SHEARWATER is a 1929 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1984, most recently in March 2024, along with 142 deficiencies — 2 with no resolution recorded —, 2 operational controls, 1 with no removal date recorded and 4 casualty investigations between 2003 and 2022.

Records from 1984 to 2024. Most recent: inspection, 14 March 2024.

Built
1929
Last inspected
14 March 2024
Documentation
Expired · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WDD6935
Flag
UNITED STATES
367179670
Maury page id
psix-54609

Inspections, by type

…with no type recorded11
Years with a record 35 calendar years (1984–2024)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 16.0 ft × 12.5 ft
Registered tonnagegross 36 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BOOTHBAY MARINE · EAST BOOTHBAY, ME, UNITED STATES · built 1929
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeShip
Hull configurationMonohull
Hailing portNY, NY
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Net Ton
36 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD6935MMSI 367179670 · active · compulsorily equipped · granted 21 March 2017, expires 12 April 2027
WDA4079MMSI 366805520 · cancelled · voluntarily equipped · granted 11 February 2011, cancelled 8 July 2014
WCP2021MMSI not assigned · expired · voluntarily equipped · granted 1 December 1994, cancelled 5 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

INDY 7 Passenger (Inspected) · MISLE 371649 · 23 October 2019 · activity 6841827BLUE FOX Passenger (Uninspected) · MISLE 1482935 · 23 October 2019 · activity 6841827

Inspection history · 82

14 March 2024 Administrative Inspection · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7878840
27 February 2023 Hull Examination · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655601
15 July 2022 Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7507217
15 July 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7512203
20 May 2022 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7455507
5 May 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7444743
22 June 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7233100
29 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7018917
20 February 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6911413
23 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6841101
23 October 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6841827
23 July 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6759234
17 July 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6481971
16 April 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392670
24 April 2017 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6131698
12 July 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5937577
19 May 2016 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5881049
18 May 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5885498
12 April 2016 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5852213
24 May 2012 Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4328544
8 December 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4205093
12 September 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4143035
2 August 2011 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4102873
15 July 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4082288
2 December 2010 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3903244
7 July 2009 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3526843
14 November 2008 Deficiency Check · Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3363081
5 August 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3289500
1 July 2008 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3253221
28 November 2007 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3106633
10 April 2007 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2905987
2 August 2006 MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2735339
25 October 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2522005
14 April 2005 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2333935
2 December 2004 In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2251752
10 June 2004 MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2094041
9 June 2004 Examination of Repairs · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2093560
21 July 2003 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1853129
12 July 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1847688
28 April 2003 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1781844
30 May 2002 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1637886
15 October 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1382406
31 August 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 772431
22 August 2001 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397712
19 June 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1440519
18 April 2001 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1062319
11 July 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 822675
23 May 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1468582
10 April 2000 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1472931
29 April 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1444139
1 March 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 797073
29 June 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1397025
16 January 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1426022
7 January 1998 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1120423
21 October 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 778252
9 July 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 11997
30 May 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 773230
31 May 1996 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879722
31 May 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1189614
8 January 1996 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 880207
22 September 1994 COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354943
21 November 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1249921
12 October 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1223192
3 July 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1230057
5 January 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 927141
11 September 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1204838
18 July 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1206100
24 April 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1040127
23 March 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1032181
2 February 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1032361
14 December 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 898265
10 December 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1006557
18 November 1987 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024758
15 May 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1024369
18 December 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335168
1 December 1986 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1021485
27 January 1986 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997836
18 December 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1303931
16 December 1985 Credit Drydock · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1305016
5 December 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990813
5 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 974610
29 November 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285366

Deficiency record · 142

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 March 2024 No resolution recorded
Vessels designed and built to Subchapter "T" Inspection Standards, random sampling of fastenings should begin at the 10th year of age and every 5th year thereafter in salt water service... Vessel is due for pulling fasteners provide hull drawing to determine locations. 46 CFR 176.600 NVIC 7-95: Guidance on Inspection, Repair, and Maintenance of Wooden Hulls
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 March 2024 No resolution recorded
Whenever damage to hull planking or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space. The vessel had an allision with the sea wall in July 2022, at the time the apparent damage was isolated to the dolphin striker and stem. The shock load of the rig may have caused additional damage to the deck structure, provide repair plan for the following: 1) Visible main deck warping forward, amidships, and aft 2) Separation of the vessel's stem below the bobstay's attachment point. 3) The plank ends around the transom show signs of separation. 4) Make rigging end fittings and hull attachment points available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2020 Resolved
Any repair or alteration to machinery or equipment must not be made without OCMI approval. Vessel changed from a generator to batteries and an invertor. Passenger count reduced to 29, pending approval. 46CFR176.700(a)
Action required: 705 - Other - as specified
Resolved 27 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 July 2020 Resolved
Exhaust piping shall be installed to minimize injury risk to personnel. The exhaust piping is not insulated, creating a fire/burn hazard. 46CFR182.430(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2020
Resolution: Received photos of insulation installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 July 2020 Resolved
Gauges to indicate RPM shall be installed on the vessel and visible from the operating station. The tachometer was inop. + wired to the fire alarm. 46CFR182.410(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2020
Resolution: received video of operational gauges and re-wired panel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 February 2020 Resolved
The aft quarter of the vessel was repaired in the past, the butt schedule did not follow guidance of NVIC 07-95. The vessel's hull shows evidence of working and all butt joints have loosened from transom to 10 ft forward. This area is in need reconstruction. Provide repair proposal, following guidance of NVIC 7-95. The owner request repair the aft quarter and transom in the winter up in Main where the shipwright will has access to talent and material. The request has been granted.
Action required: 705 - Other - as specified
Due 20 February 2021
Resolved 7 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2019 Resolved
PROPULSION MACHINERY SHALL BE CAPABLE OF OPERATING AT A CONSTANT MARINE LOAD WITHOUT EXCEEDING ITS DESIGN REQUIREMENTS. VESSEL EXPERIENCED AN OVERHEATING OF THE MAIN ENGINE, REQUIRING THE CREW TO SHUT THE MAIN DOWN. VESSEL PROHIBITED FROM CARRYING PASSENGERS UNTIL REPAIRS ARE MADE AND A SATISFACTORY SEA TRIAL IS PERFORMED IN THE PRESENCE OF A CG MARINE INSPECTOR. 46CFR182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2020
Resolution: MI's verified operation through sea-trials.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 23 July 2019 Resolved
Vessel has standing oil in the bilge of the engine compartment. Remove all oily water from bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
Resolution: Oily water removed from bilge.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2019 Resolved
Crew not comfortable testing the fixed fire extinguishing system. Operator must demonstrate proper operation of the fixed fire extinguishing system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
Resolution: Operator demonstrated proper operation of fixed fire extinguishing system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2019 Resolved
Identified check in the starboard lower spreader on the main mast. Tune shrouds to alleviate potential uneven pressure on spreader.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
Resolution: Operator adjusted tension on main mast shrouds.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 12 July 2016 Resolved
Vessel's fuel priming assembly is made up of non-J 1942 fuel hoses. Vessel rep stated that this is an approved system as per some website. Vessel must provide proof that installed system meets J1942 standards or replace all hoses. 46CFR182.720 (e)
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 9 August 2016
Resolution: Vessel replaced all flexible hose with annealed copper tubing.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 12 July 2016 Resolved
Vessel's COI authorizes overnight accomodations, but do not have smoke detection. In fact, it is questionable if they even meet the regulations to have overnight accomodations. Vessel must meet all regulations for overnight accomodations prior to carrying overnight passengers. 46CFR181.410/181.450
Action required: 705 - Other - as specified
Resolved 9 August 2016
Resolution: At the owner [name withheld] request, overnight accommodation authorization is to be removed from the COI.
Stability › Watertight Integrity › General
Issued 8 December 2011 Resolved
Conduct underway test PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2012
Resolution: Vessel conducted underway test during COI inspection.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 August 2011 Resolved
Replace grab line around ring buoy with dark or UV resistant line.
Due 16 August 2011
Resolved 16 August 2011
Resolution: Grabline replaced with dark line.
Engineering › Bilge Water Management System › Hose
Issued 2 August 2011 Resolved
Replace flexible hose on blige system with approved type hose, as discussed, near valve on port side.
Due 16 August 2011
Resolved 16 August 2011
Resolution: Hose replaced with approved type.
Stability › Watertight Integrity › General
Issued 2 August 2011 Resolved
Replace dog on main cabin port light in starboard side.
Due 16 August 2011
Resolved 16 August 2011
Resolution: Dog replaced on main cabin port light.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 August 2011 Resolved
Properly repair leak on intake valve on day tank.
Due 16 August 2011
Resolved 16 August 2011
Resolution: Leak repaired by tightening nut at top of valve stem handle.
Construction/Loadline › Structures › Superstructure
Issued 2 August 2011 Resolved
Patch holes in main staysail, as discussed.
Due 16 August 2011
Resolved 16 August 2011
Resolution: Vesel used strong adhesive sail tape rather than the traditional stich-on patches. Acceptable substitution; deficiency is cleared.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 August 2011 Resolved
V-weld crack, starboard side, forward handrail at base.
Due 16 August 2011
Resolved 16 August 2011
Resolution: Handrail properly welded and repaired.
Construction/Loadline › Structures › Superstructure
Issued 2 August 2011 Resolved
Replace toggle in way of gooseneck on main mast, as discussed.
Due 30 September 2011
Resolved 12 September 2011
Resolution: New toggle was machined and installed staisfactorily. Operational test also satisfactory.
Stability › Intact Stability (when using lifting gear) › General
Issued 2 December 2010 Resolved
Vessel's original stability test was conducted for bare pole. If vessel wants to operate under sail with passengers onboard, vessel must have a simplified stability test conducted in the presence of the Coast Guard including a sail profile.
Action required: 705 - Other - as specified
Due 31 March 2012
Resolved 23 April 2012
Resolution: Vessel submitted a letter to take the calculated passenger reduction. Awaiting results from incline test and letter from MSC for final stability calculations.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 July 2009 Resolved
Replace (08) Adult Type I PFDs.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 July 2009
Resolution: Received faxed receipt and letter from vessel captain attesting to 8 new PFDs being provided.
Documentation › Safety Management System › Essential Sailing Instructions Documentation
Issued 14 November 2008 Resolved
Provide a third party rigging/mast survey and submit copy of the survey to the Coast Guard. 20 JAN 2009: Owner requested and was granted an extension of this requirement until April 30, 2009.
Due 30 April 2009
Resolved 8 April 2009
Construction/Loadline › Structures › Scuttle
Issued 14 November 2008 Resolved
Provide captive chains for two deck hatches IWO the lazarette space. 20 JAN 2009: Owner requested and was granted an extension of this requirement until April 30, 2009.
Due 30 April 2009
Resolved 8 April 2009
Construction/Loadline › Hull › Transverse Frame
Issued 14 November 2008 Resolved
Make necessary repairs to rotten cross member in the lazarette space IWO the rudder post. 20 JAN 2009: Owner requested and was granted an extension of this requirement until April 30, 2009.
Due 30 April 2009
Resolved 8 April 2009
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 November 2008 Resolved
Properly mount hanging electrical box IWO the forward hatch to the lazarette on the starboard side. 20 JAN 2009: Owner requested and was granted an extension of this requirement until April 30, 2009.
Due 30 April 2009
Resolved 8 April 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 14 November 2008 Resolved
Properly mount loose light fixture in the lazarette space on the port side. 20 JAN 2009: Owner requested and was granted an extension of this requirement until April 30, 2009.
Due 30 April 2009
Resolved 8 April 2009
Construction/Loadline › Hull › Side Shell
Issued 14 November 2008 Resolved
Remove angel hair to good wood on two planks IWO the engine space, port side, side shell. 20 JAN 2009: Owner requested and was granted an extension of this requirement until April 30, 2009.
Due 30 April 2009
Resolved 8 April 2009
Construction/Loadline › Hull › Transverse Frame
Issued 14 November 2008 Resolved
Submit repair proposal for the following repairs; 1. Rotten transverse deck frame IWO aft hatch to the lazarette. 2. Rotten bulkhead in forecastle void IWO the mast. Repair proposal has been received and approved. Repairs shall be inspected by attending Coast Guard Marine Inspector when completed. 20 JAN 2009: Owner requested and was granted an extension of this requirement
Due 30 April 2009
Resolved 8 April 2009
Documentation › Certificates/Documents › FCC SSL
Issued 1 July 2008 Resolved
Provide valid FCC Safety Radio Certificate. Vessel is restricted to no more than 1000 feet from shore until valid certificate is provided.
Due 1 August 2008
Resolved 3 July 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 July 2008 Resolved
Prove proper operation of bilge high level alarms.
Due 1 August 2008
Resolved 5 August 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 July 2008 Resolved
Make proper repairs and secure all deck rail stanchions throughout the vessel. Several stanchions were found loose.
Due 1 August 2008
Resolved 5 August 2008
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 1 July 2008 Resolved
Make proper repairs to broken windows over the Master's stateroom.
Action required: 705 - Other - as specified
Due 19 August 2008
Resolved 19 August 2008
Stability › Incline Test › General
Issued 28 November 2007 Resolved
Conduct simplified stability proof test in the presence of a Marine Inspector. The vessel is restricted to operation under sail during daylight hours only until complete.
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 11 December 2007
Stability › Incline Test › General
Issued 28 November 2007 Resolved
The vessel is restricted to operation under sail during non-daylight hours on a River route only until a Simplified Stability Test is conducted in the presence of a Marine Inspector.
Action required: 705 - Other - as specified
Resolved 20 July 2008
Documentation › Certificates/Documents › FCC SSL
Issued 10 April 2007 Resolved
Vessel radio station license is type "ship recreational or voluntarily equipped" - provide type "ship compulsory" onboard vessel.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 April 2007 Resolved
Post lifejacket donning placard for each type lifejacket onboard vessel.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2007 Resolved
Properly label lifejacket stowage areas.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 April 2007 Resolved
Properly secure waterlight for ring buoy.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Stability › Unintentional Flooding › General
Issued 10 April 2007 Resolved
Install dead light covers onboard vessel.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 April 2007 Resolved
Demonstrate proper operation of radar to satisfaction of attending USCG MI.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 April 2007 Resolved
Install emergency fuel shutoff on 10gal tank in engine space and properly label.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Engineering › Fuel Oil Service System › Hose
Issued 10 April 2007 Resolved
Replace fuel lines on generator with approved fuel hose.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Engineering › Fuel Oil Service System › Filter
Issued 10 April 2007 Resolved
Replace bowl on racor fuel filter.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 9 May 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 August 2006 Resolved
Provide current US Coast Pilot IAW 46 CFR 184.420
Due 9 August 2006
Resolved 30 August 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 2 August 2006 Resolved
Provide retro tape on (02) chlild lifejackets IAW 46 CFR 185.604.
Due 9 August 2006
Resolved 30 August 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 2 August 2006 Resolved
Replace 01 child lifejacket IAW 46 CFR 180.71. Until def is cleared max # of children = 5.
Due 9 August 2006
Resolved 30 August 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 August 2006 Resolved
Provide current Light List.
Due 9 August 2006
Resolved 30 August 2006
Lifesaving › Lifebuoys › Serviceable
Issued 2 August 2006 Resolved
Replace ring lifebuoy w/ new IAW 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2006
Resolution: Viewed new ring life buoy.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 August 2006 Resolved
Place wire splice for inverter in an enclosure.
Due 9 August 2006
Resolved 30 August 2006
Construction/Loadline › Penetrations › Bottom Plug
Issued 2 August 2006 Resolved
Overboard valve located starboard side forward (forecastly) is leaking water. Make permanent repairs to stop water ingress, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2006
Resolution: Seacock was patched from outside the vsl, then taken apart and repacked with grease. Will include a special note to replace at next DD and pay attention to at next Annual.
Accommodation/Occupational Safety › Potable Water System › General
Issued 2 August 2006 Resolved
Gray water tank is full and leaking water into bilge. Empty tank and properly plumb grey water tank to prevent water from entering bilge.
Due 9 August 2006
Resolved 30 August 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 2 August 2006 Resolved
Remove oily wastes from E/R bilge.
Due 9 August 2006
Resolved 30 August 2006
Documentation › Logs/Records › Drug Test Records
Issued 2 August 2006 Resolved
Provide proof of Drug + Alcohol program enrollment.
Due 9 August 2006
Resolved 2 August 2006
Resolution: Viewed current certificate of enrollment.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 August 2006 Resolved
Present log book for examination by USCG Marine Inspector.
Due 9 August 2006
Resolved 30 August 2006
Engineering › Bilge Water Management System › Strainer
Issued 13 April 2005 Resolved
Add strainer to bilge suction line in salon.
Condition: Unknown
Due 20 April 2005
Resolved 24 May 2005
Resolution: Replaced Same.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 April 2005 Resolved
Either hydrostatically test fixed CO2 cylinder or provide documentation of previous test.
Due 30 May 2005
Resolved 24 May 2005
Resolution: Hydrostatically Tested same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 April 2005 Resolved
Terminate electrical wires (overhead fan and 12 volt cooler) in galley.
Due 20 April 2005
Resolved 24 May 2005
Resolution: Terminated same.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 2 December 2004 Resolved
Refill or replace B-II portable fire extinguishers located in the port cabinet below deck as required by 46 CFR 181.30-1.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2004
Resolved 18 February 2005
Resolution: Rcvd fax stating 10lb Dry Chemical Fire Extinguisher recharged.
Electrical › Lighting (service) › Outlet Box
Issued 2 December 2004 Resolved
Remove plastic covers on incadesent lights located below deck due to fire hazard. Replace with a cover acceptable to the attending CG marine inspector.
Due 3 January 2005
Resolved 18 February 2005
Resolution: Rcvd fax from [name withheld] stating all plastic covers removed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 June 2004 Resolved
Post COI so all pages are visible to passengers.
Due 17 June 2004
Resolved 16 June 2004
Resolution: Received verbal statement from vessel operator that all pages were properly posted.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 June 2004 Resolved
Provide current Coast Pilot. LEGACY COMPONENT DESC: US Coast Pilot
Due 17 June 2004
Resolved 16 June 2004
Resolution: Received fax copy of the receipt for new Coast Pilot.
Navigation › Piloting/Steering › Marine Charts
Issued 10 June 2004 Resolved
Provide current chart for area of operation.
Due 17 June 2004
Resolved 16 June 2004
Resolution: Received fax copy of receipt.
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 June 2004 Resolved
Provide additional 29 adult lifejackets for a total of 52. Vsl is restricted to carring 23 adult passengers until corrected. LEGACY COMPONENT DESC: Quantity
Due 10 June 2004
Resolved 10 June 2004
Resolution: Received a faxed copy of a receipt which showed proof of purchase for 29 Type 1 Adult lifejackets. Instructed owners to properly label all lifejackets with vsl name.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 June 2004 Resolved
Provide CG approved First Aid Kit or on with equivalent contents.
Due 17 June 2004
Resolved 10 June 2004
Resolution: Provided equivalent contents prior to departure.
Operations/Management › Drug and Alcohol Testing
Issued 10 June 2004 Resolved
Provide proof on enrollment in drug and alcohol program in accordance with 46 CFR part 16. LEGACY COMPONENT DESC: Employee Coverage
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2004
Resolved 10 June 2004
Resolution: Received faxed copy of American Maritime Safety, Inc (Consortium) stating Shearwater holding''s employees enrolled in drug and alcohol testing program.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 April 2003 Resolved
Address the fuel leak at the emergency fuel shut off
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2003
Resolved 9 May 2003
Engineering
Issued 28 April 2003 Resolved
To make sure that the Bilge, low oil and hi water temps are working
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 9 May 2003
Fire Fighting › Structural Fire Protection - General
Issued 28 April 2003 Resolved
To provide servicing of the fixed fire system
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2003
Resolved 9 May 2003
Resolution: Paper work is on file on board vessel
Documentation › Certificates/Documents
Issued 28 April 2003 Resolved
Provide operator's permit for marine radio
Due 9 May 2003
Resolved 9 May 2003
Resolution: Copy of application is on board
Documentation › Certificates/Documents
Issued 28 April 2003 Resolved
Provide a current copy of the Captains license
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2003
Resolved 9 May 2003
Navigation › Piloting/Steering › Marine Charts
Issued 28 April 2003 Resolved
Provide an updated chart of NY Harbor
Due 9 May 2003
Resolved 9 May 2003
Electrical › Electrical Distribution System (service)
Issued 28 April 2003 Resolved
Secure/ bracket wires IWO Salon. Passage way, and Eng rm LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 22 May 2003
Resolved 22 May 2003
Electrical › Lighting (service)
Issued 28 April 2003 Resolved
Remove and/or properly secure the light in the galley
Due 22 May 2003
Resolved 22 May 2003
Engineering › Fuel Oil Service System
Issued 28 April 2003 Resolved
Place a bracket on the fuel line in way of area behind nav. station LEGACY COMPONENT DESC: Piping
Due 22 May 2003
Resolved 28 April 2003
Electrical › Electrical Distribution System (service)
Issued 28 April 2003 Resolved
Properly secure the wires in way of the fuel line behind the nav. station LEGACY COMPONENT DESC: Wiring
Due 22 May 2003
Resolved 22 May 2003
Engineering › Fuel Oil Service System
Issued 28 April 2003 Resolved
Double clamp the fuel line behind the Nav station LEGACY COMPONENT DESC: Piping
Due 22 May 2003
Resolved 22 May 2003
Engineering › Fuel Oil Service System
Issued 28 April 2003 Resolved
Remove the old suction hose in way of passage way bilges LEGACY COMPONENT DESC: Hose
Due 22 May 2003
Resolved 28 April 2003
Electrical › Lighting (service)
Issued 28 April 2003 Resolved
Remove or make operational the light in the engine room LEGACY COMPONENT DESC: Lighting Fixture
Due 22 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service)
Issued 28 April 2003 Resolved
Bracket wires over exhaust manifold
Due 22 May 2003
Resolved 22 May 2003
Electrical › Electric Generation Source (service)
Issued 28 April 2003 Resolved
secure the wires from or to the alternator LEGACY COMPONENT DESC: Generator
Due 22 May 2003
Resolved 22 May 2003
Electrical › Electric Supply System (service)
Issued 28 April 2003 Resolved
Clean the terminals to the batteries LEGACY COMPONENT DESC: Cable
Due 22 May 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service)
Issued 28 April 2003 Resolved
Address the dead ended wires to the generator and also to the batteries LEGACY COMPONENT DESC: Wiring
Due 22 May 2003
Resolved 22 May 2003
Engineering › Sea-water System (primary cooling)
Issued 28 April 2003 Resolved
Double clamp the wet exhaust cooling line as needed LEGACY COMPONENT DESC: Piping
Due 22 May 2003
Resolved 28 April 2003
Engineering › Freshwater System (cylinder head cooling)
Issued 28 April 2003 Resolved
Replace coolant hose on top of the MDE LEGACY COMPONENT DESC: Hose
Due 22 May 2003
Resolved 22 May 2003
Lifesaving › Lifebuoys
Issued 28 April 2003 Resolved
Add corrosion resistant clip to the float light and retro tape to the life ring
Due 22 May 2003
Resolved 28 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 April 2003 Resolved
Update first aid kit, eyewash, aspirin.
Due 22 May 2003
Resolved 22 May 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 April 2003 Resolved
Secure bracket to fire ext IWO pilot station.
Due 22 May 2003
Resolved 22 May 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2003 Resolved
Paint nav light matte flat black
Due 22 May 2003
Resolved 22 May 2003
Engineering › Lubricating Oil Service System › Filter
Issued 28 April 2003 Resolved
Address leak by oil filter cannister
Due 22 May 2003
Resolved 22 May 2003
Fire Fighting
Issued 30 May 2002 Resolved
Prove proper operation according to Old Sub T-L, fire pump off bilge pump
Due 31 May 2002
Resolved 31 May 2002
Resolution: Proper operation proved this date
Operations/Management
Issued 30 May 2002 Resolved
Prove enrollment DAPI program
Due 31 May 2002
Resolved 31 May 2002
Resolution: DAPI enrollment proven
Navigation
Issued 30 May 2002 Resolved
Install approved NAV lights on PT and STBD side main deck.
Due 31 May 2002
Resolved 31 May 2002
Resolution: Approved lights installed
Fire Fighting
Issued 30 May 2002 Resolved
Witness CO2 test, prepare for CG inspection of fixed firefighting system
Due 31 May 2002
Resolved 31 May 2002
Resolution: Test so witnessed
Lifesaving
Issued 30 May 2002 Resolved
Properly rig lifering and light
Due 31 May 2002
Resolved 31 May 2002
Resolution: Lifering and light properly rigged
Lifesaving
Issued 30 May 2002 Resolved
Replace retro tape on 25 lifejackets
Due 31 May 2002
Resolved 31 May 2002
Resolution: Tape replaced on aforementioned lifejackets
Lifesaving
Issued 30 May 2002 Resolved
Provide servicing report for inflatable liferaft prior to next int'l voyage.
Due 25 October 2002
Resolved 25 October 2002
Resolution: Vessel owner dropped International route off of COI, thereby negating need for an inflatable liferaft, for this vessel. 835 now cleared, see narrative, dated 25OCT02.
Lifesaving
Issued 30 May 2002 Resolved
Post lifejacket donning placard
Due 31 May 2002
Resolved 31 May 2002
Resolution: Placard now posted
Fire Fighting
Issued 30 May 2002 Resolved
Provide fire axe in or near primary operating station
Due 31 May 2002
Resolved 31 May 2002
Resolution: Axe provided in approved area
Engineering
Issued 30 May 2002 Resolved
Prove proper operation main propulsion and at this time conduct MOB drill
Due 31 May 2002
Resolved 31 May 2002
Resolution: Main propulsion tested underway in Hudson River, and at this time MOB drill was conducted satisfactorily, with the MOB 160 LB dummy.
Navigation
Issued 30 May 2002 Resolved
Provide updated NAV pubs
Due 31 May 2002
Resolved 31 May 2002
Resolution: NAV pubs updated and so provided
Navigation
Issued 30 May 2002 Resolved
Provide approved Bell
Due 15 June 2002
Resolved 13 June 2002
Resolution: Approved Bell provided
Communications
Issued 30 May 2002 Resolved
Provide updated FCC Radiotelephony certificate
Due 15 June 2002
Resolved 13 June 2002
Resolution: FCC cert updated
Electrical
Issued 15 October 2001 Resolved
Remove all solid core wire and replace with appropriate wire stbd side engine room and at foremast (engine room wire removed).
Condition: Unknown
Due 17 November 2001
Resolved 13 June 2002
Resolution: Removed and replaced
Electrical
Issued 22 August 2001 Resolved
COMPLETE AS BUILT VERIFICATION FOR THE NEW INSTALLATION OF 12VDC EMERGENCY LIGHTING SYSTEM IAW NYCMI APPROVED PLANS AND NYCMI LETTER PR-010093.
Condition: Unknown
Due 31 October 2001
Resolved 13 June 2002
Resolution: As built verified at COI inspection
Documentation
Issued 19 June 2001 Resolved
Provide vessel voyage plan IAW 46CFR185.503
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Accommodation/Occupational Safety
Issued 19 June 2001 Resolved
Provide general alarm IAW 46CFR183.550
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 19 June 2001 Resolved
Repair/replace hi water bilge alarm in fwd compartment.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Lifesaving
Issued 19 June 2001 Resolved
Conduct Man overboard drills to the satisfaction of attending Marine Inspector.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Lifesaving
Issued 19 June 2001 Resolved
Replace hydrostatic release for EPIRB
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Navigation
Issued 19 June 2001 Resolved
Provide current navigation publications. REEDS almanac is an acceptable alternative.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Construction/Loadline
Issued 19 June 2001 Resolved
Double hose clamp all bilge piping hoses.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Lifesaving
Issued 19 June 2001 Resolved
Mark all lifejackets with proper name and label storage area.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Fire Fighting
Issued 19 June 2001 Resolved
Provide current service report of E/R CO2 system.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Electrical
Issued 19 June 2001 Resolved
Provide emergency lighting for below deck IAW 46CFR183.550
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Lifesaving
Issued 23 May 2000 Resolved
On the Ocean or Coastwise or Limited Coastwise routes, with more than six passengers onboard - the vessel is restricted to no more than three miles from land until the battery for the Emergency Position Indicating Radio beacon has been replaced.
Condition: Unknown
Due 23 July 2000
Resolved 24 May 2000
Lifesaving
Issued 29 April 1999 Resolved
Provide retro-reflective tape as indicated for the bouyant apparatus and the life ring buoy.
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Navigation
Issued 29 April 1999 Resolved
Provide matte black backgrounds for the port and stbd running lights.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Engineering
Issued 29 April 1999 Resolved
Provide 30x30 mesh flame screen for the aft fuel tank vent.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 29 April 1999 Resolved
On the primary bilge system, renew the flexible lines with hoses suitable for the service.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Lifesaving
Issued 16 January 1998 Resolved
VESSEL RESTRICTED TO NMT 3 MILES FROM THE NEAREST LAND UNTIL PRIMARY LIFESAVING EQUIPMENT HAS BEEN INSTALLED IF VESSEL CARRIES MORE THAN 16 PERSONS ONBOARD.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Lifesaving
Issued 30 May 1997 Resolved
Conduct underway drills prior to carrying passengers for hire. Drills to be conducted in the presence of a Coast Guard Marine Inspector.
Condition: Unknown
Due 6 June 1997
Resolved 9 June 1997
Documentation
Issued 31 May 1996 Resolved
Provide copy of FCC safety Certificate. _x001C_ _x001C_ _x001C_ Commercial exam completed and documentation submitted to FCC.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Navigation
Issued 31 May 1996 Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Navigation
Issued 31 May 1996 Resolved
Document crew training and drills.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 31 May 1996 Resolved
Provide clip for ring buoy waterlight.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Documentation
Issued 31 May 1996 Resolved
Provide documentation of drug testing program in compliance with CG regs.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Fire Fighting
Issued 31 May 1996 Resolved
Provide 2 B-II fire extinguishers. _x001C_ _x001C_ _x001C_ B-IIs on order. Additional B-Is onboard.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Lifesaving
Issued 31 May 1996 Resolved
Provide 1 orange ring buoy.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 31 May 1996 Resolved
Provide life jacket placard.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 31 May 1996 Resolved
Provide 2 waterlights for life jackets.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 31 May 1996 Resolved
Provide 1 adult life preserver. Vessel restricted to no more than 51 adultsuntil additional one installed.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Lifesaving
Issued 31 May 1996 Resolved
Properly install 12ft long pendants on buoyant apparatus.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Accommodation/Occupational Safety
Issued 24 April 1989 Resolved
PROVIDE AN APPROVED MARINE SANITATION DEVICE TO THE INSTALLED TOILET IN WAYOF FORWARD BERTHING.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Lifesaving
Issued 14 December 1988 Resolved
RENEW GRAB LINES ON BOUYANT APPARATUS.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Lifesaving
Issued 14 December 1988 Resolved
PROVIDE AN 8 MAN INFLATABLE LIFERAFT.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Navigation
Issued 14 December 1988 Resolved
RENEW E.P.I.R.B. BATTERY.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Documentation
Issued 14 December 1988 Resolved
PROVIDE CURRENT COMMUNICATIOS ACT RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Documentation
Issued 18 November 1987 Resolved
RENEW EXPIRED FCC STATION LICENSE.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Lifesaving
Issued 18 November 1987 Resolved
REPLACE WASTED WEAK LINK FOR BUOYANT APPARATUS.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Fire Fighting
Issued 16 December 1985 Resolved
SERVICE 35 LBS. CO2 BOTTLE IN ENGINEROOM
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Navigation
Issued 5 December 1984 Resolved
OBTAIN FCC SAFETY R/T CERTIFICATE OR A RENEWAL/EXTENSION LTR FOR SAME.
Condition: Unknown
Due 5 December 1984
Resolved 5 December 1984

Casualty record · 4

12 July 2003Routine · role: Involved in a Marine Casualty · activity 1847688
18 May 2016Routine · role: Involved in a Marine Casualty · activity 5885498
23 October 2019Routine · role: Involved in a Marine Casualty · activity 6841827
15 July 2022Routine · role: Involved in a Marine Casualty · activity 7512203
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.