MAURY USCG vessel records Sign in
← All vessels

DANNY G

DANNY G is a 1982 passenger vessel (inspected). The Coast Guard has recorded 92 inspections since 1982, most recently in January 2026, along with 129 deficiencies, 8 operational controls and 3 casualty investigations between 2010 and 2019.

Records from 1982 to 2026. Most recent: inspection, 30 January 2026.

Built
1982
Last inspected
30 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK2438
Flag
UNITED STATES
368035480
Maury page id
psix-54264

Inspections, by type

…with no type recorded11
Years with a record 38 calendar years (1982–2026)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portOAKLAND, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK2438MMSI 368035480 · active · compulsorily equipped · granted 2 May 2018, expires 2 May 2028
WDD3436MMSI 367131320 · expired · compulsorily equipped · granted 3 May 2016, cancelled 29 August 2026
WDA4576MMSI 366810920 · expired · compulsorily equipped · granted 11 May 2001, cancelled 16 July 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MANOA Freight Ship · MISLE 54148 · 12 July 2019 · activity 6792662HEIDI L BRUSCO Towing Vessel · MISLE 54742 · 12 July 2019 · activity 6792662

Inspection history · 92

30 January 2026 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8299748
26 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8009393
29 August 2024 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7991933
5 April 2024 Simplified Stability Test · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7890684
20 September 2023 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7794447
12 April 2023 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7667503
3 April 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7662096
1 December 2022 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7602910
31 August 2022 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7547013
26 April 2022 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7438374
15 April 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7431822
1 September 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7047958
16 April 2020 Internal Structural Exam · COI Inspection · Drydock Extension · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6939871
12 July 2019 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6792662
25 April 2019 Damage Survey · Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6642461
5 February 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6620126
4 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6554574
16 July 2018 Deficiency Check · Internal Structural Exam · Damage Survey · Drydock Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6481812
16 July 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6496665
26 April 2018 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6403208
27 December 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6318090
27 December 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6332593
27 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6313289
3 November 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6300520
10 January 2017 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6068613
13 July 2016 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5923866
17 August 2015 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5218873
5 August 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4923210
13 July 2011 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4062835
30 November 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3898295
4 November 2010 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3885177
22 September 2010 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3855177
16 March 2010 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3696993
21 January 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3398016
28 November 2008 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3348382
17 July 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3270966
26 July 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2993629
12 July 2007 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2992815
30 May 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2930584
27 July 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2727088
24 July 2006 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2690990
14 December 2005 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2551309
28 June 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2406367
26 May 2005 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2322495
25 April 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2322498
21 August 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2172135
20 August 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2171883
5 September 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1897657
27 August 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1883191
2 July 2003 Plan Review "T" Boat · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1833043
18 June 2003 Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1792122
26 May 2002 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1620992
24 May 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1065250
24 May 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393683
27 April 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413930
3 August 2000 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 821335
19 May 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1384444
25 May 1999 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451412
26 January 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1127809
3 June 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1419971
28 November 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1120793
4 September 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 785529
5 August 1997 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 782810
19 May 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406117
8 May 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1105739
12 February 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406121
23 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 215509
29 February 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419557
24 November 1995 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428547
9 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191250
10 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 836037
28 January 1993 Inclining Experiment · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 831375
17 November 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141796
16 July 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267096
30 June 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665595
29 June 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961081
11 February 1992 Hull Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943279
4 February 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258570
26 April 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930709
21 March 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230841
17 November 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923402
26 October 1989 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321318
9 February 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1342785
27 September 1988 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044179
28 January 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1016493
20 February 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320633
6 October 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317224
23 October 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293067
27 September 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296976
8 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983738
5 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973247
1 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275526

Deficiency record · 129

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 September 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed expired aspirin, rectify valid contents to MI satisfaction. 46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 2 October 2024
Resolution: Operator procured valid aspririn to MI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 September 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Paddles were not labeled, rectify to MI satisfaction. 46 CFR 185.604(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 2 October 2024
Resolution: Operator labelled lifefloat paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 September 2024 Resolved
Each survival craft required on a vessel by this part must meet the following: For a life float-Approved under approval series 160.027... Each life float must meet the requirements in subpart 160.010 of this chapter...Each buoyant apparatus must have Type II retroreflective material... MI observed faded retroreflective tape on vessel lifefloats, replace to MI satisfaction. 46 CFR 180.200(2) 46 CFR 160.207-2 46 CFR 160.010-4(p)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 2 October 2024
Resolution: Operator replaced lifefloat retroreflective tape.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 20 September 2023 Resolved
No person may operate an oceangoing ship of less than 400 gross tons, unless it either:Has the capacity to retain on board all oily mixtures and is equipped to discharge these oily mixtures to a reception facility...Oil was discharged when the crew activated the fixed bilge system. Operator shall clean and service bilge system to the satisfaction of the Marine Inspector. 33CFR 155.350(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 September 2023
Resolved 21 September 2023
Resolution: Operator cleaning bilge system and proved functionality of system.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 September 2023 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following…Inspection of piping, controls, and valves, and the inspection and testing of alarms and ventilation shutdowns…to determine that the system is in operating condition… Starboard engine room ventilation damper does not close properly, repair damper to the satisfaction of the Marine Inspector. 46 CFR 176.810(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 29 September 2023
Resolution: Attended vessel and confirmed proper ooperation of fire damper
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray.... Generator battery is stored under the generator, battery storage lid does not fit properly and allows oil to drip onto the battery. Make repairs to battery lid to the satisfaction of the Marine Inspector. 46 CFR 183.350(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 29 September 2023
Resolution: Attended vessel and confirmed appropriate repair to battery lid.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 September 2023 Resolved
Each hydrostatic release unit must be serviced, within 12 months of its manufacture and within 12 months of each subsequent servicing…. Hydrostatic release on the EPIRB is expired replace or service. 46 CFR 185.740(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 29 September 2023
Resolution: Attended vessel and confirmed new installation of hydro release.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 September 2023 Resolved
The master of the vessel shall ensure that: Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative...The EPIRB test required by paragraph (a) shall be logged or otherwise documented.. conduct and log EPIRB tests. 46 CFR 185.728(a)(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 29 September 2023
Resolution: Witnessed testing of the EPIRD and new log book/entry
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023 Resolved
All cable and wire must.. Be installed with metal supports spaced not more than 24 inches apart. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support….cable run in center void is supported by plastic ties, replace with metallic supports. 46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 29 September 2023
Resolution: Attended vessel and confirmed installation of metallic supports.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 September 2023 Resolved
A hatch exposed to the weather must be watertight….Port engine room and lazarette gaskets are deteriorated, replace gaskets. 46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 29 September 2023
Resolution: Attended vessel and confirmed installation of new hatch gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure… Port ammeter is plugged into an unprotected outlet, install appropriate cover. 46 CFR 183.340(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 29 September 2023
Resolution: Ammeter no longer in use, will submit plans to hardwire at next dry dock/repower
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023 Resolved
A portable or temporary electrical cord or cable must be constructed and used in compliance with the requirements of 46 CFR 111.60-13.. Battery chargers for port and starboard main engines are plugged into an outlet, submit electrical plans to hardwire system during next credit dry dock or repower whichever comes first. 46 CFR 183.340(r)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2023
Resolved 26 September 2024
Resolution: Verified installation of battery charger and electrical plans.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2023 Resolved
Battery chargers must have an ammeter connected in the charging circuit… Starboard battery charger does not have an ammeter, submit electrical installation plans for OCMI review and install during next credit dry dock or repower which ever comes first. 46 CFR 183.350(f)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2023
Resolved 26 September 2024
Resolution: Verified electrical installation plans and sat installation.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 September 2023 Resolved
Any time passengers are embarked on a passenger vessel, the vessel must have the crew complement required by the COI, whether the vessel is underway, at anchor, made fast to shore, or aground. However, the master may allow reduced crew for limited or special operating conditions subject to the approval of the OCMI…. Vessel operators do not have a near coastal endorsement per COI route requirements. Company to provide exemption request based on vessel area of operation. 46 CFR 15.515(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2023
Resolved 27 September 2023
Resolution: Operator submitted formal request, letter in documents tabs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2023 Resolved
The inspection shall be such as to ensure that the vessel, as regards the structure and piping, is in satisfactory condition and fit for the service for which it is intended. The structural integrity of the piping for the port main engine raw water intake is compromised. Submit plans for repairs and conduct repairs to the satisfaction of the attending Marine Inspector. 46 CFR 176.05-10(a) "OLD T"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 14 April 2023
Resolution: Received satisfactory evidence of temporary repairs.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 April 2023 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. There are open cable transits in the starboard forward machinery bulkhead. Make repairs to the satisfaction of the attending Marine Inspector. 46 CFR 177.405(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 14 April 2023
Resolution: Received satisfactory evidence of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2023 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that: the pump is permanently mounted. The electric bilge pump in the machinery space is not permanently mounted. Make repairs to the satisfaction of the attending Marine Inspector. 46 CFR 182.520(e)(3)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 14 April 2023
Resolution: Received satisfactory evidence of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. There are new cables in the machinery space that are not properly supported. Make repairs to the satisfaction of the attending Marine Inspector. 46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 14 April 2023
Resolution: Received satisfactory evidence of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 April 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Restricted within 3NM of shore until rectified. 46 CFR 180.64
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 April 2023
Resolution: Received satisfactory evidence of new registration.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 April 2023 Resolved
No more than 19 liters (five gallons) of flammable liquids may be stowed in any machinery space. The flammable liquids must be in containers of 3.8 liters (one gallon) or less. There were multiple containers over one gallon that exceeded the five gallons of permitted storage of flammable liquids in the machinery space. Remove excess flammable liquids to the satisfaction of the attending Marine Inspector. 46 CFR 147.45(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 April 2023
Resolution: Removed in the presence of the attending Marine Inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2023 Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for annual inspection. Resolve prior to carriage of passengers. 46 CFR 176.500 (b)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 April 2023
Resolution: Conducted satisfactory annual inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2022 Resolved
All electrical equipment and circuits must be clearly marked and identified. The vessel had multiple circuits in the circuit breaker that were not properly labeled. 46 CFR 183.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 5 May 2022
Resolution: Vessel operator sent photos of the labeled circuit breaker.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 April 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The vessel was missing the ammonia inhalants inside their first-aid kit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 5 May 2022
Resolution: Receieved photos of the newly purchased first-aid kit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2022 Resolved
A vessel not required to have a power driven pump must have at least three 2.5 gallon buckets. The vessel had two fire buckets onboard. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 5 May 2022
Resolution: Received photos of the firebuckets.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 April 2022 Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing of the vessel. The vessel had multiple cracks within the main void below the pilothouse which should be addressed in the next drydock inspection. 46 CFR 176.610(b)
Action required: 705 - Other - as specified
Due 26 May 2022
Resolved 31 August 2022
Resolution: Cracks in the locations listed were not found. Possibly repaired since initially issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 April 2022 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached. The vessel's second lifefloat was not affixed to the vessel. 46 CFR 180.130(a)(1)
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: The second lifefloat was affixed to the vessel on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 April 2022 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Vessel missing stability letter onboard. 46 CFR 176.306
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Vessel posted the stability letter at the operating station.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 April 2022 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel is seven months past COI anniversary date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2022
Resolution: Underwent successful annual inspection.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 1 September 2020 Resolved
A VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMENTS FOR ANY RADIO AND EPIRB INSTALLATIONS, INCLUDING THE REQUIREMENTS FOR CERTIFICATES TO BE ISSUED BY THE FCC, AS SET FORTH IN 47 CFR 80. VESSEL'S MASTER DID NOT HAVE A FCC MARINE RADAR OPERATOR PERMIT. 46 CFR 184.502
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2020
Resolution: Captain provided marine radio operator permit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 September 2020 Resolved
A VESSEL MUST BE PROVIDED WITH BILGE PUMPS IN ACCORDANCE WITH TABLE 182.520(a). VESSEL'S BILGE PUMP WAS UNABLE TO MEET THE 10 GAL/MIN STANDARD SET FORTH IN TABLE 182.520(a). 46 CFR 182.520
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2020
Resolution: Witnessed satisfactory operation of bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 1 September 2020 Resolved
LIFE FLOATS AND BUOYANT APPARATUS MUST NOT BE STOWED IN TIERS MORE THAN 4 FEET HIGH. WHEN STOWED IN TIERS, THE SEPARATE UNIT MUST BE KEPT APART BY SPACERS. VESSEL'S LIFE FLOATS WERE STACKED IN TIERS WITHOUT SPACERS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 9 September 2020
Resolution: Spacers in place for life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 September 2020 Resolved
EACH CHILD SIZE LIFE JACKET MUST BE STOWED IN A LOCATION THAT IS APPROPRIATELY MARKED AND SEPARATED FROM ADULT LIFE JACKETS SO THE CHILD SIZE LIFE JACKETS ARE NOT MISTAKEN FOR ADULT LIFE JACKETS. CHILD SIZE LIFE JACKETS WERE NOT SEPARATED FROM THE VESSEL'S ADULT SIZE LIFE JACKETS. 46 CFR 180.78(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 9 September 2020
Resolution: Proper separation of lifejackets in place.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 September 2020 Resolved
CONNECTIONS MUST BE MADE TO BATTERY TERMINALS WITH PERMANENT TYPE CONNECTORS. SPRING CLIPS OR OTHER TEMPORARY TYPE CLAMPS ARE PROHBITED. VESSEL'S STARBOARD SIDE BATTERY IN THE ENGINE ROOM CONTAINED TEMPORARY CONNECTORS. 46 CFR 183.350(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 9 September 2020
Resolution: Permanent connection put in place.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 September 2020 Resolved
A HATCH COVER MUST BE ATTACHED TO THE HATCH FRAME OR COAMING BY HINGES, CAPTIVE CHAINS, OR OTHER DEVICES OF SUBSTANTIAL STRENGTH TO PREVENT ITS LOSS. VESSEL'S FOREPEAK HATCH COVER WAS MISSING A CAPTIVE CHAIN. 46 CFR 179.360 (b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 1 September 2020
Resolution: Accepted photo showing chain attached to forepeak hatch.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 September 2020 Resolved
VAPOR BARRIERS MUST BE PROVIDED WHERE INSULATION OF ANY TYPE IS USED IN SPACES WHERE FLAMMABLE AND COMBUSTIBLE LIQUIDS OR VAPORS ARE PRESENT, SUCH AS MACHINERY SPACES. TWO PENETRATIONS (STBD/PORT SIDE) OF THE ENGINE ROOM'S BULKHEAD WERE NOT VAPOR-TIGHT. 46 CFR 177.405(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 9 September 2020
Resolution: Engine room bulkheads made vapor tight.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 1 September 2020 Resolved
EXHAUST GAS MUST NOT LEAK FROM PIPING OR ANY CONNECTIONS. THE PIPING MUST BE PROPERLY SUPPORTED BY NON-COMBUSTIBLE HANGERS OR BLOCKS. NOTED TWO LEAKS IN STARBOARD SIDE WET EXHAUST IN ENGINE ROOM PIPING WHILE VESSEL WAS UNDERWAY. 46 CFR 182.430(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 9 September 2020
Resolution: Wet exhaust leaks repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 September 2020 Resolved
A VESSEL MUST CARRY EITHER A FIRST-AID KIT APPROVED UNDER THE APPROVAL SERIES 160.041 OR A KIT WITH EQUIVALENT CONTENTS AND INSTRUCTIONS. A FIRST-AID KIT MSUT BE EASILY VISIBLE AND READILY AVAILABLE TO THE CREW. DISCOVERED THE VESSEL'S FIRST AID CONTENTS WERE EXPIRED. VESSEL'S CREW SWITCHED OUT FIRST-AID KIT WITH A FIRST-AID KIT WITH VALID/UP TO DATE CONTENTS. 46 CFR 160.041
Action required: 10 - Deficiency Rectified
Due 1 September 2020
Resolved 1 September 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 September 2020 Resolved
EMPLOYERS MUST MAINTAIN RECORDS OF CHEMICAL TESTS AS PROVIDED IN 49 CFR 40.333. MULTIPLE RECORDS FOR DRUG AND ALCOHOL PROGRM WERE NOT AVAILABLE FOR INSPECTION. 46 CFR 16.260
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 9 September 2020
Resolution: Owner provided records for DAPI program.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 10 July 2019 Resolved
Complete an inspection for COI, including details of repair to the superstructure of the vessel. Vessel's cabin was crushed while it was being transported as barge deck cargo during an allision between the barge and a freight ship.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2019
Resolved 1 September 2020
Resolution: Repairs to cabin completed and verified during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2019 Resolved
A vessel to which this subchapter applies (46CFR 176.100) may not be operated without having on board a valid US Coast Guard Certificate of Inspection. Complete a satisfactory inspection for COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2019
Resolved 11 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 4 October 2018 Resolved
MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 April 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2018 Resolved
Due to reported grounding on 7/16/18 vessel is required to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. 46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2018
Resolved 31 July 2018
Resolution: Sea trial completed. See documents for photos and documentation of repairs.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 May 2018 Resolved
REPAIR DSC FUNCTION OF VHF RADIO. VESSEL NOT TO OPERATE OUTSIDE INLAND WATERS.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 26 June 2018
Resolution: FCC issued new safety radio certificate following inspection.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 2 May 2018 Resolved
MASTER'S LICENSE LIMITED TO INLAND WATERS. VESSEL NOT TO OPERATE OUTSIDE INLAND WATERS WITHOUT PROPERLY LICENSED MASTER.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 2 May 2018
Resolution: Operator notified of requirement.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
HATCH COVER CAPTIVE CHAIN FAILED. VESSEL NOT TO OPERATE OUTSIDE INLAND WATERS.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Chain replaced.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
RUDDER PACKING GLAND BOLTS TOO SHORT AND NOT ENGAGING LOCK NUTS.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Longer bolts installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2018 Resolved
GENERATOR BATTERY TERMINALS CORRODED AND BOX OPEN.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Terminals cleaned, cover re-installed.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
HOLE FOUND IN LAZ FORWARD BULKHEAD TO ENGINE ROOM. TEMP REPAIR AUTHORIZED UNTIL NEXT DRYDOCK. VESSEL NOT REQUIRED TO HAVE SUBDIVISION BEYOND A COLLISION BULKHEAD.
Action required: 705 - Other - as specified
Resolved 31 July 2018
Resolution: Insert installed. See photos in documents.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
CRACKS FOUND IN PORT AND STARBOARD QUARTER WELDS.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Gouged and re-welded.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
CRACK FOUND IN LAZ PORT SIDE OVERHEAD WELD TO DECK.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Gouged and re-welded.
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
CRACK FOUND IN FOREPEAK PORT SIDE WELD.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Gouged and re-welded.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2018 Resolved
OPEN-ENDED WIRING FOUND IN CONSOLE.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Open ended wire removed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 May 2018 Resolved
ADD LOWER CHAIN RAIL COURSE ACROSS AFT HAND RAILS.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Lower chain rail added.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 2 May 2018 Resolved
EPLACE WASTED THIMBLE IN ANCHOR LINE EYE.
Action required: 705 - Other - as specified
Due 2 June 2018
Resolved 9 May 2018
Resolution: Thimble replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 November 2017 Resolved
Vessel must undergo an annual inspection prior to operation. Vessel is no-sailed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 December 2017
Resolution: Completed annual exam.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 January 2017 Resolved
Vessel dry dock expired 31 Dec 2016. Make vessel ready for dry dock exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2017
Resolved 10 January 2017
Resolution: Vessel pulled out of the water for dry dock.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 September 2015 Resolved
Remove from vessel 1 Adult and 2 Child Lifejackets that are no longer usable.
Condition: Improper/Lack of Maintenance
Due 4 September 2015
Resolved 4 September 2015
Resolution: Vessel was equipped with more than than enough lifejackets, so the bad ones were removed with no additional required.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 August 2015 Resolved
Provide new fire extinguisher mount for deck extingusher
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2015
Resolved 10 September 2015
Resolution: Installed new bracket for fire extinguisher.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 August 2014 Resolved
Replace grabline on 01 life ring buoy IAW 46 CFR 180.70(c)(6)
Due 19 August 2014
Resolved 6 August 2014
Resolution: Grablines were replaced.
Navigation › Piloting/Steering › Marine Charts
Issued 5 August 2014 Resolved
Provide up to date nautical charts and publications. IAW 46CFR184.420.
Due 19 August 2014
Resolved 6 August 2014
Resolution: New charts recieved.
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 13 July 2011 Resolved
07 lifejackets did not pass inspection and were destroyed on site.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 August 2011
Resolved 13 July 2011
Resolution: New jackets were purchased that day.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 July 2011 Resolved
A hydraulic hose was resting on top of the battery box and melted trough the top. place hose in a bracket off of the box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 10 August 2011
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 16 March 2010 Resolved
Prove proper operation of the port main diesel engine prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2010
Resolved 19 March 2010
Engineering › Fuel Oil Service System › Valve, Control
Issued 28 November 2008 Resolved
Prove proper operation of F/O shut off valve remote actuator.
Due 4 December 2008
Resolved 1 December 2008
Resolution: Corrected
Engineering › Fuel Oil Service System › Ventilation
Issued 28 November 2008 Resolved
Provide 30x30 mesh screens on F/O vent.
Due 5 December 2008
Resolved 1 December 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Manifold
Issued 28 November 2008 Resolved
Prove proper operation of bilge manifold valves.
Due 5 December 2008
Resolved 1 December 2008
Resolution: Corrected.
Stability › Weathertight Integrity › General
Issued 28 November 2008 Resolved
Provide new seal for main cabin door.
Due 5 December 2008
Resolved 1 December 2008
Resolution: Corrected.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 November 2008 Resolved
Provide new seal for lazarette hatch.
Due 5 December 2008
Resolved 1 December 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 November 2008 Resolved
Lable all power pannel breakers.
Due 5 December 2008
Resolved 1 December 2008
Resolution: Corrected
Fire Fighting › Fire Main › Pressure
Issued 12 July 2007 Resolved
Repair fire fighting system to the satisfaction of the attending marine inspector
Action required: 705 - Other - as specified
Due 26 July 2007
Resolved 26 July 2007
Resolution: Vessel representative performed proper operation of fire fighting system.
Engineering › Fuel Oil Service System › Piping
Issued 24 July 2006 Resolved
Repair/Replace fuel supply piping to normal operating standards;absent of leaks prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2006
Resolution: Replaced fuel supply piping. No longer leaking.
Engineering › Bilge Water Management System › Pump
Issued 24 July 2006 Resolved
Provide/prove proper operation of bilge pump in the engine room which also serves as the fire pump IAW 182.510.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2006
Resolution: Repaired bilge/fire pump.
Communications › Radio Communications › EPIRB
Issued 26 May 2005 Resolved
Renew vessel EPIRB registration IAW 46CFR 180.64. Vessel is restricted to not more than 3 miles from land.
Due 26 July 2005
Resolved 28 June 2005
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 May 2005 Resolved
Provide 3 type one child size PFD's, label and Stow them IAW 46CFR 180.71.
Action required: 705 - Other - as specified
Resolved 26 May 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 May 2005 Resolved
Replace chain keeper to port side rail.
Action required: 705 - Other - as specified
Resolved 26 May 2005
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2005 Resolved
Clad weld 08 deep isolated pits on stbd side aft to mid way circled in yellow caulk.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 25 April 2005 Resolved
Properly support electrical cables in way of passengers compartment void.
Due 25 May 2005
Resolved 11 May 2005
Engineering › Bilge Water Management System › Not Operational
Issued 25 April 2005 Resolved
Prove proper operation of all bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 April 2005 Resolved
Repair cracked weld in way of lazarrate, stbd exhaust inboard, by ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 25 April 2005 Resolved
Repair both port and stbd exhaust leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2005 Resolved
Repair port side plate and inform marine inspector prior to fit up, back gouge, and air lance test for final inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 July 2004 Resolved
Post all pages of COI and Stability Letter.
Due 21 August 2004
Resolved 22 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 July 2004 Resolved
Renew expired burn spray in first aid kit.
Due 21 August 2004
Resolved 22 July 2004
Communications › Radio Communications › EPIRB
Issued 21 July 2004 Resolved
Renew expired hydrostatic release and battery for EPIRB, provide proof of current registration.
Due 21 August 2004
Resolved 22 July 2004
Lifesaving › Lifefloat › Float-free Link
Issued 21 July 2004 Resolved
Provide weaklinks of proper rating for both lifefloats.
Due 21 August 2004
Resolved 22 July 2004
Lifesaving › Lifefloat › Paddle
Issued 21 July 2004 Resolved
Properly attach paddles to bottom lifefloat.
Due 21 August 2004
Resolved 22 July 2004
Documentation › Logs/Records › Logbook (official)
Issued 21 July 2004 Resolved
Create drill/training log to properly document drills & training conducted.
Due 21 August 2004
Resolved 19 August 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 July 2004 Resolved
Provide plans to repair 1 inch hole in engine room/lazarette blkhd below fuel tank.
Due 21 August 2004
Resolved 22 July 2004
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 July 2004 Resolved
Eliminate leak on fuel oil return line fitting on fuel tank in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 July 2004 Resolved
Eliminate chaffing of hydraulic steering hoses in way of rudder tie rod.
Due 21 August 2004
Resolved 22 July 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 July 2004 Resolved
Provide proof of current servicing for engine room CO2 extingusher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Electrical › Electric Supply System (service)
Issued 2 July 2003 Resolved
Provide plans to replace starting battery cables with marine type. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 27 August 2003
Resolution: Plans approved and witnessed installation of new cables.
Construction/Loadline › Penetrations
Issued 18 June 2003 Resolved
Make forward and aft engine room bulkheads vaportight.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 3 July 2003
Engineering › Bilge Water Management System
Issued 18 June 2003 Resolved
Install check valves in all bilge suction lines. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 3 July 2003
Engineering › Bilge Water Management System
Issued 18 June 2003 Resolved
Remove mercury bilge switch and replace with correct type.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 3 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 June 2003 Resolved
Provide plans to install exhaust cooling flow alarms in both MDE exhaust systems. LEGACY COMPONENT DESC: Silencer (exhaust)
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 3 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 June 2003 Resolved
Remove Belzona and make permanent repairs to port side exhaust sysytem. LEGACY COMPONENT DESC: Silencer (exhaust)
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 3 July 2003
Electrical › Lighting (service)
Issued 18 June 2003 Resolved
Replace cage on light globe in engine room.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 3 July 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 May 2002 Resolved
Renew wire and lug on shutdown solenoid of starboard main diesel engine. LEGACY COMPONENT DESC: Governor
Due 28 June 2002
Resolved 31 May 2002
Resolution: Wire to solenoid has been renewed.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 26 May 2002 Resolved
Install proper fitting to engine room for external CO2 fire extinguishing system connection to engine room. LEGACY COMPONENT DESC: Location
Due 28 June 2002
Resolved 31 May 2002
Resolution: Fitting installed with fire extinguisher nozzle properly installed.
Documentation › Certificates/Documents
Issued 26 May 2002 Resolved
Provide copy of Stability letter to MSO San Francisco and post original in pilot house in conspicious view of the operating station. LEGACY COMPONENT DESC: Stability Letter
Due 28 June 2002
Resolved 31 May 2002
Resolution: Stability letter posted properly and copy provided to MSO San Francisco inspections department.
Accommodation/Occupational Safety › Medical/First Aid
Issued 26 May 2002 Resolved
Renew aspirin in first aid kit that is expired. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 31 May 2002
Resolved 31 May 2002
Resolution: Aspirin in first aid kit renewed.
Construction/Loadline
Issued 27 April 2001 Resolved
CLEARLY MARK THE NAME OF THE VESSEL ON THE PORT AND STARBOARD BOW, AS WELL AS, THE STERN. ALSO, MARK THE HAILING PORT ON THE STERN. (46 CFR 67.123)
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Documentation
Issued 27 April 2001 Resolved
CONTACT NATIONAL VESSEL DOCUMENTATION CENTER (NVDOC, [phone withheld]) AND CORRECT NAME OF VESSEL. FAX DOCUMENTATION OF NAME CHANGE TO THIS OFFICE, [phone withheld], ATTENTION OF [name withheld] PRIOR TO 27MAY01.
Condition: Unknown
Due 27 May 2001
Resolved 10 May 2001
Lifesaving
Issued 27 April 2001 Resolved
MARK OR PAINT IN CLEARLY LEGIBLE LETTERS AND NUMBERS THE VESSEL'S NAME ON THE FOLLOWING: LIFEFLOATS, LIFEJACKETS, LIFE FLOAT PADDLES, EPIRB. (46 CFR 185.604)
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Construction/Loadline
Issued 19 May 2000 Resolved
REPLACE INOPERATIVE LAZERETTE BILGE SUCTION VALVE.
Condition: Unknown
Due 19 May 2000
Resolved 10 July 2000
Navigation
Issued 19 May 2000 Resolved
PROVIDE ON BOARD A CURRENTLY CORRECTED COPY OF THE REQUIRED LIGHTLIST, COAST PILOT AND NAV CHARTS.
Condition: Unknown
Due 19 May 2000
Resolved 10 July 2000
Unknown
Issued 19 May 2000 Resolved
COMMENCE THE LOGGING OF ALL REQUIRED DRILLS AND "EPIRB" TESTING.
Condition: Unknown
Due 19 May 2000
Resolved 10 July 2000
Construction/Loadline
Issued 25 May 1999 Resolved
Install bilge high level alarm for lazarette.
Condition: Unknown
Due 21 July 1999
Resolved 21 July 1999
Documentation
Issued 25 May 1999 Resolved
Provide valid FCC Radio Safety Certificate.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Documentation
Issued 24 November 1995 Resolved
PROVIDE CURRENT FCC SAFETY RADIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 24 November 1995
Resolved 24 November 1995
Documentation
Issued 24 November 1995 Resolved
PROVIDE PROOF VESSEL MAINTAINS CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 24 December 1995
Resolved 1 March 1996
Engineering
Issued 24 November 1995 Resolved
PROVIDE PROTECTIVE GUARDS FOR BELTS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 24 December 1995
Resolved 1 March 1996
Documentation
Issued 24 November 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 December 1995
Resolved 1 March 1996
Navigation
Issued 17 November 1992 Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD RUNNING LIGHTS.
Condition: Unknown
Due 17 November 1992
Resolved 17 November 1992
Construction/Loadline
Issued 17 November 1992 Resolved
MAKE PERMANENT REPAIRS TO CRACKED WELDS AND FRACTURE IN WAY OF CORNER WRAPPER AT STARBOARD SIDE OF TRANSOM.
Condition: Unknown
Due 17 November 1992
Resolved 17 November 1992
Documentation
Issued 16 July 1992 Resolved
PROVIDE STABILITY LETTER OR CONDUCT A SIMPLIFIED STABILITY TEST IN PRSENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 July 1992
Resolved 16 July 1992
Documentation
Issued 11 February 1992 Resolved
PROVIDE PROOF OF STABILITY, DOCUMENTED EVIDENCE FOR TOTAL NUMBER OF PEOPLE CARRIED FOR DETERMINING SATISFACTORY STABILITY IN SERVICE, OR MAKE VESSEL AVAILABLE FOR A SIMPLIFIED STABILITY TEST IAW 46CRF170.120(B) AND 46CFR170.160(B).
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Documentation
Issued 4 February 1992 Resolved
PULL VESSEL OUT OF WATER AND MAKE AVAILABLE FOR DRYDOCK INSPECTION BY ATTENDING USCG INSPECTOR -46 CFR 176.15
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992
Engineering
Issued 21 March 1991 Resolved
INSTALL OVERSPEED DEVICES ON BOTH PROPULSION DIESEL ENGINES ONBOARD.
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Electrical
Issued 27 September 1988 Resolved
REINSTALL STBD CONSTAVOLT BATTERY CHARGER OR REMOVE WIRING WHERE CHARGER WAS.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Navigation
Issued 27 September 1988 Resolved
PROVE PROPER OPERATION OF PILOT HOUSE HORN
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Construction/Loadline
Issued 27 September 1988 Resolved
RENEW CENTER WINDSHIELD GLASS DUE TO CRACKS
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Engineering
Issued 27 September 1988 Resolved
CONDUCT OPERATIONAL TEST OF MAIN DIESEL ENGINES, CONTROLS, AND STEERING GEAR IN THE PRESENCE OF COGNIZANT MARINE INSPECTOR.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988 Resolved
MAKE REPAIRS TO STBD BATTERY BOX IN MACHINERY SPACE
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Documentation
Issued 28 January 1988 Resolved
PROVIDE PROOF OF VALID VESSEL DOCUMENTATION TO MSO MORGAN CITY.
Condition: Unknown
Due 28 January 1988
Resolved 28 January 1988
Navigation
Issued 28 January 1988 Resolved
UPDATE REQUIRED PUBLICATIONS AS PER 46 CFR 185.20-35.
Condition: Unknown
Due 28 January 1988
Resolved 28 January 1988
Unknown
Issued 23 October 1985 Resolved
PROVIDE SUITABLE EXHAUST LAGGING BETWEEN THE ENGINE AND THE POINT OF COOL- ING WATER ENTRY TO THE SYSTEM FOR BOTH MAIN DIESEL ENGINES AND SHIPS SER- VICE GENERATOR. 46 CFR 182.15-15 (B)(3) SEE 46 CFR 182.20-20 FOR REFERAL TO THE ABOVE REFERANCE. GENERATOR PIPING MUST BE COMPLETE LENGTH (DRYPIPE)
Condition: Unknown
Due 23 October 1985
Resolved 23 October 1985
Engineering
Issued 27 September 1985 Resolved
PROVIDE SUITABLE EXHAUST LAGGING BETWEEN THE ENGINE AND THE POINT OF COOL- ING WATER ENTRY TO THE SYSTEM FOR BOTH MAIN DIESEL ENGINES AND SHIP'S SER- VICE GENERATOR. 46 CFR 182.15-15(B)(3). GENERATOR PIPING MUST BE COMPLETELONGTH(DRY PIPE) NO MATERIAL CONTAINING ASBESTOS MUST BE USED
Condition: Unknown
Due 27 September 1985
Resolved 27 September 1985

Casualty record · 3

6 August 2010Routine · role: Involved in a Marine Casualty · activity 3833711
16 July 2018Routine · role: Involved in a Marine Casualty · activity 6496665
12 July 2019Routine · role: Involved in a Marine Casualty · activity 6792662
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.