 30 March 2001
Resolved 18 April 2001
Lifesaving
Issued 14 January 2000 Resolved
INSTALL EXTRA TOP RUNG ON ENGINEROOM TO MAIN DECK EMERGENCY EXCAPE AND INSTALL A LATCHING DEVICE FOR HATCH.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 14 January 2000 Resolved
LABEL GALLEY RANGE SHUT-OFF.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Navigation
Issued 14 January 2000 Resolved
INSTALL LOCKING DEVICES/COTTER KEYS ON ALL PINS TO STEERING ASSEMBLY.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 14 January 2000 Resolved
REPAIR/PROVE PROPER OPERATION OF RUDDER ROOM BILGE ALARM.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Navigation
Issued 14 January 2000 Resolved
REPAIR PORT RUDDER PACKING GLAND.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 14 January 2000 Resolved
REPAIR VENT COVER TO MAINDECK ENGINEROOM VENTILATION.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 14 January 2000 Resolved
REPAIR AFT STERN STBD CORNER SO AS TO SAFELY ACCOMODATE WALKWAY SUPPORT.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Fire Fighting
Issued 14 January 2000 Resolved
STENCIL NAME OF VESSEL ON ALL FIRE HOSES.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 14 January 2000 Resolved
REPAIR OPEN/CLOSE DOOR LIGHTS ON BRIDGE PANEL.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Lifesaving
Issued 14 January 2000 Resolved
PROVIDE RESCUE PLATFORM.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Navigation
Issued 14 January 2000 Resolved
REPAIR/PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Navigation
Issued 14 January 2000 Resolved
INSTALL RUDDER ANGLE INDICATOR AT BOTH STEERING STATIONS.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Lifesaving
Issued 14 January 2000 Resolved
INSTALL NEW HYDRO RELEASE FOR EPIRB.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 14 January 2000 Resolved
REPAIR AFT 01 DECK WATER TIGHT DOOR (AROUND GASKET/CORRODED).
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Construction/Loadline
Issued 23 March 1999 Resolved
CROP AND RENEW IN WAY OF CRACKS IN P/S POTABLE WATER TANKS (NUMEROUS IN EACH TANK).
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 23 March 1999 Resolved
REPAIR RUDDER ROOM BILGE ALARM AND ALL WATERTIGHT DOOR ALARMS.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 23 March 1999 Resolved
WELD ANGLE FOR DECK PLATE IN WAY OF FWD ENGINEROOM DOOR ON PORT SIDE.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Engineering
Issued 23 March 1999 Resolved
RENEW PORT AND STBD MDE DIRTY OIL DRAIN LINES.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 23 March 1999 Resolved
HARDPIPE AIR RECEIVER (STBD) SUPPLY LINE OR PROVE ADEQUACY OF FLEX LINE.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 23 March 1999 Resolved
GAUGE BOTTOM PLATING IN ENGINEROOM PORT OF AFT CENTERLINE NEAR KEELCOOLERS.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Navigation
Issued 23 March 1999 Resolved
RENEW PORT RUDDER SEAL/PACKING (LOOSE)
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 23 March 1999 Resolved
CROP AND RENEW 2 INSETS IN WAY OF PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Electrical
Issued 23 March 1999 Resolved
INSTALL SWITCHBOARD TRANSFER SAFETY BAR SO THAT IT CANNOT BE REMOVED.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 23 March 1999 Resolved
RENEW FWD PEAK TANK LADDER RUNGS.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Accommodation/Occupational Safety
Issued 23 March 1999 Resolved
RENEW GRAY WATER PIPING IN OVERHEAD OF #1 STBD BALLAST TANK.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 23 March 1999 Resolved
RENEW BILGE PIPE (UNION) AT SUCTION LINE CENTERLINE PORT ENGINEROOM NEAR SLOP TANK.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 23 March 1999 Resolved
CROP AND RENEW 2 INSETS IN WAY OF F/O TANK PORT SIDE. (NOT IN FUEL TANK) DEFERRED THESE INSETS AT THIS TIME (BALLAST TANK).
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 23 March 1999 Resolved
RENEW FWD STARBOARD BILGE MANIFOLD PIPING AS NEEDED.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Construction/Loadline
Issued 23 March 1999 Resolved
CROPP AND RENEW INSET IN WAY OF PORT SIDE ENGINE ROOM FORWARD OF ITEM #1.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 23 March 1999 Resolved
CLEAN ENGINEROOM BILGES.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Lifesaving
Issued 15 January 1999 Resolved
PROVE THAT THE VESSEL IS SUFFICIENTLY MANEUVEREABLE, ARRANGED AND EQUIPPED TO ALLOW THE CREW TO RECOVER A HELPLESS PERSON FROM THE WATER IAW 46CFR180.210 AND D8 POLICY LTR DTD 12NOV98.
Condition: Unknown
Due 15 March 1999
Resolved 6 April 1999
Construction/Loadline
Issued 16 December 1998 Resolved
Repair sluice valve reach rod forward of collision bulkhead.
Condition: Unknown
Due 16 January 1999
Resolved 23 December 1998
Electrical
Issued 16 December 1998 Resolved
Prove operation of galley door alarm.
Condition: Unknown
Due 16 January 1999
Resolved 23 December 1998
Navigation
Issued 16 December 1998 Resolved
Prove proper operation of steering pump alarm system.
Condition: Unknown
Due 16 January 1999
Resolved 23 December 1998
Deck/Cargo
Issued 16 December 1998 Resolved
Prove proper operation of anchor windlass.
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Construction/Loadline
Issued 16 December 1998 Resolved
Adjust watertight doors at engineroom and galley for proper closure.
Condition: Unknown
Due 16 January 1999
Resolved 23 December 1998
Construction/Loadline
Issued 16 December 1998 Resolved
Prove proper operation of engineroom door indicator.
Condition: Unknown
Due 16 January 1999
Resolved 23 December 1998
Construction/Loadline
Issued 16 December 1998 Resolved
Prove proper operation of bilge alarm system.
Condition: Unknown
Due 16 January 1999
Resolved 23 December 1998
Electrical
Issued 16 December 1998 Resolved
Replace port generator salt water cooling piping.
Condition: Unknown
Due 16 January 1999
Resolved 23 December 1998
Electrical
Issued 18 December 1997 Resolved
Replace electrical junction box on outboard steering pump motor.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Electrical
Issued 18 December 1997 Resolved
Replace all wire nuts with compression connectors.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Electrical
Issued 18 December 1997 Resolved
Place generator start battery in a proper storage box.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Electrical
Issued 18 December 1997 Resolved
Repair Emergency Light in engineroom.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Lifesaving
Issued 18 December 1997 Resolved
Stencil distress flare container "VISUAL DISTRESS FLARES".
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Navigation
Issued 18 December 1997 Resolved
Remove all water from steering space and repack both rudder posts.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Construction/Loadline
Issued 18 December 1997 Resolved
Replace gasket in watertight door from main deck to galley area.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Navigation
Issued 18 December 1997 Resolved
Update Coast Pilot, Charts, Lightlist and Tide Tables.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Construction/Loadline
Issued 18 December 1997 Resolved
Repair cracked welds in 4th and 5th transverse frames in engineroom as marked by the Marine Inspector.
Condition: Unknown
Due 18 December 1997
Resolved 23 December 1997
Construction/Loadline
Issued 27 December 1995 Resolved
Repaint draft marks on both bow and stern, port and starboard.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Construction/Loadline
Issued 27 December 1995 Resolved
Repair dogs on watertight door to blower room.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Construction/Loadline
Issued 27 December 1995 Resolved
Replace dog on watertight door to mess deck.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Construction/Loadline
Issued 27 December 1995 Resolved
Install man screen on blower room intake.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Construction/Loadline
Issued 27 December 1995 Resolved
Replace watertight door on 01 deck, port side to cabin.
Condition: Unknown
Due 27 December 1995
Resolved 2 January 1996
Lifesaving
Issued 27 December 1995 Resolved
Post emergency checkoff on bridge.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Engineering
Issued 27 December 1995 Resolved
Install rotating machinery guard on starboard main engine.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Lifesaving
Issued 27 December 1995 Resolved
label all the vents, fills and piping aft of cabin port side.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Electrical
Issued 27 December 1995 Resolved
Repair electrical junction box on port running light on 02 deck.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Accommodation/Occupational Safety
Issued 27 December 1995 Resolved
Repair or replace wasted hand rail starboard side on 01 deck aft.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Accommodation/Occupational Safety
Issued 27 December 1995 Resolved
Repair or replace wasted ladder on port side of 01 deck.
Condition: Unknown
Due 27 December 1995
Resolved 2 January 1996
Fire Fighting
Issued 27 December 1995 Resolved
Replace valve handle on ballast pump sea suction.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Engineering
Issued 27 December 1995 Resolved
Reapir starboard main engine tachometer on bridge and engineroom.
Condition: Unknown
Due 2 January 1996
Resolved 2 January 1996
Construction/Loadline
Issued 31 January 1995 Resolved
Repair hull on port side fore peak and repair bulkhead longitudinal frames inside of forepeak.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Construction/Loadline
Issued 16 December 1994 Resolved
PAINT DRAFT MARKS ON VESSEL.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
REPLACE CAP ON NO.1 BALLAST PORT VENT PIPE.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Navigation
Issued 16 December 1994 Resolved
INSTALL PROPER BULBS IN NAVIGATION LIGHTS, MOUNT STERN LIGHT.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Lifesaving
Issued 16 December 1994 Resolved
INSTALL NEW CONNECTION RINGS TO WEAK LINKS ON LIFE FLOATS.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Fire Fighting
Issued 16 December 1994 Resolved
REPLACE FIRE NOZZLE ON MAIN DECK FIRE STATION.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
REPAIR BILGE ALARMS IN AFTER STEERING AND ENGINEROOM.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Engineering
Issued 16 December 1994 Resolved
INSTALL NEW KILL SWITCH SOLENOID ON PORT MAIN ENGINE.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Navigation
Issued 16 December 1994 Resolved
REPAIR HYDRAULIC SEALS ON STEERING RAMS.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Engineering
Issued 16 December 1994 Resolved
RENEW BRIDGE ENGINE ALARM SYSTEM.
Condition: Unknown
Due 16 December 1994
Resolved 16 December 1994
Construction/Loadline
Issued 16 December 1994 Resolved
WELD VENT PIPE FOR STERN VOID.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Accommodation/Occupational Safety
Issued 16 December 1994 Resolved
REPAIR GALLEY DOOR ALARM ON BRIDGE.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Lifesaving
Issued 16 December 1994 Resolved
OBTAIN NEW LIGHT FOR 01 PFD.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Documentation
Issued 16 December 1994 Resolved
PROVIDE DOCUMENTATION THAT A NEW RADIO OPERATORS PERMIT HAS BEEN APPLIED FOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Engineering
Issued 16 December 1994 Resolved
INSTALL NEW VALVE HANDLES ON STBD GEN SUCTION VALVE AND #1 PORT FUEL TANK SUCTION VALVE IN ENGINEROOM.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Navigation
Issued 16 December 1994 Resolved
renew steering pump lights on bridge.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Electrical
Issued 16 December 1994 Resolved
CLEAN AIR FILTERS ON GENERATORS. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Engineering
Issued 16 December 1994 Resolved
REPAIR STBD MAIN ENGINE FUEL SHUTDOWN REACH ROD.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Navigation
Issued 16 December 1994 Resolved
REPAIR AUTO PILOT.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Engineering
Issued 16 December 1994 Resolved
REPAIR TACHOMETER ON PORT MAIN ENGINE.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Lifesaving
Issued 16 December 1994 Resolved
OBTAIN 02 RED HANDHELD FLARES AND 01 ORANGE SMOKE.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Accommodation/Occupational Safety
Issued 16 December 1994 Resolved
REPAIR 03 BROKEN WINDOWS ON PILOTHOUSE.
Condition: Unknown
Due 16 December 1994
Resolved 22 December 1994
Construction/Loadline
Issued 15 December 1993 Resolved
Renew wasted/holed bilge pump suction piping.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Accommodation/Occupational Safety
Issued 15 December 1993 Resolved
Renew/remove aft control station window.
Condition: Unknown
Due 16 December 1993
Resolved 16 December 1993
Electrical
Issued 16 January 1993 Resolved
SEAL STEERING GEAR COMPARTMENT WIRE RUN IN WAY OF FORWARD BULKHEAD PENETRATION.
Condition: Unknown
Due 18 January 1993
Resolved 19 January 1993
Lifesaving
Issued 16 January 1993 Resolved
REPAIR SEPERATED WIRE WIRING ON BILGE LEVEL ALARM FLAOT IN STEERING GEAR COMPARTMENT
Condition: Unknown
Due 18 January 1993
Resolved 19 January 1993
Engineering
Issued 16 January 1993 Resolved
REPAIR STARBOARD MAIN DIESEL ENGINE TO REDUCTION GEAR COUPLING FRAME PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 18 January 1993
Resolved 19 January 1993
Construction/Loadline
Issued 16 January 1993 Resolved
REPAIR BILGE FRAMING BELOW STARBAORD MAIN DIESEL ENGINE REDUCTION GEAR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 18 January 1993
Resolved 19 January 1993
Construction/Loadline
Issued 16 January 1993 Resolved
REPAIR CRACKED BULKHEAD AT BILGE FRAME IN WAY OF STARBOARD #3 BALLAST TANK FORWARD BULKHEAD PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 18 January 1993
Resolved 19 January 1993
Electrical
Issued 16 January 1993 Resolved
RENEW WIRE RUN FOR ANCHOR WINDLASS FROM CONTROLLER TO MOTOR.
Condition: Unknown
Due 18 January 1993
Resolved 19 January 1993
Electrical
Issued 7 December 1992 Resolved
INSTALL COVERS ON LIGHT SWITCH AND BUNK LIGHT IN STARBOARD MAIN DECK ACCOMMODATION SPACE.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Unknown
Issued 7 December 1992 Resolved
PAINT VESSEL NAME ON STERN.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Construction/Loadline
Issued 7 December 1992 Resolved
RENEW OR REPAIR ENGINE ROOM ESCAPE HATCH COVER.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Engineering
Issued 7 December 1992 Resolved
DEMONSTRATE FORWARD AND REVERSE OPERATION OF THE STARBOARD MAIN ENGINE.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Construction/Loadline
Issued 20 October 1989 Resolved
GRIND AND REWELD SEPARATED WELD ON STEM, PORT SIDE, UPPER FOREPEAK.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Construction/Loadline
Issued 20 October 1989 Resolved
REPAIR/REPLACE BILGE SHUTOFF VALVE IN LOWER FOREPEAK AND DEMONSTRATE PROPER OPERATION OF REACH ROD.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Construction/Loadline
Issued 20 October 1989 Resolved
PLACE ON BOARD 5GPM HAND OPERATED BILGE PUMP.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Construction/Loadline
Issued 20 October 1989 Resolved
GRIND AND REWELD SEPARATED WELD ON #5 STARBOARD FRAME, 4.5' ABOVE DECK, FOREPEAK.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Construction/Loadline
Issued 20 October 1989 Resolved
REPAIR/REPLACE LADDER RUNGS IN #3 STARBOARD BALLAST TANK.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Engineering
Issued 18 October 1989 Resolved
DEMONSTRATE PROPER OPERATION OF VESSEL'S PORT MAIN ENGINE.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Fire Fighting
Issued 18 October 1989 Resolved
REPLACE B-I PORTABLE FIRE EXTINGUISHER IN GALLEY WITH B-II EXTINGUISHER.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Construction/Loadline
Issued 18 October 1989 Resolved
BACK GOUGE AND WELD MAIN DECK REPAIR IN WAY OF ENGINE ROOM, STBD SIDE.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Electrical
Issued 18 October 1989 Resolved
REMOVE DISCONNECTED WIRE FROM WHEELHOUSE LEADING TOPSIDE, PORT SIDE.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Electrical
Issued 18 October 1989 Resolved
REMOVE LOOSE WIRING LOCATED IN AFT STEERING STATION.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Navigation
Issued 18 October 1989 Resolved
DEMONSTRATE PROPER OPERATION OF VESSEL'S RADAR SYSTEM.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Navigation
Issued 18 October 1989 Resolved
REMOVE WATER FROM STEERING SPACE.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Navigation
Issued 18 October 1989 Resolved
INSTALL LOCKING DEVICES ON STARBOARD STEERING RAM ATTACHMENTS.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Navigation
Issued 18 October 1989 Resolved
REMOVE AND REPLACE AS ORIGINAL PORT STEERING RAM ANCHOR STANCHION.
Condition: Unknown
Due 18 October 1989
Resolved 18 October 1989
Documentation
Issued 13 October 1988 Resolved
PROVIDE EVIDENCE THAT VESSEL HAS A VALID FCC CERTIFICATE.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Electrical
Issued 13 October 1988 Resolved
REPAIR OR REPLACE MOTOR TO ANCHOR WINCH SUCH THAT IT IS FULLY OPERATIONAL.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Construction/Loadline
Issued 4 November 1986 Resolved
PRIOR TO THE VESSEL RETURNING TO SERVICE, CONDUCT A CREDIT DRYDOCK EXAM- INATION TO THE SATISFACTION OF THE COGNIZANT OFFICER-IN-CHARGE MARINE INSPECTION.
Condition: Unknown
Due 4 November 1986
Resolved 4 November 1986
Unknown
Issued 23 April 1984 Resolved
RENEW THE GLASS WINDOWS WHICH ARE BROKEN IN THE AFT CONTROL STATION AND THEAFT AND STARBOARD SIDES OF THE WHEELHOUSE.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Construction/Loadline
Issued 23 April 1984 Resolved
MAKE THE PORT WATERTIGHT DOOR CLOSURES OPERATIONAL.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Navigation
Issued 23 April 1984 Resolved
MAKE THE FATHOMETER OPERATIONAL PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Unknown
Issued 23 April 1984 Resolved
PROVIDE T-HANDLED WRENCHES AND A MOUNTING PLACE FOR THE SAME FOR THE MAIN DECK CLOSURES PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Unknown
Issued 23 April 1984 Resolved
TEST THE ANCHOR WINCH IN THE PRESENCE OF A MARINE INSPECTOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Unknown
Issued 23 April 1984 Resolved
REPAIR ACCOMMODATION SPACE DECK COVERING ON THE 02 DECK.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Electrical
Issued 23 April 1984 Resolved
MAKE ALL BUNK LIGHTS OPERATIONAL.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Unknown
Issued 23 April 1984 Resolved
MAKE THE PORT MAIN ENGINE LOW WATER ALARM OPERATIONAL.
Condition: Unknown
Due 25 May 1984
Resolved 23 April 1984
Unknown
Issued 23 April 1984 Resolved
PROVIDE A COVER FOR THE GENERATOR STARTING BATTERY PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Fire Fighting
Issued 23 April 1984 Resolved
PROVIDE SPANNER WRENCHES FOR ALL FIRE HOSE STATIONS PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Lifesaving
Issued 23 April 1984 Resolved
PROVIDE 40 SERVICEABLE LIFE PRESERVERS PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Lifesaving
Issued 23 April 1984 Resolved
PROVIDE TWO PADDLES FOR EACH LIFE FLOAT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Lifesaving
Issued 23 April 1984 Resolved
PROVIDE A SUITABLE RESCUE BOAT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Unknown
Issued 23 April 1984 Resolved
PROVIDE THE VESSEL WITH A SUITABLE ANCHOR PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984
Unknown
Issued 23 April 1984 Resolved
PROVIDE REACH ROD WRENCH FOR THE COLLISION BULKHEAD VALVE PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 23 April 1984
Resolved 23 April 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.