11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 30 September 2019
Resolved
Messenger line not proper material or length for line-throwing apparatus on board
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 October 2019
Resolution: Proper messenger line on board
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2018
Resolution: A new hydrostatic release was installed prior to departing Cameron, LA
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2018
Resolved
03 LIFE JACKET LIGHTS EXPIRED OR MISSING.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2018
Resolution: Additional lights were purchased and placed on respective lifejackets
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 10 October 2018
Resolved
LINE THROWING GUN DOES NOT HAVE REQUIRED LENGTH NOR TYPE OF AUXILLARY LINE. VESSEL HAS 600 FEET OF YELLOW SYNTHETIC.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 October 2018
Resolved
PORT AND STARBOARD AFT BALLAST TANKS (#3) LEAKING INTO THE STEERING GEAR ROOM BETWEEN TANKS DUE TO WASTAGE. MARKED BY MARINE INSPECTOR. MAKE TANKS AVAILABLE FOR MORE IN-DEPTH AND INTERNAL INSPECTION.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018
Resolved
BILGE ALARM SYSTEM INSTALLED BUT WILL NOT ACTIVATE ON BRIDGE.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 October 2018
Resolved
EMERGENCY LIGHTING ON 02 DECK STAIRWELL LEADING TO PILOTHOUSE IS INOPERATIVE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018
Resolved
PORT STEERING RAM IS LEAKING HYDRAULIC FLUID FROM RAM SEAL.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018
Resolved
NUMEROUS EXPOSED WIRING UNDER PILOTHOUSE CONSOLE MUST BE PROPERLY TERMINATED OR REMOVED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018
Resolved
PORT SHIP SERVICE DIESEL GENERATOR IS NOT PROPERLY MARKED. MISSING POWER RATING TAG FOR 50DEGREES CELSIUS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 October 2018
Resolved
ELECTRICAL BOXES LOCATED NEAR THE PORT SIDE MAIN ENGINE REDUCTION GEAR UNDER THE STEERING RESERVOIR AND THE ENGINE ROOM FIRE PUMP MOTOR CONTROLLER ARE NOT ADEQUATELY SECURED OR FASTENED. BOXES AND/OR MOUNTS ARE SIGNIFICANTLY WASTED.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 10 October 2018
Resolved
CURRENT GARBAGE MANAGEMENT PLAN ALLOWS FOR WASTE TO BE DESPOSED WHEN OUTSIDE 12 MILES. PLAN IS OUTDATED AND NOT KEEPING WITH CURRENT REGULATIONS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 October 2018
Resolved
LIFEBUOY STORAGE LOCATIONS NEED TO BGE MARKED WITH "LIFE BUOY" OR THE APPROPRIATE IMO SYMBOL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 October 2018
Resolved
VESSEL HAS MORE THAN ONE TYPE/SIZE PORTABLE FIRE EXTINQUISHER. NEED TO BE MARKED WITH THE CORRESPONDING STATION NUMBER.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2018
Resolved 24 January 2024
Resolution: Vessel ceased operations and was laid up in 2020 and shifted from USA flag to foreign flag in January 2024.
Engineering › Fuel Oil Service System › Valve
Issued 19 July 2016
Resolved
Witnessed valve on fuel oil manifold leaking under pressure and leaking fuel line on starboard generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2016
Resolution: Valve was replaced, witnessed sat operation of fuel transfer manifold.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 July 2016
Resolved
GAsket on forward engine room door found wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2016
Resolution: Crew replaced gasket prior to conclusion of inspection.
Communications › Alarms/Indicators › General Alarm
Issued 19 July 2016
Resolved
General alarm did not function under emergency power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2016
Resolution: Replaced battery, witnessed proper operation of GA on emergency power.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 July 2016
Resolved
Emergency light on 01 level staircase to maindeck did not function upon loss of power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2016
Resolution: Replaced light, ligth sat.
Lifesaving › Lifefloat › Paddle
Issued 19 July 2016
Resolved
Three paddles found unservicable due to UV damage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2016
Resolution: Replaced paddles, all sat.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 19 July 2016
Resolved
Packing glands found leaking excessively. Leak not to the extent necessitating a no sail.
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 20 July 2016
Resolution: Tightened packing gland, all sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 July 2016
Resolved
Remove hold back devices on all water tight doors.
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 20 July 2016
Resolution: All hold back devices were removed.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 19 July 2016
Resolved
1.5 inch pipe with cam lock fitting found on overboard discharge piping outboard of shutoff valve. Provide permanent cap for pipe.
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 20 July 2016
Resolution: Capped off piping suction.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 July 2016
Resolved
Adjust aft engine room water tight door to allow proper closing of watertight door.
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 20 July 2016
Resolution: Door closes under its own power, all sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 July 2016
Resolved
Label weaterdeck fuel shut off fittings for identification and direction of operation.
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 20 July 2016
Resolution: Both fittings were labeled correctly.
Stability › Weathertight Integrity › General
Issued 19 July 2016
Resolved
Replace gasket on mushroom vent on 01 level weaterdeck.
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 20 July 2016
Resolution: Gasket was renewed, all sat.
Stability › Weathertight Integrity › General
Issued 19 July 2016
Resolved
Repair wasted flange at bottom of door frame.
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 20 July 2016
Resolution: New combing was welded in place, all sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 July 2016
Resolved
Replace junction box cover for A/C system air handler power supply.
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 20 July 2016
Resolution: Added cover to the junction box.