Records from 2012 to 2025. Most recent: inspection, 29 April 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)48.4 ft × 15.1 ft × 5.2 ft
Registered tonnagegross 35 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLITTLE HOQUIAM BOAT SHOP · HOQUIAM, WA, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORRO BAY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
23 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
29 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8126314
3 March 2025
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8088330
25 April 2024
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7902197
1 December 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7832151
21 February 2023
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7638090
9 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7633742
16 September 2022
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7563855
24 March 2022
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7410527
16 March 2021
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7147257
16 February 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7137595
4 February 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6899778
7 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6816892
19 March 2019
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6644790
17 October 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6563224
22 August 2018
Simplified Stability Test
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6542573
26 May 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6429628
19 October 2017
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6291892
24 March 2017
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6111306
20 January 2017
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6075717
1 March 2016
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5835575
6 January 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5791327
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 March 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel's dry dock examination date was overdue on 01MAR2025. Vessel is not to carry passengers until a satisfactory dry dock examination is completed.
46 CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2025
Resolved 3 March 2025
Resolution: Completed credit dry dock.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 February 2023
Resolved
In a vessel of 12 meters or more in length, but less
than 50 meters in length, a side light must be
visible at the following minimum range: 2 miles.
Vessel's port and starboard side lights were not
operable. Repair/replace to satisfaction of attending
Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 9 February 2023
Resolution: Repaired/replace to satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2023
Resolved
The owner, managing operator, or a qualified servicing
facility as applicable must conduct the following
inspections and tests: for fixed-gas fire extinguishing
systems, the inspections and tests required, in addition
to the tests required by 46 CFR 147.60 and 147.65. The
owner or managing operator must provide satisfactory
evidence of the required servicing to the marine
inspector. Satisfactory evidence of the required
servicing was not available. Provide satisfactory
evidence of the required servicing to the satisfaction
of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 9 February 2023
Resolution: Provided satisfactory evidence of the required servicing to the satisfaction of attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 February 2021
Resolved
Provide day shapes for vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 February 2021
Resolution: Day shapes provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 16 February 2021
Resolved
Provide current registration.
Vessel restricted to no more than 03 NM from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 February 2021
Resolution: Received registration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2021
Resolved
Provide covers for batteries in E/R.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 February 2021
Resolution: Batteriers covered.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 February 2021
Resolved
Provide current FF equipment service certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 February 2021
Resolution: Certificate received.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 February 2020
Resolved
Provide current and valid Certificate of Documentation.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 February 2020
Resolved 13 February 2020
Resolution: Vessel provided current COD.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 February 2020
Resolved
CO2 fixed gas firefighting system not serviced since November 2018. Provide current servicing report.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 February 2020
Resolved 13 February 2020
Resolution: Vessel provided current servicing records.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 February 2020
Resolved
Demonstrate proper operation of generator space bilge high level alarm.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 February 2020
Resolved 6 February 2020
Resolution: Vessel replaced loose connections and sent video of operating alarm.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 February 2020
Resolved
Provide DSV VHF radio programmed with current MMSI and with GPS input.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 6 February 2020
Resolution: Vessel reprogrammed MMSI and identified procedure for ensuring GPS was inputting correctly to DSC radio.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 February 2020
Resolved
Life float weak link not arranged for proper float free deployment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 6 February 2020
Resolution: Vessel re-threaded painter correctly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2020
Resolved
Provide (03) 2.5 gallon fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 6 February 2020
Resolution: Vessel provided buckets.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 February 2020
Resolved
Demonstrate proper operation of anchor light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 6 February 2020
Resolution: Vessel repaired anchor light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 February 2020
Resolved
Secure independent electric bilge pump in place in lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2020
Resolved 6 February 2020
Resolution: Vessel secured pump in place.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
An unapproved power supply strip was located plugged into an outlet at the operating station. The power strip needs to be removed from the vessel.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 5 December 2019
Resolution: Power strip removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
The 120 VAC electrical outlet near the pilot house was wired without the ground wire connected. Ensure outlets are wired with ground connected.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 5 December 2019
Resolution: Outlet wired correctly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
Wiring in engine room was not properly supported. Provide metallic supports at least every 24” on all wire runs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 5 December 2019
Resolution: Brackets installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
A non-approved extension cord was installed as a permanent wiring arrangement in the port side storage room. Remove extension cord, or replace with approved UL marine wiring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 5 December 2019
Resolution: Extension cord removed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 7 October 2019
Resolved
The life floats were stacked in tiers and not kept separated by spacers. Install spacers between life floats that are stacked in tiers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 5 December 2019
Resolution: Spacers installed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 1 March 2016
Resolved
Submit a proposal detailing permanent repairs to be made to the port aft fuel tank to this office for review and approval. Repair proposal should include post-repair hydrostatic testing of the fuel tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 30 March 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 January 2016
Resolved
Bilge alarm in accomodation space was inoperable and needs to be replaced.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2016
Resolved 12 January 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 January 2016
Resolved
02 Alcohol testing strips were expired and needs to be replaced.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2016
Resolved 12 January 2016
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 January 2016
Resolved
Pubs are out of date and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2016
Resolved 12 January 2016