MAURY USCG vessel records Sign in
← All vessels

MR. BICE *

MR. BICE * is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 52 inspections since 1984, most recently in December 1998, along with 98 deficiencies and 1 casualty investigation in 1998.

Records from 1984 to 1998. Most recent: inspection, 14 December 1998.

Built
1982
Last inspected
14 December 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBK2904
Flag
UNITED STATES
—
Maury page id
psix-54479

Inspections, by type

…with no type recorded14
Years with a record 15 calendar years (1984–1998)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2741 - Regulatory (Subpart C or D), Gross Ton
2181 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBK2904MMSI not assigned · expired · compulsorily equipped · granted 2 September 1997, cancelled 3 November 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CROSBY TRINITY Towing Vessel · MISLE 143477 · 25 June 1998 · activity 120000CROSBY LIBERTY Towing Vessel · MISLE 202332 · 25 June 1998 · activity 120000

Inspection history · 52

14 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807751
25 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120000
8 June 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467993
31 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124567
4 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783465
19 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1108538
6 August 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418219
21 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115607
4 June 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774402
21 May 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388280
16 May 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1091761
11 December 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093374
23 September 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 826480
11 July 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390296
28 June 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246063
10 May 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082705
8 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877036
25 October 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184732
20 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188594
7 June 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407497
11 April 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1155669
24 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 827130
14 September 1994 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1401921
7 June 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382787
13 March 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 169897
28 February 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 156169
1 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 852021
9 July 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449624
9 November 1992 Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963179
15 August 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1252219
23 July 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1244225
9 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211177
14 November 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927884
6 September 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906490
13 August 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 905137
6 July 1990 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1231951
7 April 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909586
8 January 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919786
28 September 1989 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1214016
28 September 1989 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1222826
8 September 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 893178
24 May 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1352331
4 January 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040580
12 December 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034562
6 November 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315839
20 August 1987 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1006800
21 May 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1305390
16 December 1985 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 998414
13 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983868
21 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290058
14 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285894
13 August 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281484

Deficiency record · 98

Unknown
Issued 6 August 1997 Resolved
SUBMIT REPAIR PROPOSAL AND COMPLETE REPAIRS TO #2,3 AND 4 LEG-TO-MAT CONNECTIONS; SUBMIT FINAL REPORTS ON REPAIRS FROM ABS &/OR NDE 3rd PARTY COMPANY AS APPLICABLE TO [name withheld].
Condition: Unknown
Due 15 August 1997
Resolved 15 August 1997
Unknown
Issued 6 August 1997 Resolved
SUBMIT DIVER'S REPORT AND VIDEO OF UNDERWATER NDE OF LEG-TO-MAT CONNECTIONSTO [name withheld].
Condition: Unknown
Due 10 September 1997
Resolved 10 September 1997
Construction/Loadline
Issued 21 May 1997 Resolved
RENEW WASTED DECK FRAMING THROUGHOUT RIG AS NECESSARY; PARTICULARLY RENEW LANDINGS ADJACENT TO EACH LIFEBOAT AND GRATES/FRAMING BELOW AIR CONDITIONERUNITS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997 Resolved
CONDUCT NONDESTRUCTIVE TESTING OF LEG-TO-MAT CRITICAL CONNECTIONS IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Accommodation/Occupational Safety
Issued 21 May 1997 Resolved
RENEW WASTED HANDRAILS THROUGHOUT RIG AS NECESSARY. SUBMIT COMPLETE LIST OF RENEWED RAILINGS TO [name withheld].
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Deck/Cargo
Issued 21 May 1997 Resolved
CROP AND RENEW WASTED SECTION OF LOW SUCTION MUD PIPING IN MUD PUMP ROOM.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Accommodation/Occupational Safety
Issued 21 May 1997 Resolved
RENEW WASTED VENTILATION DUCTING AND VENT DOGS THROUGHOUT RIG AS NECESSARY.SUBMIT COMPLETE LIST OF REPAIRS TO [name withheld].
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Fire Fighting
Issued 21 May 1997 Resolved
RENEW WASTED FIREMAIN PIPING AT FIRE STATION NO. 6.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Accommodation/Occupational Safety
Issued 21 May 1997 Resolved
INSTALL 100 PSI RELIEF VALVES ON HOT WATER HEATERS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Fire Fighting
Issued 11 July 1996 Resolved
CALIBRATE GAS DETECTORS FOR FIREMAN'S OUTFITS.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Navigation
Issued 11 July 1996 Resolved
REPLACE BULBS IN PORT AND STBD. NAV. LIGHTS ON OR BEFORE COMPLIANCE DATE AND/OR PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Lifesaving
Issued 11 July 1996 Resolved
REPAIR LIMIT SWITCHES ON PORT AND STBD. LIFEBOATS; ADJUST BRAKE ON STBD. LIFEBOAT.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Lifesaving
Issued 11 July 1996 Resolved
PROVIDE GENERAL ALARM BELL OR ROTATING LIGHT IN UPPER SHAKER HOUSE.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Documentation
Issued 11 July 1996 Resolved
PROVIDE OIL POLLUTION PLACARD.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Fire Fighting
Issued 7 June 1995 Resolved
ADJUST OR REPAIR DOOR FROM MUD PIT TO MUD PUMP ROOM SO AS TO BE SELF CLOSING AND GAS TIGHT.
Condition: Unknown
Due 29 June 1995
Resolved 29 June 1995
Construction/Loadline
Issued 14 September 1994 Resolved
UPON COMPLETION OF LOWER MAT EXAM AND LEG TO MAT CRITICAL CONNECTIONS EXAM SUBMIT ABS AND DIVER REPORTS FOR REVIEW.
Condition: Unknown
Due 14 September 1994
Resolved 14 September 1994
Construction/Loadline
Issued 14 September 1994 Resolved
COMPLETE PHASE II OF SEILOD INSPECTION AS PER BROUGHTON OFFSHORE DRILLING LTR DATED 07SEP94. UPPER HULL PORTION COMPLETED 14SEP94. LOWER MAT SWIM BY AND LEG TO MAT CRITICAL CONNECTIONS REMAIN OUTSTANDING. THIS ITEM TO BECOMPLETED AT NEXT RIG MOVE PRIOR TO NEW DRILLING OPERATIONS.
Condition: Unknown
Due 15 December 1994
Resolved 8 December 1994
Electrical
Issued 9 July 1993 Resolved
REMOVE WIRE SPLICES IN VICINITY OF SHALE SHAKERS._x001C_
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Fire Fighting
Issued 9 July 1993 Resolved
REPLACE FIRE EXTINGUISHER BRACKETS AT EMERGENCY GENERATOR AND QTRS 01 DECK.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Engineering
Issued 9 July 1993 Resolved
REPAIR AS NECESSARY AND TEST ENGINE SAFETIES AND REVERSE POWER TRIP GENSET NO. 1.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Lifesaving
Issued 9 July 1993 Resolved
REPLACE ALL WINDOWS ON BOTH LIFEBOATS.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Construction/Loadline
Issued 9 July 1993 Resolved
PROVE PROPER OPERATION OF BILGE PUMP.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Construction/Loadline
Issued 9 July 1993 Resolved
CLEAN ALL BILGES.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Electrical
Issued 9 July 1993 Resolved
PROPERLY DEAD END CABLES OVER CEMENT AND BARITE TANKS.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Electrical
Issued 9 July 1993 Resolved
CONDUCT RIG SHUTDOWN AND TEST EMERGENCY POWER.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Electrical
Issued 9 July 1993 Resolved
REMOVE NON-EXPLOSION-PROOF BOX BY SHALE SHAKERS.
Condition: Unknown
Due 26 July 1993
Resolved 26 July 1993
Deck/Cargo
Issued 23 July 1991 Resolved
CONDUCT INTERNAL EXAM ON THE FOLLOWING BULK TANKS: 2 & 3 CEMENT AND 1,2 & 3BARITE.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Electrical
Issued 23 July 1991 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN AND AUTOMATIC BUS TRANSFER FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Lifesaving
Issued 23 July 1991 Resolved
PROVIDE PROOF OF CERTIFICATION FOR LIFEBOAT (#1 AND #2) WIRE ROPE FITTINGS AND DATES OF INSTALLATION.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Electrical
Issued 23 July 1991 Resolved
REPLACE BROKEN GLASS ON EXPLOSION PROOF "E" LIGHT IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Deck/Cargo
Issued 23 July 1991 Resolved
PROVE PROPER OPERATION OF RIG SHUT DOWN.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Lifesaving
Issued 23 July 1991 Resolved
PROVIDE TWO APPROVED CHAIN EMBARKATION LADDERS, ONE AT EACH LIFEBOAT STATION.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Electrical
Issued 23 July 1991 Resolved
RETAG OR PROVIDE GUARD FOR GENERATOR EXHAUST THAT IS MISSING ON MAINDECK.
Condition: Unknown
Due 23 July 1991
Resolved 23 July 1991
Electrical
Issued 6 September 1990 Resolved
PROVIDE LOSS OF PURGE ALARMS IN ACCORDANCE WITH NFPA-496 FOR HEITMAN PIT VOLUME TOTALIZER PANEL ON RIG FLOOR, Z PURGE REQUIRED FOR CLASS I DIVISION II LOCATION (PURGE ALARM CANNOT BE ACTIVATED BY DOOR SWITCH.0
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Fire Fighting
Issued 6 September 1990 Resolved
REPLACE 2 EACH 2 1/2" DIAMETER ALL PURPOSE NOZZLES.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
PROVIDE LOSS OF PURGE ALARMS IN ACCORDANCE WITH NFPA-496 FOR HEITMAN GAS DETECTOR PANEL ON RIG FLOOR. NOTE: Z PURGE REQUIRED FOR CLASS I DIVISION II LOCATION (PURGE ALARM CANNOT BE ACTIVATED BY DOOR SWITCH.)
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
REPLACE MISSING BOLTS ON EXPLOSION PROOF PHONE BOX, LOWER SHAKER.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
REPLACE WIRING WITH BROKEN ARMOR TO BOTH EXPLOSION PROOF SWITCH BOXES TO MOTOR WIRE RUNS IN UPPER SHAKER UNITS.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
REPLACE MISSING BOLTS TO EXPLOSION PROOF SWITCH BOXES (UPPER SHAKER CON- ROLS).
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
PROPERLY GROUND , CHECK FOR GROUNDING OF POWER SUPPLY LIGHT LOCATED ABOVE UPPER AFT SHAKER.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Lifesaving
Issued 6 September 1990 Resolved
REPLACE BOTH HYDRUALIC GUAGES FOR PORT BOAT AND 1 IN STARBOARD BOAT.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Deck/Cargo
Issued 6 September 1990 Resolved
REPLACE BROKEN FLAME SCREEN ON EMERGENCY FUEL TANK FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
REPAIR FOLLOWING GENERATOR ALARM BELLS, MAIN DECK PORT SIDE BY COMPRESSOR ROOM ACCESS; PORT CRANE PEDESTAL, STARBOARD CRANE PEDESTAL, STARBOARD AFT LEG, GALLEY ACCESS INTERIOR.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
PROVIDE EXPLOSION PROOF JUNCTION BOX FOR SWACO STROKE RATE METER LOCATED ON RIG FLOOR.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Electrical
Issued 6 September 1990 Resolved
REPAIR BATTERY POWERED "E" LIGHT IN MUD PITS.
Condition: Unknown
Due 6 September 1990
Resolved 6 September 1990
Construction/Loadline
Issued 28 September 1989 Resolved
COMPLETE UNDERWATER PORTION OF SPECIAL EXAM IN LIEU OF DRYDOCK EXAMINATION AT NEXT RIG MOVE.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Accommodation/Occupational Safety
Issued 8 September 1989 Resolved
CONDUCT SETTING OF SIX BULK AND THREE AIR RECIEVER RELIEF VALVES.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Documentation
Issued 8 September 1989 Resolved
PROVIDE ON BOARD AN APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Accommodation/Occupational Safety
Issued 8 September 1989 Resolved
CONDUCT INTERNAL EXAMINATION OF ALL THREE SHIP SERVICE AIR RECEIVERS.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Fire Fighting
Issued 4 January 1989 Resolved
PROVIDE REQUIRED HALON 1301 FOR EMERGENCY GENERATOR SPACE, SCR/MLC ROOM AND PUMP ROOM AS PER COI.
Condition: Unknown
Due 4 January 1989
Resolved 4 January 1989
Electrical
Issued 12 December 1988 Resolved
CORRECT THE OVER SPEED DEVICE ON THE EMERGENCY GENERATOR. MUST OPERATE BELOW 2035 RPMS.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988 Resolved
SHOW PROPER OPERATION OF THE AUTO BUS TRANSFER OF EMERGENCY GENERATOR
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988 Resolved
PLACE THE RUBBER MAT IN THE SWITCH BOARD AREA IN THE EMERGENCY GENERATOR ROOM. (THE ONE WHICH IS PRESENT IS TOO SMALL IN AREA COVERED.)
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Documentation
Issued 12 December 1988 Resolved
REPLACE FIRE CONTROL PLAN ON MESS DECK WITH ONE THAT IS LEGIBLE. (MUST BE THE SAME AS APPROVED DRAWING OUTSIDE TOOL PUSHERS OFFICE).
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Unknown
Issued 12 December 1988 Resolved
COMPLETE STENCILING GENERAL ALARM BELLS THROUGHOUT THE RIG. GENERAL ALARM "WHEN BELL RINGS GO TO YOUR STATION".
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988 Resolved
COMPLETE REPAIRS TO TEMPORARY POWER SOURCE EMERGENCY LIGHTS.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Unknown
Issued 12 December 1988 Resolved
STENCIL THE GATE VALVE ON THE GENERATOR ROOM DAY TANK "REMOTE FUEL SHUT DOWN FOR GENERATOR ROOM"
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988 Resolved
PROVIDE VISUAL OR AUDIBLE PURGE ALARM ON THE TOTCO CRT MONITOR ON DRILL FLOOR IN ACCORDANCE WITH NFPA 496 SECTION 2-3.3.1. PROVIDE VISUAL CHECK ANDLOG EVERY 30 MINUTES UNTIL REPAIRED.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Deck/Cargo
Issued 12 December 1988 Resolved
REPLACE ALL DETERIORATED FLAME SCREENS ON OIL TANK VENTS.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988 Resolved
PROVIDE INSTRUMENT QUALITY AIR FOR ALL PURGING SYSTEMS. AIR CURRENTLY CONTAINS EXCESS OIL VAPORS AS EVIDENCED BY COLLECTION OF OIL IN PURGED EQUIPMENT. NFPA 496 SECTIONS 2-206 AND 2-2.6.1.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988 Resolved
PROVIDE VISUAL OR AUDIBLE ALARM FOR THE DRILLERS CONSOLE. ALARM SHOULD BE LOCATED IN AN AREA "WHERE IT CAN READILY BE SEEN OR HEARD" (NFPA 496 SEC. 2-3.3.1.) VISUALLY CHECK AND LOG EVERY 30 MIN UNTIL CORRECTED.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Electrical
Issued 12 December 1988 Resolved
PROVIDE A VISUAL OR AUDIBLE ALARM FOR NON-EXPLOSION PROOF JUNCTION BOX LOCATED IN REAR OF DRILL FLOOR AND DRILLER SHACK IN ACCORDANCE WITH NFPA 496 SECTION 2-3.3.1. VISUALLY CHECK PURGE AND LOG EVERY 30 MINUTES UNTIL REPAIRED.
Condition: Unknown
Due 12 December 1988
Resolved 12 December 1988
Fire Fighting
Issued 16 December 1985 Resolved
REPAIR/REPLACE OXYGEN-EXPLOSIVEMETERS (2) AND PLACE ONBOARD RIG
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Fire Fighting
Issued 16 December 1985 Resolved
PROVIDE SPARE OXYGEN BOTTLES FOR THE TWO(2) REQUIRED SCBA UNITS
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Unknown
Issued 16 December 1985 Resolved
PROVIDE AND MAINTAIN MASTER'S LOGS IN ACCORDANCE WITH 46 CFR 109.433
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Accommodation/Occupational Safety
Issued 16 December 1985 Resolved
REPAIR CREW QUARTERS VENTILATION SHUTDOWN AT BOTH REMOTE STATIONS
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 16 December 1985 Resolved
REPLACE ALL WINDOWS IN #1 AND #2 LIFEBOATS
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Fire Fighting
Issued 16 December 1985 Resolved
PROVIDE SPARE PORTABLE EXTINGUISHERS AS FOLLOWS: 4 A-II; 2-BCI
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 16 December 1985 Resolved
PROVIDE A TABLE OF LIFESAVING SIGNALS FOR EACHH LIFEBOAT
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 16 December 1985 Resolved
REPAIR WATER SPRAY SYSTEM ON #2 LIFEBOAT
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Fire Fighting
Issued 16 December 1985 Resolved
PROVIDE 3 CELL FLASHLIGHT FOR CHANGE ROOM FIREMANS OUTFIT.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Navigation
Issued 16 December 1985 Resolved
INSTALL CORRECT BULBS IN ALL NAVIGATION LIGHTS
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 16 December 1985 Resolved
MOUNT FORWARD EXTINGUISHER IN #1 BOAT
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 21 April 1985 Resolved
PROVIDE OPERATING MANUALS FOR THE LIFEBOATS. 46 CFR 109.217(B).
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Lifesaving
Issued 21 April 1985 Resolved
FREE UP THE ACCESS DOORS IN THE BULLWORK FOR THE PORT AND STARBOARD EMBARKATION LADDERS. 46 CFR 108.151.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Lifesaving
Issued 21 April 1985 Resolved
RERIG THE HAND RELEAVING WIRE FOR THE PORT AND STARBOARD LIFEBOAT WINCH, ASSHOWN IN THE OPERATING MANUAL FOR THE LIFE BOATS. 46 CFR 108.507.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Construction/Loadline
Issued 21 April 1985 Resolved
MAKE AVAILABLE FOR INSPECTION THE MAIN SEA SUCTION VALVE LOCATED AT THE SEACHEST. 46 CFR 107.261.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Construction/Loadline
Issued 21 April 1985 Resolved
REPLACE THE FRACTURED AND ADRIFT DIAGONAL SUPPORT TRUSS FOR THE STATIONARY CANTLIVER BEAM LOCATED IN THE PORT SIDE OF THE MAIN DECK IN WAY OF THE DRILLING SLOT. 46 CFR 108.113.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Construction/Loadline
Issued 21 April 1985 Resolved
REPLACE THE BENT UPPER GUSSET PLATE IN WAY OF THE DIAGONAL SUPPORT AS NOTEDIN ITEM 7. 46 CFR 108.13.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Construction/Loadline
Issued 21 April 1985 Resolved
MAKE AVAILABLE FOR EXTERNAL INSPECTION THE HULL BOTTOM SHELL PLATING. 46 CFR 107.261.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Unknown
Issued 21 April 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU ROBERT N HASKIN DN650829.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Fire Fighting
Issued 21 April 1985 Resolved
REPLACE THE MISSING FOG APPLICATOR AT THE HELO DECK FIRE HYDRANT. 46 CFR 107.477
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Lifesaving
Issued 21 April 1985 Resolved
REPLACE THE BROKEN CABLE ON THE WINCH FOR THE STARBOARD BOW EMBARKATION LADDER. 46 CFR 108.525.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Lifesaving
Issued 21 April 1985 Resolved
REPLACE THE MISSING WINCH CRANK HANDLE ON THE PORT BOW EMBARKATION LADDER. 46 CFR 108.525.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Construction/Loadline
Issued 21 April 1985 Resolved
MAKE REPAIRS TO THE DAMAGED GOOSE NECK VENT FOR THE STARBOARD POLLUTION TANK, T-22-2. 46 CFR 108.113.
Condition: Unknown
Due 21 April 1985
Resolved 21 April 1985
Fire Fighting
Issued 13 August 1984 Resolved
PROVIDE APPROVED APPLICATORS FOR ALL MACHINERY SPACE FIRE HOSE STATIONS.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Lifesaving
Issued 13 August 1984 Resolved
RENEW KINKED CABLE ON THE STBD DAVIT LAUNCHED DAVIT AND WEIGHT TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. PENDINDING SATISFACTORY COMPLE-
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Documentation
Issued 13 August 1984 Resolved
SUBMIT FOR APPROVAL TO THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION THE VESSEL FIRE CONTROL PLAN.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Lifesaving
Issued 13 August 1984 Resolved
REINSTALL THE RING LIFE BOUYS WITH SMOKE AND WATERLIGHT SO AS TO ALLOW PROPER DEPLOYMENT.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Documentation
Issued 13 August 1984 Resolved
PROVIDE ON BOARD THE VESSEL THE COAST GUARD APPROVED OPERATION MANUAL.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Fire Fighting
Issued 13 August 1984 Resolved
PROVIDE ON BOARD THE VESSEL TWO UL OR FM LISTED COMBUSTIBLE GAS/ OXYGEN METERS FOR THE FIREMANS OUTFITS.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Deck/Cargo
Issued 13 August 1984 Resolved
PROVIDE SUITABLE GUARDS FOR ALL AIR TUGGERS.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Unknown
Issued 13 August 1984 Resolved
PROVIDE ON BOARD THE VESSEL TWO ADDITIONAL CERTIFICATED LIFEBOATMEN. PEND- ING COMPLETION OF THIS REQUIREMENT, TOTAL PERSONS ALLOWED SHALL NOT EXCEED
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Electrical
Issued 13 August 1984 Resolved
REPAIR OR RENEW GENERAL ALARM BELL IN THE AIR COMPRESSER ROOM.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Engineering
Issued 13 August 1984 Resolved
REMOVE EXCESSIVE OIL FROM BENEATH THE GENERATORS.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Electrical
Issued 13 August 1984 Resolved
REPAIR OR RENEW ALL INOPERATIVE EMERGENCY LIGHTS.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Electrical
Issued 13 August 1984 Resolved
AIR PURGE OR REMOVE TO A NON-HAZARDOUS LOCATION THE DRETECH ELECTRIC PANEL BOX ON THE DRILL FLOOR. AIR PURGING SHALL BE IN ACCORDANCE WITH NFPA 496.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984
Electrical
Issued 13 August 1984 Resolved
PROPERLY SEAL ALL EYS FITTINGS FOR THE GAS DECTECTION SYSTEM PRIOR TO THE COMMENCEMENT OF DRILLING OPERATIONS BUT NOT LATER THAN 13SEP84.
Condition: Unknown
Due 13 August 1984
Resolved 13 August 1984

Casualty record · 1

25 June 1998Major Marine Casualty · role: Involved in a Marine Casualty · activity 120000
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record