Records from 1998 to 2019. Most recent: inspection, 28 October 2019.
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 1 September 2019
Resolved
Upon installation of the replacement boom on the port crane, provide a statement of fact from class as well as testing documents.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 September 2019
Resolved 26 September 2019
Resolution: Received SOF and testing documents, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane high angle kick out override panel was not labeled.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: Panel was labeled and inspected prior to inspectors departing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane has plexi glass in window which cannot be seen through.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2019
Resolved 3 April 2019
Resolution: Custom glass cut and replaced in kind; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane has loose wires hanging out of electrical outlet.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: Electrical wires were fixed and inspected prior to the inspectors leaving.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Port crane has rotating machinery not protected by a guard.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: Guard put in place on port crane to cover rotating machinery; all sat.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 14 February 2019
Resolved
Oil record book remains to be substandard. Weekly entries are not being recorded and volumes are incorrect. Vessel must provide one month of good entries to clear this deficiency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 8 April 2019
Resolution: Scanned copy of oil record book for the month of March was sent via email and reviewed; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 February 2019
Resolved
Marine Operations Manual must be approved by Coast Guard.
Action required: 705 - Other - as specified
Due 25 February 2019
Resolved 14 February 2019
Resolution: CG Approval letter not required for MOM-Ed Lacy, OCS CID made this determination.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2019
Resolved
MODU suffered equipment casualty that resulted in catastrophic failure of the starboard crane and injury to the crane operator. Unit shall suspend all crane activities on the PORT crane until a OEM report stating the PORT crane meets API RP 2D oerating standards and is safe for operation has been recieved by the District Eight OCS OCMI.
Action required: 705 - Other - as specified
Resolved 14 February 2019
Resolution: Reviewed inspection report from OES. Port crane is available for use.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 January 2019
Resolved
Unit shall effect repairs to the STBD crane to OEM standards and provide OEM report stating the STBD crane meets API RP 2D operating standards and is safe for operation prior to using crane for MODU operations.
Action required: 705 - Other - as specified
Resolved 14 February 2019
Resolution: Reviewed inspection report from OES. STBD crane is available for use.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
The operator of each manned OCS facility shall develop an Emergency Evacuation Plan (EEP) and submit to the District 8 OCS OCMI 30 days before placing the facility in operation. At the time of inspection, no EEP could be produced for inspection and no proof of submission was provided.
33 CFR 146.10(a)
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Each unit must have on board an operating manual approved by the Coast Guard (ABS as RO) as meeting the requirements of 46 CFR 109.231. The operating manual provided at time of inspection had not been updated to reflect changes in lightship characteristics and emergency shutdowns.
46 CFR 109.121 (Old IA)
Condition: Invalid
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 25 July 2018
Resolved
Units Shipboard Oil Pollution emergency plan issued under section 5.1 of the IOPP supplement (form A) does not contain the procedures and points of contacts for coordinating action with national and local authorities in combating pollution.
MARPOL Annex I / reg 37.2.4
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 25 July 2018
Resolved
Details of fuel oil delivered to and used on board shall be recorded by means of a bunker delivery note and a representative sample of the fuel oil delivered. Unit has no record of bunker delivery notes and does not have any samples of recent fuel oil delivered.
MARPOL Annex VI / reg 18.5 and 18.8.1
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 July 2018
Resolved
Davits for launching liferafts were removed. This makes the max allowable POB 54, vice 78 as per Safety Certificate.
46 CFR 108.515 & 108.525
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 25 July 2018
Resolved
Details of fuel oil delivered to and used on board shall be recorded by means of a bunker delivery note and a representative sample of the fuel oil delivered. Unit has no record of bunker delivery notes and does not have any samples of recent fuel oil delivered.
MARPOL Annex VI / reg 18.5 and 18.8.1
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 July 2018
Resolved
Davits for launching liferafts were removed. This makes the max allowable POB 54, vice 78 as per Safety Certificate.
46 CFR 108.515 & 108.525
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 25 July 2018
Resolved
Embarkation lights for life rafts are burnt out. Entry into water must be illuminated.
46 CFR 108.170 Note 2, Sends to J; 112.43-11
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 July 2018
Resolved
Ring life buoy on STBD side main deck is not mounted for quick release and the light is inoperable.
46 CFR 108.515(b)(1) & (c).
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 July 2018
Resolved
Grating in front of L/B #2 is not secure. Grating at port side life raft is wasted.
33 CFR 142.87
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 25 July 2018
Resolved
Eyewash stations are missing in the welding machine shop were a great risk of eye injury exist due to grinding machinery. The eyewash stations in the pit room and engine room have insufficient pressure.
33 CFR 142.48
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2018
Resolved
Galley has ample grease built up under stove and fryer presenting a fire hazard.
46 CFR 109.203
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 25 July 2018
Resolved
Old pads left behind from removed equipment presents tripping hazards in front of main generators. Inspectors witnessed barge supervisor trip and almost fell.
33 CFR 142.84
Condition: Damaged By Earlier Event
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 July 2018
Resolved
Obstruction light by the #2 Lifeboat is being blocked by the Lifeboat winch handrail. The light should be place on a higher pole or moved to outer handrail for 360 degree clear visibility.
33 CFR 67.05-1 (f)
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2018
Resolved
Reverse Power Relay on the MDG's is not operable.
46 CFR 108.109
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2018
Resolved
There are no records for any pressure vessels onboard. The inspection history is non-existent. There are no U1A’s from installation, or record of tests.
MSM Vol. II G, sends to F
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 July 2018
Resolved
Upon loss of power, diesel fuel leaks all over the deck in the generator room. There is no check valve on the diesel tank centrifuge, so the head pressure on the diesel tank leaks by the gasket at an accelerated rate.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 25 July 2018
Resolved
The Oil Record Book does not have proper entries.
Annex 1, Reg 17
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 July 2018
Resolved
Drains installed for the A/C in the SCR room comprimise the structural fire protection. In addition, the previous ventilation system was removed and blanked, but structural fire protection was not repaired
46 CFR 108. 137
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2018
Resolved
Electrical junction box in galley is not secure and wires are exposed.
46 CFR 108.170
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 July 2018
Resolved
Lock out, Tag out system must remain up to date. Tags were found on equipment that were greater than 4 years old.
33 CFR 142.90
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2018
Resolved
Explosion proof boxes on drill floor have been painted over, compromising the flame path seal on the sides.
46 CFR 108.170 Note 2
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 21 August 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 July 2018
Resolved
Watertight integrity below the deck is insufficient. Watertight doors were welded on and compromised. One door was installed upside down. Conduct survey of all watertight closures; repair as necessary.
46 CFR 108.301
Condition: Improper Installation
Action required: 66 - Prior to drilling or production operations
Resolved 14 February 2019
Resolution: Visited vessel and inspected 10 watertight doors which were cut out and replaced. ABS approved installation and tested; all sat.