Inspection history · 17
11 December 2023
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7837623
15 May 2023
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7689176
20 January 2023
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7624517
6 September 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7552993
12 December 2021
Examination of Repairs · Administrative Inspection · Damage Survey · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7366791
8 February 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7137504
3 December 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7098385
17 November 2020
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7096690
15 July 2020
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7026723
20 November 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6859430
10 October 2019
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6831914
11 December 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6595597
15 November 2018
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6581451
5 October 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6282187
20 March 2017
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6108233
18 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5976658
5 July 2016
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5930751
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2022
Resolved
46 CFR 182.720 (e)
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Steering hoses are leaking hydraulic. Vessel shall install replacement hoses that meet SAE J-1942 to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2022
Resolution: Replaced steering hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 16 September 2022
Resolved
46 CFR 184.300
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessel was unable to lower anchor due to anchor binding up on the bow. Vessel shall enact repairs so crew can safely lower anchor to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2022
Resolution: Anchor is now operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2022
Resolved
46 CFR 182.100
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Low oil pressure alarm on port main engine is inoperable. Vessel shall enact repairs to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2022
Resolution: Alarm is now operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 September 2022
Resolved
46 CFR 180.137(d)(4)
Each survival craft required on For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. If the life float or buoyant apparatus does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line that, if synthetic, is of a dark color or is of a type certified to be resistant to deterioration from ultraviolet light. Segment of connection line between life float and painter line is degraded. Remove degraded line segment and splice painter line to life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 September 2022
Resolved
46 CFR 185.604(g)
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Paddles not marked with name of vessel. Mark paddles.
Action required: 10 - Deficiency Rectified
Resolved 16 September 2022
Resolution: Crew stenciled paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2022
Resolved
46 CFR 180.71(c)
Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.17. 04 lifejackets found with degraded reflective tape. Renew reflective tape.
Action required: 10 - Deficiency Rectified
Resolved 16 September 2022
Resolution: Renewed reflective tape.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 September 2022
Resolved
33 CFR 155.750(a)(2)(i)
The transfer procedures required by § 155.720 must contain, either in the order listed or by use of a cross-reference index page: A line diagram of the vessel's transfer piping, including the location of each valve, pump, control device, vent, and overflow. Marine Inspector observed that there wasn’t any line diagram of the vessel’s oil transfer system onboard or available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2022
Resolution: Crew created diagram.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 6 September 2022
Resolved
46 CFR 185.512(a)(1)
An emergency instruction placard containing the following information will satisfy the requirements of § 185.510. (a) Emergency instructions - (1) Rough weather at sea, crossing hazardous bars, or flooding. Marine Inspector observed that the Emergency Instructions onboard did not include instructions for Rough weather at sea, crossing hazardous bars, or flooding.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2022
Resolved 19 September 2022
Resolution: Provided adequate emergency instructions via email. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2022
Resolved
33 CFR 83.33(a)
A vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle. Bell not installed on vessel. Install bell.
33 CFR 83.33(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 September 2022
Resolution: Crew installed a bell.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 December 2021
Resolved
46 CFR 183.05-10
(1996)
If both of the required fixed power bilge pumps are electrically driven, two generators shall be provided.
The port generator is inoperable. Make repairs to the satisfaction of the Coast Guard prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 7 January 2022
Resolved 23 December 2021
Resolution: Vessel owner provided video evidence of satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 December 2021
Resolved
46 CFR 180.25-5
(1996)
All vessels shall be provided with an approved adult type life preserver for each person carried.
6 out of 40 required life preservers were found to be unserviceable. Destroy these 6 life preservers and place adequate replacements on board. Cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 December 2021
Resolution: Witnessed owner condemn bad life preservers and place adequate replacements on board.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 December 2021
Resolved
46 CFR 177.10-1(a)
(1995)
Compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel.
Vessel sustained damage that penetrated hull plating forward of the collision bulkhead as a result of a collision with a barge. Make permanent repairs to the satisfaction of the Coast Guard prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 December 2021
Resolution: Witnessed satifactory repairs and water test at 30 psi.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 February 2021
Resolved
A hatch exposed to the weather must be watertight except for a hatch on a watertight trunk that extends at least 12 inches above the weather deck.
STBD side engine room trunk was degraded such that the hatch would not properly seal allowing water to leak into the engine room. Repairs must be made to the trunk to allow the hatch to properly seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 26 March 2021
Resolution: Vessel owner installed new hatch assembly. MI verified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 December 2020
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. During a test of the emergency power supply for the emergency lighting system, Marine Inspectors observed that the port generator ammeter gauge was indicating a 50 AMPS draw, even though the vessel was utilizing emergency power. Effect repairs to the electrical system in order to demonstrate proper operation of the ammeter on the main switch board to the satisfaction of the attending Marine Inspectors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 December 2020
Resolved 16 December 2020
Resolution: MIs witnessed a sat. operational test of the port generator amp. meter.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 November 2019
Resolved
All firefighting equipment onboard must be in a serviceable condition and crew-members must be familiar with the use and location of firefighting equipment onboard. MIs observed crew-members were inadequately prepared to use the foam applicator on the main deck in a reasonable amount of time. Incorporate the maintenance and training in use of the foam applicator into the vessel’s maintenance and training plan respectively.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 December 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 November 2019
Resolved
Doors on cooking appliances must be provided with hinges and locking devices to prevent accidental opening in heavy seas. MIs observed oven in galley area did not have a locking device for the door as required by regulation. Install a locking device on the oven door to prevent accidential opening to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2019
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MIs discovered wire nuts were used for a splice in an electrical installation in vicinity of the port main engine. Place wire nuts within an enclosure to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 11 December 2018
Resolved
The person in charge of an oceangoing ship that cannot discharge oily mixtures into the sea in compliance with paragraphs (a), (b), (c) or (d) of this section must ensure that those oily mixtures are _
(1) Retained on board; or
(2) Discharged to a reception facility.
Inspections of the engine room discovered oily mixtures within a overboard discharge pump that was directly piped overboard with the overboard valve in the open position. Further inspection revealed oily mixtures in the pipe and at the outboard side of the overboard valve. Determine a plan of action to ensure oily mixtures are not pumped to the sea.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2019
Resolved 17 November 2020
Resolution: O/O welded a box under the shaft seal so that water will not mix with bilge water/oil.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2018
Resolved
Ground detection meter inoperable. Unable to prove proper operation of the gauge.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 28 February 2019
Resolution: Witnessed installation and operation of LED style active ground dection sensor added to main switchboard. Def cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 November 2018
Resolved
Visual Distress Signals (flares) expired October 2018
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 18 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 November 2018
Resolved
Smoke detector/alarms inoperable in passenger berthing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2018
Resolved 18 January 2019
Lifesaving › Lifefloat › Netting
Issued 27 September 2017
Resolved
02 - 12 person Life Float's have netting that needs replacement. 46 CFR 180.200. Vessel has been ordered to reduce passenger count by 24 until corrected and 835 is cleared.
Action required: 705 - Other - as specified
Resolved 5 October 2017
Resolution: Lifefloats have been replaced with 15 person lifefloats, all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 September 2017
Resolved
Licensees of radio stations are required to have current station documents. Bridge to Bridge Act Safety Certificate // Communications Act Safety Certificate 47 CFR 80.401
Due 14 October 2017
Resolved 5 October 2017
Resolution: FCC documents are up to date with current call sign and have been tested for the current equipment onboard.
Fire Fighting › Portable Foam Applicators › General
Issued 20 March 2017
Resolved
VSL has an endorsement to carry hazardous materials but does not have the required fire protection requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2017
Resolution: Verified additional FF equipment for the carriage of hazmat. All sat.
Lifesaving › Lifefloat › Float Free
Issued 5 July 2016
Resolved
Life Float not stowed in a manner to allow equipment to float unobstructed.
Due 5 July 2016
Resolved 5 July 2016
Resolution: corrected on the spot
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 5 July 2016
Resolved
Emergency spot is not functioning for the port MDE.
Action required: 705 - Other - as specified
Due 10 July 2016
Resolved 27 September 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 July 2016
Resolved
No emergency lights exists along the line of escape from the lower berthing space to the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 18 August 2016
Resolution: Vessel rep corrected emergency lighting def.