Records from 1982 to 1999. Most recent: inspection, 27 April 1999.
Inspection history · 44
27 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791457
4 June 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453486
30 December 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786587
3 December 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778532
3 December 1997
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409794
29 November 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 216361
15 April 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441243
7 January 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 768606
30 December 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 202006
8 August 1996
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093013
6 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23663
6 June 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404175
26 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 692484
6 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 656138
7 June 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438338
6 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 195521
5 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214559
13 July 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 692485
16 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 85513
24 May 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400038
6 January 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366964
25 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 467276
13 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 501431
1 April 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359517
23 July 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471634
19 June 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425270
24 December 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957914
19 December 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953009
20 May 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1211704
15 May 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 917598
30 April 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905683
19 April 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237786
18 May 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043481
26 May 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887613
5 February 1988
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1017962
3 April 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004382
20 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1021563
17 December 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337438
18 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985124
27 March 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999600
27 March 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295059
20 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979247
14 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974137
2 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271225
Construction/Loadline
Issued 4 June 1998
No resolution recorded
MAKE PERMANENT REPAIRS TO AFTER PORT BULKHEAD IN ENGINE ROOM OUTBOARD EDGE AT NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 31 January 1999 — due date passed with no resolution recorded
Documentation
Issued 4 June 1998
No resolution recorded
PROVIDE ONBOARD THE ORIGINAL CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 4 July 1998 — due date passed with no resolution recorded
Construction/Loadline
Issued 3 December 1997
Resolved
PROVE PROPER OPERATION OF GALLEY ENTRANCE WATERTIGHT DOOR.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 3 December 1997
Resolved
Provide an approved first aid kit, ensure kit is complete and Coast Guard approved.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Deck/Cargo
Issued 3 December 1997
Resolved
INSTALL MISSING VENT HEAD FOR STBD STERN BALLAST TANK.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Construction/Loadline
Issued 3 December 1997
Resolved
REPAIR CRACKS AND EVALUATE DAMAGE TO STBD DECK BULWARKS.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Construction/Loadline
Issued 3 December 1997
Resolved
REPLACE OR REPAIR STARBOARD BITTS AFT OF HOUSE.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Construction/Loadline
Issued 3 December 1997
Resolved
GOUGE AND REWELD DECK ON BASE OF PORT QUARTER BITTS.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Accommodation/Occupational Safety
Issued 3 December 1997
Resolved
REPAIR OR REPLACE PORTSIDE RAILING IN WAY OF CRACKS, WASTAGE.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 3 December 1997
Resolved
PROVIDE EXHAUST LAGGING PME INBOARD.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 3 December 1997
Resolved
STENCIL EMERGENCY EXIT PROPERLY FOR ENGINEROOM ESCAPE TRUNK.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 3 December 1997
Resolved
PROVIDE GUARD FOR FRONT OF STARBOARD MAIN ENGINE.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 3 December 1997
Resolved
INSTALL METAL WIRE TIES IN GALLEY/BRIDGE OVERHEAD ELECTRICAL WIRE RUNS.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Engineering
Issued 3 December 1997
Resolved
REPLACE SCREENS AS NEEDED IN DECK VENT HEADS (5 & 6).
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Engineering
Issued 3 December 1997
Resolved
PROVIDE CAP TO SECURE FUEL TANK DRAIN IN ENGINEROOM PORTSIDE FWD.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 3 December 1997
Resolved
REMOVE ALL TOOLS AND MATERIALS FROM SWITCHBOARD IN ENGINEROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 3 December 1997
Resolved
INSTALL SWITCHBOARD SLIDING BAR TO PREVENT BOTH GENERATORS FROM RUNNING AT THE SIMULTANEOUSLY.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 3 December 1997
Resolved
INSTALL BLANKS IN SWITCHBOARD AS NECESSARY AND LABEL ALL POWER PANELS PROPERLY AND STOVE DISCONNECT.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 3 December 1997
Resolved
SECURE LOOSE ELECTRICAL WIRING ON PORT MAIN ENGINE.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Accommodation/Occupational Safety
Issued 3 December 1997
Resolved
REPAIR OR REPLACE LADDER TO LIFEBOAT DECK.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Deck/Cargo
Issued 3 December 1997
Resolved
PROVIDE CONTAINMENT PLUG FOR FUEL TRANSFER MANIFOLD ON DECK AND INSTALL CONTAINMENT ON FILL AND DISCHARGE CONNECTIONS ON DECK.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Engineering
Issued 3 December 1997
Resolved
INSTALL OVERSPEED TRIPS ON BOTH MAIN DIESEL ENGINES AND OPERATIONALLY TEST TRIPS WITH HAND TACH OR INSTALLED RPM GAUGE. ALSO, TEST BOTH GENERATORS WITH HAND TACH OR INSTALLED RPM GAUGE.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Documentation
Issued 3 December 1997
Resolved
DRAFT AND SUDMIT TO LOCAL OCMI FOR APPROVAL A FIRE AND SAFETY PLAN.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Documentation
Issued 3 December 1997
Resolved
PROVIDE ALL REQUIRED NAV PUBS, CHARTS AND TIDE TABLES.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Lifesaving
Issued 3 December 1997
Resolved
PROPERLY MOUNT/SECURE WATER HEATER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Construction/Loadline
Issued 3 December 1997
Resolved
GOUGE AND WELD SOFT PATCH AREA CUT IN ENGINEROOM OVERHEAD AND RENEW SOUND TUBE/STAND PIPE BROKEN IN AFT STEERING STATION.
Condition: Unknown
Due 3 December 1997
Resolved 3 December 1997
Electrical
Issued 19 June 1992
Resolved
INSTALL PROTECTIVE BLANK COVERS IN ELECTRICAL BOX LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 19 June 1992
Resolved 19 June 1992
Navigation
Issued 19 June 1992
Resolved
INSTALL RUDDER ANGLE INDICATOR
Condition: Unknown
Due 19 June 1992
Resolved 19 June 1992
Documentation
Issued 19 December 1991
Resolved
VESSEL IS RESTRICTED TO 1000 FT. OF LAND UNTIL SUCH TIME AS VHF-FM, SSB RADIO AND RADAR ARE PROVEN TO BE OPERATIONAL. ONLY CREWMEMBERS WITH A VALID FCC OPERATORS PERMIT ARE AUTHORIZED TO OPERATE ABOVE LISTED EQUIPMENT.
Condition: Unknown
Due 19 December 1991
Resolved 19 December 1991
Lifesaving
Issued 15 May 1991
Resolved
PLACE A SUITABLE RESCUE BOAT/PLATFORM ON BOARD SUBJECT VESSEL.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Engineering
Issued 15 May 1991
Resolved
REPLACE HOLDING PIN IN THROTTLE CLUTCH LINKAGE, MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Navigation
Issued 15 May 1991
Resolved
REPAIR VESSEL'S TRANSDUCER DURING NEXT DRYDOCK, USE ALTERNATE MEANS FOR SOUNDING UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Accommodation/Occupational Safety
Issued 15 May 1991
Resolved
REPLACE PSI GAUGE ON AFT PRESSURE VESSEL
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Engineering
Issued 15 May 1991
Resolved
REPAIR OR REPLACE RPM GAUGES ON BRIDGE AND ENGINE ROOM.
Condition: Unknown
Due 15 May 1991
Resolved 15 May 1991
Electrical
Issued 19 April 1990
Resolved
REPAIR EMERGENCY LIGHT IN WHEEL HOUSE.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 19 April 1990
Resolved
HAVE ON BOARD AN UPDATED COAST PILOT NO. 5 AS REQUIRED BY 46 CFR 97.05-5.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Accommodation/Occupational Safety
Issued 19 April 1990
Resolved
LABEL RANGE DISCONNECT IN GALLEY.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Accommodation/Occupational Safety
Issued 19 April 1990
Resolved
REPAIR ELECRIC RANGE CONTROL LIGHT, VENTILATION FAN, AND CONTROL KNOB IN GALLEY. VENTILATION FROM FAN MUST BE VENTED TO A MAIN DECK AREA.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 19 April 1990
Resolved
REPAIR SOUND POWERED TELEPHONE SYSTEM SIGNAL DEVICE IN ENGINE ROOM.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 19 April 1990
Resolved
REPLACE STBD RUNNING LIGHT LIGHTBULB WITH PROPER LIGHTBULB TO BRING FOCUS OF LIGHT TO THE CENTER OF RUNNING LIGHT.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 19 April 1990
Resolved
REPAIR RUDDER ANGLE INDICATOR IN WHEELHOUSE AND AFT CONTROL STATION.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Fire Fighting
Issued 19 April 1990
Resolved
INSTALL AN APPROVED MOUNTING BRACKET FOR FIRE EXTINGUISHER IN GALLEY.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 27 March 1986
Resolved
NAV LIGHTS.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Unknown
Issued 27 March 1986
Resolved
FUEL OIL TRANSFER PROCEDURE.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Navigation
Issued 27 March 1986
Resolved
RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Unknown
Issued 27 March 1986
Resolved
REPLACE ALL NAV LIGHT BULBS WITH THE CORRECT TYPE FOR EACH LIGHT FIXTURE.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Unknown
Issued 27 March 1986
Resolved
PROVIDE A CORRECT FUEL OIL TRANSFER PROCEDURE AS REQUIRED BY 33 CFR 155.720. USE 155.720 AS A GUIDE.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986
Unknown
Issued 27 March 1986
Resolved
INSTALL RUDDER ANGLE INDICATORS AT BOTH STEERING STATIONS AS PER 46 CFR 113.40.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986