Inspection history · 17
16 March 2022
COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7448554
6 April 2021
Spot Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7171034
1 December 2020
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7104647
13 November 2020
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7100870
5 March 2020
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6928258
25 July 2019
Deficiency Check · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6766522
19 June 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6719546
9 May 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6683786
1 May 2019
COC-MODU Renew
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6670185
7 June 2018
COC-MODU Annual
Type not classified · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6438372
30 March 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6388228
9 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6368974
17 October 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6289376
22 August 2017
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6274484
20 April 2017
COC-MODU Renew · Deficiency Check · PI Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6129580
14 May 2016
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5876790
25 January 2016
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5811274
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 22 November 2020
Resolved
Crane tests should be witnessed and verified by an officer of the administration or duly authorized person or organization. A record of these exams, tests and certifications should be readily available. No flag/class crane testing acceptance was
onboard. Provide flag crane testing acceptance.
79 MODU Code 12.1.5
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2020
Resolved 25 November 2020
Resolution: Received flag dispensation from Liberia for the 5 year inspections to be extended 23MAY2021 with stipulations.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2020
Resolved
The emergency equipment provided, shall be maintained in good condition. The firemain pipe in the machine shop has a leak. Make repairs to the piping.
33CFR 146.15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2020
Resolved 22 November 2020
Resolution: Received ABS survey and witnessed satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 November 2020
Resolved
Corridor bulkheads, including doors should be A or B class divisions. Multiple fire doors in the accomodation spaces, and MCC do not fully close. Make repairs/prove proper operation.
79 MODU Code 9.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2020
Resolved 22 November 2020
Resolution: Received ABS survey and witnessed satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 November 2020
Resolved
An automatic fire detection and alarm system should be provided. A trouble alarm for E-gen heat detector is present. Repair and verify operation.
79 MODU Code 9.7.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2020
Resolved 22 November 2020
Resolution: Received ABS and witnessed satisfactory repairs.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 13 November 2020
Resolved
Each crane should be examined at intervals not exceeding 12 months, and certified at intervals not exceeding 4 years. Current exam/certification exceeds requirement. Conduct exam and certification IAW regulations.
79 MODU Code 12.1.5
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2020
Resolved 22 November 2020
Resolution: Received flag state documentation authorizing 5 years in lieu of 4 years.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 November 2020
Resolved
The EEP must be resubmitted for approval when substantive changes are made. The current EEP onboard does not have an approval from the Coast Guard.
33 CR 146.140(c)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2020
Resolved 22 November 2020
Resolution: The company has resubmitted the EEP for OCMI approval.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2019
Resolved
Fire hoses should be of material approved by the Administration, and fire hoses should be kept ready for use. While testing fire pump, one of the fire hoses has a hole in it. Conduct pressure test of remaining hoses.
'79 MODU Code 9.4.3.2.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 29 May 2019
Resolution: Email by OIM rectifying the situation.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 May 2019
Resolved
The Master or PIC shall ensure that each lifeboat is lowered to the water, launched, and operated at least once each three months as part of a boat drill required by 46 CFR 109.215. No documents showing lowering this quarter. Provide proof that lifeboats were lowered.
33 CFR 146.205(c)
46 CFR 109.217(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 29 May 2019
Resolution: Email by OIM rectifying the situation. Launches are being performed and they are passing appropriate launching definition and quarterly interpretation.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 May 2019
Resolved
Each unit should be provided with a rescue boat approved by the Administration. No proof was provided that shows the lifeboat is also approved as a rescue boat. Provide proof that a required rescue boat is onboard.
'79 MODU Code 10.2.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 12 August 2019
Resolution: Contact from flag and Compliance MGR with data plate after new boat was placed onboard as LB/RB.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 May 2019
Resolved
Where penetrations of watertight bulkheads are necessary for access..arrangements should be made to maintain the watertight integrity of the enclosed compartments. Multiple watertight doors did not seal properly. Provide proof that all doors have adequate closure to meet stability requirements.
'79 MODU Code 3.6.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 29 May 2019
Resolution: Statement by OIM showing each of the doors have been adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 June 2018
Resolved
fire pumps were not able to make adequate pressure at the nozzle due to one booster pump being out of service. Unit personnel were unaware of how long lift pump was out of service. Unit to provide stand-by vessel with fire fighting capabilities until lift pump is back in service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2018
Resolved 8 July 2018
Resolution: Email recieved from OIM stating def had been cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 June 2018
Resolved
Multiple machinery shut-downs failed to operate or could not be demostrated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2018
Resolved 8 June 2018
Resolution: email from OIM stating defs had been cleared.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 30 March 2018
Resolved
Windows which face the drill floor should be fitted with steel or equivalent material. The windows facing the drill floor in the galley were cracked.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2018
Resolved 7 June 2018
Resolution: Marine Inspectors verified these were cleared during annual examination.
Operations/Management › Vessel Activity › Other
Issued 30 March 2018
Resolved
Each crane should be designed in accordance with the requirements of a recognized classification society or with national standards. Crane windows are cracked and not in accordance with API RP 2D.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2018
Resolved 7 June 2018
Resolution: Marine Inspectors verified these were cleared during annual examination.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 30 March 2018
Resolved
Fire integrity of bulkheads should be as prescribed in tables 3 & 4 from the Code. Galley shutters do not completely seal and shut and may not prevent the passage of smoke and flame.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2018
Resolved 7 June 2018
Resolution: Marine Inspectors verified these were cleared during annual examination.
Fire Fighting › Fire Pumps › Power Source
Issued 8 May 2017
Resolved
One fire pump is required to operate while vessel is on emergency power. Fire pump does not operate while on emergency power.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 May 2017
Resolution: Fire pump repaired as required.
Communications › Public Address System › Loudspeaker
Issued 8 May 2017
Resolved
PA system did not operate while vessel was on emergency power.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 May 2017
Resolution: PA system was repaired.
Construction/Loadline › Hull › Hull Plating
Issued 8 May 2017
Resolved
Two MCT boxes had holes caused by wastage. Boxes penetrated the hull.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 May 2017
Resolution: Wasted areas were temporarily patched with doubler plates.
Operations/Management › Drills/Instruction › Fire
Issued 20 April 2017
Resolved
Unit personnel failed to satisfactorly execute fire drill showing a lack of proper training.
79 MODU / 10.6.3
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: Satisfactory drill was witnessed by attending CG inspectors.
Documentation › Logs/Records › Oil Record Book
Issued 20 April 2017
Resolved
Multiple incorrect entries were discovered in ORB Part 1. ORB was found to have multiple inconsistencies in recording events required by regulation.
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: ORB entries were made correctly. Additional instructions were added to ORB.
Electrical › Electric Generation Source (emergency) › Generator
Issued 20 April 2017
Resolved
Air reciever for E-Gen was located outside space. There was no provision for a non-return vavle inside E-gen space for isolation form main air supply. 79 MODU / 5.4.3.3
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: New check valve was installed inside of E-gen space.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 20 April 2017
Resolved
Mnultiple waste drums were found rusted and wasted creating a enviromental and personnel hazard. 79 MODU / 14.2.1
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Hazardous waste materials were removed and area cleaned.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 April 2017
Resolved
Multiple stair tower doors were found to be noe self closing or latching. 79 MODU / 9.2.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Fire doors repaired as required.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 20 April 2017
Resolved
Multiple external doors in superstructure were found inoperable or not self closing. 79 MODU / 9.1.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Fire doors repaired as required.
Electrical › Electrical Distribution System (service) › Conductor
Issued 20 April 2017
Resolved
Hazardous electrical splices were found on and near welder. 79 MODU / 5.1.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Welding machine wires repaired as required.
Lifesaving › Lifeboat › Markings
Issued 20 April 2017
Resolved
Survival craft were found to be incorrectly marked. 79 MODU / 10.1.4
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Lifeboat markings were completed.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 20 April 2017
Resolved
Survival craft equipment was found to be stored on seats limiting the use of those seats and reducing capacity of survival craft. 79 MODU / 10.1.1
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Lifeboat equipment was stored appropriately.
Engineering › Pressure Vessel › Relief Valve
Issued 20 April 2017
Resolved
EDG pressure relief vavle was found to be leaking by thus preventing pressure vessel from holding pressure. 79 MODU / 4.2.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: New pressure relief valve was installed.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 20 April 2017
Resolved
Oily rags were found to be not properly disposed of and stored in plastic waste bins. 79 MODU / 14.2.4
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 May 2017
Resolution: Oily rags were removed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 April 2017
Resolved
Numerous lights were found extinguished. 79 MODU / 5.3.2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: E-lights were repaired as required.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 20 April 2017
Resolved
Unit did not have a satisfactory wast management plan. This was shown through the incorrect disposal of oily soaked rags.
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: Approved waste management team was provided.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 20 April 2017
Resolved
Multiple cable penetrations were improperly installed. 79 MODU / 3.6.1 & 79 MODU / 9.1.3.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: MCTs were repaired as required.
Communications › Visual Communication › Red Warning Signal
Issued 20 April 2017
Resolved
Unit's wind direction indicator was obstructed. 79 MODU / 13.4.1
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: New wind socks were installed.
Fire Fighting › Water Fog Applicators › Condition
Issued 20 April 2017
Resolved
Numerous low velocity fog applicators unable to affix to fire hose combination nozzles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: Proper applicators were installed.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 20 April 2017
Resolved
Ventilator opening above door to storeroom unable to be dogged shut. 79 MODU / 9.10.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 May 2017
Resolution: Closure was repaired as required.