MAURY USCG vessel records Sign in
← All vessels

GSF MAIN PASS IV

GSF MAIN PASS IV is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 89 inspections since 1982, most recently in January 2007, along with 153 deficiencies and 3 casualty investigations between 2002 and 2003.

Records from 1982 to 2007. Most recent: inspection, 22 January 2007.

Built
1982
Last inspected
22 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8751502 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
VANUATU
—
Maury page id
psix-54626

Inspections, by type

…with no type recorded23
Years with a record 26 calendar years (1982–2007)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4976 - Convention (Subpart B), Gross Ton
4580 - Regulatory (Subpart C or D), Gross Ton
1244 - Convention (Subpart B), Net Ton
4580 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KCHMMMSI not assigned · expired · compulsorily equipped · granted 5 September 1997, cancelled 5 January 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA RAMBLER Passenger (Inspected) · MISLE 48204 · 5 November 2002 · activity 1705956BOB ROUSE Offshore Supply Vessel · MISLE 49331 · 22 October 2002 · activity 1695629ML GROVE Offshore Supply Vessel · MISLE 455468 · 1 May 2002 · activity 1616361

Inspection history · 89

22 January 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2859967
2 August 2006 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2734806
15 September 2005 COC-MODU Annual
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2485298
20 July 2004 COC-MODU Renew
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2139043
18 February 2004 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2008835
21 August 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1897606
20 March 2003 Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1745825
18 March 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1767530
5 November 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1705956
22 October 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1695629
4 September 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670804
1 May 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1616361
1 April 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1599765
11 March 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1492896
18 January 2002 Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1479359
25 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073155
30 April 2001 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382357
8 February 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1395658
21 January 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429282
25 October 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1129493
1 July 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082351
9 March 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426180
25 January 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1122744
17 December 1998 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 807791
14 December 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455653
18 November 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806419
6 October 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 801165
21 May 1998 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1399005
5 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1119271
23 January 1998 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 798957
15 December 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427456
23 July 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 141978
18 January 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 126951
8 January 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1096583
18 December 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390408
16 October 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 850296
20 September 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371543
12 July 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1095338
16 May 1996 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402251
4 April 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1078452
20 December 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357423
11 April 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 845182
25 January 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1137644
9 December 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446152
21 August 1994 Damage Survey · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454125
10 June 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1016521
11 March 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444826
10 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163646
27 December 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455119
15 June 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 842855
6 June 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 136225
15 January 1993 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1133821
10 January 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264284
19 December 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 945979
12 December 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1258188
7 November 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 932590
3 July 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937234
11 March 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916904
11 February 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922804
10 December 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237376
5 November 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220854
26 October 1990 Deficiency Check · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904703
12 September 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929461
22 August 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911089
17 July 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246254
2 June 1990 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 924943
13 May 1990 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 908927
8 January 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229090
31 October 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1221523
25 April 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340589
27 March 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1350262
21 December 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344880
22 November 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207649
12 August 1988 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346424
28 July 1988 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341968
12 July 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 898158
12 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338612
2 November 1987 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1330860
24 November 1986 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1019595
17 April 1986 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1307146
14 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 983892
28 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1286512
9 March 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1290254
12 December 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1283859
9 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281695
11 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972915
25 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271546
24 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975503
22 December 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967326

Deficiency record · 153

Construction/Loadline › Hull › Bottom Plating
Issued 21 July 2004 Resolved
Complete phase II of SEILOD exam proposal at next rig move.
Due 22 August 2004
Resolved 10 October 2004
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 July 2004 Resolved
Prove proper operation of purge alarm for driller consule on drill floor.
Due 22 August 2004
Resolved 22 August 2004
Engineering › Bilge Water Management System › Not Operational
Issued 21 July 2004 Resolved
Prove proper operation of bilge system.
Due 22 August 2004
Resolved 22 August 2004
Construction/Loadline › Hull › Bottom Plating
Issued 8 March 2004 Resolved
Complete Phase II of SEILOD exam proposal at next rig move.
Due 8 April 2004
Resolved 21 July 2004
Construction/Loadline › Hull
Issued 18 February 2004 Resolved
Crop & renew wasted main deck area above 7p. Provide gauging report for surronding area not cropped & renewed.
Due 8 April 2004
Resolved 14 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 4 March 2003 Resolved
Install safety netting or other barrier in unprotected helideck perimeter IWO starboard ladder.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 4 March 2003 Resolved
Mark both accesses to helicopter landing areas with "Beware of Tail Rotor" IAW 46 CFR 108.653(c)&(d).
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Lifesaving › Launching Appliances › Falls
Issued 4 March 2003 Resolved
As lifeboat falls were not end-for-ended at 3-year interval, ensure that they are replaced at 4 year interval (September 2003)
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 16 April 2003
Fire Fighting › Miscellaneous Items
Issued 4 March 2003 Resolved
Ensure that all fire extinguisher hydros & servicing (expired/due/outstanding) is completed iaw Gulf Wide Safety report of 13DEC02.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Fire Fighting › Nozzles
Issued 4 March 2003 Resolved
Repair broken firefighting applicator brackets on helideck. Free-up seized applicator nozzles.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Fire Fighting › Structural - A Class Divisions
Issued 4 March 2003 Resolved
Replace missing door closer & latch (knob) on pantry door (A-class fire boundary).
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 March 2003 Resolved
Renew starboard obstruction light pedestal.
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 16 April 2003
Lifesaving › Embarkation Appliances/Stations
Issued 4 March 2003 Resolved
Prove operation of port-side lifeboat embarkation light.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 4 March 2003 Resolved
Replace smashed sprinkler tubing on port lifeboat.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Lifesaving › Lifeboat › Canopy
Issued 4 March 2003 Resolved
Repair cracked and separated canopy reinforcement on port lifeboat.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Lifesaving › Launching Appliances › Davit
Issued 4 March 2003 Resolved
Renew wasted lifeboat davit stops, port & starboard lifeboats.
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 16 April 2003
Communications › Alarms/Indicators › General Alarm
Issued 4 March 2003 Resolved
Remove volume controls from PA/GA speakers.
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 16 April 2003
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 4 March 2003 Resolved
Install fitted turbo exhaust lagging on all diesel engines including emergency generator.
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 16 April 2003
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 4 March 2003 Resolved
Replace three (3) lifejacket chem lights.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Lifesaving › Inflatable Liferafts
Issued 4 March 2003 Resolved
Install davit launched liferafts as specified by the manufacturer instructions (hydrostatic release, etc.)
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Control Valves
Issued 4 March 2003 Resolved
Fixed fire extinguishing system for mud pit & engineroom need permanent labels for control valves & discharge delay.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 4 March 2003 Resolved
Replace or repair main circuitbreaker & engine starter on #2 generator.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Lifesaving › Buoyant Apparatus
Issued 4 March 2003 Resolved
Install waterlight bracket for lifering on port control weatherdeck.
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 16 April 2003
Electrical › Electric Supply System (service)
Issued 18 January 2002 Resolved
Replace battery boxes for fog horn, obstruction light, and general alarm. Both rusted and holed. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 16 April 2002
Resolved 1 April 2002
Resolution: Received faxed documentation from the rig manager that the requirement has been satisfied.
Lifesaving › Lifeboat
Issued 18 January 2002 Resolved
Make repairs to lifeboat sprinkler system starboard side. Replace inset pipe and replace missing sprinkler head. LEGACY COMPONENT DESC: Fire Protection (water spray system)
Condition: Damaged By Earlier Event
Due 16 April 2002
Resolved 18 March 2002
Resolution: Received faxed documentation from the rig manager that the requirement has been satisfied.
Lifesaving › Launching Appliances
Issued 18 January 2002 Resolved
Provide 3rd party test report for lifeboat fall renewal or conduct lifeboat weight test in presence of CG Marine Inspector. LEGACY COMPONENT DESC: Falls
Due 18 February 2002
Resolved 31 January 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 18 January 2002 Resolved
Provide documentation for CG approval of FRP grating in area of flight deck. LEGACY COMPONENT DESC: Open Deck Space
Condition: Unknown
Due 18 February 2002
Resolved 31 January 2002
Construction/Loadline › Structures
Issued 18 January 2002 Resolved
Replace to steel fiberglass grating in mud pit. LEGACY COMPONENT DESC: Deck Plating
Condition: Damaged By Earlier Event
Due 18 February 2002
Resolved 31 January 2002
Construction/Loadline
Issued 30 April 2001 Resolved
COMPLETE PHASE II OF SIELOD AT NEXT RIG MOVE. PROVIDE NOTIFICATION AS REQUIRED FOR SEILOD IN 46 CFR 107.267 PRIOR TO DIVING OPERATIONS. CURRENT LOCATION IS MAIN PASS 223.
Condition: Unknown
Due 30 September 2001
Resolved 11 February 2002
Resolution: RECEIVED PAPERWORK WHILE ON RIG ATTESTING TO COMPLETION OF PHASE II WITH ABS IN ATTENDANCE.
Deck/Cargo
Issued 8 February 2001 Resolved
Provide proof of annual crane exam. A faxed copy of completed ABS survey with report shall be suitable for completion of this requirement.
Condition: Unknown
Due 27 April 2001
Resolved 27 April 2001
Lifesaving
Issued 8 February 2001 Resolved
Complete the required periodical maintenance/testing of all machinery and equipment in accordance with 46 CFR 109.201, 109.211 and 109.301 (lifesaving equipment); develop appropriate log to record same.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 8 February 2001 Resolved
Prove proper operation of boh electric bilge pumps. Pumps shall provide suction from all sumps to respective sides and in the pump manifold cross tie configuration.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 8 February 2001 Resolved
Provide OIM statement attesting to the launching, releas and operation of both capsules at first calm weather day; include operation of sprinkler system.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Lifesaving
Issued 21 January 2000 Resolved
HAVE FLANGE REPAIRED ON #1 LIFEBOAT. REPAIRS TO BE CONDUCTED BY AUTHORIZED REPAIR COMPANY.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Construction/Loadline
Issued 21 January 2000 Resolved
CROP AND RENEW OVERHEAD STIFFENERS IN MUD PITS WHERE WASTED. REPAIR WASTED SECTION OF MUD PIT EXHAUST TRUNK CASING.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Lifesaving
Issued 21 January 2000 Resolved
CONDUCT 1.1 RELEASE GEAR OPERATIONAL TEST ON BOTH LIFEBOATS.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Construction/Loadline
Issued 9 March 1999 Resolved
SUBMIT REPIAR PROPOSALS & WELDER QUALS FOR ON GOING STEEL WORK CALLED OUT BY GLOBAL.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Construction/Loadline
Issued 9 March 1999 Resolved
CONDUCT NDE OF LEG TO CAN CONNECTIONS & SPUD CAN SWIM BY. SUBMIT COPY OF DIVE REPORT & VIDEO TO THE [name withheld].
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 9 March 1999 Resolved
COMPLETE REPAIRS AS PER REPAIR PROPOSAL SUBMITTED TO [name withheld] TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 9 March 1999 Resolved
CROP & RENEW PRELOAD HATCH COVER GASKET RETAINING LIPS AS NECESSARY.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 9 March 1999 Resolved
SUBMIT REPAIR PROPOSAL & PROVIDE WELDERS QUALS FOR STEEL WORK AS LISTED ON ENCLOSURE (1), ON FILE AT MORMS.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Lifesaving
Issued 14 December 1998 Resolved
PROVIDE NEW LIFE RING BUOY FOR FORWARD STBD SIDE.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Fire Fighting
Issued 14 December 1998 Resolved
PROVIDE NOZZLE CHAIN FOR FIRE STATION #26.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Fire Fighting
Issued 14 December 1998 Resolved
LABEL VENT SHUTDOWN PROCEDURES FOR PAINT LOCKER, INCLUDE IN FIXED CO2 DEPLOYMENT PROCEDURES.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Lifesaving
Issued 14 December 1998 Resolved
PROVIDE RECESSED TIE DOWNS FOR HELO DECK
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Fire Fighting
Issued 14 December 1998 Resolved
PROVIDE BATTERIES FOR SMOKE DETECTORS FOR S/R 3-6 AND 1-4
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Fire Fighting
Issued 14 December 1998 Resolved
REMOVE OUTDATED SCBA BOTTLE FROM SERVICE IN SACK ROOM.
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Lifesaving
Issued 14 December 1998 Resolved
REMOVE 21 BAD PFD'S FROM SERVICE
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Fire Fighting
Issued 14 December 1998 Resolved
RENEW AS ORIGINAL WASTED ELBOW PIPING AT FIRE STATION #26 ON HELO DECK.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Lifesaving
Issued 14 December 1998 Resolved
PROVIDE 2 BUOYANT ROCKETS FOR LINE THROWING ROCKETS.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Navigation
Issued 14 December 1998 Resolved
PROVE PROPER OPERATION OF FOG HORN
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Lifesaving
Issued 14 December 1998 Resolved
REMOVE TWO UNSERVICABLE WORK VESTS FROM SERVICE
Condition: Unknown
Due 5 January 1999
Resolved 5 January 1999
Documentation
Issued 15 December 1997 Resolved
PROVIDE FULL-TERM LOADLINE CERTIFICATE FROM ABS.
Condition: Unknown
Due 27 February 1998
Resolved 25 March 1998
Documentation
Issued 15 December 1997 Resolved
CONDUCT QUADRENNIAL PROOF TESTS ON ALL CRANES.
Condition: Unknown
Due 15 December 1997
Resolved 15 December 1997
Lifesaving
Issued 18 December 1996 Resolved
RECHARGE LOW BOTTLE FOR BREATHING AIR SYSTEM IN PORT LIFEBOAT.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Lifesaving
Issued 18 December 1996 Resolved
AFFIX RETRO-REFLECTIVE TAPE TO ALL RING BUOUS ONBOARD MODU.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Electrical
Issued 18 December 1996 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR AUTO START AND OPERATION OF EMERGENCY GENERATOR.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Construction/Loadline
Issued 20 September 1996 Resolved
SUPPLY COPY OF FINAL VIDEO AND ABS REPORT OF UNDERWATER SURVEY FROM 20SEP96TO OCMI.
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Construction/Loadline
Issued 16 May 1996 Resolved
COMPLETE UNDERWATER PORTION OF SPECIAL EXAM IN LIEU OF DRYDOCKING IN ACCORDANCE WITH PROPOSAL DATED 08MAY96.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Construction/Loadline
Issued 16 May 1996 Resolved
MAKE MASTER MUD DUMP VALVE AVAILABLE FOR INSPECTION BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Fire Fighting
Issued 20 December 1995 Resolved
Submit proposal to [name withheld] for determing extent of wastage of firemain due to corrosion; crop and renew known wasted piping (all exteriorfire stationss and emergency fire pump discharge piping where unauthorized repairs (doublers) have been made.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Documentation
Issued 20 December 1995 Resolved
Submit Fire and Safety (Lifesaving) Plan (dwg) to [name withheld] for review and approval or submit plan previously approved by Coast Guard. (No approved plans onboard).
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Fire Fighting
Issued 20 December 1995 Resolved
Complete all outstanding deficiencies noted on fire extinguishing servicingreport by Total Safety Concepts dtd 08DEC95. Submit report by same companyaddressing each issued.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Lifesaving
Issued 20 December 1995 Resolved
Repair/replace following on #1 lifeboat: 1) renew first aid kit, 2) repairinoperative interior lighting.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Lifesaving
Issued 20 December 1995 Resolved
Repair/replace following on #2 lifeboat: 1) expired first aid kit, 2) recharge one of four breathing air cylinders, 3) repair inoperative interior lighting.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Electrical
Issued 20 December 1995 Resolved
Repair diesel engine alarm panel in SCR room.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Engineering
Issued 20 December 1995 Resolved
Repair lube oil pump on #5 generator and conduct required tests on same engine: overspeed, lube oil shutdown, reverse power relay.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Engineering
Issued 20 December 1995 Resolved
Repair low lube foil pressure shutdown on #1 generator diesel prime mover.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Engineering
Issued 20 December 1995 Resolved
Repair hotstart on emergency generator diesel prime mover.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Lifesaving
Issued 9 December 1994 Resolved
PROVIDE DRIP PANS FOR NOZZLES ON THREE (3) CRANE REFUELING HOSES.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Lifesaving
Issued 9 December 1994 Resolved
REPLACE FALLS (CABLES) ON BOTH DAVIT LAUNCHED LIFERAFT DAVITS.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Fire Fighting
Issued 9 December 1994 Resolved
ENSURE ALL FIREHOSE NOZZLES HAVE GASKETS FOR TIPS, CHAINS AND LATCHES/TIPS OPERATE PROPERLY.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Lifesaving
Issued 9 December 1994 Resolved
RENEW HANDLES ON BOTH DAVIT LAUNCHED LIFERAFT BRAKE RELEASES.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Fire Fighting
Issued 9 December 1994 Resolved
LABEL ACTUATING STATIONS FOR GALLEY DRY CHEMICAL SYSTEMS AT REMOTE STATIONSON OUTSIDE FORWARD STARBOARD QUARTERS BULKHEAD. CLEAN INSTRUCTION PLACARD FOR CO2 SYSTEM FOR PAINT LOCKER.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Accommodation/Occupational Safety
Issued 9 December 1994 Resolved
REPLACE VENTILATION FAILURE ALARM SWITCHES IN MUDPIT ROOM.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Construction/Loadline
Issued 11 March 1994 Resolved
COMPLETE LOWER HULL INSPECTION AS PER GLOBAL MARINE DRILLING CO. PROPOSAL DATED 18FEB94.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Navigation
Issued 27 December 1993 Resolved
PROVIDE NEW LENS FOR STERN LIGHT.
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 27 December 1993 Resolved
REPAIR AND MAKE GAS TIGHT BOTH DOORS TO MUD PIT ROOM.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Accommodation/Occupational Safety
Issued 27 December 1993 Resolved
PROPERLY INSTALL RELIEF VALVE AND MAKE AVAILABLE FOR INTERNAL EXAM FROM BOTH ENDS AIR RECEIVER BELOW DRILL FLOOR (OR HYDRO).
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 27 December 1993 Resolved
PROVE PROPER OPERATION OF GENERATOR SET NO. 4 REMOTE SHUTDOWN.
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 27 December 1993 Resolved
PROVIDE BATTERY (TEMPORARY) EMERGENCY LIGHT STBD. SIDE SWITCH ROOM.
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Lifesaving
Issued 27 December 1993 Resolved
REPAIR REAR WINDOW AND LIFELINE ON LIFEBOAT NO. 2.
Condition: Unknown
Due 9 February 1994
Resolved 9 February 1994
Electrical
Issued 27 December 1993 Resolved
REMOVE NON-EXPLOSION PROOF AIR CONDITIONER/HEATER UNIT FROM ROOF OF DRILL FLOOR.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Fire Fighting
Issued 19 December 1991 Resolved
PROVIDE A CHECK VALVE FOR STBD INTERNATIONAL SHORE CONNECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 January 1992
Resolved 10 January 1992
Electrical
Issued 19 December 1991 Resolved
RENEW FOUR BROKEN POWER COILS FOR THE MOTORS OF EACH SHALE SHAKER (ONE ON EACH SHAKER)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 January 1992
Resolved 10 January 1992
Lifesaving
Issued 19 December 1991 Resolved
PROVIDE CALIBRATION GAS FOR BOTH OXYGEN/EXPLOSIVE METERS AND CALIBRATE SAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 January 1992
Resolved 10 January 1992
Construction/Loadline
Issued 3 July 1991 Resolved
SUBMIT FOR APPROVAL, DRAWINGS OF RAW WATER LEG RISERS SYSTEM.
Condition: Unknown
Due 3 July 1991
Resolved 3 July 1991
Construction/Loadline
Issued 3 July 1991 Resolved
AFTER COMPLETION OF NEXT HOLE, MAKE PERMANENT REPAIRS TO CRACKS (7) FOUND IN CAN TO CHORD (5-1 TO 5-11) CONNECTIONS ON ALL LEGS AS INDICATED IN REPORT.
Condition: Unknown
Due 3 July 1991
Resolved 3 July 1991
Construction/Loadline
Issued 11 March 1991 Resolved
REPAIR OR REPLACE CHECK VALVE IN #7 PORT PRELOAD TANK TO PROVIDE COMPLETE CLOSURE AND SEAL OF VALVE.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Construction/Loadline
Issued 11 March 1991 Resolved
REPAIR FROZEN MUD PIT DUMP VALVE.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Construction/Loadline
Issued 11 March 1991 Resolved
REPLACE DUMP STOP VALVE HOUSING AND GATE IN #6 STBD PRELOAD TANK.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Construction/Loadline
Issued 11 March 1991 Resolved
REPLACE THE DUMP STOP VALVE HOUSING, GATE, AND REWORK THE VALVE BONNET TO PROVIDE SMOOTH OPERATION OF STOP VALVE IN #7 PORT PRELOAD TANK.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Construction/Loadline
Issued 11 March 1991 Resolved
CONDUCT THE UNDERWATER PORTION OF THE SEILODD DURING THE NEXT VSL MOVE THE VSL IS PRESENTLY LOCATED AT EI BLOCK 330.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Electrical
Issued 10 December 1990 Resolved
TESTED EMERGENCY BATTERIES IN ACCORDANCE WITH 46 CFR 109.211(B) AND LOG. THIS IS TO BE PERFORMED SEMI - ANNUALLY.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Electrical
Issued 10 December 1990 Resolved
REPLACE OR REPAIR FLAPPER IN MUD PIT ROOM FOR LOSS OF EXHAUST VENTILLATION.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Lifesaving
Issued 10 December 1990 Resolved
PROVIDE 12 HAND - HELD RED PARACHUTE DISTRESS SIGNALS.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Lifesaving
Issued 10 December 1990 Resolved
PROVIDE TWO (2) FLOATING ORANGE SMOKE SIGNALS FOR EACH LIFEBOAT.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Lifesaving
Issued 10 December 1990 Resolved
PROVIDE AN ADDITIONAL RING LIFE BOUY WITH ATTACHED WATER LIGHT AND SMOKE SIGNAL. INSTALL WITH REMOTE RELEASING MECHANISM IAW 46 CFR 108.515 (D).
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Fire Fighting
Issued 10 December 1990 Resolved
REPLACE GENERAL ALARM BELL (MISSING) TO STARBOARD FORWARD EXTERIOR OF ACCOMM. ROOM.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Electrical
Issued 10 December 1990 Resolved
PROVIDE GUARD FOR CENTER FORWARD LIGHT IN WELL BAY AREA.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Electrical
Issued 10 December 1990 Resolved
PROVIDE EXPLOSION PROOF DRIVER FOR P. A. HORN IN WELL BAY AREA.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Lifesaving
Issued 26 October 1990 Resolved
HAVE DAVIT LAUNCHED LIFERAFT #3 SERVICED AT AN APPROVED FACILITY AND WEIGHT TEST CONDUCTED IN PRESENCE OF A CG MARINE INSPECTOR. UNTIL THIS ITEM IS CLEARED, TOTAL POB NOT TO EXCEED 75 PERSONS.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Construction/Loadline
Issued 2 June 1990 Resolved
REPAIR BENT STANCHION ATOP PAINT LOCKER.
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Electrical
Issued 2 June 1990 Resolved
REPAIR BRACKET, DUCTING AND ELECTRICAL WIRING FOR PAINT LOCKER EXHAUST FAN.ABOVE TO BE COMPLETED PRIOR TO OPERATING VESSEL BUT IN NO CASE LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Fire Fighting
Issued 2 June 1990 Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE RAW WATER SUPPLY SYSTEM. DEMONSTRATE PROPER OPERATION OF THE FIRE PUMP PRIOR TO OPERATING VESSEL BUTIN NO CASE LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Unknown
Issued 13 May 1990 Resolved
CONDUCT WEIGHT TEST OF DAVIT LAUNCH LIFE RAFT HOOKS IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR INSURE THAT INSPECTION RECORD PLATE IS PROPERLY STAMPED WHEN COMPLETED.
Condition: Unknown
Due 13 May 1990
Resolved 13 May 1990
Unknown
Issued 13 May 1990 Resolved
MAKE REPAIRS TO THE LEAKING DRAIN LINE #2P PRELOAD TANK.
Condition: Unknown
Due 13 May 1990
Resolved 13 May 1990
Deck/Cargo
Issued 31 October 1989 Resolved
MAKE DRILL FLOOR AIR RECEIVER AN DRELIEF VALVE AVAILABLE FOR INSPECTION BY USCG INSPECTOR.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Lifesaving
Issued 31 October 1989 Resolved
OPERATIONALLY TEST PORT AND STARBOARD LIFEBOATS IN WATER.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Fire Fighting
Issued 31 October 1989 Resolved
RENEW OR REPLACE GALLEY RANGE HOOD FIRE EXTINGUISHER SYSTEM WITH USCG MARINE TYPE SYSTEM.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Accommodation/Occupational Safety
Issued 31 October 1989 Resolved
PROVIDE POTABLE AND SANITARY WATER SURGE TANK AIR SUPPLY LINES WITH CORRECTVALVES (SCHRADER TYPE) NOT CAPABLE OF BEING CONNECTED TOGETHER TO AIR SUPPLY HOSE.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Engineering
Issued 31 October 1989 Resolved
PROVIDE EMERGENCY GENERATOR WITH LOW LUBE OIL PRESSURE SHUT DOWN.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Lifesaving
Issued 31 October 1989 Resolved
PROVIDE (66) BAGS OF WATER FOR PORT LIFEBOAT.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Lifesaving
Issued 31 October 1989 Resolved
PROVIDE 12 ROCKET PROPELLED PARACHUTE FLARES FOR RIG.
Condition: Unknown
Due 31 October 1989
Resolved 31 October 1989
Electrical
Issued 22 November 1988 Resolved
REPAIR PURGE ALARM ON THE BOP CONTROL PANEL LOCATED ON DRILL FLOOR STARBOARD SIDE.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
PROVIDE AUDIBLE OR VISUAL PURGE ALARM FOR THE ADAIR MUD MONITORING SYSTEM LOCATED ADJACENT TO THE DRILLERS CONSOLE. NFPA 496
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
PROVIDE TAGS FOR THE BOP CONTROL PANEL. QUAD OFFSHORE AND DRILLERS CONSOLE IN ACCORDANCE WITH NFPA 496.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
STENCIL ON THE NAME PLATE ALL GENERAL ALARM FEEDER PANELS IAW 46CFR 113.25-20 .
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
ENSURE GENERAL ALARM POWER SUPPLY IS IN COMPLIANCE WITH 46 CFR 113.25-6 113.25-7, 113.25-8, & 113.25-16.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
MAKE OPERABLE THE GENERAL ALARM BELL ON DRILL FLOOR.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Lifesaving
Issued 22 November 1988 Resolved
PROVIDE FOILLE (FIRST AID SPRAY FOR BURNS ECT) FOR THE FIRST AID KIT IN THE HOSPITAL SPACE.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REMOVE SILICON GASKETS ON ALL EXPLOSION PROOF JUNCTION BOXES AND SWITCHES IN THE SHALE SHAKER AREA.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
PROVIDE DIRECTABLE LIGHTS ON EMERGENCY LIGHTING CIRCUIT FOR BOTH LIFERAFT STATIONS
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
RENEW BULB IN EMERGENCY LIGHT FOR NUMBER 1 LIFEBOAT.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REPLACE GENERAL ALARM BATTERYS ( WITH INVERTER SECURED (OFF) THE SYSTEM WILL NOT FUNCTION LONGER THAN ONE MINUTE- (8HRS REQUIRED) GENERAL ALARM SYSTEM MUST BE BATTERY POWERED)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Documentation
Issued 22 November 1988 Resolved
REVISE AND RESUBMIT OPERATIONS MANUAL TO INCLUDE ALL REQUIRED INFORMATION IN 46 CFR 107.121.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Fire Fighting
Issued 22 November 1988 Resolved
PROVIDE TWO STANDARD FIREMAN'S OUTFITS (COATS, BOOTS, & PANTS (IF COAT NOT KNEE LENGTH) AND HELMET)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Accommodation/Occupational Safety
Issued 22 November 1988 Resolved
REPLACE GRILL ON FAN IN TOILET IN RM 3-2.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
MAKE OPERABLE THE GENERAL ALARM BELL ON MAIN DECK STARBOARD JACKHOUSE (EXTERIOR)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Construction/Loadline
Issued 22 November 1988 Resolved
MAKE PERMANENT REPAIRS TO THE SALTWATER PIPING SYSTEM IN THE MACHINERY SPACE ABOVE THE GENERATOR BELLS. ( A TEMPORARY REPAIR IS IN PLACE, REMOVE JOINT TO JOINT & INSERT. ABOVE THAT PIPE A BRANCHLINE IS BEGINNING TO LEAK A WELD.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Engineering
Issued 22 November 1988 Resolved
REPLACE THE RELIEF VALVE ON AIR RECIEVER 82-2694. (AIR RECIEVER MAWP 155 VALVE TAG INDICATES 160 PSI JET)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Fire Fighting
Issued 22 November 1988 Resolved
CLEAN FOG APPLICATORS MALE ENDS SO THEY WILL MATE WITH THE ALL PURPOSE NOZZELS PROPERLY.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Fire Fighting
Issued 22 November 1988 Resolved
HYDRO TEST AIR PACK BOTTLE IN ENGINEERS SPACE BEHIND THE SCR ROOM.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
CORRECT OVERSPEED TRIP ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
MAKE OPERABLE THE GENERAL ALARM IN THE MUD PIT.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
INSTALL PADLOCK ON BATTERY CHARGER CUT-OUT HANDLE (APPROVED DRAWINGS CALL FOR LOCKOUT DEVICE ON BOX. WHEN THIS SWITCH IS OFF THE ENTIRE GENERAL ALARM SYSYTEM IS INOPERATIVE. THE BATTERY CHARGER IS INFACT A INVERTER AC TO DC THAT WILL DRIVE THE ENTIRE SYSTEM.)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
ADD ADDITIONAL EYS FITTINGS ON SHALE SHAKERS TO COMPLY WITH WIRING REQUIRE-MENTS IN A CLASS I DIVISION I ARE.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REPLACE NON EXPLOSION PROOF JUNCTION BOX WITH EXPLOSION PROOF TYPE WITHIN 5 FT RADIUS OF PAINT LOCKER DOOR EXTERIOR ( CLASS I DIVISION I AREA)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Navigation
Issued 22 November 1988 Resolved
CORRECT OBSTRUCTION LIGHTS FLASHING SEQUENCE DISCREPANCY, ALL OBSTRUCTION LIGHTS SHOULD FLASH IN UNISON.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REPLACE WASTED HANGERS ON WIRE UNDERNEATH DRILL FLOOR. WIRE IS CURRENTLY HANGING LOOSE.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REPLACE WIRING FROM GA DETECTION EQUIPMENT (QUAD OFFSHORE) WITH APPROVED TYPE. CURRENT WIRING DOES NOT APPEAR APPROVED FOR MARINE USE.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REPLACE ALL PLASTIC TIE WRAPS SUPPORTING GAS DETECION EQUIPMENT WIRING FROMDRILL FLOOR TO BRANCH AREAS WITH 5/8" WIDTH NON-CORROSIVE WRAPS. (IEEE-45)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REPLACE GROMMET TYPE FITTING WITH EYS FITTING ON EXPLOSION PROOF JUNCTION BOX LOCATED STARBOARD SIDE OF THE SHAKER AREA (CLASS I, DIVISION I)
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
PROVIDE VISUAL OR AUDIBLE ALARM FOR "QUAD OFFSHORE" PURGED JUNCTION BOX FOR GAS DETECTOR. NFPA 496
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Lifesaving
Issued 2 November 1987 Resolved
PROVIDE ON BOARD ONE ADDITIONAL 25 MAN, INFLATABLE, DAVIT LAUNCHED LIFE- RAFT AT RAFT STATION #1 AND CONDUCT WEIGHT TEST OF ASSOCIATED (STBD SIDE) DAVIT.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Electrical
Issued 2 November 1987 Resolved
REPAIR #5 GENERATOR AND CONDUCT TESTS OF ALARMS AND SHUTDOWN IN THE PRESENCE OF A COAST MARINE INSPECTOR.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Lifesaving
Issued 2 November 1987 Resolved
CONDUCT AND LOG, FIRE AND BOAT DRILLS ON LOCATION PRIOR TO COMMENCING NEXT DRILLING OPERATION.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Lifesaving
Issued 12 December 1984 Resolved
CONDUCT WEIGHT TESTS OF BOTH SURVIVAL CAPSULES AND CAVIT LAUNCH LIFERAFT DAVITS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 December 1984
Resolved 12 December 1984
Lifesaving
Issued 11 January 1984 Resolved
PROVIDE THREE (3) HAND-HELO ROCKET PROPELLED FLARES FOR RIG. 46CFR108.521
Condition: Unknown
Due 11 January 1984
Resolved 11 January 1984
Lifesaving
Issued 11 January 1984 Resolved
PROVIDE 1500 FOOT AUXILLARY LINE FOR LINE THROWING GUN. 46CFR108.517
Condition: Unknown
Due 11 January 1984
Resolved 11 January 1984
Construction/Loadline
Issued 11 January 1984 Resolved
REPAIR THE GAS TIGHT DOORS TO THE MUD PIT SO THEY ARE GAS TIGHT. 46CFR11.92
Condition: Unknown
Due 11 January 1984
Resolved 11 January 1984
Unknown
Issued 11 January 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU GLOMAR MAIN PASS IV,DN653307
Condition: Unknown
Due 11 January 1984
Resolved 11 January 1984
Lifesaving
Issued 11 January 1984 Resolved
PROVIDE ANNUAL SERVICING FOR THE TWO AUTOMATIC RELEASING DEVICES FOR THE DAVIT LAUNCHED LIFERAFTS. 46CFR107.239(C)
Condition: Unknown
Due 11 January 1984
Resolved 11 January 1984

Casualty record · 3

22 October 2002Routine · role: Involved in a Marine Casualty · activity 1695629
5 November 2002Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 1705956
18 March 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1767530
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.