MAURY USCG vessel records Sign in
← All vessels

MISS LINDA LEE

MISS LINDA LEE is a 2008 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2008, most recently in July 2023, along with 44 deficiencies and 1 operational control.

Records from 2008 to 2023. Most recent: inspection, 27 July 2023.

Built
2008
Last inspected
27 July 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9556222 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE5415
883137
Flag
UNITED STATES
367366390
Maury page id
psix-883137

Inspections, by type

…with no type recorded4
Years with a record 12 calendar years (2008–2023)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
97 - Convention (Subpart B), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
325 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE5415MMSI 367366390 · active · compulsorily equipped · granted 5 June 2018, expires 2 July 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LUCAS JOHN Offshore Supply Vessel · MISLE 244505 · 8 December 2010 · activity 3907166LUCAS JOHN Offshore Supply Vessel · MISLE 244505 · 1 November 2010 · activity 3883403

Inspection history · 28

27 July 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7753463
11 January 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7619459
16 November 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7351769
13 October 2021 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7331900
22 September 2021 In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7317623
6 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6851156
2 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6849652
15 October 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6846401
2 October 2019 Deficiency Check · Annual Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6826701
19 July 2018 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6484165
10 July 2018 Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6472653
10 April 2018 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6389165
28 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6363434
18 September 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6269163
13 July 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5939784
6 July 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5932017
18 August 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5220122
12 July 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4376827
10 July 2012 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4373663
17 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4118641
8 December 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3907166
3 December 2010 Type not recorded
No type recorded · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 3903622
1 November 2010 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3883403
10 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3693144
13 July 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3530281
9 December 2008 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3393422
31 July 2008 Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3284940
8 January 2008 Initial Certification · Construction Oversight · Inclining Experiment
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3269722

Deficiency record · 44

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 January 2023 Resolved
Fuel lines must be protected from excessive vibration/mechanical injury. Port generator fuel line needs chaffing gear and a renewed clip. Replace fuel line. -46 CFR 182.455(b)(3) - 50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 31 August 2023
Resolution: Vsl has been reflagged.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 January 2023 Resolved
Vessel must have an interconnected fire detection system installed in all enclosed areas where passengers & crew have routine access, to include accommodation spaces & machinery spaces. Vessel will need to replace modular detectors with an interconnected system within required spaces. – 46 CFR 181.405(c)- 50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 31 August 2023
Resolution: Vsl has been reflagged.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 January 2023 Resolved
The discharge ends of fuel tank vent pipes must be fitted with flame screens. Both port & starboard fuel vents are missing screens or have holes in them. Replace. - 46 CFR 182.450(c)- 50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 2 February 2023
Resolution: Flame screens replaced/renewed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 January 2023 Resolved
Fuel filter & strainer bowls must be highly resistant to shattering due to mechanical impact. Bow thruster/ standby (fire monitor engine) was missing resistant bowl. - 46 CFR 182.182.455(b)(6) – 10(c)
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 11 January 2023
Resolution: The resistant bowl was added to the satisfaction of the lead Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 January 2023 Resolved
Standby vessels must have at least a fire monitor with a minimum flow rate of 500gpm. The fire monitor is currently inoperable. Monitor must be operable prior to operating as a standby vessel. – 33 CFR 143.405 – 705(c)
Action required: 705 - Other - as specified
Due 11 January 2023
Resolved 31 August 2023
Resolution: Vsl has been reflagged
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 October 2021 Resolved
Standby vessel must have fire monitor w/ a minimum flow rate of at least 500 gallons per minute. Vsl fire monitor inop unable to act as stand by vsl until repaired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 23 October 2021
Resolution: Provided photographic evidence of fire monitor working.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 2 October 2019 Resolved
Remove stop valves from between the pressure vessel and pressure refief valve on both air compressors in the generator room.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Verified proper installation of pressure relief valves and stop valves on both air compressors in the generator room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 October 2019 Resolved
Clean and identify source of excessive oil leakage from port and stbd generator vents which is then collecting on port side mechanical ventilation duct.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Received photo showing excessive oil leakage from port and stbd generator vents and port side mechanical ventilation duct was thoroughly cleaned.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 October 2019 Resolved
Repair hydraulic leak in steering system which is causing hydraulic oil to accumulate on top of port and stbd hydraulic oil tanks.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Verified hydraulic leak repaired and excess oil on top of tanks cleaned.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 2 October 2019 Resolved
Rudder angle indicator was indicating between 7-8 degrees when the rudder of the vessel was at midships.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2019
Resolution: Received photo from vessel captain showing true readings on both rudder angle indicators.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 2 October 2019 Resolved
Ground tackle/anchor chain used for making up the anchor line and anchor were seized together.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Verified ground tackle/anchor chain used for making up the anchor line and anchor were no longer seized together.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 2 October 2019 Resolved
Ground tackle/anchor chain used for making up the anchor line and anchor were seized together.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 October 2019
Resolution: Verified ground tackle/anchor chain used for making up the anchor line and anchor were no longer seized together.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 2 October 2019 Resolved
Emergency instructions placard had duties for crewmember positions that did not exist onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2019
Resolution: Received photo from vessel captain showing emergency instructions placard for current crewmember positions onboard.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 2 October 2019 Resolved
Emergency broadcast instructions did not have name of vessel inserted in instructions.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 3 October 2019
Resolution: Verified name of vessel inserted in instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 October 2019 Resolved
Life floats were stowed in a tier of three without having spacers between them.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Received photo showing life floats stowed in a tier of three with spacers between them.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 October 2019 Resolved
Missing Ship's Medicine Chest and Medical Aid at Sea publication as required by vessel standby endorsement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 November 2019
Resolution: Received photo from vessel captain showing International Medical Guide for Ships publication.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 July 2018 Resolved
IAW 46CFR181.3 THIS VSL IS REQUIRED TO HAVE AN INSTALLED FIRE PUMP THAT MAINTAINS AT LEAST 60 PSI. THE PUMP CURRENTLY INSTALLED COULD NOT BE ENERGERIZED DUE TO AN ELECTRICAL ISSUE. AFTER ELECTRICAL REPAIR THE FIRE PUMP FREQUENTLY LOST ITS PRIME CAUSING A FLUCTUATION OF PRESSURE BETWEEN 60 PSI AND 10 PSI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 July 2018 Resolved
Fire Alarm panel was inoperative. IAW 46 CFR 181.405 (a) this vessel is required to maintain an operative trouble and fire alarm detection panel.
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 30 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018 Resolved
#4 MDE was inoperable upon arrival. IAW 46 CFR 182.2(a) all installed propulsion machinery shall operate as intended.
Action required: 10 - Deficiency Rectified
Resolved 30 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2018 Resolved
#3 and #4 MDE F/O Supply hoses were severely worn and had the steel mesh layer exposed posing a major risk for a F/O leak during engine operation. Fuel lines shall be maintained IAW SAE J-1942.
Action required: 10 - Deficiency Rectified
Resolved 30 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 July 2018 Resolved
46 CFR 183.33(c)(f) requires non conductive matting to be placed infront of electrical switchboards. Upon inspection no electrical safety matting was present.
Action required: 10 - Deficiency Rectified
Resolved 30 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2018 Resolved
Upon inspection it was found the fire monitor system which is a carriage requirement for their standby vessel endorsement to be inoperable IAW 33 CFR 143.405(E)(12) the fire monitor is a condition of the endorsment.
Action required: 705 - Other - as specified
Resolved 30 August 2018
Resolution: The vessel rep must provide photo evidence of an operational fire monitor in order for the vessel to conduct standby vessel operations.
Fire Fighting › Nozzles › Condition
Issued 18 September 2017 Resolved
Fire monitor required for standby vessel service was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 19 September 2017
Resolution: Fire monitor repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 September 2017 Resolved
Vessel missing publication "The Ships Medicine Chest" required for standby vessel service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 19 September 2017
Resolution: publication, "The Ships Medicine Chest" place onboard vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 September 2017 Resolved
Vessel missing industrial sized first aid kit required for standby vessel service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 19 September 2017
Resolution: Industrial sized first aid kit place onboard vessel.
Engineering › Reduction Gearing/Clutches › Gear
Issued 18 September 2017 Resolved
#3 Rduction gear inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 19 September 2017
Resolution: #3 Reduction gear repaired.
Fire Fighting › Fire Pumps › Power Source
Issued 13 July 2016 Resolved
VESSEL'S REQUIRED TO HAVE FIRE PUMP CAPABLE OF PRODUCING 60 PSI. VESSEL'S FIRE PUMP IS CURRENTLY INOPPERABLE. CONDUCT SATISFACTORY TEST OF FIRE PUMP IN PRESENCE OF ATTENDING MI.
Action required: 705 - Other - as specified
Resolved 14 July 2016
Resolution: CIV Manning attended vessl and confirmed proper repairs and operation of fire pump. DEF Cleared.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 18 August 2015 Resolved
Replace Chem light on 01 lifejacket.
Action required: 705 - Other - as specified
Due 25 August 2015
Resolved 19 August 2015
Resolution: Verified new chem light.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 August 2015 Resolved
Remove extension cords and power strips throughout vessel.
Action required: 705 - Other - as specified
Due 25 August 2015
Resolved 19 August 2015
Resolution: Verified removal of extension cords and power strips.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 18 August 2015 Resolved
Repair STBD rudder angle indicator.
Action required: 705 - Other - as specified
Due 1 September 2015
Resolved 28 August 2015
Resolution: Verified repair of the rudder angle indicator.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 August 2015 Resolved
Repair/remove wiring under aft steering station.
Action required: 705 - Other - as specified
Due 25 August 2015
Resolved 19 August 2015
Resolution: Verified wiring under aft station was removed.
Documentation › Markings/Placards › Garbage Placard
Issued 18 August 2015 Resolved
Update MARPOL 5 placard.
Action required: 705 - Other - as specified
Due 25 August 2015
Resolved 19 August 2015
Resolution: Verified new MARPOL placards had been posted.
Stability › Watertight Integrity › General
Issued 18 August 2015 Resolved
Recaulk WT bulkhead penetrations into engine room. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2015
Resolution: Verified recaulking of WT bulkhead penetrations.
Fire Fighting › Fire Pumps › Pressure
Issued 18 August 2015 Resolved
Prove proper operation of fire pump. (Prior to sail)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2015
Resolution: Verified proper operation of fire pump.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 July 2012 Resolved
Vessel missing fuel transfer procedures. Vessel shall supply copy onboard to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 July 2012
Resolved 25 July 2012
Resolution: Vessel submitted copy of fuel transfer procedures. All sat.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 12 July 2012 Resolved
Vessel missing EPA NOI. Vessel shall supply copy onboard to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 July 2012
Resolved 24 July 2012
Resolution: Vessel representative provided copy of NOI.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 July 2012 Resolved
Vessel alcohol test strips expired. Vessel shall supply new set onboard to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 July 2012
Resolved 24 July 2012
Resolution: Vessel purchased new alcohol test strips and submitted proof of receipt.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 12 July 2012 Resolved
Steering system in Fail Safe mode, on Stbd. steering pump, rudder angle indicators not in synch. Vessel shall repair to original condition to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 20 July 2012
Resolved 13 July 2012
Resolution: Vessel representative provided receipt for third party repairs to rudder angle indicator. Rudder angle indicators are both in synch.
Engineering › Fuel Oil Service System › Pump
Issued 12 July 2012 Resolved
Stbd. Generator fuel pump in process of repair by cummins tech. Vessel shall supply 3rd party receipt of repairs.
Action required: 705 - Other - as specified
Due 14 July 2012
Resolved 13 July 2012
Resolution: Received from vessel representative copy of 3rd party receipt of repairs. All sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 December 2008 Resolved
Demonstrate proper operation of bilge alarm system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2008
Stability › Watertight Integrity › General
Issued 9 December 2008 Resolved
Demonstrate proper operation door closure alarm, Alarm switches were tied in the door close postion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 December 2008 Resolved
demonstrate proper operation of Bilge alarms system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 July 2008 Resolved
Make final revisions to Fire/Safety Plan per SECTOR Mobile comments. Owner/operator has requested stamped "Approved" vice "Examined" plan for insurance reasons.
Action required: 705 - Other - as specified
Due 21 August 2008
Resolved 5 August 2009
Resolution: Received copy of letter dated 8/5/08 stating that safety plan has been reviewed and returned marked "Approved."
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 July 2008 Resolved
Provide a suitable and approved "Rescue Swimmer Harness/Line". 46CFR185.512 and 46CFR180.210(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2009
Resolution: Witnessed sat harness and line.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.