Records from 1982 to 2019. Most recent: inspection, 28 October 2019.
Inspection history · 106
28 October 2019
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6843460
1 September 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6807490
14 February 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6626417
28 January 2019
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6615851
26 January 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6626447
24 August 2018
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6549941
25 July 2018
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6490943
24 July 2015
COC-MODU Renew
Type not classified · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5194783
12 May 2014
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4887149
24 July 2012
Deficiency Check · COC-MODU Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4389098
7 June 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4336870
15 May 2012
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4312237
19 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4227873
3 August 2011
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4132190
4 December 2010
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3920157
8 November 2010
COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3889036
4 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3862964
3 February 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3681948
22 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3769777
27 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3462160
7 January 2009
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3390169
2 December 2008
COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3372717
9 October 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3350629
6 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3339519
18 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132663
12 October 2007
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3078407
14 November 2005
COC-MODU Renew
Type not classified · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2532366
22 October 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1693957
13 September 2002
Construction Oversight
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1687334
14 November 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1076319
2 August 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1440552
13 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064144
10 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050346
9 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050482
31 May 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420339
17 May 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1049785
24 April 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817082
29 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816456
1 March 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1046096
3 February 2000
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1045863
25 October 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792893
4 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043257
31 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 781163
20 July 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1102129
20 June 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051247
19 May 1999
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1456702
5 March 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 91457
29 October 1998
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 804405
19 October 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 106236
15 September 1998
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 798710
11 June 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402673
2 December 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378211
14 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121843
29 September 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1116574
27 June 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 768798
25 June 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 190879
20 June 1997
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1457475
5 May 1997
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1424441
23 April 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1097712
5 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088355
26 June 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242238
12 June 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385744
30 June 1995
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396326
11 April 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 847996
7 March 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1169255
8 February 1995
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371004
16 December 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841427
6 December 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138214
19 July 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870235
14 July 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1177692
16 June 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463834
9 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 852490
3 September 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377042
20 February 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 41466
28 January 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451837
30 December 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 830322
23 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 651401
23 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 667319
21 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 48050
6 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 134051
24 October 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414087
24 June 1992
Deficiency Check · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1256402
12 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1264485
6 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 16596
17 December 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953010
20 June 1991
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 935863
28 June 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904116
21 May 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901957
19 December 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1238562
5 July 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1207786
25 October 1987
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333058
24 August 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319251
27 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326048
2 July 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999444
13 January 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995817
8 August 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296288
11 July 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983588
7 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293260
11 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974333
17 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971292
21 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271608
29 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965960
26 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274927
12 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278163
19 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275565
30 July 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970467
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 1 September 2019
Resolved
Upon installation of the replacement boom on the port crane, provide a statement of fact from class as well as testing documents.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 26 September 2019
Resolution: Received SOF and testing documents, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane high angle kick out override panel was not labeled.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: Panel was labeled and inspected prior to inspectors departing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane has plexi glass in window which cannot be seen through.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 3 April 2019
Resolution: Custom glass cut and replaced in kind; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane has loose wires hanging out of electrical outlet.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: Electrical wires were fixed and inspected prior to the inspectors leaving.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane has rotating machinery not protected by a guard.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: Guard put in place on port crane to cover rotating machinery; all sat.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 14 February 2019
Resolved
Oil record book remains to be substandard. Weekly entries are not being recorded and volumes are incorrect. Vessel must provide one month of good entries to clear this deficiency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 8 April 2019
Resolution: Scanned copy of oil record book for the month of March was sent via email and reviewed; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Marine Operations Manual must be approved by Coast Guard.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: CG Approval letter not required for MOM-Ed Lacy, OCS CID made this determination.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2019
Resolved
MODU suffered equipment casualty that resulted in catastrophic failure of the starboard crane and injury to the crane operator. Unit shall suspend all crane activities on the PORT crane until a OEM report stating the PORT crane meets API RP 2D oerating standards and is safe for operation has been recieved by the District Eight OCS OCMI.
Action required: 705 - Other - as specified
Resolved 14 February 2019
Resolution: Reviewed inspection report from OES. Port crane is available for use.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2019
Resolved
Unit shall effect repairs to the STBD crane to OEM standards and provide OEM report stating the STBD crane meets API RP 2D operating standards and is safe for operation prior to using crane for MODU operations.
Action required: 705 - Other - as specified
Resolved 14 February 2019
Resolution: Reviewed inspection report from OES. STBD crane is available for use.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
The operator of each manned OCS facility shall develop an Emergency Evacuation Plan (EEP) and submit to the District 8 OCS OCMI 30 days before placing the facility in operation. At the time of inspection, no EEP could be produced for inspection and no proof of submission was provided.
33 CFR 146.10(a)
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Each unit must have on board an operating manual approved by the Coast Guard (ABS as RO) as meeting the requirements of 46 CFR 109.231. The operating manual provided at time of inspection had not been updated to reflect changes in lightship characteristics and emergency shutdowns.
46 CFR 109.121 (Old IA)
Condition: Invalid
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 25 July 2018
Resolved
Units Shipboard Oil Pollution emergency plan issued under section 5.1 of the IOPP supplement (form A) does not contain the procedures and points of contacts for coordinating action with national and local authorities in combating pollution.
MARPOL Annex I / reg 37.2.4
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 25 July 2018
Resolved
Details of fuel oil delivered to and used on board shall be recorded by means of a bunker delivery note and a representative sample of the fuel oil delivered. Unit has no record of bunker delivery notes and does not have any samples of recent fuel oil delivered.
MARPOL Annex VI / reg 18.5 and 18.8.1
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 July 2018
Resolved
Davits for launching liferafts were removed. This makes the max allowable POB 54, vice 78 as per Safety Certificate.
46 CFR 108.515 & 108.525
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 25 July 2018
Resolved
Details of fuel oil delivered to and used on board shall be recorded by means of a bunker delivery note and a representative sample of the fuel oil delivered. Unit has no record of bunker delivery notes and does not have any samples of recent fuel oil delivered.
MARPOL Annex VI / reg 18.5 and 18.8.1
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 July 2018
Resolved
Davits for launching liferafts were removed. This makes the max allowable POB 54, vice 78 as per Safety Certificate.
46 CFR 108.515 & 108.525
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 25 July 2018
Resolved
Embarkation lights for life rafts are burnt out. Entry into water must be illuminated.
46 CFR 108.170 Note 2, Sends to J; 112.43-11
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 July 2018
Resolved
Ring life buoy on STBD side main deck is not mounted for quick release and the light is inoperable.
46 CFR 108.515(b)(1) & (c).
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 July 2018
Resolved
Grating in front of L/B #2 is not secure. Grating at port side life raft is wasted.
33 CFR 142.87
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 25 July 2018
Resolved
Eyewash stations are missing in the welding machine shop were a great risk of eye injury exist due to grinding machinery. The eyewash stations in the pit room and engine room have insufficient pressure.
33 CFR 142.48
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2018
Resolved
Galley has ample grease built up under stove and fryer presenting a fire hazard.
46 CFR 109.203
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 25 July 2018
Resolved
Old pads left behind from removed equipment presents tripping hazards in front of main generators. Inspectors witnessed barge supervisor trip and almost fell.
33 CFR 142.84
Condition: Damaged By Earlier Event
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 July 2018
Resolved
Obstruction light by the #2 Lifeboat is being blocked by the Lifeboat winch handrail. The light should be place on a higher pole or moved to outer handrail for 360 degree clear visibility.
33 CFR 67.05-1 (f)
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2018
Resolved
Reverse Power Relay on the MDG's is not operable.
46 CFR 108.109
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2018
Resolved
There are no records for any pressure vessels onboard. The inspection history is non-existent. There are no U1A’s from installation, or record of tests.
MSM Vol. II G, sends to F
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2018
Resolved
Upon loss of power, diesel fuel leaks all over the deck in the generator room. There is no check valve on the diesel tank centrifuge, so the head pressure on the diesel tank leaks by the gasket at an accelerated rate.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 25 July 2018
Resolved
The Oil Record Book does not have proper entries.
Annex 1, Reg 17
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 July 2018
Resolved
Drains installed for the A/C in the SCR room comprimise the structural fire protection. In addition, the previous ventilation system was removed and blanked, but structural fire protection was not repaired
46 CFR 108. 137
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2018
Resolved
Electrical junction box in galley is not secure and wires are exposed.
46 CFR 108.170
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 July 2018
Resolved
Lock out, Tag out system must remain up to date. Tags were found on equipment that were greater than 4 years old.
33 CFR 142.90
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2018
Resolved
Explosion proof boxes on drill floor have been painted over, compromising the flame path seal on the sides.
46 CFR 108.170 Note 2
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 July 2018
Resolved
Watertight integrity below the deck is insufficient. Watertight doors were welded on and compromised. One door was installed upside down. Conduct survey of all watertight closures; repair as necessary.
46 CFR 108.301
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 14 February 2019
Resolution: Visited vessel and inspected 10 watertight doors which were cut out and replaced. ABS approved installation and tested; all sat.
Lifesaving › Lifeboat › Propulsion Engine
Issued 24 July 2012
Resolved
The port lifeboat is currently inoperable. Prove full operation of the port lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2012
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 24 July 2012
Resolved
The davit launched liferafts have been removed. Install a CG approved davit and rafts prior to departure from port.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2012
Resolution: Per discussion between [name withheld] & [name withheld], MODU was allowed to retain throw-over / float free liferaft arrangement.
Lifesaving › Launching Appliances › Davit
Issued 24 July 2012
Resolved
Limit switches for both lifeboats are not operating properly. Demonstrate proper operation of both lifeboat limit switches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2012
Operations/Management › Equipment Service/Testing › EPIRB
Issued 24 July 2012
Resolved
None of the tests & inspections required by 46 CFR 109 subparts B & C have been conducted. Conduct tests & inspections prior to commencing drilling operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 November 2012
Electrical › Electric Supply System (service) › Cable
Issued 24 July 2012
Resolved
Purge protection for the camera monitor could not be demonstrated. Prove proper operation of purge protection for the camera monitor prior to commencing drilling operations.
Action required: 705 - Other - as specified
Resolved 7 November 2012
Electrical › Electric Supply System (service) › Cable
Issued 24 July 2012
Resolved
Mud pit alarms are inoperative. Prove proper operation of the mud pit alarms prior to commencing drilling operations.
Action required: 705 - Other - as specified
Resolved 7 November 2012
Construction/Loadline › Structures › Scuttle
Issued 24 July 2012
Resolved
Engine room escape hatch is seized. Prove proper operation of the engine room escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 24 July 2012
Resolved
Prove proper operation of the gas detectors as listed on the fire control plan. Prove prior to commencing drilling operations.
Action required: 705 - Other - as specified
Resolved 7 November 2012
Engineering › Fuel Oil Service System › Tank
Issued 24 July 2012
Resolved
Prove proper installation of top drive generator on main deck, including the fuel tank installation, iaw 46 CFR subchapters "F" & "J': 1) Provide 30x30 mesh flame screen on portable fuel tank vent; 2) Ensure return fuel line on portable tank has SAE 1942 approved fuel hose <30 inches in length; 3) Prove alarms are working for high jacket water temp & low lube oil at alarm panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2012
Operations/Management › Drills/Instruction › Fire
Issued 24 July 2012
Resolved
Conduct satisfactory fire & abandon drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 24 July 2012
Resolved
Prove operation of the total rig shutdown as per the approved operations manual.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2012
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 July 2012
Resolved
Prove operation of emergency lighting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2012
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 24 July 2012
Resolved
Prove proper operation of louvers for emergency generator room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2012
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 24 July 2012
Resolved
Prove that gas detection display unit RD-64X-N7 in the drill shack is Coast Guard approved for installation in a hazardous location. Complete prior to commencing drilling operations.
Action required: 705 - Other - as specified
Resolved 13 November 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 July 2012
Resolved
Properly repair the Rox Blocks outside emergency generator house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 December 2012
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 July 2012
Resolved
Prove proper operation of all eyewash & shower stations.
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 December 2012
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 24 July 2012
Resolved
Provide gasket & bolts for standard discharge connection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 July 2012
Resolved
Replace A/C voltmeter on #2 generator panel & ammeter on #1 generator panel.
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 24 July 2012
Resolved
Provide ground detection test button & frequency meter on emergency generator panel.
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Construction/Loadline › Structures › Ventilators
Issued 24 July 2012
Resolved
Provide access & means to close all ventilation systems.
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 July 2012
Resolved
Permanently wire total rig shutdown control box in SCR room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2012
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 July 2012
Resolved
Update all circuit directory cards in all distribution panels.
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 July 2012
Resolved
Band cabling in MCCs #1 & #2 compressor rooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 July 2012
Resolved
Properly blank off open spaces in power panel CKT L2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 24 July 2012
Resolved
Provide cover plates for light switches in the galley & for the light switch in company man's bathroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2012
Resolved 13 November 2012
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 3 August 2011
Resolved
Repair shower fixture in shower area located by laundry room.
Action required: 705 - Other - as specified
Resolved 17 August 2011
Resolution: Received e-mail and photo documentation attesting to the correction of discrepancy.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 3 August 2011
Resolved
Replace dryer vent hoses with metallic hoses/hard piping.
Action required: 705 - Other - as specified
Resolved 17 August 2011
Resolution: Received e-mail and photo documentation attesting to the correction of discrepancy.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 3 August 2011
Resolved
Place cover on junction box behind washer/dryers. If cover cannot be located replace with new junction box.
Action required: 705 - Other - as specified
Resolved 17 August 2011
Resolution: Received e-mail and photo documentation attesting to the correction of discrepancy.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 3 August 2011
Resolved
Secure washer and dryers to deck or bulkhead to prevent movement and tipping hazard.
Action required: 705 - Other - as specified
Resolved 17 August 2011
Resolution: Received e-mail and photo documentation attesting to the correction of discrepancy.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 3 August 2011
Resolved
Clean behind washer and dryers to remove loose lint and debris.
Action required: 705 - Other - as specified
Resolved 17 August 2011
Resolution: Received e-mail and photo documentation attesting to the correction of discrepancy.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 8 November 2010
Resolved
Ensure new non-collapsible suction hose is installed on port foam station.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 4 December 2010
Resolution: Replaced non-collapsible hose on 11/10/10.
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 8 November 2010
Resolved
Ensure foam concentrate tank is made weatherproof/watertight around lid.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 4 December 2010
Resolution: Replaces tank cover.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 8 November 2010
Resolved
Ensure messroom and galley are made to comply with "A" fire boundary standards and that fire control plan reflects changes.
Action required: 705 - Other - as specified
Due 8 January 2011
Resolved 6 April 2012
Resolution: Verified fire control plan was updated.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 8 November 2010
Resolved
Ensure IAPP reflects HALON fire protection system on board.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 4 December 2010
Resolution: ABS issued IAPP with HALON information.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 November 2010
Resolved
Ensure Lifeboat #1 station is properly lit with emergency lighting. Currently no installed "E"-lighting at station.
Action required: 705 - Other - as specified
Due 8 December 2010
Resolved 4 December 2010
Resolution: E-Light was rebuilt and operates under E-power
Stability › Watertight Integrity › General
Issued 8 November 2010
Resolved
Ensure STBD heavy equipment room deck hatch is made watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2010
Resolution: Replaced hinges and pins on 11/10/10.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 12 October 2007
Resolved
Repair exhaust leak on emergency generator to the satisfaction of flag.
Due 1 November 2007
Resolved 2 November 2007
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 12 October 2007
Resolved
Repair/install class A doors into galley and mess deck (door into mess deck from passage way and door into dry stores).
Due 25 November 2007
Resolved 2 November 2007
Lifesaving › Launching Appliances › Davit
Issued 12 October 2007
Resolved
Repair/service limit switches for port and starboard lifeboats.
Due 1 November 2007
Resolved 2 November 2007
Unknown
Issued 2 August 2001
Resolved
Make dry bulk tanks available for internal inspection.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Unknown
Issued 2 August 2001
Resolved
Provide relief valves with proper identification for air receivers in compressor room, mechanic's workshop and dry bulk tanks.
Condition: Unknown
Due 2 August 2001
Resolved 2 August 2001
Lifesaving
Issued 31 May 2000
Resolved
RENEW LIFELINES ON BOTH LIFEBOATS.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Engineering
Issued 31 May 2000
Resolved
RENEW FUEL OIL SUPPLY AND RETURN LINES ON EMERGENCY GENERATOR WITH MARINE APPROVED TYPE (SAE J 1942 SPEC).
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Construction/Loadline
Issued 17 May 2000
Resolved
Make drill water tanks ready for inspection.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Construction/Loadline
Issued 3 February 2000
Resolved
Conduct Phase two SEILODD.
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Construction/Loadline
Issued 3 February 2000
Resolved
Insert deck where holed in mud pit room.
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Construction/Loadline
Issued 3 February 2000
Resolved
Crop and renew drain line where soft patched in nr. 6 centerline void.
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Construction/Loadline
Issued 3 February 2000
Resolved
Make drill water and preload tanks available for inspection.
Condition: Unknown
Due 3 February 2000
Resolved 3 February 2000
Fire Fighting
Issued 19 May 1999
Resolved
CONDUCT FIRE & BOAT DRILL PRIOR TO OPERATION OF RIG
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
REPAIR WASTAGE IN EMERG ESCAPE HATCH LOCATED IN ENG ROOM
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Electrical
Issued 19 May 1999
Resolved
REPLACE MISSING LENS ON JUNCTION BOX OVER #24 WTD
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Deck/Cargo
Issued 19 May 1999
Resolved
REPLACE WORN FLEX CONNECTION ON MUD PUMP.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
REPLACE/REPAIR HANDLE ON BILGE VALVE IN ENG ROOM
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
PROVE PROPER OPERATION OF ENG ROOM BILGE PUMP.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Electrical
Issued 19 May 1999
Resolved
REPLACE BURNED OUT SYNC LIGHTS ON GEN SWITCHBOARD
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
REPAIR LEAK IN PACKING GLAND ON RAW WATER PUMP LOCATED IN ENG ROOM.
Condition: Unknown
Due 24 May 1999
Resolved 24 May 1999
Unknown
Issued 11 June 1998
Resolved
COMPLETE REPAIRS TO #2 (PORT) CRANE AS DIRECTED BY ABS REPORT DATED 10JUN98.
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Lifesaving
Issued 11 June 1998
Resolved
REPAIR SHUT-DOWN COIL ON #2 MAIN GENERATOR PRIME MOVER. CONDUCT SATISFACTORY TEST OF TOTAL RIG EMERGENCY SHUT-DOWN, LOG PROPERLY.
Condition: Unknown
Due 24 June 1998
Resolved 26 June 1998
Lifesaving
Issued 11 June 1998
Resolved
CONDUCT OPERATIONAL TEST OF RELEASING GEAR WITH BOAT LOADED TO 1.1 ON BOTH BOATS.
Condition: Unknown
Due 24 June 1998
Resolved 25 June 1998
Lifesaving
Issued 5 May 1997
Resolved
REPLACE BOLTS ON LIFE BOAT WINCHES.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Documentation
Issued 5 May 1997
Resolved
PROVIDE COAST GUARD WITH COPY OF GAUGING REPORT.
Condition: Unknown
Due 5 June 1997
Resolved 11 June 1997
Construction/Loadline
Issued 5 May 1997
Resolved
REPAIR WATERTIGHT DOORS #28 AND #29
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 5 May 1997
Resolved
REPLACE ALL CRACKED WATERTIGHT DOOR GASKETS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 5 May 1997
Resolved
REPAIR OR REPLACE SEA CHEST VALVE IN MACHINERY SHOP
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Lifesaving
Issued 5 May 1997
Resolved
REPLACE BAD GRATING BY PORT LIFE BOAT.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 5 May 1997
Resolved
PROVIDE REPORT OF MPI/DYE PENETRANT EXAM OF #4-6 PINHOLES ABOVE JACKHOUSE AT MINIMUM SEPARATION.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 5 May 1997
Resolved
CONDUCT SWIM-BY OF MAT BOTTOM AND SKIRT AREA, PROVIDE REPORT TO COAST GUARD.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 5 May 1997
Resolved
REPLACE WASTED BOTTOM STIFFNERS IN 3 STARBOARD TANK
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 11 April 1995
Resolved
PROVIDE ABS REPLY TO NOBLE REPAIR PROPOSAL FOR MAT DAMAGE AS OUTLINED IN ABS MORGAN CITY UWILD REPORT OF 06MAR95 (ITEMS 1B, 2C, 4D). SUBMIT TO [name withheld], TX FOR REVIEW AND COMMENT.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Construction/Loadline
Issued 8 February 1995
Resolved
COMPLETE LOWER HULL PORTION OF SEILOD (NDT OF LEG TO MAT CONNECTIONS AND SWIM-BY OF MAT).
Condition: Unknown
Due 8 February 1995
Resolved 8 February 1995
Engineering
Issued 16 June 1994
Resolved
CROP CAND RENEW FUEL TANK VENT AT PORT MAIN DECK BY QUARTERS.
Condition: Unknown
Due 16 June 1994
Resolved 16 June 1994
Navigation
Issued 16 June 1994
Resolved
REPAIR OR RENEW AND PROVE PROPER OPERATION OF PORT BOW OBSTRUCTION LIGHT LAMP CHANGER.
Condition: Unknown
Due 16 June 1994
Resolved 16 June 1994
Construction/Loadline
Issued 16 June 1994
Resolved
MAKE REPAIRS TO 1 PORT TANK (HORSE SHOE SHAPED DAMAGE, 9" LONG X 1/2" WIDE)AND STARBOARD MAT FINGER LOWER AFT SIDE SHELL PLATING APPROX. 20' OUTBOARD OF THE KEYWAY AREA IN 4 STARBOARD (APPROX. 2"X4" HOLE)._x001C_
Condition: Unknown
Due 16 June 1994
Resolved 16 June 1994
Construction/Loadline
Issued 24 October 1992
Resolved
SUBMIT REPAIR PROPOSAL FOR DAMAGE LOCATED DURING UNDERWATER SWIM-BY ON 24 OCT 92.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Construction/Loadline
Issued 24 October 1992
Resolved
COMPLETE SEILODD INSPECTION ASPER CHILES OFFSHORE PROPOSED PLAN DATED 13 OCT 92 AND MORMS LETTER DATED 21 OCT 92.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 24 June 1992
Resolved
EMPTY, CLEAN, VENTILATE, AND MAKE THE DRY BULK PRESSURE VESSELS (P-TANKS)_x001C_ AVAILABLE FOR INTERNAL EXAMINATION AT NEXT DRYDOCK OR SEILOD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1992
Resolved 24 June 1992
Electrical
Issued 24 June 1992
Resolved
MAKE PERMANENT REPAIRS TO #2 SERVICE GENERATOR ENGINE TACHOMETER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 24 June 1992
Resolved
MAKE PERMANENT REPAIRS TO SACK ROOM AIR FLOW SENSOR FOR LOSS OF VENT ALARM.
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 24 June 1992
Resolved
PROVIDE TONGUE GUARD FOR MACHINERY SHOP BENCH GRINDER .
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Fire Fighting
Issued 24 June 1992
Resolved
MAKE PERMANENT REPAIRS TO LEAKING CASING GASKET ON #1 FIRE PUMP._x001C_
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 24 June 1992
Resolved
REPAIR FIBERGLASS FRACTURES ON PORT AND STARBOARD LIFEBOAT. _x001C_ FRACTURES LOCATED ON CANOPY BUMPER PADS.
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Lifesaving
Issued 24 June 1992
Resolved
RENEW ALL OUTDATED EMERGENCY WATER RATIONS ON BOTH LIFE BOATS (40 QTS PER BOAT).
Condition: Unknown
Due 30 July 1992
Resolved 30 July 1992
Electrical
Issued 28 June 1990
Resolved
TEST REVERSE POWER RELAYS IN THE PRESENCE OF A COAST GUARD INSPECTOR AFTER MAKING THE NECESSARY REPAIRS TO GOVERNORS ON #2, #3 EMDS.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Electrical
Issued 28 June 1990
Resolved
PROVIDE SEALED FITTINGS FOR CONSOLE POWER SUPPLY EXPLOSION PROOF SWITCH BOX(NOTE: IF BICED FITTINGS ARE USED ENSURE TYPE FOR UNARMED CABLE).
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Electrical
Issued 28 June 1990
Resolved
PROVIDE PURGE AND LOSS OF PURGE ALARMS FOR 4 EA PURGE BOXES BEHIND INDICAT-ORCONSOLE ON RIG FLOOR, IN ACCORDANCE WITH NFPA 496.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Electrical
Issued 28 June 1990
Resolved
PROVIDE TEST OF OVERSPEED SHUTDOWN, LOW LUBE OIL SHUT DOWN AND HIGH TEMP ALARM #1 EMD. PROVIDE TEST AND PROPER OPERATION OF LOW LUBE OIL SHUTDOWN #2,#3 EMD.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Electrical
Issued 28 June 1990
Resolved
PROVIDE LOSS OF PURGE ALARM TO DRILLERS CONSOLE IN ACCORDANCE WITH NFPA 496ALARM SHOULD DETECT LOOSS OF PURGE INSIDE OF THE CABINET NOT AS PRESENTLY CONFIGURED WITH ORFICE AGAINST THE DOOR.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Fire Fighting
Issued 28 June 1990
Resolved
PROVIDE ANTI CLOSE LATCH FOR SCBA BOTTLE IN P TANK ROOM.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Lifesaving
Issued 28 June 1990
Resolved
DETERMINE CAUSE OF HIGH PITCHED NOISE IN #2 LIFEBOAT ENGINE. APPEARS TO BEA LOOSE DRIVE BELT AND MIS ALLIGNED RAW WATER PUMP.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Navigation
Issued 28 June 1990
Resolved
PROVIDE FOR INTERNAL EXAMINATION ALL PRESSURE VESSELS AND TEST OF RELEIF VALVES.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Lifesaving
Issued 28 June 1990
Resolved
PROVIDE FOR TESTING OF GENERAL ALARM BELLS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Fire Fighting
Issued 28 June 1990
Resolved
PROVIDE FOR TESTING OF THE QUARTERS AND MACHINERY VENT ILATION SHUT DOWNS.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Electrical
Issued 28 June 1990
Resolved
PROVIDE EXPLOSION PROOF INSTALATION OF SWACO STROKE RATE METER ON RIG FLOOR.
Condition: Unknown
Due 28 June 1990
Resolved 28 June 1990
Engineering
Issued 5 July 1988
Resolved
CONDUCT GAUGINGS OF PITTED AREA ON THE AFT SIDE OF THE MIDDLE CEMENT TANK, SIX FEET ABOVE DECK LEVEL, BEFORE COMPLETING REPAIRS.
Condition: Unknown
Due 5 July 1988
Resolved 5 July 1988
Construction/Loadline
Issued 24 August 1987
Resolved
MAKE AVAILABLE FOR A COAST GUARD INSPECTION OF THE INTERVAL OF THE 5 MUD PIT PUMP VALVES AND 5 MUD PIT CHECK VALVES.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Fire Fighting
Issued 24 August 1987
Resolved
PROVIDE PLANS AND MATERIAL SCHEDULE FOR LIGHTWATER SYSTEM INSTALLED FOR MUDPIT ROOM AND SHALE SHAKERS FOR APPROVAL BY OFFICER IN CHARGE MARINE INSPEC.NOLA.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Construction/Loadline
Issued 24 August 1987
Resolved
CONDUCT THE UNDER WATER PORTION OF THE SPECIAL EXAMINATION IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Electrical
Issued 24 August 1987
Resolved
CONUDUCT TESTING OF OVERSPEED AND SAFETY DEVICES ON THREE SHIP SERVICE GENERATORS AND ONE EMERGENCY GENERATOR TO THE SATISFACTION OF A A MARINE INSPECTOR. TESTING TO INCLUDE ELECTRICAL CONTROLS AND REVERSE.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Electrical
Issued 24 August 1987
Resolved
CONDUCT OPERATIONAL TESTS OF THE EMERGENCY GENERATOR AND AUTOMATIC BUS TRANSFER SWITCH IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Electrical
Issued 24 August 1987
Resolved
INSTALL APPROPIATE ELECTRICAL JUNCTION BOX AND FITTINGS FOR MUD CYCLONE UNIT POWER SUPPLY LOCATED ON FLAT OUTBOARD OF THE SHALE SHAKE AREA. UNIT EXTNDS THE HAZARDOUS LOCATION ZONE AND REQUIRES EXPLOSION PROOF ELEC. INSTALLATIONS.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Lifesaving
Issued 2 July 1986
Resolved
CONDUCT WEIGHT TESTS IN THE PRESENCE OF A U. S. COAST GUARD MARINE INSPECTOR. ALSO TEST THE LIMIT SWITCHES FOR THE #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Lifesaving
Issued 2 July 1986
Resolved
PROVIDE THE #1 & #2 LIFEBOATS WITH A SECOND PAINTER, OPERABLE INTERIOR LIGHTING, AND 12 SERVICEABLE RED DISTRESS FLARES.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Navigation
Issued 2 July 1986
Resolved
INSTALL APPROVED LIGHTING COMPONENTS FOR THE PORT NAVIGATIONAL SIDELIGHT.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Accommodation/Occupational Safety
Issued 2 July 1986
Resolved
MAKE REPAIRS AND RETURN TO SERVICE THE INOPERABLE RED FOX MARINE SANITATIONDEVICE.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Documentation
Issued 2 July 1986
Resolved
PROVIDE A CURRENT CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Fire Fighting
Issued 2 July 1986
Resolved
HYDROSTATICALLY TEST BOTH HELIPORT B-V FIRE EXTINGUISHER PRESSURE BOTTLES.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Electrical
Issued 11 July 1985
Resolved
IN THE PRESENCE OF U.S. COAST GUARD INSPECTOR TEST 3 GENERATOR DIESEL OVERSPEEDS LOW LUG ALARMS AND HIGH TEMPERATURE ALARMS (REF 46CFR107.231)
Condition: Unknown
Due 11 July 1985
Resolved 11 July 1985
Unknown
Issued 11 July 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU GRIFFIN ALEXANDER VII DN649720. THE COMPLIANCE DATE IS 10 AUGUST 1985.
Condition: Unknown
Due 11 July 1985
Resolved 11 July 1985
Lifesaving
Issued 11 July 1985
Resolved
REPLACE GLADDING TYPE LIFEJACKETS WITH U.S. COAST GUARD APPROVED LIFEJACKETS (REF 46CFR108.514).
Condition: Unknown
Due 11 July 1985
Resolved 11 July 1985
Electrical
Issued 11 July 1985
Resolved
TEST IN PRESENCE OF U.S. COAST GUARD ALL THREE REVERSE POWER RELAYS (REF 46CFR107.231).
Condition: Unknown
Due 11 July 1985
Resolved 11 July 1985
Unknown
Issued 7 March 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL GRIFFIN ALEXANDER DN649720
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Construction/Loadline
Issued 7 March 1985
Resolved
MAKE AVAILABLE FOR INSPECTION THE MAT SKIRT AND BOTTOM UPON THE NEXT RIG MOVE.
Condition: Unknown
Due 7 March 1985
Resolved 7 March 1985
Electrical
Issued 26 July 1983
Resolved
REPLACE WITH AN EXPLOSION PROOF MODEL OR MOVE OUSIDE OF THE CLASSIFIED AREA, THE ALARM BUZZER AT THE STRARBOARD UPPER FORWARD CONNER OF THE DRILL.
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Navigation
Issued 26 July 1983
Resolved
PROVIDE THE FOLLOWING 1972 COLREG DAY SHAPES; THREE (3) BLACK BALLS AND ONE (1) BLACK DIAMOND.
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Accommodation/Occupational Safety
Issued 26 July 1983
Resolved
CLEAN THE LABLE PLATES ON THE BILGE SYSTEM MANIFOLD VALVES. (REFERENCE 46 CFR 56.50-50/90)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Construction/Loadline
Issued 26 July 1983
Resolved
REPLACE SELF-CLOSING DEVICE ON DOOR BETWEEN MUDPIT ROOM AND MUD PUMP ROOM. (REFERENCE 46 CFR 108.170)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Electrical
Issued 26 July 1983
Resolved
MOVE GENERAL ALARM BELL IN DRY 5 AC ROOM OUT OF CLASSIFIED AREA OR MAKE EXPLOSION PROOF. (REFERENCE 46 CFR 108.170)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Electrical
Issued 26 July 1983
Resolved
PROVIDE A VISUAL INDICATION OR AUDIBLE ALARM FOR LOSS OF PURGE AIR ON THE GENERAL ALARM ON THE DRILL FLOOR. (REFERENCE 46 CFR 108.170)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Documentation
Issued 26 July 1983
Resolved
SUBMIT CONSTRUCTION PORTFOLIO FOR APPROVAL OR R PROVIDE EVIDENCE OF PRIOR APPROVAL. (REFERENCE 46 CFR 107.305HH)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Electrical
Issued 26 July 1983
Resolved
RESPLICE WIRE ON PORT SIDE OF THE DRILL FLOOR ENCLOSURE. (REFERENCE 46 CFR 11.80.5)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Deck/Cargo
Issued 26 July 1983
Resolved
PROVIDE ROPE GUARD FOR KELLEY AIR TUGGER ON DRILL FLOOR. (REFERENCE 46 CFR 108.223)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Deck/Cargo
Issued 26 July 1983
Resolved
PROVIDE FLAME SCREENS FOR ALL FUEL OIL VENTS. (REFERENCE 46 CFR 5-.50-85)
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Construction/Loadline
Issued 26 July 1983
Resolved
MAKE THE BOUNDRY OF THE SACK ROOM A CLASS "A" BULKHEAD AS INDICATED BY THE FIRE CONTROL PLAN OR SUBMIT A NEW FIRE CONTROL PLAN FOR APPROVAL.
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Unknown
Issued 26 July 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL ALEXANDER VII, DN649720
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983
Fire Fighting
Issued 26 July 1983
Resolved
PROVIDE TWO (2) TEN (10) FOOT, LOW VELOCITY FOG APPLICATORS FOR HELO DECK IN ACCORDANCE WITH 46 CFR 108.425D2.
Condition: Unknown
Due 26 July 1983
Resolved 26 July 1983