Records from 1982 to 2007. Most recent: inspection, 25 June 2007.
Inspection history · 44
25 June 2007
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2975902
23 May 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2656489
15 February 2005
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2293137
27 January 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1989321
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976577
21 July 2003
Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1852665
5 March 2003
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1752882
6 December 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 773194
30 November 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076853
30 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791765
20 November 1998
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 808348
20 November 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811092
14 July 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793954
20 February 1998
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114956
8 February 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 113660
8 February 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112394
18 December 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446578
22 November 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371586
10 May 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456371
11 January 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422625
9 November 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358608
23 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166246
9 September 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 832249
31 August 1993
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403674
30 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 181426
9 July 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1153422
1 May 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449595
24 February 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1147465
20 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1270274
7 May 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 956210
9 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233762
1 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 908705
15 April 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905257
4 February 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927068
26 July 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241915
27 January 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904873
8 May 1989
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209756
22 February 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022930
20 February 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1334238
1 June 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335113
3 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330465
7 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018565
20 February 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299415
12 May 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963755
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 25 June 2007
Resolved
Vessel has SOLAS documents issued by Mexican flag, although vessel does not meet SOLAS 74. Vsl was built in 1981 under Old Subchapter I.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 June 2007
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 15 February 2005
Resolved
No Rescue Boat. Vessel re-flagged from U.S. to Mexico. Owners were unaware of requirements
Due 28 February 2005
Resolved 26 February 2005
Resolution: Rescue boat installed. Crew drill not conducted.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 February 2005
Resolved
Expired.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2005
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 15 February 2005
No resolution recorded
Missing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 15 February 2005
Resolved
Missing Block Diagram.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2005
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 15 February 2005
Resolved
No COFR. Vessel re-flagged from U.S. to Mexico, which changed regulatory tonnage from 277 to 772 GRT. Vessel owners were not apprised of the tonnage change and the subsequent COFR requirements. An application for the COFR was made prior to the vessel's departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 January 2004
Resolved
Prove proper operation of masthead light.
Due 27 January 2004
Resolved 27 January 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 January 2004
Resolved
Clean or replace lense on stern light.
Due 27 January 2004
Resolved 27 January 2004
Navigation › Piloting/Steering
Issued 27 January 2004
Resolved
Post steering gear change over instructions at aft auxiliary steering station IAW 46 CFR 97.37-33
Due 27 January 2004
Resolved 27 January 2004
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 January 2004
Resolved
Terminate dead ended condcutors and exposed terminal block in pilothouse to suitable electrical enclosure. (46 CFR 111.60-17)
Due 27 January 2004
Resolved 27 January 2004
Electrical › Electrical Distribution System (service)
Issued 27 January 2004
Resolved
Install covers on all electrical receptacles in laundry room. (46 CFR 111.79)
Due 27 January 2004
Resolved 27 January 2004
Communications › Radio Communications › EPIRB
Issued 27 January 2004
Resolved
Mount Cat I 406 MHz EPIRB to accomodate float free requirement IAW 46 CFR 199.510(b)
Due 27 January 2004
Resolved 27 January 2004
Resolution: EPIRB and hydrostatic release unit mounted on pilothouse cabin top free from overhead obstruction..
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 January 2004
Resolved
Replace batteries in life buoy electric floating lights (46 CFR 199.190(f)(5).
Due 27 January 2004
Resolved 27 January 2004
Lifesaving › Lifebuoys › Stowage
Issued 27 January 2004
Resolved
Stow at least one life buoy near stern of vessel IAW 46 CFR 199.70(a)(1)(iv).
Action required: 705 - Other - as specified
Due 27 January 2004
Resolved 27 January 2004
Operations/Management › Pollution › Retention of Oily Mixture
Issued 27 January 2004
Resolved
Remove excessive oily waste from machinery space bilges.
Action required: 705 - Other - as specified
Due 27 January 2004
Resolved 27 January 2004
Engineering › Fuel Oil Service System › Hose
Issued 27 January 2004
Resolved
Replace port propulsion engine fuel oil system flexible hose at fuel filter inlet.
Due 27 January 2004
Resolved 27 January 2004
Engineering › Fuel Oil Service System › Hose
Issued 27 January 2004
Resolved
Replace Liquid mud pump prime mover #1 fuel oil system flexible hose at fuel filter outlet.
Due 27 January 2004
Resolved 27 January 2004
Engineering › Fuel Oil Service System › Hose
Issued 27 January 2004
Resolved
Replace #2 diesel generator fuel oil system flex hose at fuel fliter inlet.
Due 27 January 2004
Resolved 27 January 2004
Engineering › Fuel Oil Service System › Filter
Issued 27 January 2004
Resolved
Replace metal guard/drip pan for fuel oil filter bowl assy #1 Liquid Mud Pump auxiliary engine. (46 CFR 56.50-60)
Due 27 January 2004
Resolved 27 January 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 January 2004
Resolved
Provide circuit directory for 440 v panel baord in forward machinery space.(46 CFR 111.40-11)
Action required: 705 - Other - as specified
Due 27 January 2004
Resolved 27 January 2004
Construction/Loadline
Issued 8 February 1998
Resolved
Prior to returning vessel to service, make permanent repairs to deck over port side accomodations area near frame 9 and associated framing.
Condition: Unknown
Due 8 February 1998
Resolved 8 February 1998
Construction/Loadline
Issued 8 February 1998
Resolved
Prior to returning vessel to service, make permanent repairs to port bow chain locker deck where casualty damage has buckled the deck and repair or replace associated damaged framing as discussed.
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Construction/Loadline
Issued 8 February 1998
Resolved
Prior to returning vessel to service, repair or replace forepeak vent.
Condition: Unknown
Due 8 February 1998
Resolved 8 February 1998
Construction/Loadline
Issued 11 January 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Engineering
Issued 1 May 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 May 1993
Resolved 1 May 1993
Engineering
Issued 1 May 1993
Resolved
PROVIDE ON BOARD APPROVED COPY OF ENGINNERING AUTOMATED / MONITORING_x001C_ CONTROL SYSTEM TESTING PROCEDURES._x001C_ _x001C_
Condition: Unknown
Due 1 May 1993
Resolved 1 May 1993
Deck/Cargo
Issued 1 May 1993
Resolved
MAKE DRY BULK TANKS AVAILABLE FOR INTERNAL INSPECTION NOT LATER THAN NEXT DRYDOCK EXAM.
Condition: Unknown
Due 1 May 1993
Resolved 1 May 1993
Deck/Cargo
Issued 1 May 1993
Resolved
REPAIR AND PROVE PROPER OPERATION OF ANCHOR WINDLASS BRAKE.
Condition: Unknown
Due 1 May 1993
Resolved 1 May 1993
Accommodation/Occupational Safety
Issued 1 May 1993
Resolved
REPLACE ENGINE ROOM EMERGENCY EXIT HATCHES(2) COUNTERBALANCE SPRINGS.
Condition: Unknown
Due 1 May 1993
Resolved 1 May 1993
Deck/Cargo
Issued 7 May 1992
Resolved
CROP AND RENEW CARGO TRANSFER LINE IN ENGINE ROOM, OVERHEAD, AFT END OF ENGINE ROOM AT ELBOW. PIPE HAS A PATCH ON IT NOW._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Lifesaving
Issued 7 May 1992
Resolved
INSTALL RETROFLECTIVE TAPE ON VESSEL LIFE RINGS.
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Fire Fighting
Issued 7 May 1992
Resolved
PROVIDE SERVICING REPORT FOR THE FIXED CO2 SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Lifesaving
Issued 7 May 1992
Resolved
REINSTALL BENCH GRINDER GUARD OR REMOVE GRINDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Engineering
Issued 7 May 1992
Resolved
REPLACE GUARD ON PORT AIR COMPRESSOR (MISSING)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Navigation
Issued 7 May 1992
Resolved
REPAIR THE PORT RADAR TO OPERABLE CONDITION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1992
Resolved 7 May 1992
Navigation
Issued 27 January 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF SHIPS RADAR TO THE SATISFACTION OF THEATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 January 1990
Resolved 27 January 1990
Engineering
Issued 27 January 1990
Resolved
TEST BOTH MAIN ENGINE AND BOTH S/S GENERATOR OVERSPEEDS TO THE SATISFACTIONOF THE ATTE4NDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 January 1990
Resolved 27 January 1990
Fire Fighting
Issued 27 January 1990
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF SHIPS FIRE PUMP TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 January 1990
Resolved 27 January 1990
Deck/Cargo
Issued 27 January 1990
Resolved
TEST RELIEF VALVES AND INTERNALLY INSPECT ALL FOUR (4) DRY MUD BULK TANKS TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 27 January 1990
Resolved 27 January 1990
Fire Fighting
Issued 7 March 1987
Resolved
YEARLY INSPECTION OF FIRE EXT CO2 FIXED SYSTEM OVERDUE ONE (1) MONTH. PROVIDE SERVICE REPORT.
Condition: Unknown
Due 7 March 1987
Resolved 7 March 1987