03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 March 2026
Resolved
A hatch exposed to the weather must be watertight. MI observed lazarette hatch gasket worn. Replace the rubber gasket on the lazarette hatch to restore proper sealing and prevent water intrusion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2026
Resolved 20 March 2026
Resolution: Photos of hatch was submitted. All Sat
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 13 March 2026
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Replace the missing support in kind to restore proper structural support.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2026
Resolved 25 March 2026
Resolution: Recieved email with photos of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2025
No resolution recorded
(a) Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter... Life jackets carried on board were not equipped with required lights. Ensure all life jackets are fitted with approved lights prior to operating on a Coastwise and Oceans route.
Marine Inspector was unable to test all 60 lifejacket lights while onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolution: Route restricted to LBS/LC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported loss of propulsion to Sector New York. Must conduct satisfactory sea trial prior to the carriage of passengers.
46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2025
Resolution: In person sea trial/def checked sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2025
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Both port and starboard engine intakes were removed for maintenance due to leaks. Install intake manifolds and have sea trials done in the presence of a marine inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2025
Resolution: Both main engine heat exchangers repaired and installed. Sea trials completed to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 March 2025
Resolved
The float-free link required by § 180.130(a)(1) must be:Secured to the painter at one end and to the vessel on the other end. 46 CFR 180.137(b)(3)
Lifefloat was not connected to the float-free link.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 March 2025
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section:
(1) A space containing propulsion machinery;
46 CFR 181.400(a)(1)
Vessels engine room wasn't vapor tight which would allow CO2 to escape the space rendering the CO2 ineffective.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 March 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—
(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and
(2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
46 CFR 180.68(a)
Vessel only had 03 orange hand smoke distress signals onboard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 March 2025
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. This number must:
(1) Be the number of persons the device is equipped for; and
(2) Not be greater than the number of persons the device is approved for as shown on its nameplate.
46 CFR 185.604(e)
Lifefloat was missing number of persons capacity.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 March 2025
Resolved
If a garden hose is used, it shall be of a good commercial grade constructed of an inner rubber tube, piles of braided cotton reinforcement and an outer rubber cover or of equivalent material, and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal.
46 CFR 191.15-10(e)Old T
Vessel was equipped with a fire hose that was a garden hose with a plastic nozzle.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2025
Resolved 26 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2024
Resolved
"All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury." Vessel did not address machinery guards in a timely manner (original deficiency was provided in APR2024). Ensure the machinery guards are appropriately addressed.
46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2025
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 April 2024
Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible... Vessel did not have up-to-date charts on board.
46 CFR 184.420 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel did not have adequate first aid kit on board.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 October 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Vessel did not properly label fuel shutt-off valve.
46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2024
Resolution: POC provided photographic evidence of proper labelling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel was missing machinery guards.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2025
Resolution: POC provided satisfactory photographic evidence
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that: (7) A positive shutoff valve is installed at the hull penetration. Vessel did not have appropriate valve installed.
46 CFR 182.520(e)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2024
Resolution: Recieved photographic evidence of installed shutoff valve.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 June 2023
Resolved
THE POWER FIRE PUMP SHALL BE SELFPRIMING AND OF SUCH SIZE AS TO DISCHARGE AN EFFECTIVE STREAM FROM A HOSE CONNECTED TO THE HIGHEST OUTLET. GARDEN HOSE WAS UNABLE TO PRODUCE PRESSURE BEYOND THREE OR FOUR FEET OF DISCHARGE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2023
Resolved 21 June 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 June 2023
Resolved
A BATTERY CHARGER INTENDED FOR CONNECTION TO A COMMERCIAL SUPPLY VOLTAGE SHALL EMPLOY A TRANSFORMER OF THE ISOLATING TYPE. AN AMMETER THAT IS READILY VISIBLE SHALL BE INCLUDED IN THE BATTERY CHARGER CIRCUIT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 14 July 2023
Resolution: ProNautic 12/40P installed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 June 2023
Resolved
Regulations intent is to provide standard that minimizes risk from fire or electrical shock originating in electrical equipment. Found two unused wires in adjacent spaces that need to be removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2023
Resolved 28 June 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 September 2022
Resolved
Sector Delaware Bay has submitted information to Marine Safety Center requesting an equivalency for the excess CO2 to be considered as an equivalent level of safety for not having automatic engine shutdowns.
The owner, or owner’s representative is required to follow up and provide the Marine Safety Center with any additional information that may be needed. Vessel is required to have an equivalency approval/decision letter with in 60 days or until the equivalency approval is received by Sector Delaware Bay (whichever comes first).
705C-60 days
46 CFR 175.540(a)
46 CFR 181.410(b)(10)
Action required: 705 - Other - as specified
Due 12 November 2022
Resolved 18 November 2022
Resolution: Received equivalency from eng04/msc for the engine automatic shutdowns.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 June 2022
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions to be taken in the event of a man overboard. Vessel's crew was unfamiliar with Man Overboard procedures and did not perform drill as per emergency instructions.
Vessel is required to modify procedures to an acceptable method of performing man overboard operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2022
Resolved 1 August 2022
Resolution: made proper change to mod procedures
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 29 June 2022
Resolved
Vessel crew was unable to conduct man overboard drill due to safety concerns.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2022
Resolved 29 June 2022
Resolution: Following crew member change, vessel was able to successfully complete man overboard drill.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 June 2022
Resolved
Life floats must be approved under approval series 160.027 or other standard specified by the Commandant. Vessel's large life boat was deteriorated beyond repair. Vessel is required to replace with life float(s) capable of handling an equivalent number of persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2022
Resolved 1 August 2022
Resolution: replace life float
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 June 2022
Resolved
Fuel filter bowls must be of metallic construction. Vessel's fuel filter bowls had plastic plugs installed. Replace with steel type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 15 July 2022
Resolution: Installed metal valve and plug.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022
Resolved
All circuit breakers on board the vessel should be labeled indicating which circuit they control. Unused breakers should be removed and blanked off or labeled as spares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 15 July 2022
Resolution: Breaker panel is now labled.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 29 June 2022
Resolved
Vessels equipped with type 3 Marine Sanitation Devices must be equipped with acceptable method of securing devices. Vessel is required to install acceptable method of securing device on the overboard discharge valve to ensure no discharge is permitted when in locations where discharge of sewage is unauthorized.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 15 July 2022
Resolution: msd was chained and locked in the closed position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2022
Resolved
Battery chargers must be equipped with ammeter which is readily visible in the charging circuit. Vessel required to install readily visible ammeter on the charging circuit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 15 July 2022
Resolution: Battery charge was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022
Resolved
Lighting fixtures must have suitable covers. 02 fluorescent lighting fixtures were not equipped with appropriate covers and the bulbs were exposed. Install appropriate covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 15 July 2022
Resolution: New light with covers were installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2022
Resolved
CO2 cylinder, where subject to moisture, must be installed to provide at least 51 millimeters (2 inches) between the deck and the bottom of the storage cylinder. Adjust installation of CO2 cylinder in order to ensure the appropriate distance between the deck and the bottom of the cylinder. The bottom of the cylinder currently shows signs of increased corrosion.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2022
Resolved 12 August 2022
Resolution: Recieved documentation showing Allied fire has lifted the bottle.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 June 2022
Resolved
Employers must ensure that they and their crewmembers meet the requirements of 46 CFR 16. 01 crew member was not enrolled in Chemical Drug Testing program. Ensure enrollment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 15 July 2022
Resolution: Added Katherine Novelli to the DAPI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards and minimize accidental personnel contact with energized parts. Multiple dead end wires were identified around the vessel. Cap, or remove dead end wires as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2022
Resolved 15 July 2022
Resolution: Dead end wire are now capped.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 June 2022
Resolved
MI observed No shut downs for engine room machinery associated with the fixed Co2 system. After review of the vessels file and communications with Marine Safety Center(MSC) the vessel fixed fire extinguishing system is not approved and was never reviewed by MSC.
Vessel is required to submit plans to Sector Del Bay for Local Plan approval.
46 CFR 181.400(a)
46 CFR 181.410(b)(10)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 6 September 2022
Resolution: Unit submits plans to msc on o/o behalf.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 June 2021
Resolved
The certificate of inspection must be posted under glass all pages visible where passengers will see it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2021
Resolved 30 July 2021
Resolution: Owner submitted photo of COI posted under glass in main salon.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 June 2020
Resolved
No fuel is allowed to be carried in the 03 fuel tanks located in the steering compartment. Piping, venting, and valves are in poor condition. All tanks are currently empty of fuel. Removal or fixing of these tanks to be addressed at next Dry-Dock in Spring of 2021. 46 CFR 182.450
Action required: 10 - Deficiency Rectified
Due 30 June 2020
Resolved 30 June 2020
Resolution: Added special note to be addressed at next DD
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 June 2020
Resolved
Install fire extinguishers in the following orientation: Operating Station: 10-B:C, Accommodation Space (main deck) : 2-A, in vicinity of engine room hatch for the Machinery Space: 40-B:C. The under deck passenger lounge area is required at least a 2-A fire extinguisher. 46 CFR 181.500 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 20 July 2020
Resolution: Installed in proper order
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 30 June 2020
Resolved
Passengers are restricted from accessing the upper deck due to the rail height being 29" high instead of the the required 36". Post a sign at the ladder stating such restriction.46 CFR 177.900 (d) (3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 13 August 2020
Resolution: Picture provided of signage
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 June 2020
Resolved
"All life jackets shall be distributed through the upper part of the vessel in protected places convenient to the persons on board. If practicable, life preserver containers shall be designed as to allow the life preserver to float free. Life preservers for children shall be stowed separately". Currently almost all adult life jackets are stowed against the collision bulkhead through the under deck passenger bunk area. This must be made more accessible to passengers IAW with above statements. Propose a stowage plan for approval by a Marine Inspector with in 14 days, move life jackets to main deck accommodation space immediately until a new stowage plan is approved. 46 CFR 180.25-10
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 20 July 2020
Resolution: Life jackets were immediatly moved to main accomadation deck under bench seating. O/O is planning to create more permanant storage when he reconfigures deck space at DD.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 June 2020
Resolved
Prior to any persons sleeping in the below deck room that has bunks, the fixed CO2 system bottles and assoc. piping must be relocated. This must be completed to consider this an accommodation space for passengers or crew. Submit plans and calculations for moving the fixed system into another space. Alternatively to moving the fixed system to another space, a Marine Inspector can measure the engine room to see if vessel is eligible for a pre-engineered fire extinguisher system if space is under 2,000 cubic feet. 46 CFR 177.800
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 1 April 2021
Resolution: Space containing CO2 Cylinder and Actuator will NOT serve as passenger Accomodations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 June 2020
Resolved
Previous owner garbage management plan still posted. Create and post new garbage management plan on board. 33 CFR 151.57
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 20 July 2020
Resolution: Owner posted new garbage management plan for current ownership and dock.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 30 June 2020
Resolved
Employee Assistance Program information, including community service hot-line telephone number and employer's policy regarding drug and alcohol use in the workplace, must be provided to all crew members or posted conspicuously on board. 46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 20 July 2020
Resolution: O/O recieved information from the Maritime Consuritum and posted info.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2020
Resolved
Fire hydrant had severe leak on starboard side mid ship and no water exited the nozzle during the first test. Replace fire hose (commercial garden hose) between 25-50’ and at least 5/8” diameter. Additionally, replace nozzle with bronze or equivalent metal nozzle that is either combination or solid stream. All fittings must be brass, coper, or other suitable corrosion-resistant metal. Fire hose must be connected at fire hydrant at all times in good condition. 46 CFR 181.15-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 20 July 2020
Resolution: O/O replaced fire hose and nozzle with spare.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 June 2020
Resolved
Replace all, 03, water light batteries due either being expired or the wrong battery type. Vessel is restricted to day light only operations until this is rectified. 46 CFR 180.15-5 (d)
Action required: 705 - Other - as specified
Due 30 June 2020
Resolved 30 June 2020
Resolution: O/O bought 03 correct type batteries for waterlights
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 30 June 2020
Resolved
Install florescent light fixture covers on port and starboard engine room lights. 46 CFR 183.200 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2020
Resolved 20 July 2020
Resolution: O/O removed both lights from engine room instead of finding covers for them.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 19 September 2019
Resolved
1st aid kit missing contents such as ammonia inhalents and iodine. Inventory first aid kit and ensure required equipment is in the kit as per 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 September 2019
Resolved
Re-install emergency lights in overnight accomodation spaces. Vsl O/O in process of renewing lights.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 19 September 2019
Resolved
Instructions for activating CO2 system missing. Provide sign /instructions for activation CO2 system for the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2019
Resolved 18 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 September 2019
Resolved
Update emergency instructions/station bill to include designated crew member as a watch patrolman.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Update log book to organize weekly, monthly, quarterly, and annual inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Provide a means to log watch patrolman rounds when watch patrolman is required to be conducting rounds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2019
Resolved
Replace plug on microwave or remove microwave. Plug is missing ground pin.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2019
Resolved 19 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2019
Resolved
Remove unauthorized floresant light in accomodation space below deck. Wiring is not marine grade and run through the deck and plugged into outlet on main deck.
Action required: 10 - Deficiency Rectified
Due 19 September 2019
Resolved 19 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2019
Resolved
Port side main deck fwd electrical outlet is not mounted properly and loose and held in place by its wiring. Properly mount electrical outlet.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2019
Resolved 19 September 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2019
Resolved
Stbd side pilothouse electrical outlet is not wired correctly. The hot leg is on wrong terminal.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2019
Resolved 19 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 September 2019
Resolved
Make repairs to damaged area of life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Create a voyage plan to be included with passenger count/list when making overnight voyages.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019
Resolved
Provide documentation/check list to include records of instruction of each crew member of their duties, responsiblities, and ability/knowledge/familiarization of the location and to utilize all emergency equipment as per 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 September 2019
Resolved
Update passenger safety orientation to include the request of passengers to don a life jacket when on a voyage of more than 24 hrs as per 46 CFR 185.506(e).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2019
Resolved
Provide documenation that smoke detectors meet UL 217 standard as per 46 CFR 181.450.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
Unknown
Issued 26 July 2016
Resolved
Conduct annual inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2016
Resolved 19 September 2019