MAURY USCG vessel records
← All vessels

SAN CLEMENTE ISL

Built
1982
Last inspected
24 July 2019
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 24 July 2019
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 26 calendar years (1982–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
2325 - Regulatory (Subpart C or D), Gross Ton 2325 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-53788
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

MIKIONA Towing Vessel · MISLE 146074 · 3 August 2006 · activity 2735151

Inspection history · 53

24 July 2019 Administrative Inspection · Internal Structural Exam · Load Line/Change of Employment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6763073
30 March 2009 Load Line/Change of Employment
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3439135
20 November 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3101815
12 July 2007 Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3051644
26 June 2007 Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2986043
18 June 2007 MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2966188
3 August 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2735151
13 April 2006 COI Inspection · MARPOL Annex I Examination · MTSA Verification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2613751
11 August 2005 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2459501
22 July 2005 Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2435669
3 February 2005 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2285847
20 July 2002 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1632895
1 May 2001 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373450
11 May 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381889
7 May 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1456691
6 May 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213602
29 June 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 796407
1 June 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1442720
19 June 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1460099
14 April 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1452274
29 April 1996 Re-Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355906
3 July 1995 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 881385
18 April 1995 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355184
24 June 1994 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1470391
5 January 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 23023
20 July 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 40108
20 July 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 92097
19 April 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 841885
2 July 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1428146
16 June 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 959890
1 June 1992 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 962626
14 May 1992 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1354150
8 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1268649
1 May 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1254575
22 July 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1251616
21 May 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 916851
13 May 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1241250
29 April 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 899396
22 April 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1239951
30 April 1990 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1233870
22 September 1989 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 898891
21 August 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 889938
25 July 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035050
3 May 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1194952
3 June 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198857
14 April 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206400
5 May 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019862
24 March 1987 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1325722
12 June 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999139
25 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985890
23 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280379
11 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972040
18 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281659

Deficiency record · 42

Documentation › Safety/Response Plans/Programs › SOPEP
Issued 13 April 2006 Resolved
Provide current SOPEP approval letter
Due 30 April 2006
Resolved 17 April 2006
Resolution: Received updated letter dated 11FEB05 expires 10MAR10
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 13 April 2006 Resolved
Update SOPEP QI roster (last 2002)
Due 30 April 2006
Resolved 17 April 2006
Resolution: Received updated roster dated 14FEB06
Construction/Loadline › Structures › Deck Plating
Issued 22 July 2005 Resolved
Crop and renew, back to good metal, wasted deck on fwd center rake. Provide scope of work. There was a 8 inch diamter wasted area that had holes in deck. Sunlight could be seen from within rake under deckplate. Steve said he would get UT shots back to good metal.
Due 1 September 2005
Resolved 11 August 2005
Resolution: 22 x 22 radiused steel inserted.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 July 2005 Resolved
Crop and renew all void ladder rungs that have wasted more than 25% of original thickness.
Due 1 September 2005
Resolved 11 August 2005
Construction/Loadline › Penetrations › Gasket
Issued 22 July 2005 Resolved
Remove water from 3 & 4 port wing, 2-5 stbd wing and make hatches watertight.
Due 1 September 2005
Resolved 11 August 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 February 2005 Resolved
Operated vessel without valid COI. Third and fourth annual were not conducted.
Due 3 February 2005
Resolved 3 February 2005
Resolution: Conducted COI inspection.
Engineering › Fuel Oil Service System › Valve
Issued 3 February 2005 Resolved
Repair/Renew leaking fuel oil valve on fuel tank.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Engineering › Fuel Oil Service System › Piping
Issued 3 February 2005 Resolved
IAW 46CFR56.50-75 cap fuel tank drain valve after valve.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 3 February 2005 Resolved
Prove proper operation of ship service deisel generator. Company is removing old generator and installing new.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Resolution: New Magna Plus synchronous AC Generator model # 363PSL1607, 1800 RMP, 109 KW, 240V, 327A, and 6.8L John Deere engine model PE6068TF250 installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 February 2005 Resolved
IAW 46CFR111.15-5 install battery covers.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 February 2005 Resolved
Provide insulation on generator exhaust piping.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 3 February 2005 Resolved
Steel grating on top of generator room is wasted. Completely remove or install new steel plate.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 7 April 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 February 2005 Resolved
COI improperly scheduled for ISE 1 in 5 years. Conduct an internal structural exam in accordance with table 91.40-3(a) 46CFR.
Action required: 705 - Other - as specified
Due 7 April 2005
Resolved 22 August 2005
Resolution: Completed ISE.
Lifesaving
Issued 1 June 1998 Resolved
REMOVE PAINT FROM STORAGE LOCKER OR PROVIDE PROPER STORAGE.
Condition: Unknown
Due 1 June 1998
Resolved 1 June 1998
Electrical
Issued 18 April 1995 Resolved
Remove all dead end wires and wire nuts in the machinery space.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 18 April 1995 Resolved
Renew wasted hatch covers and provide retension chain/line for each.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Fire Fighting
Issued 18 April 1995 Resolved
Service or remove two portable fire extinguishers from flammable liquid storage area.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Electrical
Issued 18 April 1995 Resolved
Remove all temporary wiring (portable extension cords) and install wires inaccordance with the Subchapter J requirements.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Electrical
Issued 18 April 1995 Resolved
Provide rubber mat in front of electrical panel.
Condition: Unknown
Due 18 April 1995
Resolved 18 April 1995
Construction/Loadline
Issued 24 June 1994 Resolved
RENEW THE HATCH COVER FOR THE PORT FORWARD RAKE.
Condition: Unknown
Due 25 July 1994
Resolved 5 July 1994
Engineering
Issued 24 June 1994 Resolved
PROVIDE A GUARD FOR THE SIGHT GLASS ON THE GENERATOR DAY TANK.
Condition: Unknown
Due 25 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 24 June 1994 Resolved
PROVIDE A RETENTION DEVICE FOR ALL HATCH COVERS.
Condition: Unknown
Due 25 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 16 June 1992 Resolved
CROP OUT AND RENEW TWO FLAT BAR (APPROXIMATELY 8" X 28" X 3/8") BETWEEN FRAMES #3 AND 4 IN TWO PLACES IN WAY OF FORWARD STARBOARD RAKE.
Condition: Unknown
Due 17 July 1992
Resolved 2 July 1992
Construction/Loadline
Issued 16 June 1992 Resolved
CROP OUT AND RENEW DEEP WEB FRAME #6 THREE FEET FROM THE SIDE SHELL IN WAY OF #1 STARBOARD VOID.
Condition: Unknown
Due 17 July 1992
Resolved 2 July 1992
Construction/Loadline
Issued 16 June 1992 Resolved
CROP UP AND RENEW 3 FLAT BARS (APPROXIMATELY 8" X 28" X 3/8") BETWEEN FRAMES #3 & 4 IN WAY OF FORWARD STARBOARD RAKE.
Condition: Unknown
Due 17 July 1992
Resolved 2 July 1992
Construction/Loadline
Issued 16 June 1992 Resolved
PICK UP WELD IN WAY OF AFT STERN RAKE DEEP WEB TO BOTTOM PLATE THIRD LONGITUDINAL FROM THE CENTER LINE.
Condition: Unknown
Due 17 July 1992
Resolved 2 July 1992
Lifesaving
Issued 1 May 1992 Resolved
PLACE VESSEL NAME ON RING BUOYS.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Construction/Loadline
Issued 1 May 1992 Resolved
RENEW DECK OPENING GASKETS AT #3 CENTER, #4 CENTER, #5 CENTER AND AFT RAKE CENTER.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Construction/Loadline
Issued 1 May 1992 Resolved
INSTALL CAPTURE CHAIN FOR DECK OPENINGS AT BOW RAKE CENTER AND #2 STARBOARDCOMPARTMENTS.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Documentation
Issued 13 May 1991 Resolved
COMPLETE ALL REQUIREMENTS REQUIRED BY THE U.S. COAST GUARD MARINE SAFETY CENTER FOR THE ISSUANCE OF A NEW STABILITY LETTER WHICH WILL ALLOW THE CARRIAGE OF POTABLE FRESH WATER IN CARGO TANKS 3C,4C, AND 5C._x001C_ _x001C_
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Documentation
Issued 13 May 1991 Resolved
OBTAIN A NEW LOADLINE CERTIFICATE FROM THE AMERICAN BUREAU OF SHIPPING REFLECTING THE NEW STABILITY LETTER ALLOWING THE CARRIAGE OF POTABLE FRESH WATER IN CARGO TANKS 3C, 4C, AND 5C.
Condition: Unknown
Due 13 May 1991
Resolved 13 May 1991
Construction/Loadline
Issued 22 April 1991 Resolved
REWELD LOOSE WELD ON THE 16TH BULKHEAD STIFFENER IN WAY OF 3S WING TANK.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
PROVIDE PROPER ZINC ANODES IN WAY OF NO.1 P&S BALLAST TANKS.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
REWELD CRACKED WELD ON THE TOP OF 4TH FRAME IN WAY OF NO. 4S WING TANK.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
REWELD CRACKED WELD ON TOP OF 4TH FRAME IN WAY OF NO. 3P WING TANK.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
PROVIDE PROPER SUPPORT BRACKETS TO THE ELECTRICAL CABLES IN WAY OF NO.5P_x001C_ WING TANKS.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
REWELD LOOSE BRAKET TO THE FRESH WATER SUCTION PIPE LINE IN WAY OF NO.5C_x001C_ CARGO TANKS.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Unknown
Issued 22 April 1991 Resolved
PROVIDE OIL POLLUTION PLACARD POSTED ON BOARD.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Unknown
Issued 22 April 1991 Resolved
PROVIDE A PROPER STABILITY LETTER ISSUED BY G-MSC THAT WILL REFLECT THE TYPE OF CARGO CARRIAGE AND OPERATION OF THE VESSEL.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
REPAIR SOUNDING TUBE IN WAY OF NO. 2S WING TANK.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
CLEAN GASKET SEATS ON ALL HATCH COVERS ON NO. 1P, 1S AND 1C TANKS.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991 Resolved
INSTALL CAPTIVE CHAINS ON ALL DECK HATCH COVERS.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991