SEA STRIKE

SEA STRIKE is a 1982 oil recovery. The Coast Guard has recorded 97 inspections since 1982, most recently in June 2026, along with 113 deficiencies and 1 casualty investigation in 2017.

Records from 1982 to 2026. Most recent: inspection, 4 June 2026.

Built
1982
Last inspected
4 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDR2319
Flag
UNITED STATES
338148000
Maury page id
psix-54377

Inspections, by type

…with no type recorded15
Years with a record 40 calendar years (1982–2026)
The 97 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)122.1 ft × 34.1 ft × 11.5 ft
Registered tonnagegross 82 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCULLY BROS BOAT BUILDERS · STEPHENSVILLE LA · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKODIAK, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 July 2026 · expires 31 August 2027
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Net Ton
82 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR2319MMSI 338148000 · active · compulsorily equipped · granted 6 June 2026, expires 6 June 2036
WDH9723MMSI 338148000 · expired · compulsorily equipped · granted 7 May 2015, cancelled 14 June 2025
WDE2078MMSI 367320140 · cancelled · compulsorily equipped · granted 27 October 2007, cancelled 1 October 2014
WUR9525MMSI 366943930 · expired · voluntarily equipped · granted 29 April 2004, cancelled 19 July 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

180-2 Freight Barge · MISLE 49688 · 29 June 2017 · activity 6198783MISS DESTINEE Commercial Fishing Vessel · MISLE 130297 · 29 June 2017 · activity 6198783EL CAPORAL Commercial Fishing Vessel · MISLE 181596 · 29 June 2017 · activity 6198783

Inspection history · 97

4 June 2026 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8390969
2 October 2025 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8245720
3 April 2025 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8097725
30 January 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8072018
16 November 2023 Administrative Inspection · Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7826074
2 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7802268
19 July 2023 In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7747679
20 October 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7579078
23 November 2021 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7356570
30 November 2020 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7105988
21 September 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7073597
12 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6926363
13 February 2019 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6625491
8 September 2018 Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6539229
28 February 2018 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6412211
10 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6335888
29 June 2017 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6198783
16 November 2016 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6043236
10 September 2015 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5718206
7 May 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4280552
13 February 2012 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4243754
21 December 2011 Examination of Repairs · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4211139
27 April 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3469091
29 September 2008 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3335092
14 May 2008 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3175652
19 July 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2998164
3 October 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2792935
23 August 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2757614
2 August 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2726940
3 February 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2579043
8 August 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2415324
10 June 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2386001
1 February 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2338825
1 October 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2206762
12 August 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2163191
28 July 2003 Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1846869
16 September 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1675304
4 September 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1670719
4 September 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1677527
23 August 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1665486
9 August 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1654399
28 May 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1621753
8 August 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1389463
10 August 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1386863
20 September 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1194259
16 August 1999 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 777906
12 August 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1112087
12 August 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1388594
14 July 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 212394
18 September 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 774894
4 September 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1386091
14 August 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1119699
21 November 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 760244
20 November 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 191691
16 August 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1380617
11 December 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 878094
18 August 1995 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1189034
4 August 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 879190
6 December 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 647840
16 September 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 174997
25 August 1994 Deficiency Check · Excursion Permit
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 865061
15 August 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1177846
1 March 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166707
4 February 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 852187
19 January 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870049
30 August 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 854122
23 August 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 847193
20 August 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 845254
5 August 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844315
15 December 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 829891
5 November 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1257555
15 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1268179
9 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 954350
17 September 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 959266
25 August 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 956622
7 August 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263204
7 October 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 941758
16 September 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1249764
25 September 1990 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1216976
29 August 1990 Drydock Extension · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 919799
28 December 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921213
25 October 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1208918
20 September 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900558
13 January 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1197477
5 January 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1043158
28 November 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1206282
12 October 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 886710
3 September 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312926
24 August 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312925
4 March 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312495
10 September 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1321097
15 January 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 991554
18 December 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1303952
18 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285571
21 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 976622
6 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1283960
21 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967813

Deficiency record · 113

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 June 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 June 2026
Resolution: Received new FCC station license and ship's radio equipment updated with correct information.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2025 Resolved
All firehose must be subjected to a test pressure equivalent to the maximum pressure to which they may be subjected in service, but not less than 100 p.s.i. Marine inspector observed fire hose leaking when tested. Replace existing hose with a new hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2025
Resolution: Verified Satisfactory Test of New Hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 April 2025 Resolved
Shutoff valves shall be installed in the fuel supply lines and installed to prevent leakage. The port fuel supply line shutoff valve leaked when tested. Repair valve and prepare for testing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2025
Resolution: Verified functionality of Remote Valve. No Leaks.
09 - Working and Living Conditions › 091 - Living Conditions › Minimum age
Issued 3 April 2025 Resolved
Each first-aid kit must meet the requirements in ISO 18813:2006(E) paragraph 4.12 (incorporated by reference, see § 199.05). First Aid Kit items were expired when examined. Replace expired items.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 April 2025
Resolution: Verified presence of Replaced items. All within expiration dates.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025 Resolved
Electric equipment must be arranged, as far as practicable, to prevent mechanical damage to the equipment. Marine Inspector observed UPS box secured with a bungy cord. Properly secure UPS box to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 April 2025
Resolution: Verified proper securing with velcro strap and bracketing.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Loose wires observed in the control station. Remove open ended wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 April 2025
Resolution: All wires were removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2025 Resolved
This subchapter provides the specifications, standards and requirements for strength and adequacy of design, construction, installation, inspection, and choice of materials for machinery, boilers, pressure vessels, safety valves, and piping systems upon which safety of life is dependent. Steering gear hoses in the steering compartment were found inadequately supported by wire conduits. Install proper bracket supports comparable to original construction.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025 Resolved
No flexible cord may be used except:(1) As allowed under Sections 400.10 and 400.12 of NFPA 70; and(2) In accordance with Table 400.4 in NFPA 70. ECO dam sub pumps were connected utilizing flexible cords. Remove flexible cords and connect pumps directly to outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 April 2025
Resolution: Sump pumps were hire-wired in with appropriate wire of size.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 April 2025 Resolved
Vessels required to meet applicable stability standards with Sub-chapter S (old), must have an indicator light for watertight doors in watertight bulkheads below the main deck. There was no indicator light installed on the engine room WTBs.
Action required: 705 - Other - as specified
Resolved 12 June 2026
Resolution: Vessel was built and certificated prior to regulation coming into affect.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 October 2022 Resolved
Each vessel must carry not less than 12 rocket parachute flares approved under approval series 160.136. Vessel has mixture of 6 hand flares, 3 rocket parachute flares, and 3 smoke flares. 46 CFR 199.60(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 15 November 2022
Resolution: Vessel obtained 12 rocket parachute flares.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 October 2022 Resolved
Approved fire extinguishing systems are required on all self propelled vessels. Vessel's fire extinguishing system did not shut down vessel's engines as per the design approval. 46 CFR 95.05-10(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2022
Resolution: Vessel demonstrated satisfactory engine shut downs.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 20 October 2022 Resolved
Tests and inspections to evaluate the operation and reliability of controls, alarms, and safety features for monitored machinery systems must be verified periodically. The E/R Main Machinery Alarm Panel power failure test did not function as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 15 November 2022
Resolution: Vessel replaced batteries in engine room main machinery alarm panel and it functioned as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2022 Resolved
Fuel strainer outlets shall have no openings or peacocks. Both main engines have dual Racor fuel filters with peacock valves installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 15 November 2022
Resolution: Vessel replaced petcock valves on Racor filters
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 November 2021 Resolved
Vessel is required to have Notice to Mariners, Light List, Coast Pilot, Current and Tide Tables on board and up to date; must provide all applicable nautical publications as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 1 December 2021
Resolution: MSD Kodiak witnessed the correction of the deficiency.
Construction/Loadline › Penetrations › Gasket
Issued 7 May 2012 Resolved
REPLACE GASKET ON WATERTIGHT DOOR TO LOWER HOUSE ENTRANCE.
Action required: 705 - Other - as specified
Due 14 May 2012
Resolved 15 May 2012
Resolution: Gasket was replaced.
Construction/Loadline › Penetrations › Gasket
Issued 7 May 2012 Resolved
CLEAN ALL GASKETS AND KNIFE EDGES ON HATCHES THROUGHOUT VESSEL.
Action required: 705 - Other - as specified
Due 14 May 2012
Resolved 15 May 2012
Resolution: Gaskets and knife edges were cleaned.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 7 May 2012 Resolved
REMOVE WATER FROM # 1 STARBOARD VOID AND MAKE AVAILABLE FOR INSPECTION.
Action required: 705 - Other - as specified
Due 14 May 2012
Resolved 15 May 2012
Resolution: Water was removed and the void was made ready for inspection.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 7 May 2012 Resolved
REPAIR OR REPLACE VENTILATION FAN TO POWER GRILL / RANGE IN GALLEY.
Action required: 705 - Other - as specified
Due 14 May 2012
Resolved 15 May 2012
Resolution: ventalation fan was replaced.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 14 May 2008 Resolved
Provide cargo transfer operations IAW 33CFR 155.720 meeting the requirements of 33CFR 155.750.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2008
Resolved 22 May 2008
Resolution: Transfer procedures provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 August 2006 Resolved
Provide 13 serviceable Type I lifejackets.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2006
Resolved 2 August 2006
Resolution: Corrected on the spot.
Lifesaving › Immersion Suits › Marking
Issued 2 August 2006 Resolved
Stencil 01 immersion suit with vessel name.
Due 2 September 2006
Resolved 2 August 2006
Resolution: Corrected on the spot.
Engineering › Fuel Oil Service System › Valve, Control
Issued 2 August 2006 Resolved
Make permanent repairs to the Port F/O storage tank emergency F/O shut-off valve reach rod.
Condition: Improper/Lack of Maintenance
Due 2 September 2006
Resolved 22 August 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 August 2006 Resolved
Label lifejacket stowage areas with type and amount of jackets stored.
Due 2 September 2006
Resolved 22 August 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 August 2006 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Due 2 September 2006
Resolved 22 August 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 August 2004 Resolved
Certificate of Documentation was expired.
Due 12 September 2004
Resolved 18 August 2004
Resolution: COD RENEWED.
Stability › Weathertight Integrity › General
Issued 12 August 2004 Resolved
Port and starboard chain locker hatch requires securing chain.
Due 12 September 2004
Resolved 18 August 2004
Resolution: Securing chain installed
Electrical
Issued 28 July 2003 Resolved
Install die-electric matting in front of switchboard.
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 12 August 2003
Resolution: Received fax from operator with receipt for die-electric matting.
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 July 2003 Resolved
Update first aid kit and remove outdated medications.
Action required: 705 - Other - as specified
Due 28 August 2003
Resolved 12 August 2003
Resolution: Received fax from owner with receipt of new first aid kit.
Electrical › Lighting (emergency)
Issued 9 August 2002 Resolved
Add additional "E" Lighting to both port and starboard machinery space egress. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: Two additional "Battle lantern" style "E" lights were installed, one port, one stbd.
Electrical › Electric Supply System (service)
Issued 9 August 2002 Resolved
Submit plans for new bilge alarms installation in lazarette.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 23 August 2002
Resolution: Received and approved plans Aug 22, 2002
Engineering
Issued 9 August 2002 Resolved
Renew hot water heater pressure temperature relief valve with a valve that does not exceed 100 psig.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: New relief valve installed 75-100 psi.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 August 2002 Resolved
Repair as new main engine alarm panel.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: Repairs completed, tested sat.
Construction/Loadline › Structures
Issued 9 August 2002 Resolved
Make lazarette and fwd engine room bulkheads watertight in way of electrical penetrations. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: Electrical penetrations properly secured in stuffing tubes.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 9 August 2002 Resolved
Repair as new port main engine overspeed device.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: Port Main Engine ovrspd device tested sat.
Construction/Loadline › Structures
Issued 9 August 2002 Resolved
Remove PVC piping in way of fwd engine room bulkhead. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: PVC piping removed and hole capped off properly.
Electrical › Electrical Distribution System (service)
Issued 9 August 2002 Resolved
Relocate 110VAC wire running into switchboard in way of aft switchboard enclosure. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: Wire rerouted and properly secured to pannel.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 9 August 2002 Resolved
Show proper operation of low fuel oil pressure switches on both ships service generators.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: Tested sat.
Lifesaving
Issued 9 August 2002 Resolved
Mark immersion and PFD stowage IAW 46 CFR 199.70.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: All PFD and immersion suit stowage locations properly marked.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 August 2002 Resolved
Replace retro on PFD.
Due 9 August 2002
Resolved 9 August 2002
Lifesaving › Rescue Boat
Issued 9 August 2002 Resolved
Make equipment IAW 46 CFR 199.175 available for rescue boat.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: Rescinded. Vessel is exempt from meeting these requirements.
Lifesaving › Line-Throwing Appliances
Issued 9 August 2002 Resolved
Make line throwing appliance available and readily accessible for use.
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 8 August 2003
Resolution: Deleted this requirement as it does not apply to this vessel.
Deck/Cargo
Issued 9 August 2002 Resolved
Proof load test crane and post safe working load.
Action required: 705 - Other - as specified
Due 9 September 2002
Resolved 4 September 2002
Resolution: O/O provided certificate of proof test conducted on crane. Crane properly labled and certificate retained on board vessel.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 9 August 2002 Resolved
Repair as new "E" lighting in starboard machinery egress.
Due 9 August 2002
Resolved 9 August 2002
Construction/Loadline
Issued 8 August 2001 Resolved
PROVIDE A BILGE HIGH LEVEL ALARM FOR THE LAZARETTE IAW 46 CFR 182.530.
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Lifesaving
Issued 12 August 1999 Resolved
Demonstrate low lube oil and overspeed trips for #1 generator.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Engineering
Issued 12 August 1999 Resolved
Replace plastic guage glass & guards for starboard lube oil tank with glass.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Navigation
Issued 14 August 1997 Resolved
PROVE PROPER OPERATION OF FATHOMETER (1 OF 2 ONBOARD).
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Deck/Cargo
Issued 14 August 1997 Resolved
HYDRO-TEST AND STAMP CARGO HOSES.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Engineering
Issued 14 August 1997 Resolved
PROVE PROPER OPERATION OF LOW L/O SHUT-DOWN ON STBD GENERATOR.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Engineering
Issued 16 August 1996 Resolved
PROVE PROPER OPERATION OF OVERSPEED PROTECTION ON BOTH MAIN DIESELS.
Condition: Unknown
Due 16 September 1996
Resolved 2 October 1996
Documentation
Issued 11 December 1995 Resolved
HAVE ABS CONDUCT ADMEASUREMENT SURVEY AND ISSUE NEW CERTIFICATE. THIS IS DUE TO DECK DECANTING TANK NOT FIGURED IN VESSEL GROSS TONNAGE WHEN VESSEL WAS CONVERTED FROM OSV TO OSRV.
Condition: Unknown
Due 11 February 1996
Resolved 11 December 1995
Construction/Loadline
Issued 18 August 1995 Resolved
REPAIR AS ORIGINAL 4TH BAFFLE BETWEEN OVERHEAD AND DECK IN STBD AFT BALLASTTANK.
Condition: Unknown
Due 18 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 18 August 1995 Resolved
MAKE PERMANENT REPAIRS IN LIEU OF SOFT PATCH ON BALLAST DISCHARGE PIPE.
Condition: Unknown
Due 18 August 1995
Resolved 13 September 1995
Construction/Loadline
Issued 18 August 1995 Resolved
INSTALL BUG SCREEN ON POTABLE WATER TANK VENTS.
Condition: Unknown
Due 18 September 1995
Resolved 13 September 1995
Accommodation/Occupational Safety
Issued 18 August 1995 Resolved
INSTALL BOLTS IN POTABLE WATER PIPING FLANGE IN ENGINEROOM PORT SIDE AFT.
Condition: Unknown
Due 18 September 1995
Resolved 13 September 1995
Engineering
Issued 18 August 1995 Resolved
PROVE PROPER OPERATION OF HIGH JACKET WATER TRIP ON #1 AND #2 GENERATORS.
Condition: Unknown
Due 18 September 1995
Resolved 13 September 1995
Engineering
Issued 18 August 1995 Resolved
REPAIR/REPLACE AUDIBLE ALARM FOR ENGINE LOW LUBE OIL PRESSURE ON BRIDGE.
Condition: Unknown
Due 18 September 1995
Resolved 14 September 1995
Construction/Loadline
Issued 4 August 1995 Resolved
CUT-OUT AND PLACE INSERTS IN CRACKS IN BAFFLE PLATES 3 & 4 IN NO. 2 BALLASTTANK STBD IN WAY OF OUTBOARD NEXT TO SIDE SHELL. MAKE INSERTS 18"X18", RADIUS CORNERS INBOARD, EXTEND WELDS NEXT TO SIDE SHELL AT LEAST 6-12".
Condition: Unknown
Due 18 August 1995
Resolved 28 August 1995
Electrical
Issued 4 August 1995 Resolved
REWIRE HYDRAULIC CRANES PORT & STBD EMERGENCY ELECTRICAL SHUTDOWNS WITH ARMORED OR [name withheld].
Condition: Unknown
Due 18 August 1995
Resolved 13 September 1995
Engineering
Issued 15 August 1994 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM (AUDIBLE) ON BRIDGE.
Condition: Unknown
Due 15 September 1994
Resolved 25 August 1994
Navigation
Issued 15 August 1994 Resolved
RENEW FADED COMPASS DEVIATION CARD.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Documentation
Issued 23 August 1993 Resolved
PROVIDE MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 26 November 1993
Resolved 26 November 1993
Lifesaving
Issued 23 August 1993 Resolved
PROVIDE 6 ORANGE FLARES BY 1/94
Condition: Unknown
Due 26 November 1993
Resolved 26 November 1993
Lifesaving
Issued 23 August 1993 Resolved
PROVIDE 6 RED FLARES BY 4/94.
Condition: Unknown
Due 26 November 1993
Resolved 26 November 1993
Electrical
Issued 23 August 1993 Resolved
PROVE OPERATION OF LOW LUBE OIL TRIP.
Condition: Unknown
Due 26 November 1993
Resolved 26 November 1993
Fire Fighting
Issued 23 August 1993 Resolved
STOW FIRE AXE IN CLOSER PROXIMITY TO BRIDGE.
Condition: Unknown
Due 26 November 1993
Resolved 26 November 1993
Construction/Loadline
Issued 17 September 1992 Resolved
PLACE CORRECT HOME/HAILING PORT ON VESSEL'S STERN.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Electrical
Issued 17 September 1992 Resolved
REPAIR EMERGENCY LIGHT OVER ELECTRIC PANEL ENGINE ROOM.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Lifesaving
Issued 17 September 1992 Resolved
REPLACE OUTDATED LIGHTS ON 3 EXPOSURE SUITS PRIOR TO CONDUCTING UNDERWAY OPERATIONS.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Electrical
Issued 17 September 1992 Resolved
PROPERLY SECURE LOOSE WIRE ENDS IN FITTING ABOVE ENGINE ROOM DOOR. ENSURE DISCONNECTS AT PANEL.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Documentation
Issued 17 September 1992 Resolved
ENSURE NEW DOCUMENT STICKER ON DOCUMENT.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Engineering
Issued 17 September 1992 Resolved
TIGHTEN PACKING ON EMERGENCY FUEL SHUT-OFF REACH RODS.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Accommodation/Occupational Safety
Issued 17 September 1992 Resolved
SECURE MICROWAVE OVEN._x001C_
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Engineering
Issued 17 September 1992 Resolved
REPLACE SAFETY RELIEF ON AIR RECEIVER, POP SAFETY.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Construction/Loadline
Issued 7 August 1992 Resolved
REPAIR BROKEN TACK WELDS ON BAFFLES INWAY OF VSL SIDE SHELL IN #2 BALLAST TANKS P & S SIDES. PROVIDE SKETCH OF REPAIRS TO USCG.
Condition: Unknown
Due 12 August 1992
Resolved 27 August 1992
Documentation
Issued 7 August 1992 Resolved
PROVIDE CURRENT GAUGING REPORT OF VESSEL TO THE USCG.
Condition: Unknown
Due 7 August 1992
Resolved 7 August 1992
Deck/Cargo
Issued 7 August 1992 Resolved
REPAIR CRACKS IN #2 PRODUCT TANKS PORT & STBD SIDE ON BAFFLES #2 & 3. PROVIDE SKETCH OF REPAIRS TO USCG INSPECTOR.
Condition: Unknown
Due 12 August 1992
Resolved 27 August 1992
Navigation
Issued 16 September 1991 Resolved
PROVIDE MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 16 October 1991
Resolved 7 October 1991
Lifesaving
Issued 16 September 1991 Resolved
PROVIDE NEW BATTERY FOR EPIRB.
Condition: Unknown
Due 16 October 1991
Resolved 7 October 1991
Deck/Cargo
Issued 16 September 1991 Resolved
PROVIDE SCREWS ON GUARD TO ANCHOR WINDLESS MOTOR.
Condition: Unknown
Due 16 October 1991
Resolved 7 October 1991
Deck/Cargo
Issued 16 September 1991 Resolved
SUBMIT HAZARDOUS LOCATION PLANS TO USCG MARINE SAFETY CENTER FOR THAT OFFICE'S REVIEW.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Construction/Loadline
Issued 16 September 1991 Resolved
REPAIR CRACKED WELD ON MAIN DECK AFT PORT OF VSL IN WAY OF HAND RAIL.
Condition: Unknown
Due 16 October 1991
Resolved 7 October 1991
Navigation
Issued 16 September 1991 Resolved
PROVE OPERATION OF SINGLE SIDE BAND (SSB) RADIO, VSL IS RESTRICTED TO OPERATION NO FURTHER THAN 20 NM FROM SHORE.
Condition: Unknown
Due 16 October 1991
Resolved 15 October 1991
Lifesaving
Issued 16 September 1991 Resolved
REMOVE COILED LINES FROM AROUND WATER LIGHT TO PROVIDE FLOAT FREE OPERATION.
Condition: Unknown
Due 16 October 1991
Resolved 7 October 1991
Deck/Cargo
Issued 16 September 1991 Resolved
ADD PRESSURE/VACUUM VALVES TO THE CARGO TANKS.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Fire Fighting
Issued 29 August 1990 Resolved
HYDRO VESSEL FIRE HOSES TO 100 PSI.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Engineering
Issued 29 August 1990 Resolved
PROVIDE GUARDS FOR FUEL OIL REMOTE SHUT-OFFS TO ENSURE DECK PLATES WILL NOTINTERFERE WITH THEIR OPERATION.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Engineering
Issued 29 August 1990 Resolved
DEMONSTRATE PORT DAY TANK FUEL SHUT-OFF.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Electrical
Issued 29 August 1990 Resolved
DEMONSTRATE PORT GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Electrical
Issued 29 August 1990 Resolved
PROPERLY INSTALL TRANSDUCER WIRING IN A/C CLOSET; I.E. REMOVE EXCESS CABLE AND INSTALL JUNCTION BOXES AT SPLICES, WHERE NECESSARY.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Navigation
Issued 29 August 1990 Resolved
INSTALL NAVIGATION LIGHT PANEL WHICH MEETS THE REQUIREMENTS OF 46 CFR 111. 75-17. [THE REQUIREMENTS OF 111.75-17(A) ARE NOT APPLICABLE, AS 112.05-5(A)DOES NOT REQUIRE A FINAL EMERGENCY POWER SOURCE ON THIS VESSEL.] SUBMIT PLANS BY 30SEP90. COMPLET INSTALLATION WITHIN 30 DAYS OF PLAN APPROVAL.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Accommodation/Occupational Safety
Issued 29 August 1990 Resolved
INSTALL ENGINE ROOM STAIRWAY HAND RAIL.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Construction/Loadline
Issued 29 August 1990 Resolved
PERMANENTLY REPAIR TWO FRACTURES IN STEERING FLAT, STARBOARD SIDE, IN WAY OF AFT BULKHEAD AND LAST FRAME. PROVIDE REPAIR PROPOSAL FOR FULL PENETRA- TION WELDING PRIOR TO PROCEEDING.
Condition: Unknown
Due 29 August 1990
Resolved 29 August 1990
Documentation
Issued 20 September 1989 Resolved
PROVIDE AND POST NEW APPROVED, UP TO DATE STABILITY LETTER.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Fire Fighting
Issued 20 September 1989 Resolved
SUBMIT FOR REVIEW AND APPROVAL A REVISED FIRE AND SAFETY PLAN.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Documentation
Issued 20 September 1989 Resolved
PROVIDE COPIES OF APPROVED MSC PLANS AS IDENTIFIED IN COAST GUARD MARINE SAFETY OFFICE SAN FRANCISCO'S LETTER #16711, DATED 19SEP89.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Deck/Cargo
Issued 12 October 1988 Resolved
REPLACE PORT DAY TANK FLAME SCREEN.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Lifesaving
Issued 12 October 1988 Resolved
PROVIDE 4 ADDITIONAL EXPOSURE SUITS, FOR A TOTAL OF 18.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Accommodation/Occupational Safety
Issued 12 October 1988 Resolved
INSTALL PROPER POTABLE WATER VENT ON STARBOARD POTABLE WATER TANK.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Documentation
Issued 12 October 1988 Resolved
OBTAIN CURRENT ABS LOADLINE CERTIFICATE.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Construction/Loadline
Issued 12 October 1988 Resolved
MARK VESSEL NAME ON BOW OF VESSEL AND VESSEL NAME AND HOMEPORT ON STERN TO REFLECT VESSEL NAME CHANGE.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Engineering
Issued 12 October 1988 Resolved
PROVE PROPER OPERATION OF P/S MAIN ENGINE OVERSPEED TRIPS AS REQUIRED BY 46 CFR 58.05-1(A) AND ABS RULE 34.11.6.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Navigation
Issued 12 October 1988 Resolved
UPDATE NAVIGATION CHARTS WITH COAST GUARD NOTICE TO MARINER'S CHANGES.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Electrical
Issued 12 October 1988 Resolved
PROVE PROPER OPERATION OF P/S GENERATOR OVERSPEED TRIPS SET IAW 46 CFR 111.12(B).
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Electrical
Issued 12 October 1988 Resolved
PROPERLY SECURE BATTERY BOXES FOR #1SSDG AND GENERAL ALARM PRESENTLY ADRIFTIN ENGINEROOM.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Lifesaving
Issued 12 October 1988 Resolved
LABEL EXPOSURE SUITS AND RESCUE BOAT WITH VESSEL NAME.
Condition: Unknown
Due 12 October 1988
Resolved 12 October 1988
Navigation
Issued 3 September 1987 Resolved
UPDATE MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Documentation
Issued 3 September 1987 Resolved
BRING VESSEL'S DOCUMENTATION IN LINE WITH HOMEPORT AND OWNERSHIP CHANGES.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Engineering
Issued 3 September 1987 Resolved
REPAIR MAIN ENGINE EXHAUST LEAKS.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Engineering
Issued 3 September 1987 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE STARBOARD MAIN ENGINE OVERSPEED TRIP.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Documentation
Issued 21 December 1984 Resolved
PROVIDE PROPER FUEL OIL TRANSFER PROCEDURES. DESIGNATE THE PERSON IN CHARGE.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Deck/Cargo
Issued 21 December 1984 Resolved
REWELD FRACTURED WELDS ON INBOARD SIDE OF SWASH BULKHEADS IN NUMBER 4 PORT CARGO WATER TANK.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Navigation
Issued 21 December 1984 Resolved
REPAIR ALL STEERING AND ENGINE ALARM LIGHTS IN PILOTHOUSE.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984

Casualty record · 1

29 June 2017Routine · role: Sighted in Area · serious marine incident, as classified · 2 dead · activity 6198783
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.