Inspection record

Last inspected 23 May 2026
…with no type recorded59
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7907984
Flag
UNITED STATES
Maury page id
psix-54148

Documentation record

Registered dimensions (L × B × D)811.7 ft × 105.8 ft × 66.0 ft
Registered tonnagegross 40,627 / net 31,126
ITC dimensions (L × B × D)811.7 ft × 105.8 ft × 66.0 ft
ITC tonnagegross 41,036 / net 12,310
BuilderAVONDALE SHIPYARD · AVONDALE, LA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 28 November 2025 · expires 30 November 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35101 - Dead Weight, Ton
41036 - Convention (Subpart B), Gross Ton
40627 - Regulatory (Subpart C or D), Gross Ton
12310 - Convention (Subpart B), Net Ton
31126 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 167 inspections, each with its date, unit and type; 61 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DANNY G Passenger (Inspected) · MISLE 54264 · 12 July 2019 · activity 6792662HEIDI L BRUSCO Towing Vessel · MISLE 54742 · 12 July 2019 · activity 6792662

Inspection history · 167

23 May 2026 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8391460
18 May 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8378182
23 January 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8300796
18 December 2025 Vessel Attendance · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8281741
22 October 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8258498
21 October 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8259627
14 September 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8234111
6 August 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8203510
6 August 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8204576
5 August 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8203319
31 July 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8205051
24 April 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8102974
15 February 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8079862
3 February 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8074111
18 July 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7960962
18 July 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7966426
29 June 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7946801
18 May 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7921735
30 April 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7904256
29 April 2024 MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875597
3 April 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7889692
26 March 2024 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7850773
4 March 2024 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7873503
21 November 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7828448
28 August 2023 Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7741512
6 August 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7825589
27 July 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7764285
21 July 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7824773
4 July 2023 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7750361
26 April 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7688187
27 March 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7657743
20 March 2023 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7654261
3 March 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7645041
23 February 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7644802
13 February 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7636215
2 February 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7630802
3 January 2023 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7615905
20 December 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7611556
7 December 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7605934
28 November 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7600837
7 November 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7591047
28 October 2022 Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7585693
25 October 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7583409
10 October 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7574649
13 September 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7558297
31 August 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7547953
16 August 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7535138
23 July 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7514010
22 July 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7518685
18 July 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7510520
8 July 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7500795
8 July 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7500903
7 July 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7505174
23 June 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7484909
6 June 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7470438
31 May 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7464192
14 May 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7446859
25 April 2022 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7437766
18 April 2022 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7424839
11 April 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7454873
31 March 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7422234
28 February 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7403370
27 January 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386977
18 January 2022 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7381999
4 January 2022 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7375536
22 December 2021 Deficiency Check · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7371755
20 December 2021 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7370924
15 December 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7369983
22 November 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7356082
8 November 2021 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7347496
25 October 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7339575
14 October 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7332906
13 October 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7332326
12 October 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7331462
13 September 2021 Explosive Handling Operation-Administrative · Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7311422
4 September 2021 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7300450
2 August 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7275395
20 July 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7262483
6 July 2021 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7247537
19 June 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7229715
19 June 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7250929
24 May 2021 Explosive Handling Operation-Commercial · Explosive Handling Operation-Administrative
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7205926
10 May 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7193952
27 April 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7184214
24 April 2021 Re-Inspection · ACP COI Oversight · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7178790
12 April 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7174000
29 March 2021 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7164890
25 March 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7163649
24 March 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7179969
28 December 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7116792
20 October 2020 ACP Annual Oversight · ACP Additional Oversight – Risk Assessment · Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7081279
2 September 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7048776
2 September 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7105987
7 July 2020 Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6999130
3 July 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6994118
26 June 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6987893
24 June 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6986962
20 May 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6965406
28 April 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6945410
25 March 2020 Administrative Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6931184
17 March 2020 Commercial Dive Inspection · Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6928003
11 March 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6933249
19 February 2020 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6912110
3 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6882433
3 January 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6972426
2 January 2020 Periodic Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6852196
30 December 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6880740
30 September 2019 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6823966
12 August 2019 ACP Additional Oversight – Risk Assessment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6781685
30 July 2019 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6767083
12 July 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6792662
9 July 2019 Deficiency Check · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6744623
16 April 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6663251
12 April 2019 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6660951
18 March 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6644600
4 February 2019 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6619718
20 December 2018 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600559
12 December 2018 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6596760
3 November 2018 ACP Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6582221
23 October 2018 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6567024
9 October 2018 Explosive Handling Operation-Administrative
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6557867
29 September 2018 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552469
28 September 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6554866
24 September 2018 Explosive Handling Operation-Commercial
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6547623
11 September 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6538357
15 August 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6513315
31 July 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6496992
19 July 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6484454
3 July 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6465545
18 June 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6448233
17 June 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6456537
5 June 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6435291
26 May 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6419686
25 May 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6425591
14 May 2018 ACP Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6410502
14 May 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6427466
7 May 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6408063
24 April 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6398762
10 April 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6388819
7 April 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6388121
28 March 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6380776
22 February 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6443519
15 February 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6356012
30 January 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6346538
16 January 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6338759
29 December 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6330281
18 December 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6326094
20 November 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6310162
27 October 2017 ACP COI Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6294329
23 October 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6293518
21 October 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6293730
11 October 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6285869
26 September 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6275674
11 September 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6264614
23 June 2017 Periodic Inspection · Damage Survey · ACP Periodic Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6182641
14 June 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6177997
13 March 2017 Hull Examination · Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6103494
10 December 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6056753
5 December 2016 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6052739
13 November 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6040102
21 October 2016 ACP Annual Oversight · Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6021653
1 October 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6014867
13 September 2016 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6000493
6 September 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6001994
16 July 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5945412
15 July 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6018267
26 February 2016 ACP Periodic Oversight · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5824291

Deficiency record · 61

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 December 2025 No resolution recorded
Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm set points, the procedure to be followed, and the expected test result. The vessel's approved PSTPs do not match the onboard testing procedures needed to properly demonstrate the functionality of the required automation. Rectify prior to next USCG Annual Inspection. 46 CFR 8.440(a)
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2025 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Vessel reported a loss of Main Engine control both ahead and astern. Vessel shall make necessary repairs to the satisfaction of the attending class surveyor. 74 SOLAS (20) II-1/ 26.3
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2025
Resolution: Received satisfactory Preliminary Class Report for vessel. Vessel replaced Astern Reverse Servo Position Sensor and conducted a satisfactory operational test of ahead and astern bells, which indicated full control of the system. Class Surveyor attested to
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 April 2024 Resolved
The arrangements provided shall be such as to ensure the safety of the ship in all sailing conditions, including maneuvering, is equivalent to that of a ship having the machinery space manned. MI was notified that the vessel’s machinery space fire detection system is not fully operational due to planned system upgrades. Vessel is required to maintain a 24 hour fully manned engine room until the detection system is installed and the functionality of the system is verified.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 10 May 2024
Resolution: Received ABS report commissioning fire detection. Added to documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 26 March 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that appropriate corrective action is taken. During annual inspection, MI discovered 68 overdue engineering and 20 overdue deck maintenance items. A Safety Management Audit carried out by the RO is required within 30 days. SOLAS (01) COND. CH. IX/REG 03 ISM CODE: REG 10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 6 May 2024
Resolution: Received Preliminary Audit Report from ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 March 2023 Resolved
Fire doors in stairtower enclosures, other than power operated watertight doors and those which are normally locked, shall be of the self closing type capable of closing against an inclination. Stairtower door in vicinity of lower paint locker was found to have a hold back. 74 SOLAS II-2/23
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 20 April 2023
Resolution: Rectified to the satisfaction of the attending Class surveyor; Finding No. 248. Hold back was removed and door returning to normal operating capacity.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. External light on port side of machinery bulkhead outside EDG space is not properly secured. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 17 April 2023
Resolution: ABS accepted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons. Battery charging panel cover in battery room below EDG found secured with duct tape. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 3 April 2023
Resolution: Battery charging panel cover in battery room below EDG was permanently repaired to the satisfaction of the attending Surveyor [name withheld] No. 2482.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 March 2023 Resolved
The ship shall be provided with fire pumps complying with the following requirements: In a ship of 2,000 tons gross tonnage and upwards, this alternative means shall be a fixed emergency fire pump. This emergency pump shall be capable of supplying two jets of water. Observed pinhole leak on emergency fire pump recirculation piping. 74 SOLAS II-2/52
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 17 April 2023
Resolution: ABS accepted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. No signage was installed on or near the watertight door from ER to the shaft alley indicating to keep closed. 74 SOLAS (20) I/11
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 17 April 2023
Resolution: ABS accepted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Light in the lower paint locker was missing a protective metal guard. 74 SOLAS (20) I/11
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 3 April 2023
Resolution: Light permanently repaired to the satisfaction of the attending Surveyor [name withheld] No. 2485.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. Emergency lights in EDG space insufficient to illuminate the emergency generator switchboard. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 17 April 2023
Resolution: ABS accepted.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 March 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons. General alarm contactor housing in EDG space observed to have broken glass cover. 74 SOLAS (20) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 17 April 2023
Resolution: ABS accepted.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 March 2023 Resolved
In all new and existing ships, fire extinguishing appliances shall be kept in good order and available for immediate use at all times during the voyage. Gaylord ventilation damper was overdue for servicing and last serviced in November of 2021. 74 SOLAS II-2/15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 3 April 2023
Resolution: Gaylord ventilation damper was serviced by "GFS" and re-inspected to the satisfaction the attending Surveyor [name withheld] No. 2488
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 20 March 2023 Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. Three gas meters onboard are being bump tested at 30 day intervals and calibrated annually. Safety management system onboard states personnel will use properly calibrated meters and the manufacturer’s instructions shall be strictly followed. Manufacturer’s instructions state meters should be bump tested prior to each use and calibrated every 6 months. ISM Part A/7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2023
Resolved 3 April 2023
Resolution: Manufacturer's instructions for gas meter testing were implemented and verified to the satisfaction of the attending Surveyor [name withheld] No. 2489.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 March 2023 Resolved
In all new and existing ships, fire extinguishing appliances shall be kept in good order and available for immediate use at all times during the voyage. Firehose on port bridgewing was leaking in two locations during operational test. Hose replaced. 74 SOLAS II-2/15
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 April 2023
Resolved 20 March 2023
Resolution: Firehose replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 31 October 2022 Resolved
A person may not employ or engage an individual, and an individual may not serve in a position in which it is required by law or regulation that the individual hold an MMC endorsed with a national endorsement, as well as a cooresponding STCW endorsement for service outside hte boundary line. Able bodied seaman in a watch standing billet found without endorsement for AB Deck or RFPNW nor Basic Safety.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2022
Resolution: An appropriately credentialed mariner was sourced and signed on the vessel to fill the AB position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2022 Resolved
Main engine auto start valve stuck and needed local control. Prove proper operation. 46 CFR 58.01-35
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2022
Resolution: ABS Finding # 2445.0
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 October 2021 Resolved
Fire hydrants must be of sufficient number and so located that any part of the vessel accesible to persons on board while the vessel is being navigated and all cargo holds may be reached with at least 2 streams of water from separate outlets. Two fire stations on the 3rd deck (protecting the tank top area/storage space, potable water room, and MSD room) do not receive fire main pressure due to a blockage in the fire main. 46 CFR 95.10-10
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2021
Resolved 16 October 2021
Resolution: Received Authorized Classification Society (ACS) report attesting to the clearing of blocked fire main hydrants.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 April 2021 Resolved
All the life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. The port lifeboat internal lowering activation handle does not activate the lowering of the lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2021
Resolution: Received ABS class survey report showing correction of internal lowering activation handle and two successful operational tests.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2021 Resolved
All the life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. The length of line attaching the port and starboard bridge lifebuoys to the smoke float is not sufficient to produce the momentum required to release the smoke float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 7 May 2021
Resolution: It was verified both port and starboard bridge wing life buoys' attached smoke signals were fitted with length of rope per OEM- min 13 feet and considered satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 April 2021 Resolved
All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Several accommodation fans are not installed in an appropriately permanent manner.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 7 May 2021
Resolution: The accommodation fan in the identified staterooms was examined and considered satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The supply fan above the purifier controller is clogged and requires servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 7 May 2021
Resolution: Ventilation screens in Engineroom purifier room were cleaned and free from debris, examined, and considered satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 April 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The fasteners holding the vent filter of the AC supply fan on the lifeboat deck port side are rusted and require replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 7 May 2021
Resolution: Air conditioning screen fasteners were renewed at this time, corrosion arrested and considered satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 October 2020 Resolved
72COLREGS, Rule 30: A power driven vessel anchored shall exhibit a anchor light. Repair broken stern anchor and prove operation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 January 2021
Resolved 31 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2020 Resolved
74 SOLAS (14) CHPT II-1/40.1.3: Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. Replace missing dead front cover for electrical circuit breaker panel 2-92-2 ; located just before heading down ladder to steering gear room and missing electrical cover to outlet in reefer shop on main deck aft port side.
Action required: 705 - Other - as specified
Due 26 January 2021
Resolved 31 January 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 October 2020 Resolved
74 SOLAS (14) CHPT III, Reg. 6.4.3: Each general emergency alarm signal must be an electronically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. Repair inoperable General Alarm Bell: Steering gear room, #119 & 120 forward upper engine room, #128 engine room boiler, bell numbers #70 and #55 inside the house and in forward bosun locker lower flat.
Action required: 705 - Other - as specified
Due 26 January 2021
Resolved 31 January 2021
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 21 October 2020 Resolved
74 SOLAS (14) CHPT II-1, Reg. 38: An engineer’s alarm shall be provided to be operated from the engine control room or at the maneuvering platform as appropriate, and shall be clearly audible in the engineers’ accommodation. Repair inoperable General Alarm Red Light: Steering gear room, Between #2 & 3 Generators, forward engine room lower level.
Action required: 705 - Other - as specified
Due 26 January 2021
Resolved 31 January 2021
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 21 October 2020 Resolved
74 SOLAS (14) CHPT III, Part B, Reg. 6.4.1: An emergency means compromised of either fixed or portable equipment or both shall be provided for two-way communications between emergency control stations, muster and embarkation stations and strategic positions on board. Repair inoperable anallog phone in forward bosun locker on lower flat.
Action required: 705 - Other - as specified
Due 26 January 2021
Resolved 31 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 October 2020 Resolved
74 SOLAS (14) CHPT III, Reg. 20.2: Before the ship leaves port and at all time during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Six person liferaft on starboard side was inspected with the painter line connected to shackle versus weak link. Corrected by the crew member.
Action required: 10 - Deficiency Rectified
Resolved 21 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel's experienced no-start failure of main engine while getting underway from California due fault in the start air system. System was repaired but CG was not notified until after the vessel departed. Repairs must be verified by ABS prior to departure from Honolulu, HI. 74 SOLAS (14) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2020
Resolved 29 June 2020
Resolution: ABS report recieved attesting to repairs. Report uploaded in documents.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 2 January 2020 Resolved
The condition of the vessel shall be maintained IAW its surveyed condition. Cell block stays in cargo bay 2 shall be surveyed and repaired as per installation design. Cell stays in bay 02 were not under tension and turn buckles not secured on multiple stays.
Action required: 705 - Other - as specified
Due 5 February 2020
Resolved 22 January 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 August 2019 Resolved
Machinery driving oil fuel transfer pumps shall be fitted with remote controls situated outside the space concerned so that they may be stopped in the event of a fire arising in the space in which they are located. Emergency stop for diesel oil transfer was corroded and inoperable, prove operational prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2019
Resolution: ABS Report: The remote emergency stop push button switches at the port and starboard bunkering manifold locations were replaced, tested, and considered satisfactory as a permanent repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 12 August 2019 Resolved
Discharges led through the shell either from spaces below the freeboard deck or from w/in superstructures and deck houses on the freeboard deck shall be fitted w/efficient and accessible means for preventing water from passing inboard. The means for operating the positive action valve from above the freeboard deck shall be readily accessible. Drainwell steward stores port remote shutoff was disconnected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 13 August 2019
Resolution: Accepted by ABS with a due date of 26AUG19: ABS Report: It is recommended that the aforementioned deficiency be rectified to the satisfaction of the next attending surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 12 August 2019 Resolved
Design verification and periodic safety test procedures are to be submitted for approval and retained on board the vessel. Test procedure documents must be in a step by step or checklist format. Each test instruction must specify equipment status, apertures' necessary to perform the tests, safety precautions, safety controls and alarm set points, the procedures to the followed, and the expected test results. Found numerous edits and revisions to PSTP's. Submit revisions to class for approval. ABS U.S. Supplement for SVR cert for intl. voyage Section 1 CITE 4-9-1/7.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 16 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 August 2019 Resolved
All metal sheaths and armor of cables shall be electrically continuous and earthed. Splice in aft steering overhead needs to prove continuity of metal sheathing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2019
Resolved 16 August 2019
Stability › Unintentional Flooding › General
Issued 14 May 2018 Resolved
Parts penetrating the shell plating below the deepest subdivision draught shall be fitted with a watertight sealing arrangement. Replace nuts for securing ventilation to purifier room. 74 SOLAS unamended II-1/15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 3 June 2018
Resolution: Securing nuts replaced to the satisfaction of ABS, see report 1924 HL3506102-A
Construction/Loadline › Penetrations › Weld
Issued 14 May 2018 Resolved
07120; Parts penetrating the shell plating below the deepest subdivision draught shall be fitted with a watertight sealing arrangement. Escape hatch for hold #4 has a hole. Make permanent repair.74 SOLAS unamended II-1/15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 3 June 2018
Resolution: Weld repair completed to the satisfaction of ABS, see report 1926 HL3506102-A
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 May 2018 Resolved
11117; Before the ship leaves port, all life saving appliances shall be in working order and ready for immediate use. Add throw-line to ring buoy on fantail. 74SOLAS(14)III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Fire Fighting › Structural - A Class Divisions › Doors
Issued 14 May 2018 Resolved
07105; Thermal and structural boundaries are required to contain, control, and supress fire and explsion in the compartment of origin. Renew metal shutter in galley to meet fire boundary per fire control plan. 74 SOLAS unamended II-2/2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: New latches installed to the satisfaction of ABS. Report 1929 SF3509901-B
Construction/Loadline › Structures › Scuttle
Issued 14 May 2018 Resolved
07120; Two means of escape are required from shaft alley. Shaft alley escape scuttle found seized and had a weakened spring which would not hold it open. Crew shall make the scuttle readily accessible as a means of escape. 74SOLAS CH II-2 Reg.53(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Escape scuttle spring corrected to the satisfaction of ABS. Report 1931 SF3509901-B
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 May 2018 Resolved
07120; Escape paths shall lead to embarkation deck. Means of escape from the shaft alley was found obstructed with a length of fire hose and had inoperable emergency lights rendering the path hard to access. Crew shall repair lights and remove the fire hose. 74SOLAS CH II-2 Reg.53(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Escape path cleared/lighted to the satisfaction of ABS. Report 1931 SF3509901-B.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 14 May 2018 Resolved
03108; Watertight trunks shall be of the same strength as watertight bulkheads at the corresponding levels. Main deck vent trunk found fractured at its joint with the deck. Crew shall repair the trunk to deck connection to ensure it is watertight. 74 SOLAS CH II-1 Reg. 17
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 3 June 2018
Resolution: Welded repair completed to the satisfaction of ABS, see report 1933 HL3506102-A
Construction/Loadline › Penetrations › Weld
Issued 14 May 2018 Resolved
02116; Vessel shall maintain compliance with structural arrangements as originally surveyed. Vessel found with minor fracture of horizontal longitudinal frame in the aft port corner of the second engineering flat just outboard of the topping air compressor. Repair fracture. 74 SOLAS CH I Reg. 11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 14 June 2018
Resolution: Weld repair completed to the satisfaction of ABS, see report SF3496175-D
Engineering › Pressure Vessel › Marking and Stamping
Issued 14 May 2018 Resolved
09210; Vessels ship service air receiver found with no data plate and painted over relief valve. Vessel shall provide data plate and make legible the relief valve information. 74 SOLAS CH I Reg. 11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: New data plate provided to the satisfaction of ABS. Report 1935 SF3509901-B.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 May 2018 Resolved
09209; Vessels crew shall be protected from electrical hazards. Multiple open front/ open back electrical distribution panels found in aft steering with bare steel decking adjacent. Vessel shall provide non conductive matting around working areas. 46 CFR 111.30-1(c) (pre 82' build rules)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Steel deck covered to the satisfaction of ABS. Report 1937 SF3509901-B
Engineering › Fuel Oil Service System › Piping
Issued 14 May 2018 Resolved
13101; High pressure fuel oil lines are to be suitably designed and insulated. No. 9 cylinder fuel injector supply line found gouged through the outer jacket wall. Provide renewal line meeting the applicable design requirements. 74 SOLAS CH I Reg. 11
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2018
Resolved 14 May 2018
Resolution: Line replaced with ship spare and verified by ABS, see report SF3496175-D
Construction/Loadline › Hull › Weld
Issued 14 May 2018 Resolved
02116; Vessel shall maintain compliance with structural arrangements as originally surveyed. Vessel found with two fractures at the bulwark attachment to the port tunnel ventilation trunk just forward of the house. 74 SOLAS CH I Reg. 11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Fractures were repaired to the satisfaction of ABS. Report 1939 SF3509901-B
Fire Fighting › Fire Hydrants › Condition
Issued 14 May 2018 Resolved
07109; No change may be made in structural arrangement, equipment, and other items covered by the survey. Valves at fire station on port wing and at stations 25 and 27 were leaking. 74SOLAS(14)1/11a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Valves were replaced in kind to the satisfaction of ABS. Report 1908 SF3509901-B
Fire Fighting › Structural - A Class Divisions › Doors
Issued 14 May 2018 Resolved
07123; Thermal and structural boundaries are required to contain, control, and supress fire and explsion in the compartment of origin. Demonstrate closure of fire doors throughout stairwells. Fire doors surrounding galley shall be made self closing. 74 SOLAS unamended II-2/2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Doors corrected to the satisfaction of ABS. Report 1911 SF3509901-B
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 May 2018 Resolved
02108; Thermal and structural boundaries are required to contain, control, and supress fire and explsion in the compartment of origin. Renew multi-cable transit in electricians storage closet on upper deck to approved standard. 74 SOLAS unamended II-2/2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 9 July 2018
Resolution: 2 of 3 MCT's corrected to the satisfaction of class, 3rd MTC issued extension until 13 July 18. Report 1957/1958 SF3509901-B. SF3524224-B provided by ABS clearing last remaining MCT.
Fire Fighting › Combustible Materials › Stowage
Issued 14 May 2018 Resolved
09102; Ignition sources and combustible materials shall be restricted. Remove flammable materials and excess materials from engineers change room. 46 CFR 147.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 3 June 2018
Resolution: Excess materials removed and verified by ABS, see report 1946 HL3506102-C
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 May 2018 Resolved
06103; The arrangements and efficiency of means for closing any opening shall be consistent with its intended purpose. Renew all broken or missing cotter pins on deck/cargo hatches. 74 SOLAS unamended II-1/15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Cotter pins renewed to the satisfaction of ABS. Report 1914 SF3509901-B
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 May 2018 Resolved
11117; Before the ship leaves port, all life saving appliances shall be in working order and ready for immediate use. Replace retro reflective tape on ring buoys with paint on them. Ensure ring buoys properly labeled. 74SOLAS(14)III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: OSD 1916 SF3496175-C
Fire Fighting › Combustible Materials › Stowage
Issued 14 May 2018 Resolved
99101; Cylinders must always be secured and when not in use, stowed in a rack in an upright position. Properly stow all compressed cylinders that are on reefer flat forward of galley. 46 CFR 147.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 3 June 2018
Resolution: Compressed cylinders were properly stowed and verified by ABS, see report 1917 HL3506102-A
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 14 May 2018 Resolved
07108; Fire protection systems and appliances shall be maintained ready for use. Replace missing hammer for remote shut down break glass outside galley. 74SOLAS(14)II-2/14
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 3 June 2018
Resolution: Hammer replaced and verified by ABS, See report 1919 HL3506102-B
Deck/Cargo › Cargo Transfer (solid) › General
Issued 14 May 2018 Resolved
06107; No change class be made in structural arrangement, equipment, and other items covered by the survey. Renew cracked support welds on forward starboard crane. 74 SOLAS 1/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 3 June 2018
Resolution: Weld repairs completed to the satisfaction of ABS, see report 1943 HL3506102-D
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 May 2018 Resolved
03105; The arrangements and efficiency of means for closing any opening shall be consistent with its intended purpose. Renew fractured foundations on hatch dogs 8&20. 74 SOLAS unamended II-1/15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Foundations repaired to the satisfaction of ABS. Report 1920 SF3509901-B
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 May 2018 Resolved
03105; Parts penetrating the shell plating below the deepest subdivision draught shall be fitted with a watertight sealing arrangement. Replace missing landing pads for hatch covers. 74 SOLAS unamended II-1/15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Landing pad was replaced to the satisfaction of ABS. Report 1922 SF3509901-B
Lifesaving › Launching Appliances › Falls
Issued 27 October 2017 Resolved
While lowering the port lifeboat, observed lack of maintenance (grease/slush) on both the fore and aft falls. The chief mate indicated one of the falls was damaged at its recent drydock in China. No documenation or proof was found. Also, the crew could not produce the lifesaving appliance manual cover the newly installed lifeboats.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 26 December 2017
Resolution: Received satisfactory ABS report from attending surveyor for the falls renewal and dynamic 1.1% dynamic weight test.
Lifesaving › Lifebuoys › Serviceable
Issued 27 October 2017 Resolved
Replace wasted grab lines on 05 lifebuoys on main deck.
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 11 November 2017
Resolution: Grablines were replaced as required.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 13 September 2016 Resolved
There is a 2 inch crack between 3S Wing MGO tank and 3C double bottom ballast tank. Vessel shall make satisfactory repairs prior to loading fuel into the 3S fuel oil tank
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 September 2016
Resolution: Repair to fuel tank cleared via class society report